• Title/Summary/Keyword: Artificial Organs

Search Result 85, Processing Time 0.02 seconds

Spectrometry Analysis of Fumes of Mixed Nuclear Fuel (U0.8Pu0.2)O2 Samples Heated up to 2,000℃ and Evaluation of Accidental Irradiation of Living Organisms by Plutonium as the Most Radiotoxic Fission Product of Mixed Nuclear Fuel

  • Kim, Dmitriy;Zhumagulova, Roza;Tazhigulova, Bibinur;Zharaspayeva, Gulzhanar;Azhiyeva, Galiya
    • Nuclear Engineering and Technology
    • /
    • v.48 no.1
    • /
    • pp.274-284
    • /
    • 2016
  • Purpose: The purpose of this work is to describe the spectrometric analysis of gaseous cloud formation over reactor mixed uranium-and-plutonium (UP) fuel $(U_{0.8}Pu_{0.2})O_2$ samples heated to a temperature $>2,000^{\circ}C$, and thus forecast and evaluate radiation hazards threatening humans who cope with the consequences of any accident at a fission reactor loaded by UP mixed oxide $(U_{0.8}Pu_{0.2})O_2$, such as a mixture of 80% U and 20% Pu in weight. Materials and methods: The UP nuclear fuel samples were heated up to a temperature of over $2,000^{\circ}C$ in a suitable assembly (apparatus) at out-of-pile experiments' implementation, the experimental in-depth study of metabolism of active materials in living organisms by means of artificial irradiation of pigs by plutonium. Spectrometric measurements were carried out on the different exposed organs and tissues of pigs for the further estimation of human internal exposure by nuclear materials released from the core of a fission reactor fueled with UP mixed oxide. Results: The main results of the research described are the following: (1) following the research on the influence of mixed fuel fission products (radioactive isotopes being formed during reactor operation as a result of nuclear decay of elements included into the fuel composition) on living organisms, the authors determined the quantities of plutonium dioxide ($PuO_2$) that penetrated into blood and lay in the pulmonary region, liver, skeleton and other tissues; and (2) experiments confirmed that the output speed of plutonium out of the basic precipitation locations is very small. On the strength of the experimental evidence, the authors suggest that the biological output of plutonium can be disregarded in the process of evaluation of the internal irradiation doses.

Study of Plant Growth Inhibition with Edible Sweetener Saccharin and Acesulfame Potassium (식용 감미료 사카린과 에이스셜팜 칼륨의 식물 성장 저해 연구)

  • Donggiun Kim
    • The Journal of the Convergence on Culture Technology
    • /
    • v.9 no.5
    • /
    • pp.661-667
    • /
    • 2023
  • Five commercially available edible sweeteners are used as diet products because they can replace sucrose. In studies on the effects on animals and the human body, stability has been proven by excreting-oriented studies with characteristics of animal cells, and accumulation in small amounts has been ignored. On the other hand, plants can absorb, degrade, and accumulate foreign substances, so the effect of degradability and accumulation potential can be studied using plants. Metabolic effects in plants of commercially available saccharin and acesulfame potassium (Ace K) were tested using germinated barley and bean sprouts. In germinated barley and bean sprouts, saccharin and ace K showed inhibitory effects on plant growth in all organs from low concentrations in leaves, stems and roots. In addition, it can be observed that the symptoms of death appear clearly over time, so it can be seen that they are accumulated in the body of the plant. As the accumulated amount increases, the toxic effect increases and the plant reaches a state where it is unable to metabolize, turning black from the tip of the leaf and reaching a state of death. In order to remove the accumulated artificial sweetener, recovery was attempted by culturing in distilled water, but it acts as a substance that is not degraded and dies without avoiding toxicity. Saccharin and ace K cannot be excreted from the cell. Its toxic effects are thought to be persistent, inhibiting growth and eventually leading to cell death.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

A Study on an Effective Decellularization Technique for a Xenograft Cardiac Valve: the Effect of Osmotic Treatment with Hypotonic Solution (이종 심장 판막 이식편에서 효과적인 탈세포화 방법에 관한 연구; 저장성 용액(hypotonic solution)의 삼투압 처치법 효과)

  • Sung, Si-Chan;Kim, Yong-Jin;Choi, Sun-Young;Park, Ji-Eun;Kim, Kyung-Hwan;Kim, Woong-Han
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.679-686
    • /
    • 2008
  • Background: Cellular remnants in the bioprosthetic heart valve are known to be related to a host's immunologic response and they can form the nidus for calcification. The extracellular matrix of the decellularized valve tissue can also be used as a biological scaffold for cell attachment, endothelialization and tissue reconstitution. Thus, decellularization is the most important part in making a bioprosthetic valve and biological caffold. Many protocols and agents have been suggested for decellularization, yet there ave been few reports about the effect of a treatment with hypotonic solution prior to chemical or enzymatic treatment. This study investigated the effect of a treatment with hypotonic solution and the appropriate environments such as temperature, the treatment duration and the concentration of sodium dodecylsulfate (SDS) for achieving proper decellularization. Material and Method: Porcine aortic valves were decellularized with odium dodecylsulfate at various concentrations (0.25%, 0.5%), time durations (6, 12, 24 hours) and temperatures ($4^{\circ}C$, $20^{\circ}C$)(Group B). Same the number of porcine aortic valves (group A) was treated with hypotonic solution prior to SDS treatment at the same conditions. The duration of exposure to the hypotonic solution was 4, 7 and 14 hours and he temperature was $4^{\circ}C$ and $20^{\circ}C$, respectively. The degree of decellularization was analyzed by performing hematoxylin and eosin staining. Result: There were no differences in the degree of decellularization between the two concentrations (0.25% 0.5%) of SDS. Twenty four hours treatment with SDS revealed the best decellularization effect for both roups A and B at the temperature of $4^{\circ}C$, but there was no differences between the roups at $20^{\circ}C$. Treatment with hypotonic solution (group A) showed a better ecellularization effect at all the matched conditions. Fourteen hours treatment at $4^{\circ}C$ ith ypotonic solution prior to 80S treatment revealed the best decellularization effect. The treatment with hypotonic solution at $20^{\circ}C$ revealed a good decellularization effect, but his showed significant extracellular matrix destruction. Conclusion: The exposure of porcine heart valves to hypotonic solution prior to SDS treatment is highly effective for achieving decellularization. Osmotic treatment with hypotonic solution should be considered or achieving decellularization of porcine aortic valves. Further study should be carried out to see whether the treatment with hypotonic solution could reduce the exposure duration and concentration of chemical detergents, and also to evaluate how the structure of the extracellular matrix of the porcine valve is affected by the exposure to hypotonic solution.

Evaluation of Planning Dose Accuracy in Case of Radiation Treatment on Inhomogeneous Organ Structure (불균질부 방사선치료 시 계획 선량의 정확성 평가)

  • Kim, Chan Yong;Lee, Jae Hee;Kwak, Yong Kook;Ha, Min Yong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.25 no.2
    • /
    • pp.137-143
    • /
    • 2013
  • Purpose: We are to find out the difference of calculated dose of treatment planning system (TPS) and measured dose in case of inhomogeneous organ structure. Materials and Methods: Inhomogeneous phantom is made with solid water phantom and cork plate. CT image of inhomogeneous phantom is acquired. Treatment plan is made with TPS (Pinnacle3 9.2. Royal Philips Electronics, Netherlands) and calculated dose of point of interest is acquired. Treatment plan was delivered in the inhomogeneous phantom by ARTISTE (Siemens AG, Germany) measured dose of each point of interest is obtained with Gafchromic EBT2 film (International Specialty Products, US) in the gap between solid water phantom or cork plate. To simulate lung cancer radiation treatment, artificial tumor target of paraffin is inserted in the cork volume of inhomogeneous phantom. Calculated dose and measured dose are acquired as above. Results: In case of inhomogeneous phantom experiment, dose difference of calculated dose and measured dose is about -8.5% at solid water phantom-cork gap and about -7% lower in measured dose at cork-solid water phantom gap. In case of inhomogeneous phantom inserted paraffin target experiment, dose difference is about 5% lower in measured dose at cork-paraffin gap. There is no significant difference at same material gap in both experiments. Conclusion: Radiation dose at the gap between two organs with different electron density is significantly lower than calculated dose with TPS. Therefore, we must be aware of dose calculation error in TPS and great care is suggested in case of radiation treatment planning on inhomogeneous organ structure.

  • PDF