• Title/Summary/Keyword: Assist device

Search Result 268, Processing Time 0.029 seconds

Design and Implementation of a Mobile Web Services for Supporting Dormitory Works (기숙사 업무 지원을 위한 모바일 웹 서비스 설계 및 구현)

  • Kim, Sung Wan;Son, Byeong-Oh;Cho, Yang-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.6
    • /
    • pp.1389-1398
    • /
    • 2013
  • With the rapid increase in supplying and applying of mobile devices major student services in colleges are provided in mobile device-based ones. In this paper we describe a design and implementation of a dormitory works supporting service system based on mobile web to efficiently assist dormitory business and provide student convenient services especially for dormitory type public schools and colleges requiring a strict student management. The proposed system, first, improves the effectiveness of work processing, such as roll call, sleep out handling, in the aspect of business management. Second students satisfaction level is increased as giving them access under Web by providing mobile web environment. We operated the proposed system over a college dormitory living around 250 students for a semester and evaluated its usefulness by conducting a questionnaire survey.

3-D Hetero-Integration Technologies for Multifunctional Convergence Systems

  • Lee, Kang-Wook
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.22 no.2
    • /
    • pp.11-19
    • /
    • 2015
  • Since CMOS device scaling has stalled, three-dimensional (3-D) integration allows extending Moore's law to ever high density, higher functionality, higher performance, and more diversed materials and devices to be integrated with lower cost. 3-D integration has many benefits such as increased multi-functionality, increased performance, increased data bandwidth, reduced power, small form factor, reduced packaging volume, because it vertically stacks multiple materials, technologies, and functional components such as processor, memory, sensors, logic, analog, and power ICs into one stacked chip. Anticipated applications start with memory, handheld devices, and high-performance computers and especially extend to multifunctional convengence systems such as cloud networking for internet of things, exascale computing for big data server, electrical vehicle system for future automotive, radioactivity safety system, energy harvesting system and, wireless implantable medical system by flexible heterogeneous integrations involving CMOS, MEMS, sensors and photonic circuits. However, heterogeneous integration of different functional devices has many technical challenges owing to various types of size, thickness, and substrate of different functional devices, because they were fabricated by different technologies. This paper describes new 3-D heterogeneous integration technologies of chip self-assembling stacking and 3-D heterogeneous opto-electronics integration, backside TSV fabrication developed by Tohoku University for multifunctional convergence systems. The paper introduce a high speed sensing, highly parallel processing image sensor system comprising a 3-D stacked image sensor with extremely fast signal sensing and processing speed and a 3-D stacked microprocessor with a self-test and self-repair function for autonomous driving assist fabricated by 3-D heterogeneous integration technologies.

Real-time Intelligent Exit Path Indicator Using BLE Beacon Enabled Emergency Exit Sign Controller

  • Jung, Joonseok;Kwon, Jongman;Jung, Soonho;Lee, Minwoo;Mariappan, Vinayagam;Cha, Jaesang
    • International journal of advanced smart convergence
    • /
    • v.6 no.1
    • /
    • pp.82-88
    • /
    • 2017
  • Emergency lights and exit signs are an indispensable part of safety precautions for effective evacuation in case of emergency in public buildings. These emergency sign indicates safe escape routes and emergency doors, using an internationally recognizable sign. However visibility of those signs drops drastically in case of emergency situations like fire smoke, etc. and loss of visibility causes serious problems for safety evacuation. This paper propose a novel emergency light and exit sign built-in with Bluetooth Low Energy (BLE) Beacon to assist the emergency self-guiding evacuation using devices for crisis and emergency management to avoid panic condition inside the buildings. In this approach, the emergency light and exit sign with the BLE beacons deployed in the indoor environments and the smart devices detect their indoor positions, direction to move, and next exit sign position from beacon messages and interact with map server in the Internet / Intranet over the available LTE and/or Wi-Fi network connectivity. The map server generate an optimal emergency exit path according to the nearest emergency exit based on a novel graph generation method for less route computation for each smart device. All emergency exit path data interfaces among three system components, the emergency exit signs, map server, and smart devices, have been defined for modular implementation of our emergency evacuation system. The proposed exit sign experimental system has been deployed and evaluated in real-time building environment thoroughly and gives a good evidence that the modular design of the proposed exit sign system and a novel approach to compute emergency exit path route based on the BLE beacon message, map server, and smart devices is competitive and viable.

DESIGN OF A CENTRIFUGAL BLOOD PUMP FOR ECMO DEVICE THROUGH NUMERICAL ANALYSES (수치해석을 통한 ECMO용 원심형 혈액 펌프 설계)

  • Choi, S.;Hur, N.;Moshfeghi, M.;Kang, S.;Kim, W.;Kang, S.H.
    • Journal of computational fluids engineering
    • /
    • v.21 no.1
    • /
    • pp.103-109
    • /
    • 2016
  • With the rapid increase in the number of patients with cardiopulmonary diseases, more cardiopulmonary circulatory assist devices are also needed. These devices can be employed when heart and/or lung function poorly. Due to the critical role they take, these devices have to be designed optimally from both mechanical and biomechanical aspects. This paper presents the CFD results of a baseline model of a centrifugal blood pump for the ECMO condition. The details of flow characteristics of the baseline model together with the performance curves and the modified index of hemolysis(MIH) are investigated. Then, the geometry of baseline impeller and the volute are modified in order to improve the biomechanical performance and reduce the MIH value. The numerical simulations of two cases represent that when impeller radius and prime volume decrease the MIH value also decreases. In addition, the modified geometry shows more uniform pressure distribution inside the volute. The findings provide valuable information for further modification and improvement of centrifugal blood pumps from both mechanical and biomechanical aspects.

A Novel Transmission Scheme for Compressed Health Data Using ISO/IEEE11073-20601

  • Kim, Sang-Kon;Kim, Tae-Kon;Lee, Hyungkeun
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.11 no.12
    • /
    • pp.5855-5877
    • /
    • 2017
  • In view of personal health and disease management based on cost effective healthcare services, there is a growing need for real-time monitoring services. The electrocardiogram (ECG) signal is one of the most important of health information and real-time monitoring of the ECG can provide an efficient way to cope with emergency situations, as well as assist in everyday health care. In this system, it is essential to continuously collect and transmit large amount of ECG data within a given time and provide maximum user convenience at the same time. When considering limited wireless capacity and unstable channel conditions, appropriate signal processing and transmission techniques such as compression are required. However, ISO/IEEE 11073 standards for interoperability between personal health devices cannot properly support compressed data transmission. Therefore, in the present study, the problems for handling compressed data are specified and new extended agent and manager are proposed to address the problems while maintaining compatibility with existing devices. Extended devices have two PM-stores enabling compression and a novel transmission scheme. A variety of compression techniques can be applied; in this paper, discrete cosine transformation (DCT) is used. And the priority of information after DCT compression enables new transmission techniques for performance improvement. The performance of the compressed signal and the original uncompressed signal transmitted over the noisy channel are compared in terms of percent root mean square difference (PRD) using our simulation results. Our transmission scheme shows a better performance and complies with 11073 standards.

Operator Modeling and Design of Fuzzy Controller for a Wire-Driven Heavy Material Lifting System (와이어 구동식 중량물 권양 시스템을 위한 퍼지제어기 설계 및 작업자 모델링)

  • Song, Bo-Wei;Seo, Hyun-Duk;Lee, Yun-Jung
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.5
    • /
    • pp.436-443
    • /
    • 2013
  • This paper presents design methods of a fuzzy controller and an operator model for a wire-driven heavy material lifting system helping human workers. The wire-driven heavy material lifting system is a kind of human-assistive systems in which a human is involved in the control loop. Thus, human's control characteristics and requirement of reducing worker's force to lift a heavy material are considered in the design process of the proposed fuzzy controller. An automatic weight measurement algorithm during the early stage of lifting is also introduced. Finally, the effectiveness and performance of the proposed system are proved by experiments.

Design and Implementation of the Web-based Monitoring System for an Artificial Heart (웹 기반 인공심장 모니터링 시스템의 설계와 구현)

  • 정진한;최재순;이지훈;민병구
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.2
    • /
    • pp.131-137
    • /
    • 2002
  • The remote monitoring system including hemodynamic information and pump status of the implanted animal could be helpful during the in vivo experiment or clinical trial for an artificial heart Implantation. In order to monitor the course of the in vivo experiment continuously and anywhere, web-based remote monitoring system was developed, which can monitor pressures(AoP, LAP, RAP, PAP) and flow information as well as the pump operating conditions. The system consists of data sending, storing viewer part. The data sending part was constructed using component object model and the viewer part was constructed using the Java applet. In addition, the dialog box was introduced to communicate earth other instantly and the alarming function was also introduced when the hemodynamic values were out of the desired ranges. The developed remote monitoring system was applied during the in vivo experiment of the BVAD (Bi-ventricular Assist Device) implantation for 1 month and showed designed work without failure.

Development of Cannula type Electrohydraulic Left Ventricular Assist Device (캐뉼라를 이용한 전기유압식 좌심실 보조기의 개발에 관한 연구)

  • Choi, Jin-Wook;Lee, Kyu-Bak;Koh, Young-Hwan;Kim, Hwoa-Ryoung;Jung, Dae-Young;Kim, Cheol-Sang;Park, Jae-Hyoung;Min, Byoung-Goo
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1991 no.11
    • /
    • pp.70-74
    • /
    • 1991
  • 좌심실보조기의 임상응용범위를 넓히기 위해서 개심술을 하지 않고 좌심실보조기를 적용할 수 있도록 캐뉼라형 좌심실보조기를 이용한 보조순환 실험을 하였다. 좌심실 보조기는 모터의 회전력이 PVC 벨로우즈를 수측, 팽창시키는 전기유압식으로 구동되며 환자는 양쪽 대퇴동맥을 통하여 보조순환을 받도록 되어 있다. 두차례의 동물실험을 통하여 대퇴동맥을 통한 보조 순환방식의 가능성 및 그 효과에 대해서 관찰하였다. 첫 실험은 12kg 개를 이용하여 셀딩거 방법으로 뮬린형 카테터를 디퇴동맥으로 삽입히여, 캐뉼라형 보조순환방법의 가능성을 확인하였고, 두번째 동물실험에서는 내경 4.8 mm의 PVC 카테터를 이용하여 좌심방에 유입카테터를 연결하고 대동맥에 유출카테터를 연결하여 보조순환에 의한 대동맥압의 변화와 혈류량의 변화를 관찰하였다. 보조순환동안 개의 동맥압을 100mmHg로 유지할 수 있었으며, 좌심실내압이 감소하는 것을 관찰할 수 있었다.

  • PDF

Effect of Low Left Atrial Pressure on the Pump Output of Left Ventricular Assist Device (좌심방압 변화가 좌심실보조기 박출량에 미치는 영향에 대한 연구)

  • Choi, J.W.;Lee, S.W.;Jung, C.I.;Kim, H.R.;Lee, Y.K.;Lee, K.H.;Kim, C.S.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.11
    • /
    • pp.141-145
    • /
    • 1992
  • 심부전 환자의 심근회복을 도울 수 있는 장비인 전기유압방식 좌심실보조기를 개발하였다. 좌심실보조기는 혈액펌프, 압력펌프, 제어기로 구성되어 있으며, 혈액펌프에 내장된 혈액주머니는 동물실험을 위하여 50 ml의 크기로 제작하였다. 좌심실보조기의 성능평가를 위하여 최대 박출량을 측정하고 있으나 실험실에서 측정된 간은 동물 실험에서 관찰되는 것보다 일반적으로 증가된 박출량을 보이게 된다. 이는 생체에서는 좌심방의 체적이 박동 주기에 따라 변하여 좌심실보조기가 받아들일 수 있는 유효 혈액량이 변하는 반면, 모의순환장치에서는 좌심방을 단순 저장고로 사용하기 때문에 좌심방의 박동주기에 따른 체적변화를 감안하지 못하여 생기는 것이다. 본 실험에서는 모의순환 장치에 체적변화 가능한 100ml 크기의 좌심방을 연결하여 좌심방으로 들어오는 혈류량이 제한된 동물실험 상황을 모방하였다. 좌심실보조기의 제어방식중 수측기 이완기 비율(SD 비율)변화에 따른 좌심방 음압발생효과를 관찰한 결과 SD 비율을 40 %로 유지하면 행정거리가 클때도 좌심실의 음압발생을 줄일 수 있는 것을 관찰하였다.

  • PDF

Cardiac Decompressing Effect by Delayed Sternal Closure Following Open Heart Surgery in Children (소아에서 개심술후 정중흉골절개의 지연흉골폐쇄에 의한 심장압박 방지효과)

  • 김경환;서경필
    • Journal of Chest Surgery
    • /
    • v.30 no.12
    • /
    • pp.1167-1174
    • /
    • 1997
  • We retrospectively reviewed a series of 20 patients treated with delayed sternal closure during a 5-year period from 1991 to 1996. Of the 2675 patients with cardiovascular su gery 20 underwent this procedure. Male and female ratio was 11:9, mean age was 6.4 months(range 7 days to 5 years). The indications included unstable hemodynamic profiles after open heart surgery due to myocardial edema and poor lung compliance(15), necessity of mechanical ventricular assist device due to weaning failure(3), and hypoxia after PAB(2). Sternum was closed at a mean interval of 102(range 4 to 213) hours after operation. During delayed sternal closure, central venous pressure was elevated(p<0.05). Mediastinitis and other wound problems did not occur. Sepsis developed in 2 patients and microorganism was confirmed in one of the two patients. Five patients died(mortality 25%). And two of 15 discharged patients died during follow-up period. Cumulative survival rate was 65.0% at 12 months and also 65.0% at 24 months.(Standard error was 10.7%) Delayed sternal closure Is considered to be a good method to decompress the hemodynamically compromised heart. Without that, it is not f asible to come off bypass or to decompress the heart. Of course. careful selection of the indication is imperative.

  • PDF