• Title/Summary/Keyword: Arterial pulse wave

Search Result 95, Processing Time 0.058 seconds

Association of Uric Acid Levels with Arterial Stiffness in Korean Women and Non-smoking Men

  • Sull, Jae Woong;Koh, Eun Na;Cho, Sung Kweon;Bae, Hyung-Joon;Jee, Sun Ha
    • Biomedical Science Letters
    • /
    • v.23 no.3
    • /
    • pp.201-207
    • /
    • 2017
  • Measuring the pulse wave velocity (PWV) is a non-invasive method for evaluating the stiffness of the vessel wall. While previous studies investigated the association of uric acid level with arterial stiffness, most did not consider smoking status and obesity as covariates. The objective of this study was to investigate the relationship between uric acid levels and arterial stiffness, considering smoking status and obesity. We studied 3390 subjects (1940 males and 1450 females). Abnormal PWV was also defined as the highest quartile of values in the subjects. Data were analyzed using Pearson correlation, t-test, and multiple regression analysis. Approximately 41.9% of men and 3.7% of women were current smokers. Prevalence of hypertension was 11.4% in men and 7.0% in women. In women, hyperuricemia was associated with abnormal PWV (OR 1.58; 95% CI 1.03~2.43). Hyperuricemia was also associated with abnormal PWV (OR 2.37; 95% CI 1.01~5.59) in non- or light male smokers with normal blood pressure. This study suggests that uric acid is associated with arterial stiffness in women and non-smoking men.

Simulation Analysis of Spatially Arterial Pulse Wave using Two-dimensional Array Sensors with Magnetoresistive Device (2차원 배열 자기저항소자를 이용한 공간 맥진파형의 전산모사 분석)

  • Kim, M.S.;Kim, S.W.;Kim, G.W.;Lee, S.J.;Lee, S.G.;Lee, H.S.;Park, D.H.;Hwang, D.G.;Lee, S.S.
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.6
    • /
    • pp.307-310
    • /
    • 2005
  • To get the spatial feature of arterial pulse, we designed spatial pulse diagnostic apparatus (SPDA) using a 2-dimensional magnetoresistive sensor array. The magnetic field distribution fur magnet may was simulated using finite element method. We recognized that the field distribution of parallel magnet mays was more sensitive and uniformed than that of perpendicular one. Also the spatial displacements of magnet array were agreed with the output signal of magnetic tunnel junction (MTJ) sensor array.

A Wrist Watch-type Cardiovascular Monitoring System using Concurrent ECG and APW Measurement

  • Lee, Kwonjoon;Song, Kiseok;Roh, Taehwan;Yoo, Hoi-jun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.16 no.5
    • /
    • pp.702-712
    • /
    • 2016
  • A wrist watch type wearable cardiovascular monitoring device is proposed for continuous and convenient monitoring of the patient's cardiovascular system. For comprehensive monitoring of the patient's cardiovascular system, the concurrent electrocardiogram (ECG) and arterial pulse wave (APW) sensor front-end are fabricated in $0.18{\mu}m$ CMOS technology. The ECG sensor frontend achieves 84.6-dB CMRR and $2.3-{\mu}Vrms$-input referred noise with $30-{\mu}W$ power consumption. The APW sensor front-end achieves $3.2-V/{\Omega}$ sensitivity with accurate bio-impedance measurement lesser than 1% error, consuming only $984-{\mu}W$. The ECG and APW sensor front-end is combined with power management unit, micro controller unit (MCU), display and Bluetooth transceiver so that concurrently measured ECG and APW can be transmitted into smartphone, showing patient's cardiovascular state in real time. In order to verify operation of the cardiovascular monitoring system, cardiovascular indicator is extracted from the healthy volunteer. As a result, 5.74 m/second-pulse wave velocity (PWV), 79.1 beats/minute-heart rate (HR) and positive slope of b-d peak-accelerated arterial pulse wave (AAPW) are achieved, showing the volunteer's healthy cardiovascular state.

The Effects of Plasma Homocysteine Concentration on Upper Arm-Ankle Pulse Wave Velocity (혈장 호모시스테인 농도가 상완-발목 맥파 속도에 미치는 영향)

  • Kang, Ji-Hun;Shin, Sang-Yol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.673-680
    • /
    • 2019
  • This study was conducted to investigate the effects of plasma homocysteine concentration on the brachial-ankle pulse wave velocity between the normal homocysteine group and the asymptomatic high homocysteine group. 435 subjects who visited the general health examination center from April 1 to October 31, 2016, as well as to compare the direct correlation of the brachial-ankle pulse wave velocity, which indirectly reflects the homocysteine test and arterial stiffness, as a predictor of future cardiovascular outcome. As a result of the study, age, waist circumference, BUN, and plasma creatinine were significantly higher, and HDL was significantly lower in the high homocysteine group (> $15{\mu}mol/L$) than in the normal homocysteine group (< $15{\mu}mol/L$) (p=0.05). In addition, homocysteinemia was associated with smoking and drinking (p<0.001) and was significantly higher in males (p<0.001). The right and left brachial-to-ankle pulse wave velocities were significantly higher in the high homocysteine group (right p<0.001, left p=0.003) before calibrating the relevant variables. There was no significant difference between right and left brachial-to-ankle pulse wave velocities after calibrating the relevant variables. Therefore, further studies on the independent association of lowering homocysteine concentration and prevention of cardiovascular disease and the relationship between homocysteine and renal function are needed.

On Study of Pulse Wave Signal According to Postural Change Using Finger Plethysmography (손가락 끝 용적맥파를 이용한 자세변화에 따른 맥파 신호에 관한 연구)

  • Choi, B.C.;Kim, C.H.;Jung, D.K.;Suh, D.J.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1998 no.11
    • /
    • pp.125-126
    • /
    • 1998
  • Pulse conduction velocity is determined by areterial compliance, which is changed by lateral pressure of arterial wall. Hydrostatic pressure of the limb vessel is changed by body position, especially in elevated arm. The arterial pulse in the finger causes the blood volume to change, changing the optical density of the blood. Photoplethysmograph of index finger was obtained by LED and phototransistor. Pulse transmission time(PTT) was measured by the interval between the peak of ECG R wave and the peak of the finger plethysmogram. PTT was increased by upward position of arm, and decreased by downward position of the arm compared to horizontal position. This result suggests that relationship between finger plethysmography and postural change could be applied to evaluate clinical cardiovascular status.

  • PDF

Comparison of Simultaneously Measured Pulse Waveforms from Both Hands using Permanent Magnet-Hall Pulsimeter Sensor (영구자석-홀 맥진센서를 이용한 양손 동시측정 맥진파형 비교 연구)

  • Yoo, Gi-Doo;Hwang, Sung-Gi;Lee, Sang-Suk
    • Journal of the Korean Magnetics Society
    • /
    • v.22 no.1
    • /
    • pp.27-31
    • /
    • 2012
  • Two radially arterial pulses of both hands using the prototype of a clamping clip pulsimeter equipped with permanent magnet and Hall device are compared and analyzed. The phase difference of two pulse wave signals is dominantly presented from the simultaneous measuring clinical pulse wave signals for twenty two male participants at their 20's. It is possible to analyze that the fast and slow pulse wave for right hand and left hand depend on the muscle property of arms rather than the total length of blood vessel due to cardiovascular circulatory system.

Effects of Elastic Band Resistance Training on Body Composition, Arterial Compliance and Risks of Falling Index in Elderly Females (탄성밴드 저항운동이 고령여성의 신체조성, 혈관탄성 및 낙상위험도지수에 미치는 영향)

  • Park, Hyeok;Kim, Dayeol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.18 no.3
    • /
    • pp.199-208
    • /
    • 2017
  • Both cardiovascular diseases caused by decreased body composition and arterial compliance and falling induced by loss of muscle mass are frequent occurrences in the elderly. Therefore, elderly people are advised to perform elastic band resistance exercises to improve their body composition and arterial compliance. Thus, the purpose of this study was to examine the effects of 12 weeks of elastic band resistance training on the body composition, arterial compliance and falling index in elderly females (> 65 years). The elastic band resistance exercise program was administered 3 times per week for 60 minutes each time for 12 weeks. In addition, the exercise intensity was set to 11-14 on the Borg scale (6-20). Before and after the training period, the body composition (body weight (BW), muscle mass, % body fat, body mass index (BMI)), arterial compliance (ankle brachial index (ABI) and pulse wave velocity (PWV)) and risk of falling index were determined. (After the program?), the BW (p=.003), BMI (p=.002), PWV (p=.017) and risk of falling (p=.037) in the exercise group were significantly reduced, whereas the BW (p=.009) and BMI (p=.009) in the control group were significantly increased. In conclusion, the body weight, BMI and arterial compliance of elderly females were positively changed by the elastic band resistance training. Thus, the elastic band resistance exercise may be useful for elderly people to prevent metabolic syndrome and cardiovascular diseases and to reduce their risk of falling.

The Analysis of Pulse Wave Velocity of Jeju female divers (제주 해녀의 맥파전도속도 분석)

  • Lee, Han-Young
    • Journal of Digital Convergence
    • /
    • v.13 no.9
    • /
    • pp.515-521
    • /
    • 2015
  • In this study, we tried to analyze arterial stiffness of Jeju female divers who diver into cold water without the assistance of oxygen. For this purpose we measured pulse wave velocity and ankle-brachial index of Jeju female divers and same aged females who didn't have any cardiovascular risk for comparing the vascular stiffness. The results were the following : First, the light-femoral pulse wave velocity of Jeju female divers was significantly lower than normal women of the same ages. Second, Jeju female divers's ABI showed higher tendency than normal same aged women. These result showed that Jeju female divers' body had been completed for adaptation to low temperature and high pressure water environment through a long-term immersion activities in old age, as well as due to higher physical activity levels of Jeju female divers peripheral vascular resistance was not reduced.

Development of the Cardiovascular Simulator for Pulse Diagnosis Study (맥진연구를 위한 심혈관계 시뮬레이터의 개발)

  • Lee, Ju-Yeon;Shin, Sang-Hoon
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.16 no.1
    • /
    • pp.19-26
    • /
    • 2012
  • Objectives The aim of this study is to develop a cardiovascular simulator that can reproduce blood pressure pulse and blood flow similar to those of the human body. Methods In order to design a system similar to the human cardiovascular system, the required performances were determined by investigating the hemodynamic characteristics of the heart and the arterial system. Main organ to be imitated is heart in simulator. The rest of the system was minimally designed. Also, a blood pressure and blood flow measurement system was developed for measuring the results. Results The developed system showed blood pressure pulse at similar range of the human aorta. The result waveform include primary wave caused by ventricular systole except reflected wave. Conclusions The blood pressure and blow flow patterns were replicated by the simulator. These patterns were similar to those of the human body. The system will play an important role in studying pulse diagnostics.

Fuzzy Simulation of a Multi-electronic Acupuncture System and Clip-type Pulsimeter Equipped with a Magnetic Sensing Hall Device

  • Hong, You-Sik;Rhee, Jin-Kyu;Kim, Han-Kyu;Son, Il-Ho;Yoon, Woo-Sung;Lee, Nam-Kyu;Park, Do-Young;Kim, Keun-Ho;Kim, Yong-Jin;Khajidmaa, P.;Lee, Sang-Suk
    • Journal of Magnetics
    • /
    • v.19 no.3
    • /
    • pp.255-260
    • /
    • 2014
  • A portable clip-type pulsimeter equipped with a magnetic sensing Hall device has been developed to raise the accuracy of oriental disease diagnosis and therapy by convergence of magnetism and oriental medicine. To improve accuracy and reliability of conventional pulsimeter due to subjective analysis of the pulse wave and measuring position dependency of the arterial pulse sensor, the fuzzy algorithm was applied to analyze the strong- and weak-pulse wave symptom. Optimal time for electronic acupuncture was calculated using fuzzy rules and interference were drawn from objective data in view of pre-treatment. Moreover, the electrical characteristics of the pain parts that respond to acupuncture point were applied in view of post-treatment to propose the scientific pulse wave algorithm and simulation experiment.