• Title/Summary/Keyword: Asbestos wastes

Search Result 9, Processing Time 0.023 seconds

An experimental study on the low temperature melting treatment of waste asbestos for using (폐석면의 활용을 위한 저온 용융처리에 대한 실험적 연구)

  • Song, Tae Hyeob;Kim, Young Hun;Park, Ji Sun;Lee, Sea Hyun
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.2
    • /
    • pp.83-90
    • /
    • 2010
  • As a reinforced fabric, asbestos has been utilized as a fire-resistant material as it has a superior flexural stiffness and heat resistance up to $1500^{\circ}C$. However, due to its harmfulness, its use has been prohibited recently and the even the installed asbestos materials are being repaired or supplemented if there is a concern about flying. Asbestos is mainly used for construction panels as a reinforced fabric and coating materials to ensure the fire-resistance of steel frames. Asbestos was used as fire-resistant materials for steel frames until 1991 and then prohibited as Act on Industrial Safety and Health limits the concentration of asbestos in the air. Classified as a designated waste according to Act on Waste Control, asbestos must be buried if there is no possibility of flying (panel-type materials) or cement-solidified and then buried if there is a possibility of flying (spray coating material) In general, it is required that a new waste landfill include a certain landfill facility for designated waste, but in reality there is an absolute storage of landfill facilities for designated waste as they only install facilities of the size required by the regulations. This could result in the 2nd environmental pollution as they cannot process asbestos wastes which will be generated in large volume in the future. This study explores a method that melts asbestos wastes at $700^{\circ}C$ rather than cement-solidifying the waste asbestos from construction sites, especially asbestos-containing spray coating. The study results showed that there was no change in the composition and shape even though asbestos wastes was melted at $1300^{\circ}C$, but there was a change for the specimen which was process in advance for low temperature melting and then melt at $900^{\circ}C$.

  • PDF

The Patent Analysis of the Treatment Technology of Asbestos Wastes (석면 폐기물 처리 특허기술 분석)

  • Kim, Jong-Heon;Cho, Jin-Dong;Lee, Sang-Kwon;Cha, Seong-Ki
    • Economic and Environmental Geology
    • /
    • v.44 no.5
    • /
    • pp.451-462
    • /
    • 2011
  • Asbestos or its applications have been used for long times and for various purposes in our life because of their merits, namely fire resistance, electric insulation and chemical resistance capacity etc. Despite of theses many merits, one of the problems of asbestos is shown toxicity according to its fiber type. So we need data to solve about this problem. In this paper, we study on the technical method of asbestos waste treatment and on the trends of asbestos researches and developments by the analysis of its patents and DWPI database materials. As a result, the asbestos-waste treatment data in the its related patents is used 267 cases to analyze. These data are divided into 86(32.5%) cases of solid waste disposal(B09B). 41(16.6%) cases of separation(B01D) and 27(10.2%) of lime, magnesia, slag, cement and their composites(C04B).

Assessment of asbestos exposure level of workers handling waste containing asbestos (석면함유폐기물 취급근로자의 석면노출수준 평가)

  • Jeong, Jee Yeon;Kim, Eun Young
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.2
    • /
    • pp.135-143
    • /
    • 2018
  • Objectives: There have been many studies on exposure assessment of workers at companies using asbestos as a raw material and at sites of the removal of materials containing asbestos. However, no research has been carried out on the asbestos exposure of workers in industries involving asbestos-containing waste, such as workers at collection and transportation service companies, mid-treatment companies(solidification of asbestos-containing waste), and landfill sites. The objective of this study was to assess the asbestos exposure concentrations of workers in industries handling waste containing asbestos. Methods: For this study, we carried out field investigations at 15 companies: seven collection and transportation service companies, three mid-treatment companies, and five final treatment companies(landfill sites). We took both personal and area samples. Results: The range of asbestos exposure levels of workers handing asbestos-containing wastes at collection, mid-treatment, and landfill companies were 0.000 fibers/cc-0.009 fibers/cc, 0.000 fibers/cc-0.038 fibers/cc, and 0.000 fibers/cc-0.024 fibers/cc, respectively. Conclusions: The asbestos exposure levels of workers at mid-treatment companies were higher than those at collection and transportation companies and at final treatment companies. In the case of collection and transportation workers, the possibility of exposure to levels exceeding those found in the present study is not particularly high considering the characteristics of the work. However, in the case of intermediate or final disposal workers, it is considered that there is a possibility of exposure to levels above those found in this study.

Study on the Detoxification of Asbestos-Containing Wastes (ACW) Using SiC Plate (SiC 플레이트를 이용한 석면 함유 폐기물의 무해화 연구)

  • Hong, Myung Hwan;Choi, Hyeok Mok;Joo, So Young;Lee, Chan Gi;Yoon, Jin-Ho
    • Resources Recycling
    • /
    • v.29 no.1
    • /
    • pp.35-42
    • /
    • 2020
  • Even asbestos-containing waste (ACW) are highly harmful to humans, it continues being produced due to the massive disposal of asbestos-containing products. A development of asbestos detoxification and recycling technologies is required. Heat treatment using microwave is the most efficient method for ACW detoxification. However, microwave heat treatment method has the limitation that asbestos does not absorb microwave at room temperature. That is why, in this study, ACW was detoxified by microwave heat treatment adding the ACW between SiC plates, which are inorganic heating elements that absorb microwaves at room temperature. In order to improove the heat transfer, ACW was crushed and pulverized and then heated using microwave. Microwave heat treatment temperature and time variables were adjusted to investigate the detoxification properties according to heat treatment conditions. After heat treatment, treated ACW was analyzed for detoxification properties through crystal structure and microstructure analysis using X-ray diffraction (XRD) and scanning electron microscopy (SEM). Microwave heat treatment method using SiC plate can be heated up to the target temperature within a short time. Finally, complete asbestos detoxification was confirmed from the crystal structure and the microstructure when the microwave heat treatment was performed at 1,200℃ for at over 60 minutes and at 1,300℃ for at over 10 minutes.

A Study on the Estimation about Aomunt of the Amelioration Districts for Optimum Process of Designated Wastes (적정처리를 위한 주거환경개선지구 내 구조형태별 지정폐기물 발생량 예측에 관한 연구)

  • Shin, Yong-Chul;Son, Byeung-Hun;Hong, Won-Hwa;Lee, Jae-Sung
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2008.04a
    • /
    • pp.285-290
    • /
    • 2008
  • Recently, the scale of the construction work has been increased due to the revitalization of the construction industries. therefore, the demolition work in downtown areas is increased too. Amelioration districts are deteriorating rapidly since it followed the policy which allowed a large number of constructions in a very short period of time. therefore, the quantity of construction wastes and the designated wastes such as asbestos are increased. This study was classifying and analyzing the constructions in amelioration districts to estimate quantity of the designated wastes and the unit of the designated wastes. According to the results of this research, the average annual designated wastes was increased up to 2.59% in comparison with 2,779,334 ton in 2000, there came out 3,151,653 ton of designated wastes in 2005. For the appropriate disposal of increasing designated wastes, it is necessary to study exact estimation of the quantity of wastes.

  • PDF

Friction and Wear Characteristics of Friction Material from Scrap Tire and Potassium Hexatitanate (폐타이어분말과 육티탄산칼륨를 이용한 마찰재의 마찰.마모 특성)

  • Park, Jong-Il;Kang, Dong-Heon;Kang, Suck-Choon;Chung, Chan-Kyo;Chung, Kyung-Ho;Hong, Young-Keun
    • Elastomers and Composites
    • /
    • v.36 no.1
    • /
    • pp.3-13
    • /
    • 2001
  • To resolve environmental problem of waste tire and asbestos and also to capitalize the wastes, we developed a new kind of friction material using scrap tire, potassium hexatitanate, filler, and friction modifier in which rubber made a continuous phase. The material containing 5, 20, 10, 20phr of potassium hexatitanate, phenol, friction modifier, $BaSO_4$, respectively showed good friction properties, high and stable coefficient or friction, and low wear rate.

  • PDF

A Study on the Properties of the Dual-mode Plasma Torch System for Melting the Non-conductive Waste (비전도성 폐기물 용융처리를 위한 혼합형 플라즈마토치 시스템 특성 연구)

  • Moon, Young-Pyo;Choi, Jang-Young
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.1
    • /
    • pp.73-80
    • /
    • 2016
  • The preliminary test for the dual mode plasma torch system was carried out to explore the operation properties in advance. The dual mode plasma torch system that is able to operate in transferred, non-transferred, or dual mode is very adequate for melting the mixed wastes including nonconductive materials such as concrete, asbestos, etc. since it exploits both the high efficiency of heat transfer to the melt in transferred mode and stable operation in non-transferred mode. Also, system operation including restarting is reliable and very easy. A stationary melter with a refractory structure was designed and manufactured considering the melting behavior of slags to minimize the refractory erosion. The power supply for the dual mode plasma torch system built with high power insulated gate bipolar transistor (IGBT) modules has functions for both current control and voltage control and is sufficient to suppress the harmonics during the operation of the plasma torch. The power supply provides two different voltages for transferred operation and non-transferred. It is confirmed that the operation voltage in transferred is always higher than non-transferred. The dual mode plasma torch system was successfully developed and is under operation for a melting experiment to optimize operation data.

An Interdisciplinary Approach for the Solution of Enviromental polution (環境汚染의 解決을 위한 綜合科學的 接近方法 (I))

  • Sin, Hyeon-Deok
    • Journal of the Korean institute of surface engineering
    • /
    • v.12 no.3
    • /
    • pp.207-216
    • /
    • 1979
  • Environmental pollution or contaminations caused by various kinds of pollutants have become one of most serious problems of our time. Environ mental pollution is the unfavoralble alteration of our surroundings, through direct or indirect effects of changes in energy patterns, rediation levels, chemical and physical constitution and abundances of organisms. These changes may affect humans directly or through their supplies of water and of agicultural and other biological products, their physical objects or possessions, or their opportunities for recreation and appreciation of nature. Pollutants that meet the criteria of this definition of environmental pollution are numerous: gases (such as sulfur dioxide and nitrogen oxides) and paniculate matter (such as smoke particles, lead aerosols, and asbestos) in the atmosphere; pesticides and radioactive isotopes in the atmosphee and in waterways; sewage, organic. chemicals, and phosphates in water; solid wastes on land; excessive heating (thermal pollution) of rivers and lakes; and many others. Some of these pollutants are introduced into the environment naturally, others by human actions, and most in both ways. Our major concer is with environmental pollution resulting wholly or largely as a by-product of human activities, because these can be controlled most readily. Environmental pollution cannot be solved by science and technology alone. It should be handled by an interdisciplinary approach with combined methods of science and technology as wen as social science disciplines for the better solution of this critical problem. In this respect, introducing "Environmental Science," a new scientific approach for the solution of environmental problems, which is now widely accepted by most developed countries of the world will be very helpful for systematization of theoretical basis for a new scientific approach to environmental pollution. Environmental science is "the study of all systems of air, land, water, energy, and life that surround Man. It includes all sciences directed to the system-level of understanding of the environment, drawing especially upon such disciplines as meteorology, geophysics, oceanography, and ecology, and utilizing to the fullest knowledge and techniques developed in such fields as physics, chemistry, biology, mathematics and engineering as well as many social science disciplines, such as economics, such as economics, law, political science and public administration." The components of this discipline are not new, for they are drawn from existing areas of science within biology chemistry, physics, and geoscience. What is really new about environmental science, however, is it siewpoint - its orientation to global problems, its conception of the earth as a set of interlocking, interacting systems, and its interest in Man as a part of these systems.

  • PDF

ESTIMATING THE VOLUME OF CONSTRUCTION-WASTE LANDFILL USING GEOPHYSICAL TECHNIQUES (물리탐사 기법을 이용한 건축 폐기물 매립지의 규모 파악)

  • Mun,Yun-Seop;Lee,Tae-Jong;Lee,Chae-Yeong;Yun,Jun-Gi
    • Journal of the Korean Geophysical Society
    • /
    • v.6 no.1
    • /
    • pp.13-23
    • /
    • 2003
  • Dipole-dipole resistivity and ground penetrating radar(GPR) surveys were performed on an abandoned landfill site filled with asbestos containing material. The main purpose of the study was to estimate spatial extension and volume of the landfill for evaluting the cost for developing appropriate remedial alternatives. Assuming that the bedrock is within 10 m depth, dipole spacings of 2, 2.5 and 5m were set for six survey lines for resistivity measurements. For More detailed information, GPR suvey using 225 Mhz antenna was carried out for twelve survey lines for the shallower information. DC resistivity structures showed few tens ~ hundreds ohm-m for the landfill or alluvial laver, and 1,000~ 5,000 ohm-m for the bedrock. The depth to bedrock is found out to be approximately 5m. GPR survey results represented very clear reflection and/or diffraction events from the boundaries as well as from the blocky construction wastes. With high-resolution GPR survey, depth of the bedrock was resolved up to 2m, which in turn, could be a good indicator for estimating the volume of the landfill. Those depths of bedrock were confirmed by backhoe excavation data for 13 sites. The total area and volume of the landfill were to be approximately 3,953 .$m^2$ and 4,033 $m^3$, respectively.

  • PDF