• Title/Summary/Keyword: At-the-Valve Test

Search Result 262, Processing Time 0.023 seconds

Maximal Oxygen Uptake in the Secondary School Girls (여자 중 . 고등 학생의 최대 산소 섭취량)

  • Chung, Il-Dong;Nam, Kee-Yong
    • The Korean Journal of Physiology
    • /
    • v.2 no.2
    • /
    • pp.11-20
    • /
    • 1968
  • Maximal oxygen uptake was measured in thirty-three secondary school girls by means of the treadmill test. Eighteen middle school girls aged 14.0 (range: $13.0{\sim}15.9$) years and fifteen high school girls aged 16.9 (range: $16.0{\sim}18.0$) years served as subjects. Maximal treadmill run lasted for 2 minutes and 20 seconds and the expired air was collected in a Douglas bag through a J-valve during the last one minute period. In general, absolute values of various measurements in the high school girls were greater than those of the middle school girls. When values were expressed on the body weight or lean body weight basis, however, work capacity of middle school girls was superior to that of the high school girls. The detailed results are as follows: 1. In middle school girls maximal oxygen uptake was 1.78 l/min., 47.4 ml/kg body weight, 12.3 ml/cm body height, and 61.7ml/kg lean body mass. In high school girls maximal oxygen uptake was 1.93 l/min., 39.7ml/kg body weight, 12.3 ml/cm body height, and 51.2 ml/kg LBM. Although the absolute value of maximal oxygen uptake was greater in high school girls than in middle school girls, values expressed on the body weight basis showed the reverse trend, namely, values of the middle school girls was greater than those of the high school girls. 2. The ratio of maximal to resting oxygen uptake was 8.8 in the middle school girls and was 10.2 in the high school girls. 3. Maximal pulmonary ventilation in the middle school girls was 55.3 l/min. and 66.1 l/min. in the high school girls. The ratio of maximal to resting pulmonary ventilation was 10.2 in the middle school girls and 10.1 in the high school girls. 4. The correlation between body weight and maximal oxygen uptake was relatively high, namely, r=0.79 both in middle and high school girls. The correlation coefficient between body weight and maximal pulmonary ventilation was a little less that of between maximal oxygen uptake and showed a value of r=0.60 both in middle and high school girls. The lean body mass was a poor reference of maximal oxygen uptake or maximal pulmonary ventilation as compared to body weight. The correlation between maximal oxygen uptake and maximal pulmonary ventilation was high and the coefficient of correlation in middle school girls was 0.927 and in high school girls it was 0.856. 5. Maximal ventilation equivalent was 30.9 liters in middle school girls and 33.9 liters in high school girls. This indicated that no hyperventilation was induced during the maximal of oxygen uptake exercise period as related to the maximal oxygen uptake. 6. Heart rate reached to the peak value within 1.5 minutes after beginning of maximal oxygen uptake run and remained at the same peak plateau level throughout the entire running period. Heart rate decreased steeply on cessation of running and subsided slowly thereafter. The maximal heart rate was 184 beat/min. in middle school girls and 189 beat/min. in high school girls. 7. Maximal oxygen pulse was 9.4 in middle school girls and 9.9 ml/beat in high school girls.

  • PDF

The Physical Properties of Port Type Crack Injection Method Using Latex Elastic Storage Tube (라텍스 탄성 저장관을 활용한 포트식 균열주입 공법의 물리적 특성에 관한 연구)

  • Kim, Eun-Young;Sho, Kwang-Ho
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.22 no.2
    • /
    • pp.68-75
    • /
    • 2018
  • In this study, to solve the problems of the conventional crack repair and injection method, high elasticity latex was used as the material of the storage tube to withstand the high pressure in the center part differently from the general port. When the repair solution was injected into the crack part, The TPS method was developed so that the air existing in the TPS can be discharged. In addition, a new infusion port in which a valve blocking the backflow of the remediation solution was installed at the injection port was developed and the physical characteristics of the port were analyzed. As a result of the evaluation, it was found that the filling rate of the remedial solution was improved compared to the existing ordinary injector method, and the cracks were completely filled in the test conditions. Compressive strength and tensile strength after repair showed about 20% decrease after repair in case of using ordinary injector method, while TPS method showed about 2~7% increase after repair. The results of this study showed that the injection port method using the elastic storage tube increased the injection performance and the quality after repair compared to the conventional injector method. The result of this study is expected to be utilized as the basic data for application and commercialization of the result to the practical structure.

A Study on the Wear Characteristics of Aluminizing Steel ( 1 ) - Wear in Run-in Period on Rolling-Sliding Contact - (알루미나이징 강의 마모특성에 관한 연구 ( 1 ) - Rolling-Sliding 마찰의 초기마모영역을 중심으로 -)

  • 이규용
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.14 no.2
    • /
    • pp.69-78
    • /
    • 1978
  • It is well known that the aluminizing steel is excellent in corrosion resistance and heat resistance. Therefore it has been used as boiler parts, heat exchanger parts and guide rails which are used under comparatively simple conditions. Recently, it has been noticed that aluminizing steel has high resistance to various atmosphere, high temperature oxidation and seawater resistance. So its usage has been extended widely to the production of parts such as intake and exhaust valve of internal combustion engine, turbine blade and pipelines On ships which required such properties. It is considered that aluminium coated steel is excellent in wear resistance because of high hardness on main ingredient FezAIs of Fe-AI alloy layer existed in diffusion coating layer. And it will beused as a new material taking wear resitance with seawater resistance in marine field. However it is difficult to findout any report concering the wear behaviors or properties of alum in izing steel. In this study the experiment was carried out under the condition of rolling-sliding contact using an Amsler-type wear testing machine at 0.80, 0.91, 1. 10, 1. 25% of slip ratio and 55.43, 78.38, 110.85 kg/mm^2 of Hertz's contact stress in run-in period for the purpose of service-ability test of aluminizing steel as a wear resisting material and obtaining the available design data. The followings are the obtained results from the experimen tal study; 1) The 2nd diffusion material has most excellent wear resistance. This material has brought out about 18% decrease of wear weight in a lower friction load level and 40~G decrease in a higher level comparing to the raw material. 2) Satisfactory effect of wear resistivity cannot be much expected in 2nd diffusion specimens. This is considered due to the formation of fine void in the alloy layer near the boundary to the aluminium layer. 3) Fracture on friction surface of aluminizing steel by the rolling-sliding contact is spalling, and spalling crack occurres initially beneath the specimen surface near the boundary in diffusion coating layer.

  • PDF

An Experimental Study on Flow Distributor Performance with Single-Train Passive Safety System of SMART-ITL (SMART-ITL 1 계열 피동안전계통을 이용한 유동분사기 성능에 대한 실험연구)

  • Ryu, Sung Uk;Bae, Hwang;Yang, Jin Hwa;Jeon, Byong Guk;Yun, Eun Koo;Kim, Jaemin;Bang, Yoon Gon;Kim, Myung Joon;Yi, Sung-Jae;Park, Hyun-Sik
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.124-132
    • /
    • 2016
  • In order to estimate the effect of flow distributors connected to an upper nozzle of CMT(Core Makeup Tank) on the thermal-hydraulic characteristics in the tank, a simplified 2 inch Small Break Loss of Coolant Accident(SBLOCA) was simulated by skipping the decay power and Passive Residual Heat Removal System(PRHRS) actuation. The CMT is a part of safety injection systems in the SMART (System Integrated Modular Advanced Reactor). Each test was performed with reliable boundary conditions. It means that the pressure distribution is provided with repeatable and reproducible behavior during SBLOCA simulations. The maximum flow rates were achieved at around 350 seconds after the initial opening of the isolation valve installed in CMT. After a short period of decreased flow rate, it attained a steady injection flow rate after about 1,250 seconds. This unstable injection period of the CMT coolant is due to the condensation of steam injected into the upper part of CMT. The steady injection flow rate was about 8.4% higher with B-type distributor than that with A-type distributor. The gravity injection during hot condition tests were in good agreement with that during cold condition tests except for the early stages.

Improved Radiochemical Yields, Reliability and Improvement of Domestic $^{18}F$-FDG Auto Synthesizer (국산 $^{18}F$-FDG Auto Sysnthesizer의 수율 향상과 성능 개선)

  • Park, Jun-Hyung;Im, Ki-Seop;Lee, Hong-Jin;Jeong, Kyung-Il;Lee, Byung-Chul;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.147-151
    • /
    • 2009
  • Purpose: 2-[$^{18}F$]Fluoro-2-deoxy-D-glucose ([$^{18}F$]FDG) particularly plays as a important role in Positron Emission Tomography (PET) imaging in nuclear medicine. Domestic [$^{18}F$]FDG auto synthesizers are installed in Seoul National University Bundang Hospital (SNUBH) at June 2008, these modules were known that it's synthetic yields were guaranteed in average $45{\pm}5%$ so far. To improve yields and convenience of domestic [$^{18}F$]FDG auto synthesizer, numerous trials in reaction time, base concentration, pressure and temperature were performed to increase [$^{18}F$]FDG yields. Materials and Methods: Several synthetic factors (temperature, time and pressure) and shortcoming were corrected based on many evaporation test. Syringe dispensing of tetra-butylammonium bicarbonate (TBAB) was replaced with micro pipette to prepare tetrabutyl ammonium fluoride salt ([$^{18}F$]TBAF). Troublesome refill of liquid nitrogen every 2 hours which was used to protect vacuum system was changed to charcoal cartridge, base guard filter. To monitor the volume of delivered $[^{18}O]OH_2$ from cyclotron by surveillance camera, we set up the volumetric vial on the cover of the module. In addition to, the recovery vial was added in [$^{18}F$]FDG production system to recover [$^{18}F$]FDG loss due to the leak of valve ($V_{13,14}$) in [$^{18}F$]FDG purification process. Results: When we used micro pipette for adding TBAB ($30\;{\mu}L$ in 12% $H_2O$ in acetonitrile), this quantitative dispensation has enabled to improve $5.5{\pm}1.7%$ residual fluorine-18 activity in fluorine separation cartridge compared to syringe adding. Besides, the synthetic yields of [$^{18}F$]FDG has increased $58{\pm}2.6%$ (n=19), $58{\pm}2.9%$ (n=14), $60%{\pm}2.5%$ (n=17) for 3 months. The life cycle of charcoal cartridge and base vacuum was 3 months prior to filling liquid nitrogen every 2 hours and additional side separator can prevent pump corrosion by organic solvent. After setting of volumetric indicator vial, the operator can easily monitor the total volume of irradiated $[^{18}O]OH_2$ from cyclotron. The recovery vial can be used for the stabilizer when an irregular [$^{18}F$]FDG loss was generated by the leak of valves ($V_{13,14}$). Conclusions: We has optimized appropriate synthetic conditions (temperature, time, pressure) in domestic [$^{18}F$]FDG auto synthesizer. In addition to, the remodeling with several accessories improve yields of domestic [$^{18}F$]FDG auto synthesizer with reliable reproducibility.

  • PDF

Sliding Wear Properties of Graphite as Sealing Materials for Cut off Hot Gas (고온차단 기밀용 그라파이트의 고온 미끄럼마모 특성 평가)

  • Kim, YeonWook;Kim, JaeHoon;Yang, HoYeong;Park, SungHan;Lee, HwanKyu;Kim, BumKeun;Lee, SeungBum;Kwak, JaeSu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.11
    • /
    • pp.1349-1354
    • /
    • 2013
  • Sealing structure to prevent flowing hot gas into the driving device, located between the driving shaft and the liner of On-Off valve for controlling the hot gas flow path was studied. Wear occurs due to the constant movement of the driving shaft controlled by actuator on graphite as the sealing material. In this paper, the dynamic wear behavior in high temperature of graphite(HK-6) to be used as sealing material was evaluated. Reciprocating wear test was carried out for the graphite(HK-6) to the relative motion between shaft materials(W-25Re). The results of friction coefficient and specific wear rate according to contact load, sliding speed at room temperature and $485^{\circ}C$ considering the actual operating environment were evaluated. Through the SEM analysis of the worn surface, third body as lubricant films were observed and lubricant effect of third body was considered.

Effects of changing position on cardiac output & on patient's discomforts after cardiac surgery (개심술을 받은 환자의 체위에 따른 심박출량 및 불편감에 관한 연구)

  • Yu Mi;Kwon Eun-Ok;Choi Yun-Kyoung;Kang Hyun-Ju;Oh Se-Eun
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.7 no.2
    • /
    • pp.256-270
    • /
    • 2000
  • Invasive hemodynamic monitoring has become a valuable assessment parameters in critical care nursing in patients undergoing open heart surgery patients. During cardiac surgery, the Swan Ganz catheter is placed in the pulmonary artery. Critical care nurses routinely obtain cardiac output, cardiac index, and pulmonary arterial pressure in these patients. Traditionally, patients are positioned flat and supine for cardiac output measurement. Numerous studies have dealt with the effects of changing position on the hemodynamic variables. However, there are a few studies dealing with patients who undergo cardiac surgery in Korea. Thus, the purpose of this study was to determine the effects of changing position on cardiac output, PAP, CVP, BP, HR and discomfort in patients after cardiac surgery. A sample of 21 adults who had CABG and/or valve replacement with Swan Ganz catheters in place was studied. The data were collected in the cardiac ICU of a university hospital in Seoul during the period from July 28, 1999 to August 30. 1999. In this study, the independent variable is patient position in the supine, 30 degree, and 45 degree angles. Dependent variables are C.O., C.I., CVP, PAP, MAP, HR and patients' perceived discomforts. Subject discomfort was measured subjectively by visual analogue scale. Other hemodynamic data where collected by the thermodilution method and by direct measurement. The data were analyzed by percentile, t-test, ANOVA, Linear regression analysis using SPSS-/WIN program. The results are as follows : 1) Changes in cardiac output were absent in different angle positions, 0, 30. 45 degrees(F=.070, P=.932). Changes in cardiac index were absent in different angle positions, 0. 30, 45 degrees(P>.05). 2) Changes in central venous pressure were absent in different angle positions, 0, 30, 45 degree(P>.05). 3) PAP had no change in different angle 0, 30, 45 degree positions; systolic PAP(P>.05), diastolic PAP(P>.05). 4) Changes in systolic blood pressure were absent in different angle positions, 0, 30, 45 degree(P>.05). 5) Changes in heart rates were absent in different angle positions, 0, 30, 45 degree(P>.05). 6) Patients' perceived discomfort was absent in different angle positions, 0, 30, 45 degree(p<.05). In conclusion, critical care nurses can measure C.O., C.I., PAP, BP, & CVP in cardiac surgery patients at 30 degree or 45 degree positions. This can improve the patients' comfort.

  • PDF

Evaluation of Plasma D-Dimer Concentration in Dogs with Chronic Mitral Valve Insufficiency (만성 이첨판 폐쇄부전증에 걸린 개에서 혈장 D-dimer 농도 측정 연구)

  • Park, Joungsoon;Suh, Sang-Il;Oh, Yeonsu;Hyun, Changbaig
    • Journal of Veterinary Clinics
    • /
    • v.32 no.1
    • /
    • pp.5-8
    • /
    • 2015
  • D-dimer is a fibrin degradation product (FDP), a small protein fragment present in the blood after a blood clot is degraded by fibrinolysis. D-dimer concentration is widely used for determining thrombosis and thromboembolism. Because one major cause of thromboembolism is congestive heart failure in human, we investigated the degree and risk of thromboembolism in dogs with different stage of congestive heart failure caused by chronic mitral valvular insufficiency (CMVI). The plasma level of d-dimer was evaluated in 20 healthy dogs and 30 dogs with different stage of congestive heart failure caused by CMVI. The d-dimer concentrations were measured by a commercialized assay kit. The plasma levels of d-dimer were not significantly different between healthy and CMVI dogs. Furthermore, there was no association of d-dimer concentrations to left atrium to aorta (LA/Ao) ratio, left ventricular dimension at diastole to aorta (LVIDd/Ao) ratio and severity of heart failure in our study population. Our study results implied that the degree of thromboembolism in canine heart failure might be minimal or the plasma d-dimer test might not be reliable for detecting thromboembolism in dogs.

Giant Magnetoresistance of Antiferromagnetic Cr-Al based Multilayer Spin-Valve with Anti-Corrosion and Thermal Stability (내열 내식용 Cr-Al반강자성계 스핀밸브막의 거대자기저항 효과)

  • 김병수;이성훈;이찬규
    • Journal of the Korean Magnetics Society
    • /
    • v.8 no.6
    • /
    • pp.362-368
    • /
    • 1998
  • The magnetic properties, thermal stability and anti-corrosion properties of $Cr_86Al_14$ spin valves multilayers were studied. It was found that the magnetic properties of $Cr_86Al_14$ spin valves depend on the thickness of antiferromagnetic, ferromagnetic and non-ferromagnetic layers. Exchange coupled field ($H_{ex}$) and magnetoresistance ratio (%) showed the largest value of 20 Oe, 2 % in $glass/Cr_{86}Al_{14}(600 $\AA$)/Ni_{81}Fe_{19}(50$\AA$)/Cu(40 $\AA$)/Ni_{81}Fe_{19}(40 $\AA$)$ spin valves. The $H_{ex}$ MR ratios (%) of CrAl and FeMn spin valves were decreased with increasing annealing temperatures and were lost at 150 $^{\circ}C$, 250 $^{\circ}C$ respectively. Based on these result, it was elucidated that CrAl is more thermally stable than FeMn. It was also shown that there was no change of $H_{ex}$ MR ratios in CrAl, while FeMn was changed and lost 15 days later in corrosion resistance test under 35 $^{\circ}C$, 90 % humidity condition. FeMn was found to be pitted and peeled off 15 days later by SEM micrographic analysis.

  • PDF

Quality Changes of Commercial Kimchi Products by Different Packaging Methods (소포장 김치의 포장방법별 품질특성 변화)

  • Hong, Seok-In;Park, Jin-Sook;Park, Noh-Hyun
    • Korean Journal of Food Science and Technology
    • /
    • v.27 no.1
    • /
    • pp.112-118
    • /
    • 1995
  • The effect of various packaging methods on kimchi quality was investigated in order to develop the packaging techniques for preventing commercial kimchi products from inflation and explosion, due to fermentative gas evolved during storage and distribution. Kimchi was packaged in different methods; 1) atmospheric packaging(AP), 2) check valve packaging(CV), 3) double packaging(DP), and 4) vacuum packaging(VP). The quality of kimchi during storage at $10^{\circ}C$ was evaluated in terms of gas composition, free volume, pH, titratable acidity color index and sensory properties. The gas composition inside packages showed different curves according to the packaging methods. Due to fermentative gas accumulation in both AP and CV, $CO_2$ concentration increased by 2 stepwise pattern, while $O_2$, concentration decreased exponentially. In DP, $O_2$ concentration remained constant, but $CO_2$ concentration increased by 2 stepwise pattern and then decreased. In contrast, VP produced low $O_2$ and high $CO_2$ concentrations only at the end of storage. The free volume in both AP and CV showed typical sigmoidal curves similar to $CO_2$ concentration changes. It remained constant in DP, but started to increase at the late stage of storage in VP. There was no significant effect of packaging methods on pH changes of kimchi. In titratable acidity, DP maintained relatively higher than others. Regarding to the color change of crushed kimchi juice in all packages, L and b values decreased exponentially but a value remained constant during storage. Color index(L b/a) of crushed kimchi juice decreased exponentially and remained constant at the end of storage. The growth of lactic acid bacteria was VP, CV, AP, DP in increasing order. In sensory test, the sourness scores of DP were fairly higher than those of others, but the texture was not significantly affected by the packaging methods. The preference for kimchi showed VP>AP, CV>DP in order of score. In this study, it could be proposed to employ DP and VP method as the effective packaging techniques for preventing commercial kimchi products from inflation.

  • PDF