• Title/Summary/Keyword: Arrester Deterioration

Search Result 36, Processing Time 0.024 seconds

Degradation Properties of ZnO Surge Arresters Due to Lightning Impulse Currents (뇌임펄스전류에 의한 ZnO 피뢰기의 열화특성)

  • Lee, Su-Bong;Lee, Bok-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.4
    • /
    • pp.79-85
    • /
    • 2009
  • This paper describes the degradation properties of ZnO surge arresters impressed by lightning impulse currents. To investigate the deterioration behaviors of ZnO surge arresters due to lightning surges, the 8/20[${\mu}s$], 2.5[kA] standard lightning impulse currents were injected to the ZnO surge arrester under test. The power frequency AC and DC leakage currents flowing through the ZnO surge arresters with and without the injection of lightning impulse currents were measured. As a result, the leakage currents are increased and the asymmetry of the AC leakage current is pronounced as the number of injection of the impulse current increases. The ZnO grain of the surge arrester without the injection of lightning surges are uniform but the ZnO grain of the ZnO surge arrester with the injection of lightning impulse currents are deformed. Also, it was found that the decrease of the $Bi_2O_3$ due to the lightning impulse current leads to the lack of grain boundary layer and the current concentrated by the lack of grain boundary layer play an important role to degrade nonlinear property of ZnO surge arrester blocks.

Comparison on electrical characteristic changes of ZnO Arrester Blocks by Lightning Impulse Current (ZRO 피뢰기 소자의 뇌충격전류에 의한 전기적 특성 변화 비교)

  • Han, Joo-Sup;Park, Young-Ho;Kil, Gyung-Suk;Kim, Chan-Young
    • Proceedings of the KIEE Conference
    • /
    • 1999.11d
    • /
    • pp.1108-1110
    • /
    • 1999
  • This paper describes the comparison results on electrical characteristic changes of ZnO blocks by lightning impulse current. The five types of ZnO blocks used in lightning arrester for distribution lines have been estimated repeatedly till about 400 times by a standard lightning impulse current of 3kA, $8/20{\mu}s$, and changes of the performance characteristics of them to operation times were examined and compared quantitatively every fifty times discharge. It is expected that the result will be useful to diagnose the soundness of ZnO blocks or lightning arresters, and to develope deterioration diagnosis device for them.

  • PDF

Harmonics Analysis of Leakage Current due to Artificial Contamination of Distribution Arresters (배전용 피뢰기의 인공오손에 의한 누설전류의 고조파 분석)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.9
    • /
    • pp.1306-1313
    • /
    • 2012
  • This paper reports the contamination performance of two distribution arresters (new and used ones) tested under three different contaminant conditions - clean fog, ESDD (equivalent salt deposit density) level (A, B, C, and D), and kaolin contamination conditions, and their leakage current, total leakage current, and component of the resistive leakage current were measured in order to diagnose arrester deterioration. The 3rd harmonics was larger than 5th and 7th ones for the arrester under the clean fog, and as the ESDD contamination level was applied, 5th one became relatively larger than 3rd one. Therefore, these results indicated that the resistive leakage current could be used for the diagnosis of the arresters.

A Study on the Consecutive Failure Due to Deterioration in Surge Arresters of the Offshore Wind Farm (해상 풍력발전단지에서 뇌격 시 서지어레스터 열화로 인한 연계 고장 분석)

  • Kim, Jin-Hyuk;Kim, Kyu-Ho;Lee, Jea-Kyun;Woo, Jung-Wook
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.10
    • /
    • pp.1265-1270
    • /
    • 2018
  • One of the ways to improve the stability of power facilities used in power systems is to use power surge arresters and to protect against transient overvoltages and surges in normal operation. Also it is important to reduce the impact of lightning strikes because lightning can create overvoltage in the grid of the wind turbine and affect power quality. So This paper analyzes the effects of overvoltage and adjacent turbines due to single strike and multi strike to ground impedance changes when the surge arrester is deteriorated in a wind power farm.

A New Approach to On-Line Monitoring Device for ZnO Surge Arresters

  • Lee Bok-Hee;Gil Hyoung-Jun;Kang Sung-Man
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • v.5C no.3
    • /
    • pp.131-137
    • /
    • 2005
  • This paper describes a new approach to the algorithm and fundamental characteristics of the device for monitoring the leakage currents flowing through zinc oxide (ZnO) surge arresters. In order to obtain a technique for a new on-line monitoring device that can be used in the deterioration diagnosis of ZnO surge arresters, the new algorithm and on-line leakage current detection device for extracting the resistive and capacitive currents using the phase shift addition method were proposed. The computer-based on-line monitoring device can sense accurately the power frequency leakage currents flowing through ZnO surge arresters. The on-line leakage current monitoring device of ZnO surge arresters proposed in this work has the high sensitivity compared to the third harmonic leakage current detection devices. As a consequence, it was found that the proposed leakage current monitoring device would be useful for forecasting the defects and degradation of ZnO surge arresters.

The Transient State characteristic and Consecutive Failure Analysis of The Offshore Wind Farm (낙뢰로 인한 해상풍력발전단지 과도상태 및 연계고장 분석)

  • Seo, Jin-Gyu;Kim, Kyu-Ho;Park, Sang-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.239-240
    • /
    • 2015
  • This paper presents the transient state characteristic and single phase ground fault occurred by deterioration of surge arrester when offshore wind turbine is struck by lightning strike. The wind turbine and submarine cable data are based on the 2.5GW offshore wind farm planned in South Korea Southwest Seashore. During lightning strikes, additional ground fault can lead to damage of the generation components. So, the sensitive analyses are conducted in order to investigate the effects of lightning strike on offshore wind farm.

  • PDF