• Title/Summary/Keyword: Atlantoaxial arthrodesis

Search Result 5, Processing Time 0.019 seconds

Surgical Treatment of the Atlantoaxial Osteoarthritis

  • Jin, Kwang-Ouk;Kim, Young-Woo;Rim, Dae-Cheol;Ahn, Sung-Ki
    • Journal of Korean Neurosurgical Society
    • /
    • v.41 no.4
    • /
    • pp.264-266
    • /
    • 2007
  • Atlantoaxial facet joint osteoarthritis is rare, often undiagnosed because it may be misdiagnosed as occipital neuralgia, or degenerative cervical spondylosis. Unilateral occipitocervical pain aggravated by head rotation is a specific symptom. Conservative treatment is usually effective. But when the patient complains of intractable neck pain localized to occipitocervical junction and unresponsive to medical therapy, surgical treatment should be considered. Though a few reports of surgically treated atlantoaxial osteoarthritis has been published, surgical outcome is favorable. A case of a surgically treated atlantoaxial osteoarthritis is presented with a review of the literatures.

Radiological Diagnosis and Surgical Stabilization of the Atlantoaxial Subluxation in a dog (개의 환축추 아탁구의 방사선진단 및 외과적 고정)

  • 김남수
    • Journal of Veterinary Clinics
    • /
    • v.14 no.1
    • /
    • pp.126-130
    • /
    • 1997
  • 10개월경의 그리폰 벤딘 수컷 강아지가 8개월경부터 점점 운동 실조 및 마비증상을 나타내어 머독대학 동물병원에 내원 하였다. 내원 했을 때 주변에 매우 민감한 반응과 경계를 늦추지 않았지만 호흡과 심박수 및 체온은 정상이었다. 일반 방사선 사진 및 척수조영사진(myelography)을 촬영하여 확인한 결과 환축추의 불안정에 따른 척수의 복측 압박을 확인할 수 있었다. 외과적 고정은 복측 접근을 통하여 2개의 키르크너 강선(Kirschner wire)과 자가골이식을 실시하였으며 8주동안 외부 고정을 하였다. 수술 후 5개월 동안 지켜본 결과 증상은 꾸준히 좋아졌으며 환축추 관절으 관절고정술(arthrodesis)은 완벽한 고정을 유지하고 있었다.

  • PDF

Posterior Atlantoaxial Transarticular Screw Fixation

  • Ko, Byung-Su;Lee, Jung-Kil;Kim, Yeon-Seong;Moon, Sung-Jun;Kim, Jae-Hyoo;Kim, Soo-Han
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.3
    • /
    • pp.179-183
    • /
    • 2007
  • Objective : Posterior arthrodesis in atlantoaxial instability has been performed using various posterior C1-2 wiring techniques. Recently, transarticular screw fixation (TASF) technique was introduced to achieve significant immediate stability of the C1-2 joint complex. The purpose of this study is to assess the clinical outcomes associated with posterior C1-2 TASF for the patient of atlantoaxial instability. Methods : We retrospectively reviewed data obtained from 17 patients who underwent C1-2 TASF and supplemented Posterior wiring technique (PWT) with graft between 1994 and 2005. There were 8 men and 9 women with a mean age of 43.5 years (range, 12-65 years). An average follow-up was 26 months (range, 15-108 months). Results : Successful fusions were achieved in 16 of 17 (94%). The pain was improved markedly (3 patients) or resolved completely (14 patients). There was no case of neurological deterioration, hypoglossal nerve injury, or vertebral artery injury. Progression of spinal deformity, screw pullout or breakage, and neurological or vascular complications did not occur. Conclusion : The C1-2 TASF with supplemental wiring provided a high fusion rate. Our result demonstrates that C1-2 TASF supplemented by PWT is a safe and effective procedure for atlantoaxial instability. Preoperative evaluation and planning is mandatory for optimal safety.

Clinical Experiences and Usefulness of Cervical Posterior Stabilization with Polyaxial Screw-Rod System

  • Hwang, In-Chang;Kang, Dong-Ho;Han, Jong-Woo;Park, In-Sung;Lee, Chul-Hee;Park, Sun-Young
    • Journal of Korean Neurosurgical Society
    • /
    • v.42 no.4
    • /
    • pp.311-316
    • /
    • 2007
  • Objective : The objective of this study is to investigate the safety, surgical efficacy, and advantages of a polyaxial screw-rod system for posterior occipitocervicothoracic arthrodesis. Methods : Charts and radiographs of 32 patients who underwent posterior cervical fixation between October 2004 and February 2006 were retrospectively reviewed. Posterior cervical polyaxial screw-rod fixation was applied on the cervical spine and/or upper thoracic spine. The surgical indication was fracture or dislocation in 18, C1-2 ligamentous injury with trauma in 5, atlantoaxial instability by rheumatoid arthritis (RA) or diffuse idiopathic skeletal hyperostosis (DISH) in 4, cervical spondylosis with myelopathy in 4, and spinal metastatic tumor in 1. The patients were followed up and evaluated based on their clinical status and radiographs at 1, 3, 6 months and 1 year after surgery. Results : A total of 189 screws were implanted in 32 patients. Fixation was carried out over an average of 3.3 spinal segment (range, 2 to 7). The mean follow-up interval was 20.2 months. This system allowed for screw placement in the occiput, C1 lateral mass, C2 pars, C3-7 lateral masses, as well as the lower cervical and upper thoracic pedicles. Satisfactory bony fusion and reduction were achieved and confirmed in postoperative flexion-extension lateral radiographs and computed tomography (CT) scans in all cases. Revision surgery was required in two cases due to deep wound infection. One case needed a skin graft due to necrotic change. There was one case of kyphotic change due to adjacent segmental degeneration. There were no other complications, such as cord or vertebral artery injury, cerebrospinal fluid leak, screw malposition or back-out, or implant failure, and there were no cases of postoperative radiculopathy due to foraminal stenosis. Conclusion : Posterior cervical stabilization with a polyaxial screw-rod system is a safe and reliable technique that appears to offer several advantages over existing methods. Further biomechanical testings and clinical experiences are needed in order to determine the true benefits of this procedure.

Comparative Analysis of Surgical Outcomes of C1-2 Fusion Spine Surgery between Intraoperative Computed Tomography Image Based Navigation-Guided Operation and Fluoroscopy-Guided Operation

  • Lee, Jun Seok;Son, Dong Wuk;Lee, Su Hun;Ki, Sung Soon;Lee, Sang Weon;Song, Geun Sung
    • Journal of Korean Neurosurgical Society
    • /
    • v.63 no.2
    • /
    • pp.237-247
    • /
    • 2020
  • Objective : Fixation of the C1-2 segment is challenging because of the complex anatomy in the region and the need for a high degree of accuracy to avoid complications. Preoperative 3D-computed tomography (CT) scans can help reduce the risk of complications in the vertebral artery, spinal cord, and nerve roots. However, the patient may be susceptible to injury if the patient's anatomy does not match the preoperative CT scans. The intraoperative 3D image-based navigation systems have reduced complications in instrument-assisted techniques due to greater accuracy. This study aimed to compare the radiologic outcomes of C1-2 fusion surgery between intraoperative CT image-guided operation and fluoroscopy-guided operation. Methods : We retrospectively reviewed the radiologic images of 34 patients who underwent C1-2 fusion spine surgery from January 2009 to November 2018 at our hospital. We assessed 17 cases each of degenerative cervical disease and trauma in a study population of 18 males and 16 females. The mean age was 54.8 years. A total of 139 screws were used and the surgical procedures included 68 screws in the C1 lateral mass, 58 screws in C2 pedicle, nine screws in C2 lamina and C2 pars screws, four lateral mass screws in sub-axial level. Of the 34 patients, 19 patients underwent screw insertion using intraoperative mobile CT. Other patients underwent atlantoaxial fusion with a standard fluoroscopy-guided device. Results : A total of 139 screws were correctly positioned. We analyzed the positions of 135 screws except for the four screws that performed the lateral mass screws in C3 vertebra. Minor screw penetration was observed in seven cases (5.2%), and major pedicle screw penetration was observed in three cases (2.2%). In one case, the malposition of a C2 pedicle screw was confirmed, which was subsequently corrected. There were no complications regarding vertebral artery injury or onset of new neurologic deficits. The screw malposition rate was lower (5.3%) in patients who underwent intraoperative CT-based navigation than that for fluoroscopy-guided cases (10.2%). And we confirmed that the operation time can be significantly reduced by surgery using intraoperative O-arm device. Conclusion : Spinal navigation using intraoperative cone-beam CT scans is reliable for posterior fixation in unstable C1-2 pathologies and can be reduced the operative time.