• 제목/요약/키워드: Asbestos-cement slate roof

검색결과 6건 처리시간 0.02초

공장과 주택 슬레이트지붕의 석면 노출특성 비교 (Comparison on the Releasing Characteristics of Asbestos Fiber from Plant Slate Roof and House Slate Roof)

  • 정재원;유은철;이상준;박근태
    • 한국환경과학회지
    • /
    • 제24권7호
    • /
    • pp.927-937
    • /
    • 2015
  • This study was performed to identify and quantify the asbestos fibers released from two types of asbestos-cement slate roofs. One is a plant roof installed in 1987 which contained 15% chrysotile, and the other is a residential roof installed before 1983 which contained 12% chrysotile. The concentrations of asbestos fibers in air surrounding asbestos-cement slate roofs and in the falling water harvested from the same roofs on rainy days ranged from 0.0012 to 0.0018 f/mL and from 1,764 f/L to 10,584 f/L, respectively. The concentration of inorganic fibers in the soil around asbestos-cement slate roofs was from 217 to 348 f/g. With the above results, the excess lifetime cancer risk (ELCR) for the risk assessment of the asbestos fibers released from asbestos-cement slate based on US EPA IRIS (Integrated risk information system) model is within 5.5E-06 ~ 6.5E-06 levels which indicates that the levels do not exceed "the acceptable risk(1.0E-05)" recommended by WHO. The asbestos concentration in air, drained rainfall and soil around the plant slate roof was higher than that around residential slate roof, but the excess lifetime cancer risk (ELCR) from residential slate was higher than that from plant slate. This suggested that the enclose and encapsulation of residential roofs have priority in removal policy to minimize the exposure risk.

슬레이트 지붕의 설치년도와 면적에 따른 공기 및 유출 빗물 중의 석면 농도 (Asbestos Concentrations in Ambient Air and Drained Rainwater from Slate Roofing by Construction Year and Roof Area)

  • 장봉기;류제영;탁현욱;송수진;이종화;이강호;최재호
    • 한국산업보건학회지
    • /
    • 제23권3호
    • /
    • pp.196-204
    • /
    • 2013
  • Objectives: The purpose of this study is to analyze the number and influence factors of asbestos fibers in the air of farmhouses with asbestos cement slate roofing, as well as in rainwater per unit area of the asbestos cement slate roofing. Methods: At a distance of 1 m from the end of asbestos cement slate roofing in 20 farmhouses, the asbestos fiber in the air was collected three times on a clear day downwind from the prevailing wind. Rainwater falling from the slate roofing was collected four times with a 1.05-m rainwater pipe on a rainy day at the 20 farmhouses, filtered with a MCE filter, and analyzed with a phase contrast microscope. Results: The geometric mean of the number of asbestos fibers in the air of farmhouses with slate roofing was 0.11 fiber/L, and no samples exceeded the recommended standard of 10 fiber/L. As a result of multiple regression analysis, a factor which gave a significant influence to the asbestos fiber content in the air was the gross area of slate roofing at the target farmhouses. The number of asbestos fibers included in rainwater collected per 1 m2 of slate roofing was 1,753 fiber/$L{\cdot}m2$. As a result of multiple regression analysis, the number of asbestos fibers contained in rainwater per 1 m2 of slate showed a significantly higher tendency as the year of slate roofing installation at the target farmhouses receded. Conclusions: It was confirmed for the first time in Korea that asbestos from asbestos cement slate roofing scatters into the air.

슬레이트 지붕 노후화에 따른 석면 섬유 방출량 (Releasing of asbestos fibers from the weathered asbestos cement slate roofing)

  • 김현욱;박계영;한진구;한영선;황범구;이준혁
    • 한국산업보건학회지
    • /
    • 제20권2호
    • /
    • pp.88-93
    • /
    • 2010
  • To confirm and quantify asbestos fibers released from the asbestos-cement slate roofs due to weathering, three houses, selected based on the year of built - 60's, 70, and 80's, were investigated. All of them were located in the downtown of Seoul. Rain or snow-melt water was collected from the roof in a 3.5 liter plastic bottle. A known amount of collected water was filtered on the 37 mm membrane filter, ashed in a muffle furnace, and subsequently treated with HCl to remove organic material. The treated remaining was refiltered on a 25mm membrane filter for PLM and PCM analyses. The NIOSH 7400 method was utilized for PCM counting. In addition, SEM/EDX was used to confirm the asbestos types. The results of this study showed that chrysotile fibers were confirmed by PLM in all samples analyzed. A significant amount of asbestos fibers were found in the water samples. The ranges of asbestos fibers counted from the samples collected in the 60's, 70's, and 80's were; 10,406.3~55,575.6 f/L, 5,218.8~38,126.2 f/L, and 2,906.3~7,798.6 f/L, respectively. As anticipated, concentrations of asbestos fibers increased with time of installment of the roofing material. We conclude that weathering can be a significant factor on the release of asbestos fibers from the asbestos cement products. Since asbestos fibers released into environment can be a source of significant health hazard, countermeasures, such as replacement, removal, and encapsulation of weathered asbestos slate, should be initiated immediately.

동해 구 삼척개발 사택의 건립과 건축적 특징에 관한 조사연구 -등록문화재 A호와 2·3호 사택을 중심으로- (A Research Study on the Architectural Characteristics of old Samcheok Construction Company Housing in Donghae City -focused on A and No. 2·3 Houses as Registered Cultural Properties-)

  • 김태영
    • 한국농촌건축학회논문집
    • /
    • 제17권1호
    • /
    • pp.19-26
    • /
    • 2015
  • The old Samcheok construction company housing in Donghae City was built for employees of Nitrogenous lime factory with railway construction in 1939. The 31 company houses are arranged in a rows including a House A, two No. 2 and 3 Houses, a dormitory, 12 row houses of two households, and 15 row houses of four households. At present, they are preserved with prototype at that time of building as a private company. Researching the architectural characteristics from A and No. $2{\cdot}3$ detached houses of them, the results are as follows. The tea room, living room, and kitchen are centralized and connected with toilet, bathroom, and maid's room by corridor. The exterior wall was finished with paintwork on cement mortar on stud wall framing plastered. The key exterior elements such as diamond shaped asbestos slate, large openings, corner bay window, lintel cornice are in accordance with drawings that they were first designed. The wooden roof structure is based on the structure that supports transverse load with a beam and beam plate instead of thrust. The kitchen and toilet are remodelled and only seem to be a mere shadow of their former self, but the position of sink and toilet bowl is the same as before.

국가등록문화재로 지정된 옛 담장의 정비 양상 (A Study on Structural Maintenance of 'Old Wall' Designated as National Registered Cultural Heritage )

  • 소현수;정명석
    • 한국전통조경학회지
    • /
    • 제41권1호
    • /
    • pp.21-34
    • /
    • 2023
  • 본 연구는 13개 마을 옛 담장의 국가등록문화재 지정 당시 사용된 재료와 축조법을 파악하고, 현장조사를 중심으로 정비에 따른 옛 담장의 구조별 변화 양상을 고찰하였다. 연구의 결과는 다음과 같다. 첫째, 옛 담장은 토석담 10개소와 돌담 5개소로 구성되었으며, 지정 당시 자연석 메쌓기로 막쌓은 돌담은 비슷한 형태를 유지하는 비율이 높았지만, 토석담은 사용한 돌과 줄눈 및 맞댄 면 축조법에 따라서 담장별로 다양하게 변형되었다. 둘째, 옛 담장의 정비로 인해서 변화된 구간을 추출하고 재료의 대체와 첨가, 축조법의 변형 양상을 파악하였다. 지붕부는 내구성과 가격의 효율이 높은 시멘트 기와나 석면 슬레이트로 대체되고, 우수 유입을 막고자 한식 기와에 와구토가 첨가되었다. 벽체부의 자연석은 시공 편의에 따른 발파석, 마름돌, 가공 석재로 대체되고, 보수에 시멘트 블록, 시멘트 벽돌이 사용되었으며, 시멘트 모르타르가 도포되었다. 토석담의 막쌓기가 빗쌓기로 변형되고 찰쌓기는 메쌓기로 바뀌어 경관적, 구조적 문제를 야기하였다. 또한 기초부에 시멘트 모르타르층이 시공되어 자연석 메쌓기로 유도했던 우수의 흐름을 막아버렸다. 셋째, 이러한 정비 양상은 주거공간에 배치된 옛 담장의 속성상 소유주가 일상적 훼손에 대한 비전문적 보수를 반복하고, 문화재 지정으로 인하여 정비를 담당한 수리업체가 지역 재료를 수급하기 어려우며, 옛 담장에 대한 차별성있는 수리시방서가 적용되지 않는 환경에서 기인한다고 판단된다.

일부 학교 건축물의 석면함유 건축자재(ACM) 특성과 위해등급에 관한 연구 (A study of asbestos containing material characteristics and grade of risk assessment in schools, Korea)

  • 정준식;박형규;송혜숙;이원정;김윤신;전형진
    • 한국산학기술학회논문지
    • /
    • 제16권7호
    • /
    • pp.5029-5037
    • /
    • 2015
  • 본 연구의 목적인 우리나라 일부 학교의 석면함유 건축자재을 조사하고 EPA AHERA rule과 ASTM rule을 적용하여 위해성평가를 실시하였다. 총 100개 학교를 2010년 1월부터 12월까지 조사하였다. 건축년도에 따른 ACM 검출율은 1980년대 이전 건축물은 100%, 1990년대 이전은 94.1%, 2000년대 이전은 100%, 2000대 이후는 62.5%로 나타났다. 학교별 ACM 검출율은 유치원과 고등학교는 100%, 초등학교는 97.1%, 중학교는 92.9%, 특수학교는 80%로 나타났다. 천장 텍스는 2~8 %의 백석면과 갈석면, 밤라이트 보드는 6~11 %의 백석면이 검출되었다. 또한 개스킷과 슬레이트 지붕은 각각 16~17 %, 10~13 %의 백석면이 검출되었다. EPA AHERA rule을 이용하여 ACM의 위해성 평가를 실시한 결과, 모든 건축자재는 "Pool" 등급이 나왔으며, ASTM rule 평가에서는 모든 ACM이 "Q&M program"이 필요한 것으로 나타났다.