• Title/Summary/Keyword: Ascending aorta

Search Result 263, Processing Time 0.037 seconds

A study of image evaluation and exposure dose with the application of Tube Voltage and ASIR of Low dose CT Using Chest Phantom (흉부 Phantom을 이용한 Low Dose CT의 관전압과 ASIR(Adaptive Statistical Iterative Reconstruction)적용에 따른 영상평가 및 피폭선량에 관한 연구)

  • Hwang, Hyeseong;Kim, Nuri;Jeong, Yoonji;Goo, Eunhoe;Kim, Kijeong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.16 no.2
    • /
    • pp.9-14
    • /
    • 2014
  • Purpose: The purpose of this study has attempted to evaluate and compare the image evaluation and exposure dose by respectively applying Filtered Back Projection(FBP), the existing test method, and Adaptive Statistical Iterative Reconstruction(ASIR) with different values of tube voltage during the Low Dose Computed Tomography(LDCT). Materials and Methods: With the image reconstruction method as basis, Chest Phantom was utilized with the FBP and ASIR set at 10%, 20% respectively, and the change of Tube Voltage (100kVp, 120kVp). For image evaluation, Back ground noise, Signal to Noise ratio(SNR) and Contrast to Noise ratio(CNR) were measured, and, for dose evaluation, CTDIvol and DLP were measured respectively. The statistical analysis was tested with SPSS(ver. 22.0), followed by ANOVA Test conducted after normality test and homogeneity test. (p<0.05). Results: In terms of image evaluation, there was no outstanding difference in Ascending Aorta(AA) SNR and Infraspinatus Muscle(IM) SNR with the different values of ASIR application(p<0.05), but a significant difference with the different amount of tube voltage(p>0.05). Also, there wasn't noticeable change in CNR with ASIR and different amount of Tube Voltage (p<0.05). However, in terms of dose evaluation, CTDIvol and DLP showed contrasting results(p<0.05). In terms of CTDIvol, the measured values with the same tube voltage of 120kVp were 2.6mGy with No-ASIR and 2.17mGy with 20%-ASIR respectively, decreased by 0.43mGy, and the values with 100kVp were 1.61mGy with No-ASIR and 1.34mGy with 20%-ASIR, decreased by 0.27mGy. In terms of DLP, the measured values with 120kVp were $103.21mGy{\cdot}cm$ with No-ASIR and $85.94mGy{\cdot}cm$ with 20%-ASIR, decreased by $17.27mGy{\cdot}cm$(about 16.7%), and the values with 100kVp were $63.84mGy{\cdot}cm$ with No-ASIR and $53.25mGy{\cdot}cm$ with 20%-ASIR, a decrease by $10.62mGy{\cdot}cm$(about 16.7%). Conclusion: At lower tube voltage, the rate of dose significantly decreased, but the negative effects on image evaluation was shown due to the increase of noise. For the future, through the result of the experiment, it is considered that the method above would be recommended for follow-up patients or those who get health checkup as long as there is no interference on the process of diagnosis due to the characteristics of Low Dose examination.

  • PDF

The Clinical Results of Open Heart Surgery with Coronary Artery Bypass Grafting (관상동맥 우회로 조성수술을 병행한 개심수술의 임상성적)

  • 유경종;강면식
    • Journal of Chest Surgery
    • /
    • v.29 no.2
    • /
    • pp.171-176
    • /
    • 1996
  • From March, 1983 to June, 1994, twenty-two patients underwent coronary artery and combined operations. The ages of the patients ranged from 42 years to 72 years (mean 60.4$\pm$8.2 years). There were 17 male and 5 female patients. The left ventricular (LV) ejection fraction ranged from 25% to 65% (mean 46.9$\pm$14.2%). Nine patients had mechanical complication of myocardial infarction (MI), of which 5 were LV aneurysm, 3 ventricular septal defect and 1 mitral regurgitation. Nine patients had rheumatic valvular heart disease of whom 7 with aortic valve disease and 2 with mitral valve disease. Two other patients had left atrial thrombi, only one with atrial septal defect a d another with aneurysm of ascending aorta. An average of 2.1$\pm$1.0 bypasses was done, ranging from one to four. There were 3 postoperative complications; 2 perioperative MI and 1 leg wound infection. Among complicated patients, mortality was 1 patient (4.5%) due to low cardiac output syndrome after perioperative MI. With 3 to 136 months follow-up (mean 41.1$\pm$40.2 months), late mortality was 1 patient due to cerebral vascular accident. Among long-term survivors, all patients are in New York Heart Association functional class I or II. Although the number of patients was small, our surgical results were favorable. Therefore we think that coronary revascularization combined with heart operation does not increase the operative risk when associated coronary artery disease is present, and it reduces the occurrence of late death.

  • PDF

Fine Structure on the Pigment Epithelial Cell and the Bruch's Membrane of the Rat Retina after X-Irradiation (X-선 조사를 받은 흰쥐 망막의 색소상피세포와 기저복합층의 미세구조)

  • Ko, Jeong-Sik;Shin, Ki-Ho;Ahn, E.Tay;Yang, Nam-Gil;Park, Kyung-Ho;Kim, Jin-Gook
    • Applied Microscopy
    • /
    • v.23 no.2
    • /
    • pp.11-26
    • /
    • 1993
  • This experiment was performed to study the morphological responses of the pigment epithelial cell and the Bruch's membrane of the retina of rat following X-ray irradiation. Male rats were divided into normal and experimental groups. The heads of the rats, under sodium thiopental anesthesia, were exposed to 3,000 rads or 6,000 rads of radiation in a single dose, respectively. The source was a Mitsubishi Linear Accelerator ML-4MV. The target to skin distance was 80cm, and the. dose rate was 200 rads/min. The experimental groups were sacrificed on the 6th hour, 2nd and 6th day after X-ray irradiation. Under anesthesia, 1% glutaraldehyde-1% paraformaldehyde solution(0.1M Millonig's phosphate buffer, pH 7.3) was perfused through the left ventricle and ascending aorta. Pieces of the tissue taken from the posterior region of the retina were fixed in 2.5% glutaraldehyde-1.5% paraformaldehyde(0.1M Millonig's phosphate buffer, pH 7.3) and 1% osmium tetroxide(0.1M Millonig's phosphate buffer, pH7.3), and embedded in araldite mixture. The ultrathin sections contrasted with uranyl acetate and lead citrate were observed with JEM 100 CX-II electron microscope. The results were as follow; 1. The morphological changes of the pigment epithelial cells were not pronounced after exposure to 3,000 rads of X-ray. But on the 6th hour after exposure to 6,000 rads of X-ray, bulging nuclear membrane protruding into the cytoplasm and nuclear chromatin clumped into numerous masses along the nuclear membrane were observed. At the 2nd and 6th day post-irradiation, partial cytolysis or necrosis were seen. 2. The thickness of the Bruch's membrane of the experimental groups were increased in the time and dose range covered by this study, and splitting or diffusing basal laminae of the choriocapillary layer were observed frequently in the experimental group. Above results suggest that large amount(6,000 rads) of head irradiation induce direct hazardous effects on the pigment epitherial cells and Bruch's membrane of the retina of the rat, but pigment epithelial cells are more radioresistant than Bruch's membrane.

  • PDF

Right Thoracotomy for Reoperation of Mitral Valve (우측 개흉을 통한 승모판 재수술)

  • 조창욱;구본일
    • Journal of Chest Surgery
    • /
    • v.29 no.12
    • /
    • pp.1342-1346
    • /
    • 1996
  • A right thoracotomy was used for the reoperation or mitral valve of 15 patients who had previously undergone a cardiac operation through a median sternotomy. In our experience. this approach provided dn excellent exposure of the nlitral valve and easy cannulations of both cavie with minimal dissection, ilvoiding any damage of cardiac and major vessels during re-sternotomy Arterial cannulation was performed in the ascending aorta in 13 patients And in the femoral artery in 2 patients. In earlier cases, venous cannulation was done in the SVC And IVC through the right atrium and snared. In later cases, this could be done without snaginly of both cavae or by placing a silgle light-angled catheter into the right atrium. Crystalloid cardioplegic solution was infused for myocardial protection. Hypothermia was controlled at 20\ulcorner$25^{\circ}C$. For defibrillation, internal paddles were used In one patient while sterilized external paddles were used in 10 patients. In the remaining four patients. however. the heart beat spontaneously The respirator could be weaned within 48 hours alter the operation and no pulmonary complication was observed. One out of the 15 patients expired due to sudden attack of ventricular tarchycardid developed ten days after the operation, but the rest of the patients were discharged with good condition.

  • PDF

MDCT Angiography of the Subclavian Artery Thrombosis of the 3D Findings (쇄골하동맥 혈전증에서의 MDCT 혈관조영술의 3D 영상)

  • Kweon, Dae Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.813-819
    • /
    • 2018
  • To demonstrate the 3D usefulness of MDCT, a 73-year-old male patient with subclavian thrombosis was obtained 3D images of maximum intensity projection (MIP), volume rendering, and multiplanar reformation (MPR) to clearly detect and locate the subclavian artery. The data will be provided to the patient for diagnosis and treatment. The scan data were acquired as 3D CT images MIP, volume rendering, curved MPR, and virtual endoscopy images. In the 3D program, the ascending aorta was measured as 364.28 HU, the left carotid artery was 413.77 HU, and the left subclavian artery was 15.72 HU. MIP coronal image shows the closure of the subclavian artery in the left side. Three-dimensional volume images were obtained with 100% permeability and 87-1265 HU. The coronal curved MPR and sagittal curved MPR images show the closure of the subclavian artery due to thrombus using 3D image processing. In the case of subclavian arterial occlusion due to thrombosis, the patient is scanned with MDCT and 3D image processing can be used to confirm occlusion of subclavian artery.

Comparison of the Neurologic Outcome according to the Method of Proximal Graft Anastomosis at the Aortic Side during Off-pump Coronary Artery Bypass Grafting: The Heartstring Sealing System versus Conventional Manual Anastomosis (무심폐기 관상동맥 우회술에 있어서 이식편의 대동맥부 근위부 문합 방법에 따른 수술 후 신경학적 합병증 발생의 비교: 하트스트링을 이용한 방법 대 고식적인 수기 문합술)

  • Cho, Won-Chul;Kim, Joon-Bum;Kim, Hee-Jung;Kim, Hwan-Wook;Kim, Yun-Seok;Jung, Jae-Seung;Choo, Suk-Jung
    • Journal of Chest Surgery
    • /
    • v.42 no.4
    • /
    • pp.441-446
    • /
    • 2009
  • Background: Side clamping of ascending aorta during proximal graft anastomosis in coronary bypassing surgery in-creases the risk of direct aortic injury as well as embolization of intimal atheroma. Heartstring proximal sealing system (Guidant Corporation, Santa Clara, Calif), developed to avoid aortic side clamping, may minimize risks of such complications. The aim of the current study is to compare the surgical outcomes of the two proximal anastomosis techniquesi.e., Heartstring system versus aortic side clamping in off pump coronary bypassing' surgery (OPCAB). Material and Method: From January 2003 to August 2008, 499 patients underwent OPCAB. Of them, proximal graft anastomosis was performed using Heartstring system in 182 patients (Group I) and conventional manual anastomosis in 317 patients (Group II). The two groups were compared for postoperative major complications and mortality. Result: Two groups showed similar characteristics in terms of preoperative demographic data, left ventricular ejection fraction, renal function and history of diabetes, hypertension and smoking. Although there was no inter-group difference in the history of cerebral ischemia (p=0.48), preoperative brain magnetic resonance angiography revealed greater incidence of severe carotid artery stenosis (>75% of lumen) in the Group I than in the. Group II (44.5% in the Group I and 30.0% in the Group II, p=0.003). There were no inter-group differences in postoperative mortality (p=0.40) and complications (p=0.47) including neurologic events (3 in the Group land 2 in the Group II, p=0.258). Whereas neurologic events all comprised transient ischemic attacks in the Group I, they comprised multiple embolic strokes in the Group II. One patient in the Group II experienced aortic dissection during proximal anastomosis which resulted in ascending aortic replacement. Conclusion: Although proximal anastomosis using Heartstring system did not show statistically significant benefit over aortic side clamping, the. absence of embolic stroke maybe a definite benefit which may be better defined through further studies over a larger cohort.

Influence of Anatomy, Associated Anomalies, Age, and Surgical Methods on the Surgical Results of Aortic Coarctation (대동맥교약증 환아의 해부학적 형태, 동반심기형, 연령, 수술방법등이 수술결과에 미치는 영향)

  • 이정렬;김혜순
    • Journal of Chest Surgery
    • /
    • v.30 no.4
    • /
    • pp.363-372
    • /
    • 1997
  • One hundred forty-four patients underwent operation for coarctation of the aorta at Seoul National University Children's Hospital between June 1986 and Decembsr 1995. Age ranged 0.1 to 191 months. Of these 78.5%(113) were infants. We classified the patients in terms of the anatomic location of coarctatiln and the associatCd anomalies(I[401= primary coarctation, 11(741=isthmic hypoplasia, lIIf30)=tubular hypoplasia involving transverse arch, Ar63 =with ventricular septal defect, B(28)=with other major cardiac defects). Subcalvian flap coarctoplasty(60), resection & anastomosis(44), extended aortoplasty(26), and onlay patch(14) were used as surgical methods. Overall operative mortality was 16.0(23/144)%. The hospital mortality was signific'antly higher in patheints with type 111, subtype B, younger age(under 3 months), extended aortoplasty(p(0.01). However, one-stage total repair in patients with subtype A or B were not found to be a predictor of hospital death. Restenosis had occured in 18 patients among 121 survivals(14. 9%). The mean follow-up period was 29.1 $\pm$28.8(0~129.2) months. Preoperative, immediate postoperative(within 3 months after operation) and postoperative(later than 6 months after operation) echocardiographic data on the dimensions of ascending aorta(AA), transverse arch(TA), an4 aortic isthmus(Al) were available in 77 patients(I=20, ll=42, 111= 15). Preoperative and postoperative aortic isthmus(All) and tra sverse arch indices(TAI), defined as TAIAA & AIIAA respectively, were compared. Immediate postoperative All in type 1, II and TAI in type 111 were significantly smaller in stenotic than non-stenotic group suggesting incomplete relieves of stenotic segment Younger age, subclavian coarctoplasty in patient under 3 months of age were round to be the risk factors for restenosis in this series. In conclusion, We found that aortic arch index and transverse arch index can be a useful tool to figure out the anatomic and clinical characteristics of the patients with aortic coarctation, and that anatomy, associated anomalies, age, and surgical methods may influence the surgical outcome of the coarctation repair.

  • PDF

Optimization of Protocol for Injection of Iodinated Contrast Medium in Pediatric Thoracic CT Examination (소아 흉부 CT검사에서 조영제 주입에 관한 프로토콜의 최적화)

  • Kim, Yung-Kyoon;Kim, Yon-Min
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.6
    • /
    • pp.879-887
    • /
    • 2019
  • The purpose of this study is to establish a physiological injection protocol according to body weight, in order to minimize amount of contrast medium and optimize contrast enhancement in pediatric patients performing thoracic CT examinations. The 80 pediatric patients under the age of 10 were studied. Intravenous contrast material containing 300 mgI/ml was used. The group A injected with a capacity of 1.5 times its weight, and groups B, C and D added 5 to 15 ml of normal saline with a 10% decrease in each. The physiologic model which can be calculated by weight about amount of injection of contrast medium and normal saline, flow rate and delay time were applied. To assess image quality, measured average HU value and SNR of superior vena cava, pulmonary artery, ascending and descending aorta, right and left atrium, right and left ventricle. CT numbers of subclavian vein and superior vena cava were compared to identify the effects of reducing artifacts due to normal saline. Comparing SNR according to the contrast medium injection protocol, significant differences were found in superior vena cava and pulmonary artery, descending aorta, right and left ventricle, and CT numbers showed significant differences in all organs. In particular, B group with a 10% decrease in contrast medium and an additional injection of saline showed a low degree of contrast enhancement in groups with a decrease of more than 20%. In addition, the group injected with normal saline greatly reduced contrast enhancement of subclavian vein and superior vena cava, and the beam hardening artifact by contrast medium was significantly attenuated. In conclusion, the application of physiological protocol for injection of contrast medium in pediatric thoracic CT examinations was able to reduce artifacts by contrast medium, prevent unnecessary use of contrast medium and improve the effect of contrast enhancement.

Saphenous Vein Graft as a Composite Graft in Patients Who Are Undergoing Off-pump Coronary Artery Bypass: The Early Results (복재정맥 복합도관을 이용하여 시행한 심폐바이패스를 사용하지 않는 관상동맥우회술의 조기 결과)

  • Hwang, Ho-Young;Kim, Jun-Sung;Choi, Eun-Seok;Lee, Jae-Hang;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.42 no.3
    • /
    • pp.324-330
    • /
    • 2009
  • Background: The long term patency of the free saphenous vein graft, which is the most commonly used conduit, anastomosed to the ascending aorta has been reported to be lower than that of arterial grafts. We evaluated early clinical outcome and the angiographic patency of the saphenous vein composite graft based on the left internal thoracic artery, and compared these results with those of using arterial composite grafts. Material and Method: From September 2006 to October 2008, 419 patients underwent off-pump coronary revascularization. Among those, 295 patients (70.4%) were revascularized using composite grafts (group I: saphenous vein composite graft, n=71, group II: arterial composite graft, n=224). The clinical results were compared between the 2 groups. Early postoperative coronary angiograms were performed in all the patients. ($1.6{\pm}1.6$ days) Result: The number of the distal anastomosis per patient was $3.5{\pm}1.0$ and $3.1{\pm}0.8$ in group I and II, respectively (p=.002). The operative mortality (n=2, 0.7%) and postoperative complications such as atrial fibrillation (n=73, 24.7%), perioperative myocardial infarct (n=6, 2.0%), acute renal failure (n=6, 2.0%), reoperation for bleeding (n=5, 1.7%), cerebrovascular accident (n=3, 1.0%), and mediastinitis (n=1, 0.3%) were not related with the use of saphenous vein graft. Early coronary angiograms revealed a 96.9% (126/130) for the saphenous vein grafts and a 98.8% (479/485) for the composite graft in group II (p=.231). Conclusion: Our data suggested that a saphenous vein graft might be used as analtemative conduit to the arterial graft for constructing a composite graft, as based on our early clinical and angiographic results. Further study is required to establish the long-term efficacy of using a saphenous vein as a composite graft.

Results of Surgical Management in Patients with Cardiac and Arterial Manifestations of Behcet's Syndrome (심장 및 동맥계를 침범한 베체트씨 증후군 환자의 수술 후 결과)

  • 원종윤;장병철;이도연;박상준
    • Journal of Chest Surgery
    • /
    • v.35 no.1
    • /
    • pp.36-42
    • /
    • 2002
  • Background: To evaluate the efficiency of surgical treatment in patients with cardiac valvular and arterial involvement of Behcet's syndrome. Material and Method: 12 patients underwent surgical treatment due to the valvular heart diseases and the various arterial diseases associated with Behest's syndrome over 7 years; 6 with valvular heart disease, 1 with annuloaortic ectasia, 1 with ascending aortic aneurysm, 4 with pseudoaneurysms in abdominal aorta(n=2), carotid artery(n=1), and popliteal artery(n=1). All 12 patients had received valvular replacement(n=6) and the artificial(n=5) or autologous(n=1) graft interposition. We followed the results of these surgical treatments. Result: Operations were technically successful in all 12 patients and peri-operative complication was not demonstrated. However, 10 patients had recurrences; 6 with valvular dehiscence, 3 with pseudoaneurysm at anastostomosis site, and 1 with aorto-duodenal fistula. The duration of recurrence was 1 to 55 months(mean: 15.7$\pm$ 16.2 months). 7 patients underwent the second operation and among them, 4 patients showed repeated recurrences. Overall, 5 patients died 2 to 25 months after the operation(mean: 13.6 months), because of the bleeding at the anastomosis site Five patients did not present recurrence after the first(n=2) or the second operation(n=3) and their follow up duration was 5 to 60 months(mean: 45.8$\pm$41.7 months). Five patients received immune-suppressive therapy after the first(n=2) and second operation(n=3). Three did not shown recurrence for the 13, 29 and 33 months. Conclusion: Post-operative prognosis of arterial manifestation of Behcet's syndrome was not encouraging and if possible, other treatment strategy should be considered.