• Title/Summary/Keyword: Arthroscopic ACL Reconstruction

Search Result 71, Processing Time 0.019 seconds

Pretibial Cyst after Anterior Cruciate Ligament Reconstruction Using bio-absorbable interference screw fixation - A Case Report - (생체분해성간섭나사를 이용한 전방십자인대 재건술 후 발생한 경골 근위부 낭종-증례 보고-)

  • Chun, Keun Churl;Kim, Jung Woo;Kim, Tae Kuyn;Chun, Churl Hong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.11 no.1
    • /
    • pp.57-61
    • /
    • 2012
  • Pretibial cyst formation is a rare complication after anterior cruciate ligament (ACL) reconstruction and there are only few cases reported. Pretibial cyst can be caused by variable reasons. Foreign body reaction due to breakdown of bio-absorbable screw for fixation, graft necrosis at tibial site, joint fluid leakage to tunnel and incomplete incorporation of graft to bony tunnel. The authors experienced one case of massive pretibial cyst after arthroscopic ACL reconstruction using bio-absorbable interference screw in 38-year-old male patient. Thus, authors report this rare case with literature view.

  • PDF

Comparison the Preoperative MRI Findings with Postoperative Arthroscopic Findings on Meniscus Injury with Anterior Cruciate Ligament Rupture (전방십자인대 파열에 동반된 반월상 연골판 손상의 관절경 수술 소견과 수술 전 자기공명영상 검사와의 비교)

  • Sohn, Hong Moon;Lee, Gwang Chul;Kim, Dong Hwi;Park, Sang Soo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.16 no.2
    • /
    • pp.147-152
    • /
    • 2012
  • Purpose: The purpose of this study was to compare the preoperative magnetic resonance image (MRI) findings with postoperative arthroscopic findings on meniscus injury with anterior cruciate ligament (ACL) rupture. Materials and Methods: We reviewed MRI images and arthroscopic findings of 225 patients treated by ACL reconstruction due to rupture, from February 2001 to November 2010. There were 154 cases of meniscus tear in arthroscopic findings. We examined the sensitivity for detecting meniscal tears varied with the presence of a rupture of the ACL, with the location of the tear within the meniscus, and among configurations of meniscal tears. Results: In the presence of a rupture of the ACL, the sensitivity of MRI was 0.88 for medial meniscal tears and 0.69 for lateral meniscal tears. And sensitivity of MRI was lowest in posterior horn and peripheral portion tears in lateral meniscus injury accompanying ACL rupture, sensitivity was low in anterior horn and flap shape tears in medial meniscus injury accompanying ACL rupture. Conclusion: In Meniscus injury with ACL rupture, a special attention shoulder given to the posterior horn and peripheral portion injury in lateral meniscus during arthroscopic surgery due to difficulty in detecting on MRI.

  • PDF

Arthroscopic ACL Reconstruction Using Quadrupled Hamstring Tendon with Tibial Remnant-preserving Technique (슬괵건을 이용하여 경골부 잔류 조직을 보존한 관절경적 전방십자인대 재건술)

  • Kyung, Hee-Soo;Oh, Chang-Wug;Kim, Poong-Taek;Lee, Byung-Woo
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.6 no.2
    • /
    • pp.92-98
    • /
    • 2007
  • Purpose: We evaluated the clinical results of arthroscopic ACL reconstruction using quadrupled hamstring tendon with tibial remnant-preserving technique. Materials and Methods: Thirty-five cases were evaluated from Feb, 2003 to May, 2006. The average interval from injury to surgery was $2.6{\pm}1.6$ months. The cause of injury was mostly sports-related trauma. The average follow-up period was 17 months. Tibial remnant was preserved as much as possible and caution was taken not to damage the remnant during ACL reconstruction. Postoperative rehabilitation was the same as the usual rehabilitation method after ACL reconstruction, except for delaying motion for 2 weeks with an extension locking brace. Clinical evaluation was performed using ROM; Lachman test; pivot-shift test; anterior displacement measurement using KT-2000 arthrometer; Lysholm score and proprioception measured by single limb standing test. Results: There was no limitation of knee motion without contracture. The Lachman test and pivot-shift test were both negative. The side-to-side difference of anterior displacement measured using KT-2000 arthrometer was improved from 6.7 mm to 2.2 mm. The average Lysholm score improved from 81 to 96. The single limb standing test for proprioceptive evaluation showed no significant difference from a normal leg. Conclusion: ACL reconstruction with tibial remnant-preserving technique can preserve mechanoreceptors with prorioception and expect good functional recovery.

  • PDF

Significance of tibial intra-tunnel fixation at Arthroscopic ACL Reconstruction with hamstring tendon (Second-look Arthroscopic Evalution) (자가 슬괵건을 이용한 전방 십자인대 재건술시 경골측 골 터널내 고정의 의의 (이차관절경 검사의 평가))

  • Kim, Young-Chang ;Seo, Seung-Suk;Jung, Kyung-Chil;Gwak, Hey-Chul;Kim, Yoon-Jun;Kim, Jin-Seok
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.2
    • /
    • pp.165-172
    • /
    • 2006
  • Purpose: The purpose of this study is to evaluate the effects of intratunnel fixation in the tibial side on the arthroscopic ACL reconstruction with quadruple hamstring tendon at the second look arthroscopy. Materials and Method: From Dec 1999 to May 2005, we arthroscopically reexamined 32 cases who had been done arthroscopic ACL reconstruction with quadruple hamstring tendons. Hamstring tendons of all cases were fixed at femoral side with RigidfixTM. At the tibial side hamstring tendons were fixed only Post-tie (Group I) or Post-tie combined with IntrafixTM (Group II). At the time of second look arthroscopy mean age of cases was 30 years and mean duration for second look arthroscopy was 21.3 months. We analyzed the results with IKDC score, KT-1000 arthrometer under anesthesia, Telos stress radiography, tibial tunnel widening on the radiography and second look arthroscopic findings. Results: Group II had more superior than group I at side to side differences with KT-1000 and Telos stress radiograph, IKDC score, but the differences were insignificant. At arthroscopic evaluation, Group ll also had more superior than group I at graft tension and graft appearance, graft synovialization, but the differences were insignificant. Tibial tunnel widening in the knee AP radiograph was 2.3 mm in Group I and 1.7 mm in Group II and the difference was significant. (P=0.042) Conclusions: Additional procedure of tibial intratunnel fixation in arthroscopic ACL reconstruction with autogenous hamstring tendon significantly prohibited from tibial tunnel widening but clinical results, radiologic joint stability, findings in second look arthroscopy were insignificantly different. We concluded that Post-tie itself induced satisfactory clinical results, joint stability and graft maturation and that tibial tunnel widening did not affect the results.

  • PDF

Usefulness of Anteromedial Portal for Femoral Tunneling in Anterior Cruciate Ligament Reconstruction (전방십자인대 재건술시 대퇴골 터널에 있어 전내측 삽입구의 유용성)

  • Kang, Min-Soo;Kim, In-Bo;Kim, Kyung-Taek
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.2
    • /
    • pp.118-124
    • /
    • 2008
  • Purpose: Recent development and advances in the arthroscopic surgical techniques for anterior cruciate ligament(ACL) reconstruction have led to the ideal location for more oblique anatomic point of the femur from 10 to 10:30 o'clock(in the right knee) and from 2 to 1:30 o'clock(in the left knee) in the frontal plane. This study was performed to compare the operative methods and the radiologic results of the femoral tunnels made through the tibial tunnel(trans-tibial approach) and the anteromedial portal. Materials and Methods: From January 2003 to May 2004, on hundred reconstructions of ACL were performed. Group I(the femoral tunnel made through the tibial tunnel) consisted of 50 cases and group I(the femoral tunnel made through the anteromedial portal) consisted of 50 cases. The operative methods and the radiographic results of the femoral tunnels were compared. Results: Femoral tunnel was made more easily at more oblique anatomic point in group II than in group I. In group II, better visual field was achieved at the angle of 100? flexion of the knee joint, the risks of the posterior cortical breakage and the tunnel-graft mismatching were reduced more, and the divergence of femoral interference screw from the radiograph decreased more than in group I(p<0.05). The angle between the femoral tunnel and the longitudinal axis of ACL increased in group II. Conclusion: Anteromedial portal technique was useful for femoral tunneling toward 10 to 10:30 o'clock(in the right knee) and 2 to 1:30 o'clock(in the left knee) in ACL reconstruction. Level of Evidence:Level III, case-control study.

  • PDF

Comparative Study of Arthroscopic ACL Reconstruction Using Bone-Patellar Tendon-Bone Versus Four-Stranded Semitendinosus-Gracilis Tendon (관절경적 전방십자인대 재건술시에 골-슬개건-골과 네가닥 반건양건-박건을 이용한 방법의 비교연구)

  • Kim, Jin Goo;Lim, Young;Kim, Byung Jik;Ko, Han Suk;Moon, Hyung Tae
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.2
    • /
    • pp.107-113
    • /
    • 1998
  • This study is retrospective analysis of 31 patients treated by arthroscopically assisted ACL reconstruction, from September 1995 to September 1996. ACL reconstructions using autogenous bone patellar tendon bone (B-PT-B) were done in 18 patients, and using hamstring tendon were done in 13 patients. We used four-stranded hamstring tendon grafts and fixed the grafts using Endobutton and screw. The mean postoperative Lysholm knee score was 87.2 points in B-PT-B. group, and 89.0 points in hamstring tendon group. There were no clinically significant results between two groups in Telos test, quadriceps atrophy, Lachman test, anterior drawer test and pivot shift test, but the incidences of anterior knee pain were lower in hamstring group. Four-stranded hamstring tendon graft showed enough stability and good functional outcome similar to that of patellar tendon graft, and had an advantage of quicker return of quadriceps function and less donor site morbidity.

  • PDF

Notchyplasty with Flexible Reamer (대퇴과간절흔 성형술에서 유연성 연마기를 이용한 방법)

  • Chae, In-Jung;Lee, Kwang-Suk;Back, Jong-Ryoon
    • Journal of the Korean Arthroscopy Society
    • /
    • v.1 no.1
    • /
    • pp.123-127
    • /
    • 1997
  • Arthroscopic anterior cruciate ligament reconstructions using bone-patella tendon-bone have been considered the best method by which others are compared. The notchyplasty is one of the important steps of this procedure and it is emphasized recently to prevent retear of the reconstructed ACL caused by impingement. However, until now, there is controversy about adequate amount of notchyplasty. Also, it is hard to examine the adequacy of notchyplasty even in the arthroscopic field, The purpose of this paper is to describe the surgical technique of notchyplasty, using the flexible reamer and preliminary result of its operation. In this study the results of ACL reconstruction with notchyplasty which is made by us were analized from January. 1994 to December, 1995. The results were as follows: 1. The notchyplasty with flexible reamer is the method that can be obtained adequate amount of removal, perfectly smooth notchyplasty. 2. The range of motion of the affected knee joint was normal ROM after post operation 6 month. 3. In the last follow up, 2 cases were positive in anterior drawer test 4 cases were positive in Lachmann's test and 1 knee was positive in Pivot shift test 4. Average Lysholm knee scoring scale was 70 points at preoperative and 92 points at the last follow up.

  • PDF

Revision of Failed ACL Reconstruction - Early Result - (전방 십자 인대 재 재건술 단기 추시 결과)

  • Ahn Jin-Hwan;Cho Yong-Jin;Lee Yong-Seuk;Shin Seong-Kee
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.169-175
    • /
    • 2003
  • Purpose : The purpose was to evaluate the early result of revision of failed anterior cruciate ligament (ACL) reconstruction. Materials and Methods : From August 1997 to February 2002, this report presents the findings of 18 patients who had revision surgery for failed ACL reconstruction. There was an average of 39 $(7\~120)$months from index procedure to the time of revision. Allografts were used in 14 $(78\%)$cases and autografts were used in 4 $(22\%)$cases and the revision procedures were assisted by arthroscopic technique. The majority of chief complaints were instability in 16 $(89\%)$cases. Sixteen $(89\%)$ cases had 1 previous reconstruction, 2 $(11\%)$ cases had 2. Before and after revision, patients were evaluated by Lachman test, pivot shift test, KT 2000, radiographs, Lysholm score and HSS score and subjective satisfaction. Results : Average length of followup was 27 $(12\~60)$months. Preoperatively, all cases were positive in Lachman test and pivot shift test. After revision the majority of cases were negative. Objectively improving stability was confirmed by KT 2000 and all average KT 2000 was 7.75 $(3.5\~12.5)$mm preoperatively and 2.36 $(1.0\~6.0)$mm at final followup. Lysholm score and HSS score were also improved from 72.6 $(66\~77)$ and 72.5 $(68\~78)$ preoperatively to 89.2 $(80\~92)$ and 88.2 $(81\~92)$ at final followup. Most $(89\%)$ of patients were satisfied with their results. The most common causes of failed ACL reconstruction were malposition of femoral tunnel in 11 $(61\%)$cases. Conclusion : Arthroscopic revision ACL surgery with adequate graft for failed ACL reconstruction was successful in objectively and subjectively improving stability. However, considering the most common causes of failure after ACL reconstruction were errors in surgical technique, it is important that the primary ACL reconstruction should be performed with correct surgical technique.

  • PDF