• 제목/요약/키워드: Asymmetric ventilation

검색결과 13건 처리시간 0.023초

환풍기용 외전형 단상 브러시리스 직류전동기 개발 (Development of Single-phase Brushless DC Motor with Outer Rotor for Ventilation Fan)

  • 박용운;정학균;조주희;소지영;정동화;김대경
    • 조명전기설비학회논문지
    • /
    • 제27권8호
    • /
    • pp.36-41
    • /
    • 2013
  • This paper is development of single-phase brushless DC motor with outer rotor for ventilation fan. Cogging torque causes the noise vibration to greatest impact on ventilation fan. Asymmetric notches are applied to tapered-teeth for cogging torque reduction of single-phase brushless DC motor. Initial model is notchless and proposed model is applied 2 asymmetric notches. The proposed method is proved motor characteristic through finite element analysis(FEA). Also, experimental results verify that the proposed model considerably reduces cogging torque and have the good sound quality in ventilation system.

Theoretical Prediction of Lung Hyperinflation(LHI) Due to Asymmetric Pressure-Flow Characteristics of Human Airways During High Frequency Ventilation (HFV)

  • Cha, Eun-Jong
    • 대한의용생체공학회:의공학회지
    • /
    • 제11권2호
    • /
    • pp.195-202
    • /
    • 1990
  • The hypothesis of asymmetric resistance to explain the phenomenon of lung hyperinflation (LHI) during hlgh frequency ventilation (HFV) was quantitatively studied. LHI was predicted by modeling the ism-volume pressure-flow (IVPF) data from 5 human subjects using the empirical Rohrer's equation. Non-steadiness during HFV was compensated by em- ploying recently proposed volume-frequency diagram. Tidal volume and ventilation frequency were 100 ml and 20 Hz, respectively. Airflow pattern was a symmetric sinusoid. The predic- tion results of mean pressure drop across the airways were averaged for those 5 subjects, and compared with zero by one-sided student's t-test. A marginally significant (P<0.1) increase in mean pressure drop was observed during HFV at low lung volumes (below FRC) , which could increase mean lung volume up to one liter When the lung volume was above FRC, no significant LHI (P >0.25) was resulted. LHI seemed to be inversely related to the lung volume. These results recommend to clinically apply HFV only at lung volumes above FRC.

  • PDF

Effects of Asymmetric Airway Inertance on Mean Lung Volume During High Frequency Ventilation(HFV)

  • Cha, Eun-Jong
    • 대한의용생체공학회:의공학회지
    • /
    • 제11권2호
    • /
    • pp.203-208
    • /
    • 1990
  • A possible asymmetry in airway inertance was modeled based on previously reported radiographic visualization data of the airway wall fluctuation in intact dogs. Effects of asymmetric Inertance on mean lung volume during high frequency ventilation (HFV) were evaluated in terms of mean inertive pressure drop across the airways. It was found that a negligible inertlve pressure drop was expected ($<1{\;}cmH_20$) in normal subjects, while a sig- nificant rise in mean alveolar pressure compared to mean mouth pressure by approximately $3{\;}cmH_20$ was resulted for about 40% airway fluctuation representing bronchoconstriction state by Histamine induction. These results demonstrate that asymmetric Inertance could lead patients with airway diseases to a significant lung hyperinflation (LHI), and bronchodilation treatment is recommended prior to applying HFV to prevent those patients from a possible barotrauma.

  • PDF

대기오염 입자의 인체 호흡기내 비대칭 국부침전 특성에 관한 연구 (Study on the Asymmetric Regional Deposition of Airborne Pollutant Particles in the Human Respiratory Tract)

  • 구재학;김종숭
    • 한국대기환경학회지
    • /
    • 제19권5호
    • /
    • pp.551-560
    • /
    • 2003
  • Particle deposition in human lungs was investigated theoretically by using asymmetric five-lobe lung model. The volumes of each of the five lobes were different, thereby forming an asymmetric lung structure. The tidal volume and flow rate of each lobe were scaled according to lobar volume. The total and regional deposition with various breathing patterns were calculated by means of tracking volume segments and accounting for particle loss during inhalation and exhalation. The deposition fractions were obtained for each airway generation and lung lobe, and dominant deposition mechanisms were investigated for different size particles. Results show that the tidal volume and flow rate have a characteristic influence on particle deposition. The total deposition fraction increases with an increase in tidal volume for all particle sizes. However, flow rate has dichotomous effects: a higher flow rate results in a sharp increase in deposition for large size particles, but decreases deposition for small size particles. Deposition distribution within the lung shifts proximally with higher flow rate whereas deposition peak shifts to the deeper lung region with larger tidal volume. Deposition fraction in each lobe was proportional to its volume. Among the three main deposition mechanisms, diffusion was dominant for particles < 0.5 ${\mu}{\textrm}{m}$ whereas sedimentation and impaction were most influential for larger size particles. Impaction was particularly dominant for particles> 8 ${\mu}{\textrm}{m}$. The results may prove to be useful for estimating deposition dose of inhaled pollutant particles at various breathing conditions.

비대칭 입출구를 갖는 장방형공간의 유동특성 (Flow Characteristics of Rectangular Space with Asymmetric Inlet and Outlet)

  • 이철재
    • 해양환경안전학회지
    • /
    • 제12권4호
    • /
    • pp.261-266
    • /
    • 2006
  • 이 연구에서는 실제선박의 후드룸을 1/15로 축소한 비대칭 입출구를 갖는 장방형 모델을 대상으로 가시화 실험을 수행하고 내부의 유동 특성을 고찰하고자 하였다. 속도장의 계측은 CACTUS'2000을 이용한 2차원 PIV기법으로 하였으며 4개의 계측영역을 설정하여 계측한 결과 유동장의 환기구조를 지배하는 흐름은 유동장의 좌측 벽면의 흡기구로부터 대각방향의 우측상부로 흐르는 나선형의 'L'형 유동이었다. 또한 주 흐름의 영향으로 유동장의 중앙부분에 강제와류형태의 재순환 흐름이 존재하였다.

  • PDF

Large scale fire test on a composite slim-floor system

  • Bailey, C.G.
    • Steel and Composite Structures
    • /
    • 제3권3호
    • /
    • pp.153-168
    • /
    • 2003
  • This paper discusses the results and observations from a large-scale fire test conducted on a slim floor system, comprising asymmetric beams, rectangular hollow section beams and a composite floor slab. The structure was subjected to a fire where the fire load (combustible material) was higher that that found in typical office buildings and the ventilation area was artificially controlled during the test. Although the fire behaviour was not realistic it was designed to follow as closely as possible the time-temperature response used in standard fire tests, which are used to assess individual structural members and forms the bases of current fire design methods. The presented test results are limited, due to the malfunction of the instrumentation measuring the atmosphere and member temperatures. The lack of test data hinders the presentation of definitive conclusions. However, the available data, together with observations from the test, provides for the first time a useful insight into the behaviour of the slim floor system in its entirety. Analysis of the test results show that the behaviour of the beam-to-column connections had a significant impact on the overall structural response of the system, particularly when the end-plate of one of the connections fractured, during the fire.

Increase In Mean Alveolar Pressure Due To Asymmetric Airway Geometry During High Frequency Ventilation

  • Cha, Eun-J.;Lee, Tae-S.;Goo, Yong-S.;Song, Young-J.
    • 대한의용생체공학회:의공학회지
    • /
    • 제14권1호
    • /
    • pp.89-96
    • /
    • 1993
  • During high frequency ventilation (HFV), mean alveolar pressure has been measured to increase with mean airway opening pressure controlled at a constant level in both humans and experimental animals. Since this phenomenon could potentiate barotrauma limiting advantages of HFV, the present study theoretically predicted the difference between menu alveolar and airway opening pressures ($MP_{alv}$). In a Weibel's trumpet airway model, approximated formula for $MP_{alv}$ was derived based on momentum conservation assuming a uniform velocity profile. The prediction, equation was a func pion of gas density($\rho$), mean flow rate(Q), and diameter of the airway opening where the pressure measurement was made($D_0$) : $MP_{alv}=4{\rho}(Q/D_0^{2})^2$. This was a result of the difference in crosssectional area between the alveoli and the airway opening. A simple aireway model experiment was performed and the results well fitted to the prediction, which demonstrated the validity of the present analysis. Previously reported $MP_{alv}$ data from anesthetized dogs in supine position were comparable to the predicted values, indicating that the observed dissociation between mean alveolar and airway opening pressures during HFV can be explained by this innate geometric (or cross-sectional area) asymmetry of the airways. In lateral position, however, the prediction substantially underestimated the measurements suggesting involvement of other important physiological mechanisms.

  • PDF

양측 횡격막신경을 침범한 원인불명의 양측 상완신경염 1예 (A case of Idiopathic Bilateral Brachial Neuritis Involving the Bilateral Phrenic Nerves)

  • 곽재혁;이동국;권오대
    • Annals of Clinical Neurophysiology
    • /
    • 제7권1호
    • /
    • pp.28-30
    • /
    • 2005
  • Bilateral brachial neuritis is clinically uncommon and accidentally involvement of bilateral phrenic nerves is rarely reported. We experienced a 26 year old man who developed subacute onset of asymmetric bilateral shoulder and arm weakness. The weakness slowly aggravated and finally suffered from dyspnea due to bilateral phrenic nerve palsy. Cervical spine MRI and CSF study showed no abnormality. Viral markers and other serological test showed no specific finding. Electromyographic study showed bilateral brachial axonal polyneuropathy with cervical and upper thoracic polyradiculopathy. And bilateral phrenic nerve conduction study showed no resopnse. He showed no improvement for 10 months after treatment and managed with continuous artificial ventilation. We report a case of idiopathic bilateral brachial neuritis accidentally involving bilateral phrenic nerves.

  • PDF

Ravitch 술식으로 교정한 누두흉 치험 5예 (Clinical expeerience of funnel chest corrected by ravitch method -5 cases report-)

  • 정황규
    • Journal of Chest Surgery
    • /
    • 제19권4호
    • /
    • pp.699-706
    • /
    • 1986
  • We have experienced 5 cases of Pectus excavatum corrected by Ravitch method without use of K-wire or metal bar from Jan. 1985 to Apr. 1986. All cases were male. The symmetric depression was in 4 cases, asymmetric one was in one case. The chief complaints were dyspnea on exertion, frequent U.R.I. and inferiority. The flail chest was developed in all cases, but it was insignificant in all cases except one who needed assist ventilation. Mediastinitis was developed in one case one week postoperatively but well managed with drainage. A distance from the posterior surface of sternum to the anterior surface of vertebral body was estimated preoperatively and postoperatively. Postoperative result was evaluated as the change of distance postoperatively. The change was 1.5cm minimally to 3.5cm maximally. Late results were "Excellent" in 3 cases and "Good" in 2 cases.uot; in 2 cases.

  • PDF

Anesthetic management in corticobasal degeneration with central sleep apnea: A case report

  • Shionoya, Yoshiki;Nakamura, Kiminari;Sunada, Katsuhisa
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • 제19권4호
    • /
    • pp.235-238
    • /
    • 2019
  • Corticobasal degeneration (CBD) is a rare neurodegenerative disease characterized by dystonia, cognitive deficits, and an asymmetric akinetic-rigid syndrome. Little information is available regarding anesthetic management for CBD patients. Our patient was a 55-year-old man with CBD complicated by central sleep apnea (CSA). Due to the risk of perioperative breathing instability associated with anesthetic use, a laryngeal mask airway was used during anesthesia with propofol. Spontaneous respiration was stable under general anesthesia. However, respiratory depression occurred following surgery, necessitating insertion of a nasopharyngeal airway. Since no respiratory depression had occurred during maintenance of the airway using the laryngeal mask, we suspected an upper airway obstruction caused by displacement of the tongue due to residual propofol. Residual anesthetics may cause postoperative respiratory depression in patients with CBD. Therefore, continuous postoperative monitoring of $SpO_2$ and preparations to support postoperative ventilation are necessary.