• Title/Summary/Keyword: Asbestos Building Materials

Search Result 30, Processing Time 0.03 seconds

An Asbestos Risk Assessment and Areal Distribution of Asbestos Containing Materials in Public Buildings (석면함유 공공 건축물의 위해성 평가 및 면적 분포 특성)

  • Song, Su-Jin;Jang, Bong-Ki;Jo, Bong-Hyun;Kim, Yeong-Ji;Heo, Eun-Hyeop;Lee, Joung-Dae;Son, Bu-Soon;Lee, Jong-Wha
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.3
    • /
    • pp.267-276
    • /
    • 2016
  • Objectives: This study, aims to examine the distribution characteristics of asbestos-containing building materials; risk assessment and area of distribution of asbestos-containing building materials depending on year of construction; building materials; types of building materials; and usage in public buildings in order to create fundamental data for safe management of public buildings. Methods: The asbestos investigation was conducted by an asbestos research institution from March to May 2014, targeting 41 public buildings which were subject to asbestos investigation in South Chungcheong-do Province. With respect to 381 presumed asbestos-containing materials, an investigation was conducted into whether they contained asbestos, asbestos type, content, year of construction, and use in the building were examined, and a risk assessment was performed. Results: Asbestos-containing building materials were used in 35 buildings(85.4%). Among them, 31(88.6%) were public buildings. Asbestos was detected in 73% of 381 suspected asbestos-containing materials, which were mostly ceiling materials (85.2%). The older the buildings, the more they showed a tendency to have a significantly higher risk assessment score. The ratio of average area with asbestos-containing building materials to total floor area was 57.6%, 44.1%, and 17.8% for buildings built in the 1980s, 1990s, and 2000s, respectively. This showed a tendency to be significantly higher with the age of the building. Conclusions: From the results above, it can be concluded that with the age of the buildings, the risk assessment score and the ratio of average area with asbestos-containing building materials to total floor area became significantly higher. Given the concern about the exposure to asbestos of residents and civil petitioners, safety management of older public buildings and measures for dismantling and removal of asbestos-containing building materials should therefore be urgently established.

A Study on Types and Contents of Asbestos in Bulk Samples (국내 석면 고형시료 중 석면의 종류 및 함유량에 관한 연구)

  • Choi, Ho-Chun;Ahn, Sun-Hee;Hong, Jwa-Ryung;Jeon, Bong-Hwan;Lee, Young-Pil;Park, Chung-Yill
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.21 no.4
    • /
    • pp.201-208
    • /
    • 2011
  • Objectives: According to the compliance of the asbestos-related regulation, every building has to be inspected for asbestos presence before its abatement work. This study was performed for identifying the types and contents of asbestos in building bulk samples. Materials and Methods: Bulk samples were collected during the asbestos inspection in 2010. We grouped the bulk samples into the regulated asbestos containing materials(RACM), presumed asbestos containing materials(PACM), and construction products. Additionally, the types of asbestos in all bulk samples were identified by polarization microscopy(PLM). Results: The RACMs were from building, house, pipe and facility. The RACMs were found mainly building (72.1%) and house (93.7%). The contents of chrysotile in building, house and facility were 66.9% (1-90%), 89.7% (2-90%) and 11.0% (2-90%), respectively. PACMs were surfacing material, thermal system insulation (TSI), and miscellaneous material. The miscellaneous materials that showed a high detection rate (79.2%) were ceiling, roofing and wall materials. Among them, the roofing materials had high chrysotile content(9.7%, 2-21%), followed by wall (8.7%, 2-21%) and ceiling (3.4%, 1-17%). In the construction products, asbestos was found mainly in slate (92.6%, 2-21%), including chrysotile. The slate had high asbestos content (9.7%, 2-21%), followed by cement flat board (8.7%, 2-19%) and textile (3.4%, 1-17%) Conclusions: Utilizing these results, it would be contributed to construct a useful ACM database and prevent from asbestos exposure to workers in the asbestos abatement and maintenance works.

Airborne Asbestos Fiber Concentration in Korean Asbestos-Related Industry from 1994 to 2006 (1994년부터 2006년까지 한국 석면취급 사업장의 석면 노출농도)

  • Yi, Gwangyong;Shin, Yong Chul;Yoon, Chungsik;Park, Dooyong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.23 no.2
    • /
    • pp.123-136
    • /
    • 2013
  • Objectives: This paper was prepapred to report airborne asbestos fiber concentrations in asbestos textile, brake-lining, commutator, and building materials manufacturing industries, and some other asbestos related industries in Korea from 1994 to 2006. Methods: Airborne asbestos data that have been sampled and analyzed in the above industries during 1994-2006 were collected. These data were reviewed to scrutinize the qualified data based on the records such as sampling and analyzed method and quality control procedures. All asbestos data were generated using the National Institute for Occupational Safety & Health (NIOSH) Method 7400. Results: Average concentration of asbestos fiber was 2.14 fibers/cc(0.02-15.6 fibers/cc) in the asbestos textile industry, 0.26 fibers/cc(0.01-1.01 fibers/cc) in the building-materials industry, 0.15 fibers/cc(0.01-0.93 fibers/cc) in the brake-lining manufacturing industry, and 0.14 fibers/cc(0.03-1.36 fibers/cc) in the commutator producing industry. For these industries, the percentage of samples of which asbestos fiber concentrations above the limit of exposure(0.1 fibers/cc) was 97.6% in the asbestos textile industry, 62.3% in the building-materials industry, 53.5% in the brake-lining manufacturing industry, and 34.3% in the commutator producing industry. Asbestos fiber concentration was below the limit of exposure in the gasket producing, petrochemistry, musical instrument producing industries, and the brake-lining exchange operations. Conclusions: Airborne asbestos fiber level in the asbestos textile, brake-lining producing, commutator and building-material producing industries was above the limit of exposure, but in the gasket producing, petrochemistry, musical instrument producing industries and the brake-lining exchange operations were below the limit of exposure.

A Study on Penetration Effect of Penetrating Hardener for Prevention of Scattering of Asbestos Building Materials (석면 건축자재의 비산 방지를 위한 침투성 경화제 침투 효과에 관한 연구)

  • Song, Tae-Hyeob;Park, Ji-Sun;Shin, Hyun-Gyoo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.6 no.4
    • /
    • pp.324-330
    • /
    • 2018
  • In accordance with the amendment of the Industrial Safety and Health Act of 2007, Korea completely prohibited the import, distribution and manufacture of asbestos like Europe and Japan. Accordingly, the current problem of asbestos is the safe maintenance and disposal of asbestos construction material, the disposal of asbestos, and the final disposal of asbestos building materials. In the past, Korea used 100,000 tons of asbestos every year, and the building materials using it exceeded 1 million tons per year. These asbestos building materials continued to be used until 2006, and the Ministry predicted that these materials would continue to be maintained until 2044. When the permeable hardening agent is applied to the asbestos building material installed in the pre-pretreatment step for the harmless treatment of the asbestos waste and the dismantling is carried out, the scattering of the asbestos is suppressed in the disassembling step, detoxification treatment conditions can be improved. Therefore, permeable hardeners should be stably penetrated into asbestos building materials. In this study, it is suggested that pre - pretreatment methods for the harmlessization of waste asbestos building materials with medium density level can be presented. In order to efficiently perform pre - treatment for chemical harmlessness in the future, the mixing ratio of permeable hardener and middle water Optimization is the most important factor.

Asbestos Determination of Some Domestic Building-Materials Using X-ray diffraction (국내 건축자재에 함유된 석면의 함량에 대한 X-선회절분석 연구)

  • Hwang, Jin-Yeon;Lee, Hyo-Min;Oh, Ji-Ho;Park, Gi-Nam
    • Journal of the Mineralogical Society of Korea
    • /
    • v.24 no.2
    • /
    • pp.119-131
    • /
    • 2011
  • The asbestos contents in some representative building materials were analyzed using JIS (Japanese Industrial Standard) X-ray diffraction (XRD) method. The changes in mineral composition during analysis process and problems in JIS method were also examined. XRD analysis of some representative domestic building materials used for roof, wall, ceiling, and floor indicates that slate have the highest asbestos content having 6.87~6.93% of chrysotile. Other building materials analyzed in this study also have 1.35~3.98% of chrysotile contents. The XRD analysis results of asbestos contents in some domestic building materials are presented in this study. This method is very effective for the asbestos content evaluation of building materials according to newly modified asbestos content regulation (Law of Industrial Safety and Health, 2007-26) that limits asbestos content less than 0.1% by Ministry of Employment and Labor. Small amount of tremolite as well as chrysotile were also observed in some samples. With consideration of crystal shape, contents and geological occurrence, it is considered that tremolite is an associated mineral of chrysotile and is not intentionally added. Complemental analyses with optical microscope and SEM/EDS are also necessary because XRD method cannot distinguish asbestiform from non-asbestiform. The XRD method applied in this study is very effective in the asbestos content analysis of building materials, specially building materials showing high asbestos concentration in residues due to the high loss rate with ashing and acid dissolution procedure.

Development of Process Planning Model for Asbsestos Dismantling Work Based on Performance Risk (석면해체 공사의 작업 위험성 기반 공정 계획 모델 개발)

  • Lee, Su-Min;Noh, Jae-Yun;Han, Seung-Woo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.71-72
    • /
    • 2023
  • Asbestos is a durable and heat-resistant building material used in various building materials such as slate, ceiling tex, and spray paint. It has been banned since 2009 after found to be a first-class carcinogen that causes various cancers and asbestos lung disease. Since workers are likely to be exposed to asbestos in the process of dismantling and removal of asbestos-made building materials and facilities, laws and work standards are proposed by the Ministry of Employment and Labor to ensure the safety of asbestos dismantling work. In addition, prior studies on exposure levels and analysis methods have been conducted in this regard mainly for residents. However, the relation between the results of the risk assessment of the process conducted during the asbestos investigation and the work is still ambiguous for the safety of workers. Therefore, this study proposes a process model development methodology that considers work risk based on the results of a survey from asbestos dismantling companies.

  • PDF

A Study on the Factors Affecting Asbestos Exposure Level from Asbestos Abatement in Building Demolition Sites (석면 해체·제거시 공기 중 노출수준과 영향요인)

  • Kim, Ji-Yeong;Lee, Song-Kwon;Lee, Jeong Hee;Lim, Mu Heok;Kang, Sungwook;Phee, Young Gyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.19 no.1
    • /
    • pp.8-15
    • /
    • 2009
  • This study was examined to find out asbestos exposure level the factors which affected the level at asbestos abatement sites. We visited a total of thirteen building demolition sites(3 apartments, 3 schools, 4 stores, and 3 houses) were visited to collect samples and related data from August to November, 2006. The results of this study were as follows 1. The results of an analysis of bulk samples to identify types of asbestos at the asbestos abatement sites showed that the kinds of the asbestos detected were chrysotile by 50.0%, were tremolite by 2.6%, and were the contents of chrysotile by 3 to 20%. 2. The geometric mean concentration of asbestos was 0.007 f/cc(range 0.001-0.34 f/cc) and its geometric standard deviation was 5.83. Of the samples, however, 12 exceeded the Korean Occupational Exposure Limit(0.1f/cc). 3. Of the materials, textile material had the highest concentration with geometric mean of 0.016 f/cc. When asbestos-containing materials were removed using T type tools, the geometric mean concentration of asbestos was 0.061 f/cc. The level by this method was much higher than by other removal methods. In analysis by the type of building, the geometric mean concentration of asbestos in stores was 0.042 f/cc and was higher than in other buildings. 4. The Poisson regression analysis was applied to find out the factors that affect the airborne asbestos concentration. As a result of the analysis, removal using a T type tool was the most important factor affecting the asbestos concentration(p<0.01). In conclusion, the airborne asbestos concentration(geometric mean) in asbestos abatement sites was 0.007 f/cc(0.001~0.34 f/cc), and 12(14.6%) of all samples were over the 0.1 f/cc. These results showed that asbestos abatement workers have been exposed to the high level of airborne asbestos because they have not been keeping asbestos removal rule. In accordance with increases of the number of building demolition sites, the better government regulation on asbestos abatement methods should be made and be performed well at building demolition sites.

Estimation of the Asbestos Handling History of Workers in the Automobile Manufacturing Industry in Korea (자동차 제조 사업장 근로자들의 석면 취급 이력 추정)

  • Choi, Sangjun;Kim, Shinbum;Choi, Youngeun
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.4
    • /
    • pp.423-432
    • /
    • 2017
  • Objectives: This study was conducted to evaluate asbestos handling history of workers at automobile manufacturing plants in Korea. Methods: National regulations on asbestos and Korea Occupational Safety and Health Agency(KOSHA) database on the information of asbestos containing products were reviewed. We investigated asbestos related materials from one automobile manufacturing plant. Material safety data sheets(MSDS) collected in 2010, work environment monitoring results reported from 2000 to 2013, trade union reports and asbestos survey reports were reviewed. We also interviewed workers with long career and did walk-through survey. Results: The Ministry of Labor in Korea has permitted asbestos manufacturing since 1990. In 1997, the use of crocidolite and amosite asbestos were banned. In 2007, the Korean government announced a total ban on the manufacturing, importation and use of all kinds of asbestos, which took full effect in 2009. A total of 174 asbestos products information from KOSHA database was analyzed. Extruded cement panel for building, special brake for crane farm machinery, gasket, joint sheet and thermal insulator were produced until 2007. From automobile manufacturing plant survey, we confirmed that asbestos containing materials(ACM) such as gasket, heating induction materials have been used until 2011. Asbestos containing building materials(ACBM) such as bamlites, slate and ceiling tex were reported at 122 asbestos dismantling projects in 2014. Conclusion: Although the use of all kinds of asbestos were banned from 2009, ACMs and ACBMs installed before 2009 were still found at automobile manufacturing plant until 2011 and 2014 respectively. In particular, asbestos slates should be managed because most of slates had not been removed until 2014.

A Proposal of Hazard/Risk Assessment Criteria and an Asbestos Management Method for Asbestos-containing Building Materials

  • Park, Wha-Me;Kim, Yoon-Shin
    • Journal of Environmental Health Sciences
    • /
    • v.38 no.1
    • /
    • pp.66-72
    • /
    • 2012
  • Objectives: The AHERA method by the US EPA, ASTM E2356-04, and HSG264 by the UK HSE, all of which are hazard/risk assessment methods for asbestos-containing building materials, were reviewed and compared based on 231 homogeneous areas. In addition, the current Act on Asbestos Safety Management (enforcement: April 29, 2012) was reviewed and analyzed. This trial provided fundamental data for improving the current asbestos hazard/risk assessment method. Methods: For the hazard/risk assessment of 77 asbestos-containing public buildings including schools, 231 homogeneous areas were selected, each of which was assessed using AHERA, ASTM E2356-04, and HSG264. Results: The matching rate of the hazard/risk assessment stood at 20.4 percent between AHERA and ASTM, at 71.4 percent between AHERA and HSG264 and at 17.8 percent between ASTM and HSG264. The AHERA method includes a seven-category rating scale. There were three categories, two of which have three subcategories. ASTM provides two decision-making charts consisting of ten rating scales for current condition estimation and for potential for disturbance estimation. In addition, the HSG264 method has a total of 20 scores with four items, and then provides four grades. This HSG264 method cannot clearly separate current condition and potential for disturbance. Conclusions: In the Korean Act on Asbestos Safety Management, the hazard/risk assessment method for asbestos-containing building materials should consider balance between current condition estimation and the potential for disturbance estimation.

Investigation and Risk Assessment of Asbestos-Containing Materials used in Buildings (건축물에 사용된 석면함유물질(ACMs)의 조사 및 위해성 평가)

  • Kim, Hong-Kwan;Chon, Young Woo;Roh, Young Man;Hong, Seung-Han;Kim, Chi-Nyon;Lee, Ik-Mo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.28 no.1
    • /
    • pp.35-42
    • /
    • 2018
  • Objectives: The objectives of this study are to research the usage characteristics of asbestos-containing building materials and to conduct exposure risk assessment by applying no. 2016-230 "Methods of Risk Assessment of Asbestos-Containing Buildings" from the Ministry of Environment. Methods: One hundred buildings located in the Seoul and Gyeonggi-Incheon area were chosen, with 29 in Seoul, 20 in Incheon, and 51 in Gyeonggi-do Province. The year of construction was divided between three buildings in the 1970s, 11 buildings in the 1980s, 42 buildings in the 1990s, and 44 buildings in the 2000s. The bulk samples were analyzed by using a polarizing microscope after a pre-process using a stereomicroscope in a hood with an HEPA filter. This study defined ACMs(asbestos-containing materials) as asbestos when the content percentage was over 1% in the analysis result. Methods and standards of risk assessment of asbestos-containing building materials were conducted by refering to no. 2016-230 "Method of Risk Assessment of Asbestos-Containing Buildings" from the Ministry of Environment. The risk of exposure to ACMs was rated by a score based on three categories(high, middle, low risk of asbestos exposure). Results: In this study, 30 of the 100 buildings and 36 of the 416 bulk samples(8.6%) were found to have had asbestos. Asbestos was detected at a high rate, in 18 out of 42, in buildings constructed in the 1990s and at the lowest rate(7 out of 44) for buildings constructed in the 2000s. As a result of the evaluation according to no. 2016-230 "Method of Risk Assessment of Asbestos-Containing Buildings" of the Ministry of Environment, the risk assessment level of two asbestos-containing building materials was found to be "Medium", and 28 buildings materials were found to be at the "Low" level. Conclusion: As asbestos is regulated by the government, it is required to conduct active management and implemention by introducing methods of risk assessment of asbestos exposure that are supported by data from various situations. In the case of buildings owned by individuals, building owners should be aware of the risk of exposure to asbestos.