• Title/Summary/Keyword: Artificial tooth

Search Result 178, Processing Time 0.028 seconds

Comparative analysis of strain according to the deposition of a constant temperature water bath of a denture-base artificial tooth produced using three-dimensional printing ultraviolet-curing resin (3D 프린팅용 광경화 수지를 사용하여 제작한 의치상용 인공치아의 항온수조 침적에 따른 변형률 비교 분석)

  • Kim, Dong-Yeon;Lee, Gwang-Young;Kim, Jae-Hong;Yang, Cheon-Seung
    • Journal of Technologic Dentistry
    • /
    • v.42 no.3
    • /
    • pp.202-207
    • /
    • 2020
  • Purpose: This study is a comparative analysis of the strain according to deposition in a constant temperature water bath after manufacturing ultraviolet (UV)-cured artificial teeth. Methods: As a control group, 10 ready-made artificial teeth were selected as the first molar on the right side of the maxilla (RT group). Silicone was used as a duplicate of the artificial denture teeth. Experimental teeth were prepared in two groups using the prepared silicone mold. In the first experimental group, the UV-cured resin was injected into the negative silicone, followed by irradiation with a UV-curing machine for 5 minutes (5M group). In the second experimental group, the UV-cured resin was injected into the negative silicone, and then irradiated for 30 minutes using a UV-curing machine (30M group). The one-way ANOVA was performed, and post-test was analyzed by Tukey. Results: When immersed in a water bath for 15 days, it was found to be -0.3% in the RT group, -0.6% in the 5M group, and -0.7% in the 30M group. The results revealed -0.2% in the RT group, 0.2% in the 5M group, and -0.2% in the 30M group when they were in the bath for 30 days. Conclusion: In the water bath, the swelling was greater when deposited for 1 to 15 days, but was less when deposited for 15 to 30 days.

Change in surface of primary tooth using different type of toothpaste (치약 종류에 따른 유치의 표면 변화)

  • Choi, Jung-Ok;Nam, Seoul-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.14 no.2
    • /
    • pp.281-286
    • /
    • 2014
  • Objectives : The aim of this study is to evaluate the surface changes of enamel specimen, tooth structure by toothpastes in child and adult. Methods : Experimental teeth were collected from extracted human primary teeth. 120 enamel specimens were prepared by cutting the teeth into $2{\times}3{\times}2mm$ blocks using diamond saw and the specimens were assigned to 3 groups. Group 1 was used as control with no treatment. Group 2 was treated with child toothpaste and Group 3 was treated with adult toothpaste on primary enamel surface for 3 minutes daily over 4 weeks. The specimens were immersed into individual container having artificial saliva and the artificial saliva was changed every day. The electron probe micro analyzer(EPMA) provided weight percent(wt%) of calcium(Ca) and phosphorous(P) on enamel surface. The morphology was analyzed by scanning electron microscopy(SEM). Data were analyzed by one-way analysis of variance(ANOVA) and Tukey's test post-hoc test using SPSS(Version 20, SPSS Inc., Chicago, USA). Level of significance was set at 0.05. Results : The surface changes of the primary teeth revealed a significant difference during 4 weeks. Calcium(Ca) and phosphorous(P) levels were found the weight percent difference and a rough enamel surface was seen on SEM after adult toothpaste application. Conclusions : The changes in Ca and P and the morphological surface were affected by the primary tooth treated with adult toothpaste. Enamel surface showed significant differences during 4 weeks.

Shear bond strength of a layered zirconia and porcelain according to treatment of zirconia liner (치과용 지르코니아 이장재 처리에 따른 지르코니아와 도재의 전단결합강도 비교)

  • Seo, Jeong Il;Park, Won Uk;Kim, Yang Geun
    • Journal of Technologic Dentistry
    • /
    • v.39 no.1
    • /
    • pp.43-52
    • /
    • 2017
  • Purpose: Physical and chemical properties of gold is most suitable to be restored of teeth to its original state. Recently zirconia was used instead of gold because of esthetical and intimacy of human body. Because of high strength and high abrasion resistance of zirconia, all zirconia artificial tooth lead to wear the original tooth of opposite site. To preserve this original tooth, zirconia artificial tooth covered with dental ceramic glass was used. When joining the zirconia core and dental ceramic glass, difference of their thermal expansion coefficient and wetting ability is generated the residual stress at interface lead to crack. In order to solve this problem, intermediate layer what is called zir-liner was imported to decrease the residual stress and increase the bonding strength. Methods: In this study, to identify the optimum conditions for manufacturing process, various methods to rough the surface of zirconia core were adopted, and vary the thickness of interlayer, and analyzed bond strength. Results: Bond strength of sanding specimens group showed higher than that of non-sanding specimens group, and once applied intermediate layer with sanding specimens showed highest bond strength with 28 MPa. SEM photomicrographs of zirconia cores fired at $1500^{\circ}C$ showed parallel straight lines in sanding and pockmarked surface in blasting surfaces as abrasion traces. Observation of the destruction section after shear test by SEM were carried out. Liner applied non-sanding group and non-liner applied sanding group all showed interfacial crack. Sandblasting group with non-liner showed remained dental ceramic glass on the surface of zirconia. Sandblasting group with once applied liner showed partially remained liner and dental ceramic glass on the surface of zirconia. XRD analysis revealed that sandblasting group showed higher monoclinic peaks than other specimens group and this result was due to the high collision energy for stress induced phase transformation. Conclusions: A study on the improvement of bonding strength between zirconia and dental ceramic glass steadily carried out for the future to practical use.

SHADE ANALYSIS OF ARTIFICIAL TEETH USING SHADE $SCAN^{TM}$ SYSTEM (ShadeScan$^{TM}$ System을 이용한 인공치의 색조분석)

  • Sung, Chai-Ryun;Cho, In-Ho;Lee, Jong-Hyuk
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.4
    • /
    • pp.443-457
    • /
    • 2004
  • Purpose: The purpose of this study was to analyze and estimate whether each company may produce the color of artificial teeth as it stands, in the standard of vita classical shade guide using ShadeScan$^{TM}$ System. Material and methods: we chose the products of 6 companies -EFUCERA, IVOCLAR, ENDURA, TRUBYTE, DURADENT, and DURACROSS- estimated the shade value of each fixed point(cervical, body, and incisal area) of artificial tooth, and verified the equality among the samples from the same company. Results: First, the variation appeared significant at cervical and incisal area. It means that there were significant differences between cervical and incisal area although the most similar artificial teeth to the patients’natural teeth were provided. Second, the results in the body area showed that the variation between artificial and natural teeth was finite(p<0.05) in that area. Conclusion: it shows that the reproduction of colors of artificial teeth might be successful regarding the body is the most important part for a determination of the color of artificial teeth. However, more complements are necessary for the better reproduction of the color of artificial teeth between cervical and incisal area.

Evaluation of the Potential of Commercial Vitamin Drinks to Induce Tooth Erosion

  • Kim, Han-Na;Yoon, Tae-Lim;Min, Ji-Hyun
    • Journal of dental hygiene science
    • /
    • v.19 no.3
    • /
    • pp.154-161
    • /
    • 2019
  • Background: The market for vitamin drinks is expanding both in Korea and worldwide. However, it was difficult to find studies regarding the possibility of tooth erosion induction due to vitamin drinks. The purpose of the present in vitro study was to evaluate the effect of tooth erosion caused by a few commercial vitamin beverages on bovine teeth enamel in terms of erosion depth and fluorescence loss. Methods: Three experimental groups (vitamin drinks), a positive control group (Coca-Cola), and a negative control group (mineral water) were established. Each group consisted of 5 specimens obtained from sound bovine teeth. The pH and titratable acidity of beverages were measured. Specimens were immersed in the beverages and artificial saliva for 6 and 18 hours, respectively. This cycle was repeated for 5 days. The depth of the tooth loss caused by tooth erosion (erosion depth) and maximum loss of fluorescence (Max ${\Delta}F$) were measured using the microscope and quantified light-induced fluorescence-digital, respectively. For the statistical analysis, the Kruskal-Wallis test and ANOVA were used to compare the erosion depth and Max ${\Delta}F$ of the enamel surfaces. In addition, Spearman correlations were estimated. Results: The pH of the three vitamin beverages ranged from 2.65 to 3.01, which is similar to that of the positive control group. All beverages, except mineral water, had sugar and acidic ingredients. Vitamin drinks and the positive control, Coca-Cola, caused tooth erosion lesions, and showed significant differences in erosion depth compared to mineral water (p<0.05). The vitamin beverages with low pH were associated with high erosion depth and Max ${\Delta}F$. Conclusion: Vitamin drinks have the potential to cause tooth erosion.

Preparation of Dense Polycrystalline Hydroxyapatite Ceramics for the Application of Tooth Implants (인공치아용 수산화 인산칼슘 요업체의 제조)

  • 하조웅;정형진
    • Journal of the Korean Ceramic Society
    • /
    • v.20 no.1
    • /
    • pp.55-62
    • /
    • 1983
  • the preliminary work on the prepartion of fine hydroxyapatite powder and the synthesis of dense hydroxyapatite ceramic from the powder were investigated for the development of artificial bone and tooth materials for implants. The effects of the process variables such as compositions of the raw materials the initial pH of the solutions and sintering temperature on the physical properties were investigated in order to determine the optimum conditions for the fabrication of tooth implant material. As the initial pH of the solutions was increased in the range of 10-11.6 the initial particle size of precipitates was decreased thus the sinterability of precipitates was improved. It was found that the composition of calcium rich of 1.75 in Ca/P mole ratio exhibited better sinterability and mechanical strength of the apatite ceramics for example the highest value of Vicker's hardness obtained from the compositions of 1.75 in Ca/P mole ratio was 764±30 Kg/mm2 compared to the maximum value of 600 kg/mm2 obtained from the compositions of 1.67 in Ca/P mole ratio.

  • PDF

COMPARATIVE STUDY OF THE REMINERALIZATION EFFECTS USING CPP-ACP AND FLUORIDE ON THE ARTIFICIAL ENAMEL LESION (CPP-ACP 함유 크림과 불소가 초기 인공우식 법랑질에 미치는 재광화 효과에 대한 비교 연구)

  • Kim, Ki-Baek;Choi, Nam-Ki;Kim, Seon-Mi;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.36 no.1
    • /
    • pp.38-45
    • /
    • 2009
  • The aim of this study was to examine efficacy of the commercially available 10% CPP-ACP cream (Tooth mousse, GC Co., Japan) and/or 0.05% NaF solution on the remineralization of artifical caries-like lesion in the bovine teeth enamel. Sixty bovine teeth were embedded in orthodontic resin and flattened. The enamel surface in 3 mm diameter was exposed with nail varnish. Specimens were stored in demineralizing solution and divided 5 groups; Group 1 (No treatment), 2 (0.05% NaF solution 1 min), 3 (Tooth mousse 3 min), 4 (After 0.05% NaF solution, Tooth mousse treatment), and 5 (After Tooth mousse treatment, soaking in 0.05% NaF solution during 1 min). After treatment by groups, all specimens was stored in artificial saliva for 30 min. After the process described as above was performed during 10 days without pH cycling, surface hardness (Vickers Hardness Number, VHN) was tested and analyzed by paired t-test and one-way ANOVA test with SPSS 14.0. In intragroup comparison between surface hardness of pre and post-treatment, group 3, 4, 5 showed statistically significant increase (P < 0.05). In intergroup comparison among surface hardness increase of all groups, difference of group 5 between pre and post-treatment ($15.80{\pm}12.21$) was the highest, and followed by group 4 ($14.27{\pm}11.73$), 3 ($4.05{\pm}5.18$), 2 ($1.15{\pm}6.83$), 1 ($0.78{\pm}6.21$). Tooth mousse can be a good alternative agent for the fluoride, and the combination use with fluoride might have the additional anticariogenic effect.

  • PDF

Fabrication of surveyed crown and repairing the artificial teeth for existing removable partial denture using digital technology: a case report (디지털 방식을 이용한 기존 국소의치 맞춤 보철 제작과 심미적인 인공치 수리 증례)

  • Ina Kim;Eunji Oh;Sang-Won Park;Hyun-Pil Lim;Kwi-dug Yun;Chan Park
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.40 no.2
    • /
    • pp.82-90
    • /
    • 2024
  • It often happens that a removable partial denture needs to be repaired due to tissue changes in the remaining alveolar ridge, fracture of the denture, or fracture of the abutment tooth. There are several advantages to retrofitting a customized surveyed crown under the existing RPD. Retrofitting a crown to the RPD decreases the economic burden to the patient and avoids the need for several appointments to fabricate a new RPD. It is difficult for artificial teeth used to repair dentures due to fractured natural teeth to have a shape similar to that of natural teeth, and to repair aesthetic artificial teeth, it is necessary to manufacture customized artificial teeth similar to the shape of each patient's teeth. Recently, CAD/CAM technology has been used to fabricate customized prosthetics on existing RPD to achieve high retention and fitness accuracy, and by manufacturing customized artificial teeth, more aesthetic and harmonious artificial tooth repair is possible. This is a case in which a denture was repaired using a digital method to fabricate a customized prosthesis on an existing partial denture and customized artificial teeth that mirrored the adjacent dentition, saving time and cost, simplifying the process, and achieving aesthetically and functionally satisfactory results.

Blue-tooth based blood sugar control application

  • Kelly, Raymond
    • Korean Journal of Artificial Intelligence
    • /
    • v.3 no.1
    • /
    • pp.4-6
    • /
    • 2015
  • These days, citizens have made change of food life to take Western style food and to suffer from diabetes because of excessive nutrition taking, less exercise, stress and other environmental factors. They may suffer from diabetes because of genetic defect, surgery of pancreas, disinfection and medicine and others. One of ten Koreans may have symptom of diabetes to be popular. The diabetes that is a kind of metabolic disease has high blood sugar at disorder of hyper insulinism and/or defect of insulin action. Long time high blood sugar may produce chronic disease of kidney, eyes, nerve, heart and blood vessel and others. The purpose of health care of diabetes patient was to reach target blood sugar by diet, physical exercise and medicine and to prevent and delay complication. Diabetes patient shall control blood sugar to keep healthy. The blood sugar control requires time and effort, and all of the patients are difficult to make effort and to spend time. You can control blood sugar by the application. The application allows patients to control blood sugar and to save time and efforts and to make small sized input and automation of remaining area. The service was limited to blood sugar graph, and user carries smart phone to conduct test and to have difficulty. Further study needs to solve the problems and to investigate blood sugar testing not carrying smart phone and to make application of easy control of blood sugar.

A Study on the Performance of Dynamic Restraint Manipulator for Drilling Alveolar Bone in Mandible (하악골의 치조골 골삭제를 위한 동적 제약 기구부의 성능에 관한 연구)

  • Kim, Gwang-Ho;Lee, Dong-Woon;Jeong, Sang-Hwa
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.12
    • /
    • pp.105-112
    • /
    • 2020
  • The increase in the edentulous jaw which occurs in the aged population has led to personal dental health concerns. In the case of dental implant surgery, the duration of a patient's recovery depends on the surgical plan and their physicical ability. A device may be required to assist a physician in controlling vibration reduction of free-hand drilling and prescribing a good treatment plan that is suitable for the patient's condition. In this work, an artificial tooth-root implant assistant manipulator was studied. The structure and the vibration analysis of the dynamic restraint manipulator that is for drilling the alveolar bone in the mandible bone were performed, and the structural stability was analyzed. Further, a virtual prototype of an artificial tooth-root implant assisted manipulator was fabricated and tested. Hence, the state of the Remote Center of Motion (RCM) point and the driving state of the manipulator were confirmed. Furthermore, the drilling experiments were performed by using materials similar to a human jawbone in order to evaluate the performance of the drilling process that is operated using the assistant manipulator.