• Title/Summary/Keyword: Asymmetrical hearing loss

Search Result 4, Processing Time 0.02 seconds

A Study on Development of a Hearing Impairment Simulator considering Frequency Selectivity and Asymmetrical Auditory Filter of the Hearing Impaired (난청인의 주파수 선택도와 비대칭적 청각 필터를 고려한 난청 시뮬레이터 개발에 관한 연구)

  • Joo, Sang-Ick;Kang, Hyun-Deok;Song, Young-Rok;Lee, Sang-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.4
    • /
    • pp.831-840
    • /
    • 2010
  • In this paper, we propose a hearing impairment simulator considering reduced frequency selectivity and asymmetrical auditory filter of the hearing impaired, and we verified the reduced frequency selectivity and asymmetrical auditory filter affected in speech perception through experiments. The reduced frequency selectivity has made embodied by spectral smearing using LPC(linear prediction coding). The shapes of auditory filter are asymmetrical different with each center frequency. Hearing impaired person which has hearing loss was differently changed with that of normal hearing people and it has different value for speech of quality through auditory filter. The experiments confirmed subjective test and objective test. The subjective experiments are composed of 4 kinds of tests: pure tone test, SRT(speech reception threshold) test, and WRS(word recognition score) test without spectral smearing, and WRS test with spectral smearing. The experiment of the hearing impairment simulator was performed from 9 subjects who have normal ears. The amount of spectral smearing was controlled by LPC order. The asymmetrical auditory filter of proposed hearing impairment simulator was simulated and then some tests to estimate the filter's performance objectively were performed. The objective experiment as simulated auditory filter's performance evaluation method used PESQ(perceptual evaluation of speech quality) and LLR(log likelihood ratio) for speech through auditory filter. The processed speech was evaluated objective speech quality and distortion using PESQ and LLR value. When hearing loss processed, PESQ and LLR value have big difference according to asymmetrical auditory filter in hearing impairment simulator.

An Objective Estimation for Simulating of Asymmetrical Auditory Filter of the Hearing Impaired According to Hearing Loss Degree (난청인의 난청 정도에 따른 비대칭 청각 필터 구현의 객관적 평가)

  • Joo, S.I.;Jeon, Y.Y.;Song, Y.R.;Lee, S.M.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.3 no.1
    • /
    • pp.27-34
    • /
    • 2009
  • Hearing impaired person's hearing loss has personally various shape, so existing symmetrical auditory filter of frequency band method wasn't properly simulated the hearing impaired person's various hearing loss shape. The shapes of auditory filter are asymmetrical different with each center frequency and each input level. Hearing impaired person which has hearing loss was differently changed with that of normal hearing people and it has different value for speech of quality through auditory filter. In this study, the asymmetrical auditory filter was simulated and then some tests to estimate the filter's performance objectively were performed. The experiment as simulated auditory filter's performance evaluation method used perceptual evaluation of speech quality (PESQ) and log likelihood ratio (LLR) for speech through auditory filter. In the test, processed speech was evaluated objective speech quality and distortion using PESQ and LLR value. When hearing loss processed, PESQ and LLR value have big difference between symmetrical and asymmetrical auditory filter. It means that the difference of the shape auditory filter may affect to speech quality. Especially, when hearing loss existed, auditory filter changing according to asymmetrical shape for each center frequency affected to perceive speech quality of the hearing impaired.

  • PDF

Asymmetrical Hearing Loss and Related Factors Among the Noise Exposed Male Workers (소음 노출 남성근로자에서 청력 역치의 비대칭성과 관련요인)

  • Lee, Nam-Soo;Lee, Kyung-Jae;Kim, Joo-Ja
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.2
    • /
    • pp.94-101
    • /
    • 2010
  • This study was performed to examine the asymmetry of hearing loss among the noise exposed male workers. Findings of otoscopic examination, pure tone audiometry and tympanometry were evaluated for 179 male workers working in the noise exposed workplace. And also selfadministered structured questionnaires were used for each worker's work-related and general characteristics including personal health behaviors. There were significant differences of hearing threshold between right and left ears at 1,000 Hz and 3,000 Hz(p<0.05). And also significant differences of hearing threshold were noted in the age group over 50 at 3,000 Hz, the high risk drinking group either at 3,000 Hz and 4,000 Hz, the work duration group 10-19 years at 3,000 Hz, the noise exposure group under 90 dB(A) at 3,000 Hz, the noise exposure group over 90 dB(A) at 1,000 Hz, the non-wearing protective device group at 4,000 Hz, and the wearing protective device group at 3,000 Hz(p<0.05). Further study is needed to explore the extent and the related factors of the asymmetry of hearing loss in the general population and occupationally noise exposed group.

Hearing Asymmetry among Occupationally Noise-exposed Workers (직업적으로 소음에 노출되는 근로자들에서 청력의 비대칭성)

  • Kim, Wook-Tae;Kim, Dae-Hwan;Lee, Chae-Kwan;Ahn, Jin-Hong;Lee, Chang-Hee;Kim, Hwi-Dong;Kim, Jeong-Ho;Son, Byung-Chul;Lee, Jong-Tae
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.2
    • /
    • pp.153-159
    • /
    • 2007
  • Usually equal noise exposure is considered to cause symmetrical hearing loss, but some screening audiometries of employees who were exposed to noise showed asymmetry. Therefore, this study was carried out to evaluate the distribution of asymmetrical hearing loss and the difference of air conduction level between left and right ear at the different frequencies (500, 1,000, 2,000, 3,000, 4,000, 6,000 Hz). Study subjects were 326 male employees who had participated in the noise-specific health examination from May to October, 2002. They were evaluated by otoscopic examination, pure tone audiometry and tympanometry. In all frequencies, hearing threshold level of left ear was worse than right ear. The mean interaural threshold differences between two ears were 0.83 dB at 500 Hz, 1.18 dB at 2,000 Hz, 2.29 dB at 3,000 Hz, 2.18 dB at 4,000 Hz, and statistically significant (p<0.05). The hearing loss of left ear was greater than right ear in occupationally noise-exposed workers. It is believed that left ear was more susceptible to noise damage than right ear