• 제목/요약/키워드: Assist device

검색결과 268건 처리시간 0.033초

DLC Emitter 전기적 특성 (Electric properties of DLC Emitter)

  • 이상헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1312_1313
    • /
    • 2009
  • In this study the fabrication technique of the planner field emission device structure with a DLC layer were studied. The bottom Mo electrode using electrochemical method on the DLC layer deposited using assist sputtering.

  • PDF

Analysis of Channel Flow Low During Fuelling Operation of Selected Fuel Channels at Wolsong NPP

  • I. Namgung;Lee, S.K.
    • Nuclear Engineering and Technology
    • /
    • 제34권5호
    • /
    • pp.502-516
    • /
    • 2002
  • Wolsong NPP are CANDU6 type reactors and there are 4 CANDU6 type reactors in commercial operation. CANDU type reactors require on-power refuelling by two remote controlled F/Ms (Fuelling Machines). Most of channels, fuel bundles are float by channel coolant flow and move toward downstream, however in about 30% of channels the coolant flow are not sufficient enough to carry fuel bundles to downstream. For those channels a special device, FARE (Flow Assist Ram Extension) device, is used to create additional force to push fuel bundles. It has been showing that during fuelling operation of some channels the channel coolant flow rate is reduced below specified limit (80% of normal), and consequently trip alarm signal turns on. This phenomenon occurs on selected channels that are instrumented for the channel flow and required to use the FARE device for refuelling. Hence it is believed that the FARE device causes the problem. It is also suspected that other channels that do not use the FARE device for refuelling might also go into channel flow low state. The analysis revealed that the channel How low occurs as the FARE device is introduced into the core and disappears as the FARE device is removed from the core. This paper presented the FARE device behavior, detailed fuelling operation sequence with the FARE device and effect on channel flow low phenomena. The FARE device components design changes are also suggested, such as increasing the number or now holes in the tube and flow slots in the ring orifice.

The effects of providing visual feedback and auditory stimulation using a robotic device on balance and gait abilities in persons with stroke: a pilot study

  • Park, Jae Ho;Chung, Yijung
    • Physical Therapy Rehabilitation Science
    • /
    • 제5권3호
    • /
    • pp.125-131
    • /
    • 2016
  • Objective: The purpose of this study was to investigate the effects of providing visual feedback and auditory stimulation using a robotic device on balance and gait abilities in stroke patients. Design: Randomized controlled pilot trial. Methods: Fifteen subjects were randomly divided into three groups where five subjects were in the visual feedback robotic device assist gait training (VRGT) group, five subjects in the auditory stimulation robotic device assist gait training (ARGT) group, and five subjects in the control group. Subjects received visual feedback and auditory stimulation while undergoing robotic gait training for 45 minutes, three times a week for 2 weeks, and all subjects had undergone general physical therapy for 30 minutes, five times a week for 2 weeks. All subjects were assessed with the Berg balance scale (BBS), timed up and go (TUG) test, and 10-meter walking test (10MWT) pre- and post-intervention. Results: All subjects showed that BBS, TUG test, and 10MWT scores significantly improved post-intervention (p<0.05), and the control group also had significantly improved post-treatment (p<0.05). The VRGT and the ARGT showed significant improvements in BBS, TUG, and 10MWT scores compared with the control group (p<0.05). The VRGT group showed a significant improvement in BBS, TUG, and 10MWT scores compared with the control group (p<0.05). In addition, it has been confirmed that VRGT had significantly improved in BBS, TUG test, and 10MWT scores compared with the auditory stimulation and control group (p<0.05). Conclusions: The results of this study showed improved balance and gait abilities after VRGT and ARGT groups compared with general physical therapy and was found to be effective in enhancing the functional activity of persons affected with stroke.

평균 배기 압력 구배 지수를 이용한 실화 검출 (The misfire detection using the mean exhaust pressure gradient index)

  • 정성원;심국상;김세웅
    • 한국산업융합학회 논문집
    • /
    • 제4권4호
    • /
    • pp.371-378
    • /
    • 2001
  • This paper proposes a method to detect the misfired cylinder using a new misfire detection index. The new method of misfired cylinder is a comparison of pressure gradient during the blowdown period of exhaust stroke. If a misfire occurs, the engine will he lost some power and consumes the more fuel and the torque will be unsteady. Most of all, the misfire affects a bad influence of the 3-way catalyst and emits unburned hydrocarbon in the air. To prevent these unusual phenomena and eliminate the factor of the environmental pollution, it is important to detect the misfired cylinder. To do the experiment, set up the assist device on the manifold. This assist device is not deformed for conventional exhaust manifold and installed in the end of the exhaust manifold. Experimental results showed that the method using the mean gradient pressure index is proven to be effective in the detection of misfired cylinder on gasoline engine regardless loads and revolutions of the engine.

  • PDF

동물실험을 통한 공압식 좌심실보조장치의 평가 (Evaluation of Pneumatic Left Ventricular Assist Device for Animal Experiment)

  • 이혁수;오혜정;이상훈;김삼현;서필원;박성식;이계한;안혁;황승옥
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1998년도 추계학술대회
    • /
    • pp.235-236
    • /
    • 1998
  • The purpose of this paper is to develop diaphragm type pneumatic Left Ventricular Assist Device(LVAD) for clinical application and to evaluate its performance through the mock circulation and animal experiment. The blood housing and diaphragm are made by polyurethane. The relations of cardiac output us. beat rate and cardiac output vs. systolic-to-diastolic rate was estimated through the mock test and hemodynamic waves are recorded for the evaluation of VAD. We performed animal experiment and 4 animals survived more than 24hrs. As a result, the hemodynamic data and waves showed this system can be applicable to the animal experiment.

  • PDF

공압식 심실보조장치의 개발 및 평가 (Development and Evaluation of Pneumatic Ventricular Assist Device)

  • 이상훈;박이태;김삼현;한동선;이학중
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1995년도 춘계학술대회
    • /
    • pp.247-250
    • /
    • 1995
  • The purpose of this paper is to develop diaphragm-type pneumatic ventricular assist device(VAD) for clinical application and to evaluate its performance through the mock circulation system. The blood housing and diaphragm are made by coating pellethane on the metallic mold and the back plate is made by machining process. The relations of cardiac output(CO) vs. beat rate and CO vs. systolic-to-diastolic rate was estimated through the mock test and hemodynamic waves are recorded for the evaluation of VAD. As a result, the volume of blood pump is 70 ml, maximum CO is 5 L/min and CO has a close relation to the input resistance of blood pump. The hemodynamic data and waves showed this system can be applicable to the animal experiment.

  • PDF

어린이 방사선검사 보조기구의 개발 (Development of Children's X-ray Imaging Assist Device)

  • 이도병;서승준;최현우;고철우;김종기
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권4호
    • /
    • pp.243-249
    • /
    • 2020
  • Examination with medical radiography is the most significant advances in medicine in the 21st century. Diagnostic imaging occupies an important position in all medical subjects, surgical and internal medicine, including radiology, orthopedics, and neurosurgery. However, the invention associated with conventional radiography devices has focused only on emphasizing the efficient aspects of the examination or obtaining clearer images without considering the age and disease-induced constraints of the patient's posture. The newly developed X-ray aids to solve this problem can effectively perform X-ray imaging of children's who have difficulty communicating and controlling. It is also thought to be a good way to provide accurate imaging information and minimize radiation exposure for children.

퍼지로직을 이용한 전기유압식 좌심실 보조장치의 유입혈류량 조절 알고리즘의 개발 (Development of an Algorithm for Regulation of Inlet Blood Flow in Electrohydraulic Left Ventricular Assist Device Using Fuzzy Logic)

  • 최재순;최원우;조영호;박성근;민병구
    • 한국지능시스템학회:학술대회논문집
    • /
    • 한국퍼지및지능시스템학회 1995년도 추계학술대회 학술발표 논문집
    • /
    • pp.387-392
    • /
    • 1995
  • 전기 유압식 좌심실 보조장치에서 모터 전류 파형을 정보로 하여 작동기의 이완기 속도를 조절함으로써 좌심방으로부터 유입되는 혈류량을 조절하는 알고리즘을 개발하였다. 좌심실 보조장치(Left Ventricular Assist Device, LVAD)는 허혈성 심장질환 등으로 좌심실 의 혈액 박출 기능이 저하된 환자에게 시술하여 정상 상태의 심박출량을 유지할 수 있도록 하는 보조 혈액 박출 기능이이다. 전기 유압식 좌심실 보조장치에서는 혈액의 유입이 능동 적으로 이루어지므로, 좌심방 함몰로 인한 심근 손상 및 외부 공기 유입으로 인한 색전증을 방지하기 위해 유입혈류량을 현재 좌심방내의 상태에 따라 적절히 조절해 주어야 한다. 좌 심방 내의 혈액량 정도는 혈액을 유입해 내는 작동기의 이완기 동작 시에 소모되는 에너지 크기에 반영되고, 작동기를 구동하는 모터에 들어가는 전류의 크기는 작동기에 공급되는 에 너지에 비례하므로, 이전류 파형의 정보들을 통해 좌심방내의 상태를 추정해 볼 수 있다. 본 논문에서는 퍼지로직을 적용하여 모터 전류 파형의 정보들을 통해 좌심방 내의 상태를 추정 해 볼 수 있다. 본 논문에서는 퍼지로직을 적용하여 모터 전류 파형의 이상 유무를 판단한 뒤 에에 따라 작동기의 이완기 속도를 조절하는 알고리즘을 개발하여 모의순환장치 실험을 통해 그 실효성을 검증한 결과를 정리하였다.

  • PDF