• Title/Summary/Keyword: Artificial contamination test

Search Result 23, Processing Time 0.027 seconds

Effects of Artificial Saliva Contamination on the Bond Strength of Three Dentin Adhesives to Dentin of Primary Teeth (인공타액오염이 유치 상아질에서 3종 상아질 접착제의 결합 강도에 미치는 영향)

  • Bae, Youngeun;Kim, Shin;Jeong, Teasung;Kim, Jiyeon
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.44 no.1
    • /
    • pp.72-81
    • /
    • 2017
  • The aim of this study was to evaluate the effectiveness of artificial saliva contamination and decontamination procedures at different stages of a bonding procedure on the microtensile bond strength (MTBS) of two one-step self-etch adhesives and a two-step total-etch adhesive to dentin of primary teeth. Forty-two extracted sound primary molars were randomly divided into three groups depending on three adhesives, Scotchbond Universal Adhesive (SBU), All-Bond Universal (ABU) and Prime & Bond NT (PNT). For each adhesive, the teeth were allocated into seven groups. Except for control group, group 1, the groups were contaminated with artificial saliva at three different stages: the groups 2 and 3 - before adhesive application; the groups 4 and 5 - before adhesive polymerization; the groups 6 and 7 - after adhesive polymerization. Decontaminating procedures were rinsing, air-drying (group 2, 4, 6) and air-drying (group 3, 5, 7). The specimens were restored with composite resin (Filtek, Z350) and microtensile bond strength was measured. The data was analyzed with one-way ANOVA and Tukey HSD test (p < 0.05). In the control group, using PNT resulted in significantly higher bond strength than when ABU and SBU were used (p < 0.001). For three adhesives, the groups 2, 4 and 6 had greater bond strength than the groups 3, 5 and 7. Also, when the artificial saliva was contaminated before adhesive polymerization (group 4, 5), it showed a significantly lower bond strength. Generally the two-step total-etch adhesive generated a higher bond strength than the one-step self-etch adhesive. Artificial saliva contamination before adhesive polymerization led to a drastic decrease in bond strength, and rinsing with water followed by air-drying could not recover the bond strength.

Performance testing of a FastScan whole body counter using an artificial neural network

  • Cho, Moonhyung;Weon, Yuho;Jung, Taekmin
    • Nuclear Engineering and Technology
    • /
    • v.54 no.8
    • /
    • pp.3043-3050
    • /
    • 2022
  • In Korea, all nuclear power plants (NPPs) participate in annual performance tests including in vivo measurements using the FastScan, a stand type whole body counter (WBC), manufactured by Canberra. In 2018, all Korean NPPs satisfied the testing criterion, the root mean square error (RMSE) ≤ 0.25, for the whole body configuration, but three NPPs which participated in an additional lung configuration test in the fission and activation product category did not meet the criterion. Due to the low resolution of the FastScan NaI(Tl) detectors, the conventional peak analysis (PA) method of the FastScan did not show sufficient performance to meet the criterion in the presence of interfering radioisotopes (RIs), 134Cs and 137Cs. In this study, we developed an artificial neural network (ANN) to improve the performance of the FastScan in the lung configuration. All of the RMSE values derived by the ANN satisfied the criterion, even though the photopeaks of 134Cs and 137Cs interfered with those of the analytes or the analyte photopeaks were located in a low-energy region below 300 keV. Since the ANN performed better than the PA method, it would be expected to be a promising approach to improve the accuracy and precision of in vivo FastScan measurement for the lung configuration.

Determination of Phthalates Compounds in the Ambient Atmosphere (II) - Evaluation of Experimental Artifacts and Sample Clean-up Procedures - (환경대기 중 프탈레이트 화합물의 농도 측정 (II) - 실험재료 전처리 및 시료정제과정 평가 -)

  • Park, Young-Hwa;Hwang, Yoon-Jung;Seo, Young-Kyo;Baek, Sung-Ok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.5
    • /
    • pp.455-460
    • /
    • 2010
  • This study was carried out to find out any inherent problems occurring in the sampling and analytical procedures, and to suggest the relevant solutions to the problems. In addition, an optimal condition of clean-up process was developed, which was based on a method using silica glass column. As a result of experiments to test any artificial contamination of blank samples such as glassware and collection media, artifacts of DBP and DEHP appeared to be detected in various kinds of laboratory tools and apparatuses used in the sampling and analytical works. Therefore, it is necessary to investigate a degree of contamination before laboratory works by conducting a prior check any possible contaminations in all experimental tools and apparatus. It is also necessary to devise a method to avoid a tool, if possible, or to use a substitute of phthalate free. If the use of any plastic tool to cause contamination is inevitable, it should be properly corrected with a blank level, as is equally treated as the sample. The clean-up process demonstrated in this study can give us a significant benefit in terms of the quantity and quality of a target compound by GC/MS analysis.

MARGINAL MICROLEAKAGE AND SHEAR BOND STRENGTH OF COMPOSITE RESIN ACCORDING TO TREATMENT METHODS OF ARTIFICIAL SALIVA-CONTAMINATED SURFACE AFTER PRIMING (접착강화제 도포후 인공타액에 오염된 표면의 처리방법에 따른 복합레진의 번연누출과 전단결합강도)

  • Cho, Young-Gon;Ko, Kee-Jong;Lee, Suk-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.25 no.1
    • /
    • pp.46-55
    • /
    • 2000
  • During bonding procedure of composite resin, the prepared cavity can be contaminated by saliva. In this study, marginal microleakage and shear bond strength of a composite resin to primed enamel and dentin treated with artificial saliva(Taliva$^{(R)}$) were evaluated. For the marginal microleakage test, Class V cavities were prepared in the buccal surfaces of fifty molars. The samples were randomly assigned into 5 groups with 10 samples in each group. Control group was applied with a bonding system (Scotchbond$^{TM}$ Multi-Purpose plus) according to manufacture's directions without saliva contamination. Experimental groups were divided into 4 groups and contaminated with artificial saliva for 30 seconds after priming: Experimental 1 group ; artificial saliva was dried with compressed air only, Experimental 2 group ; artificial saliva was rinsed and dried. Experimental 3 group ; cavities were etched with 35% phosphoric acid for 15 seconds after rinsing and drying artificial saliva. Experimental 4 group ; cavities were etched with 35% phosphoric acid for 15 seconds and primer was reapplied after rinsing and drying artificial saliva. All the cavities were applied a bonding agent and filled with a composite resin (Z-100$^{TM}$). Specimens were immersed in 0.5% basic fuschin dye for 24 hours and embedded in transparent acrylic resin and sectioned buccolingually with diamond wheel saw. Four sections were obtained from one specimen. Degree of marginal leakage was scored under stereomicroscope and their scores were averaged from four sections. The data were analyzed by Kruscal-Wallis test and Fisher's LSD. For the shear bond strength test, the buccal or occlusal surfaces of one hundred molar teeth were ground to expose enamel(n=50) or dentin(n=50) using diamond wheel saw and its surface was smoothed with Lapping and Polishing Machine(South Bay Technology Co., U.S.A.). Samples were divided into 5 groups. Treatment of saliva-contaminated enamel and dentin surfaces was same as the marginal microleakage test and composite resin was bonded via a gelatin capsule. All specimens were stored in distilled water for 48 hours. The shear bond strengths were measured by universal testing machine (AGS-1000 4D, Shimaduzu Co., Japan) with a crosshead speed of 5 mm/minute. Failure mode of fracture sites was examined under stereomicroscope. The data were analyzed by ANOVA and Tukey's studentized range test. The results of this study were as follows : 1. Enamel marginal microleakage showed no significant difference among groups. 2. Dentinal marginal microleakages of control, experimental 2 and 4 groups were lower than those of experimental 1 and 3 groups (p<0.05). 3. The shear bond strength to enamel was the highest value in control group (20.03${\pm}$4.47MPa) and the lowest value in experimental 1 group (13.28${\pm}$6.52MPa). There were significant differences between experimental 1 group and other groups (p<0.05). 4. The shear bond strength to dentin was higher in control group (17.87${\pm}$4.02MPa) and experimental 4 group (16.38${\pm}$3.23MPa) than in other groups, its value was low in experimental 1 group (3.95${\pm}$2.51 MPa) and experimental 2 group (6.72${\pm}$2.26MPa)(p<0.05). 5. Failure mode of fractured site on the enamel showed mostly adhesive failures in experimental 1 and 3 groups. 6. Failure mode of fractured site on the dentin did not show adhesive failures in control group, but showed mostly adhesive failure in experimental groups. As a summary of above results, if the primed tooth surface was contaminated with artificial saliva, primer should be reapplied after re-etching it.

  • PDF

Study on Distribution of Microbes in Waterscape Facilities in Gyeonggi-do (경기도내 물놀이형 수경시설 중 미생물 분포 조사 연구)

  • Jeong, Ah-Yong;Park, Myoung-Ki;Kim, Yun-Sung;Lee, Chang-Hee;Lee, Jung-Hee;Lee, Hye-Yeoun;Kim, Young-Suk
    • Journal of Environmental Health Sciences
    • /
    • v.46 no.6
    • /
    • pp.710-718
    • /
    • 2020
  • Objectives: We analyzed water in waterscape facilities to investigate contamination levels of water-borne pathogens and four test items (pH, turbidity, residual chlorine, and Escherichia coli) at facilities including play fountains, splash parks, and artificial streams from June to October in Suwon City and in the whole of Gyeonggi-do. Methods: A total of 62 waterscape facility samples were collected from 36 sites and tested for pathogenic Escherichia coli and water-borne viruses that cause hand-foot-and-mouth disease, eye disease, and acute enteritis. Results: None of the water-borne pathogens were detected in waterscape facility samples collected from across Gyeonggi-do that were for pre-inspection for facility management. However, the results of samples from Suwon collected in hot weather and during the school vacation period showed five total inconsistencies in turbidity (four cases) and Escherichia coli (one case). Three out of the four inconsistent samples in turbidity were from the same facility which operated a sand filtration system due to its locational factors close to mountains. Conclusion: We suggest that the waterscape facilities in Gyeonggi-do are managed properly in the respect of microbial contamination and water quality.

Changes in the Characteristics of Textile Products according to the Storage Environmental Condition for Sustainable Care (섬유제품의 지속가능한 관리를 위한 보관환경에 따른 특성변화 연구)

  • Kim, Jeong-Hwa;Lee, Sun-young;Lee, Jung-Soon
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.46 no.3
    • /
    • pp.390-406
    • /
    • 2022
  • This study aims to establish the optimal environmental conditions for storing textile products. Four textile products (cotton, wool, nylon, cotton/polyurethane) were used to produce experimental fabrics according to artificial contamination and washing conditions. Each fabric was subjected to three environmental conditions (A: 20-25℃/20% RH, B: 20-25℃/50% RH, C: 30-35℃/65% RH) for 4-12 weeks. Changes in textile characteristics include tensile strength, wrinkle recovery rate, and odor intensity. Results show that the change in tensile strength for the four test fabrics slightly decreased with a storage time of 4 to 12 weeks. The wrinkle recovery rate of the fabrics was the lowest under the C condition. UV exposure causes a substantial decrease in the tensile strength of the textiles. The change in odor characteristics was the highest for the odor intensity in the C condition. For storing textile products for sustainable management, it is desirable to maintain a temperature of 20 to 25℃ with a relative humidity of 50% RH or less and to provide ventilation in an enclosed storage space that can also block UV rays.

Radioactivity Originating from the Chinese Nuclear Test Explosions Observed in Seoul District in 1964-1967 (中共 核實驗에 의한 서울地區의 放射線 汚染度 評價)

  • Kang, Man-Sik
    • The Korean Journal of Zoology
    • /
    • v.11 no.3
    • /
    • pp.85-91
    • /
    • 1968
  • Artificial and natural radioactivity in airborne, rain-out and fallout dusts in Seoul district in the period of 1963-1967 were studied by measuring gross-activity and by analyzing nuclides by means of $\\gamma$-spectrometry. Short-lived radium and thorium decay products give rise to most of the airborne activity unless the fission product concentration is extremely high and it is likely to be said activity remaining after a few days is attributable to fission products. Of seven Chinese nuclear explosions performed at Lop Nor, Sinkiang Province, two exhibited the activity of extremely high concentration of fission product and reached Seoul district around 30 hours after the explosion. The activity was followed by a sudden decrease in less than a week, in contrast to the long-lasted activity of low concentration originating from the huge tests performed by the United States and the USSR in 1956-1962. The radioactive environmental contamination in Seoul district, due to the Chiness nuclear test explosions, largely depends on the height above the earth at which the nuclear explosion is performed and the type of nuclear device as well as the weather system at the time and immediately after the explosion, especially the jet stream in middle latitude in the upper troposphere.

  • PDF

The Characteristics of Heavy Metal(Zn, Pb) Accumulations in Paridae Nesting Material (박새과 조류의 둥지 재료 내 중금속(Zn, Pb) 축적특성 연구)

  • Kyeong-Tae Kim;Hyun-Jung Lee;Whee-Moon Kim;Won-Kyong Song
    • Korean Journal of Environment and Ecology
    • /
    • v.36 no.6
    • /
    • pp.566-574
    • /
    • 2022
  • Heavy metals are one of the dangerous pollutants that threaten urban biodiversity due to their accumulation over a long period without being decomposed in vivo. Accordingly, there is a need for biological monitoring to compare accumulation concentrations in living organisms according to the degree of heavy metal exposure to evaluate heavy metal contamination in the air in urban areas. This study aims to examine the possibility of using nesting materials as heavy metal monitoring samples and determine the effects of heavy metals on Paridae. We installed 54 artificial nest boxes in the research areas that included campus green spaces (14), urban forests (11), and urban parks (29) on a university campus in Cheonan City, Chungcheongnam Province. The birds' use rate of artificial nest boxes was 11/14 (78.57%) in campus green spaces, 8/11 (72.72%) in urban forests, and 6/29 (20.68%) in urban parks. Moss materials were collected from collected nests, and the heavy metal accumulation characteristics of each type of urban green space and the effects of heavy metals on the success of fledging of Paridae were compared through heavy metal analysis. The analysis showed that the average concentrations of zinc and lead were 228.08±209.62 ㎍/dry g and 17.67 ± 6.72 ㎍/dry g, respectively. There was no significant difference in zinc concentration for each type of urban green space (Kruskal-Wallis test, p-value=0.28), but lead concentration showed a significant difference (Kruskal-Wallis test, p<0.05*). Of the 21 Paridae, nests analyzed for heavy metals, fledging of birds was observed in 11 nests (52.38%). Fledging of birds observed in each urban green space type was 7 campus green spaces (77.78%), 6 in urban forests (85.71%), and 1 in urban park (20%), mainly in urban forests and green spaces on campus. Heavy metal concentrations were compared to check the effect of heavy metal accumulation on the successful fledging of Paridae, but there was no statistically significant difference (Zn: W=44, p-value=0.74, Pb: t=0.64676, df =7.2422, p-value=0.54). This study is a basic study using the nesting materials of Paridae as heavy metal monitoring samples, and it is determined that it can be used as basic data for non-invasive biological monitoring.

Effects of Storage Time on Bacteria Concentration and Sperm Parameters in Boar Semen (돼지 액상정액 보존 일수에 따른 정액내 세균과 정자 기능의 변화)

  • Chung, Ki-Hwa;Kim, In-Cheol
    • Reproductive and Developmental Biology
    • /
    • v.36 no.3
    • /
    • pp.163-166
    • /
    • 2012
  • This study was conducted to determine the relationship between elapsed time after semen preservation on the changes of bacteria and semen quality. Semen was diluted with BTS(Beltsville Thawing Solution) extender without antibiotic for 7 days and sperm parameter and fertility were measured. Sperm motility was measured by CASA and total bacteria number was counted after 22~24 hr incubation from counting agar plate in which sperm dilute to $10{\sim}10^6$ in 0.9% saline solution and inoculate to agar. Acrosomal integrity was measured by Chlortetracycline (CTC) staining. CTC patterns were uniform fluorescence over the whole head (pattern F), characteristic of incapacitated acrosome-intact spermatozoa; fluorescence-free band in the post-acrosomal region (pattern B), characteristic of capacitated acrosome-intact spermatozoa; and almost no fluorescence over the whole head except for a thin band in the equatorial segment (pattern AR), characteristic of acrosome reacted spermatozoa. Total number of bacteria was significantly increased (p<0.0001) 3 days after preservation. Sperm motility, viability, and morphological abnormality on elapsed time after preservation were lower from 5 ($77.24{\pm}6.47$, p<0.001) and 7 days ($77.24{\pm}6.47$, p<0.001) after preservation compared to 1 ($15.71{\pm}7.18$) and 3 days($18.39{\pm}7.22$) after preservation, respectively. Sperm viability was significantly lower ($53.25{\pm}35.03$, p<0.0001) at 7 days after preservation. Morphological abnormality of sperm was lower (p<0.001) at 1 ($15.71{\pm}7.18$) and 3 ($18.39{\pm}7.22$) days compared to 5 ($21.84{\pm}7.91$) and 7 ($22.59{\pm}9.93$) days after preservation. Acrosomal integrity and capacitation rate (pattern F) were significantly lower (p<0.001) from 5 days after preservation. Based on the data we obtained from this study suggested that semen preserved more than 5 days without antibiotic would not recommend use for artificial insemination.

Evaluation of Proposed Diagnostic System for Detection of Pan-enterovirus Using Reverse Transcription Nested PCR from Water Environment

  • Siwon Lee;Kyung Seon Bae;Jin-Ho Kim;Ji-Hyun Park;Ji Hye Kim;Ji-Yeon Park;Kyung-Jin Lee;Chae-Rin Jeon;Jeong-Ki Yoon;Soo-Hyung Lee;Eung-Roh Park
    • Biomedical Science Letters
    • /
    • v.29 no.2
    • /
    • pp.81-87
    • /
    • 2023
  • Pan-Enterovirus (Pan-EV) infects millions of children and infants worldwide every year. As severe infections have recently been reported, the need for monitoring has consequently intensified. Pan-EV is a categorical name for waterborne enteroviruses belonging to the Picornaviridae family, and includes a wide range of pathogens including Coxsackievirus (CoxV), Echovirus (EcoV) and Enterovirus (EV). In this study, we proposed an optimal RT-nested PCR method for diagnosis of various types of Pan-EV in an aquatic environment and developed a positive control. Considering detection sensitivity, specific reaction, and final identification, one condition capable of amplifying 478 bp among the four candidates in the 1st round PCR (RT-PCR) and one condition in the 2nd round PCR (nested PCR) were selected. Through the detection of nucleic acids extracted from 123 groundwater samples and the detection sensitivity test based on artificial spiking in the sample, the methods are optimal for non-disinfected water samples such as groundwater. We developed a positive control for Pan-EV detection that can be amplified to different sizes under the two conditions. Accuracy could be further improved by testing for contamination from the control group. The method proposed in this study and the positive control developed are expected to be used in monitoring Pan-EV in aquatic environments including groundwater through future research using more samples.