• Title/Summary/Keyword: Arrangement of Column

Search Result 91, Processing Time 0.025 seconds

Establishment of Rebar Quantity Estimation in BIM-based Initial Design Phase (BIM기반 초기 설계 단계 철근 물량 산출 프로세스 구축)

  • Song, Chi-Ho;Kim, Chee-Kyeong;Lee, Si Eun;Choi, Hyunchul
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.29 no.5
    • /
    • pp.447-454
    • /
    • 2016
  • In the meantime, looking at the present status of how to estimationte the quantity of rebar based on 3D BIM getting the limelight in these days, commercial BIM tools provide rebar modeling functions however it takes a vast amount of modeling time for modeling of rebar in use of that function hence there is no BIM software at present for practical use. Therefore, in this study, we organized and presented a practical rebar quantity estimationtion process in BIM-based design work-site and intended to develop a program named Rebar Automatic Arrangement Program - hereinafter called RAAP - which enables automatic rebar arrangement based on much more precise cross-sectional information of bars in column, beam, slab and wall than the one from existing 2D method under the conditions without any cross-sectional information in the initial design phase. In addition, we intended to establish rebar quantity estimationtion process in the initial design phase through interworking of modeling & quantity estimationtion functions in consideration of joint, anchoring length of BuilderHUB as a BIM software with RAAP. The results from this study are practical in developing a technology that is able to estimationte quantity with more improved reliability than the one from existing 2D-based methods with less effort when the quantity of framework is estimationted in the uncompleted state of cross-sectional design for structural members in the initial design phase of a construction project. And it is expected that it could be utilized as a basic study from which a reasonable quantity estimationtion program can be established in the initial design phase.

A Study on the Ambiguity of the Boundary in the Inside Space through the Composition of Section (단면 구성을 통한 공간 내부 경계의 모호성에 관한 연구)

  • Lim Jong-Yup;Lee Hong
    • Korean Institute of Interior Design Journal
    • /
    • v.14 no.6 s.53
    • /
    • pp.95-102
    • /
    • 2005
  • The purpose of this study was to analyze the ambiguity of the boundary through the composition of section. The building means the compose of the inside space by physical shell. Inside space that has boundary factors like floor, wall, roof and column is surrounded outside space. The factors which compose the boundary was expressed by architects as various analysis, but it has changed as changing of paradigm and information revolution. The inside space and outside space were connected through the system arrangement, so various space could construct by an aspect of relation. The history of architecture was written as the establishment of in-out space by architectural boundary factors, but the space could not divide definitely, composed complex structure, could experience various recognition. The existing study which is focused on Ambiguity of the Boundary is just focused on contemporary architecture. Ambiguity of the Boundary is developed by using glass. The transparency of glass removed the boundary of space, so it can be created free wall, continuity of view. It was Influenced the boundary of the sight and changed the expression of boundary between the space. This study is to analyze the change of boundary awareness and find the ambiguity of boundary in the section.

Image Capturing of Dispersed Phases in DCHXs by Electric Tomography

  • Chun, Won-Gee;Kim, Min-Chan;Lee, Heon-Ju;Kang, Yong-Heack;Kwon, Hyok-Bo
    • Journal of the Korean Solar Energy Society
    • /
    • v.21 no.2
    • /
    • pp.69-78
    • /
    • 2001
  • This paper introduces the physical phenomena involved in Direct Contact Heat Exchangers (DCHXs) and also investigates the possibility of applying of EIT(Electrical Impedance Tomography) technique for capturing the images of dispersed phases as they stream through a stagnant body of water. A number of cases are studied where two dimensional cross-sectional static images are given for fictitious and actual masses present in a column of water(saline solution). In most direct contact liquid-liquid heat exchangers, oil or hydrocarbon with a density different(lighter or heavier) from water is normally used as dispersed working fluid. The main difficulty that arises with this arrangement lies in the elucidation of complicated flow field where the dispersed phase fluid tends to change its shape and size constantly during its journey through the other phase(water). This paper presents a number of results with different types of dispersed phases that are immiscible with water. The EIT technique has been employed in this context to test its applicability in capturing the dynamic images of dispersed phases. It shows static images of dispersed phases where dynamic images could be obtained by simply extending the algorithms and strategies employed in the present analysis.

  • PDF

A Study on Planning and Composition of Module Unit in Korean Traditional House (전통한옥 '칸'의 계획과 구성에 관한 연구)

  • Kim, Jong-Hoon
    • Journal of the Korean housing association
    • /
    • v.23 no.4
    • /
    • pp.41-48
    • /
    • 2012
  • The purpose of the study, approaching from the aspect of the construction technologies, is to determine the architectural techniques of traditional wood architects in existence, through which the systems and techniques that create the inherent characteristics of Korean Architecture are clarified. With understanding traditional construction system and focusing on the fact that built environment results from the consistent standards and technologies of architects, this study inquires into the systematic standard and its formation that present in the process of planning for the overall scale and shape of a building from the following (four) perspectives. The study determines the characteristics of '間(Kan)' (unit; fundamental unit that measures Korean traditional houses) and the methods of columns disposition of which the '間 (Kan)' is made up. Once the necessary spaces are decided according to the size of a building, then floor plans are drawn with the standard unit, '間(Kan)'. The '間(Kan)', as a modular unit, is not only composing the floor plans, but also functioning as an Area unit, Space unit and Structural unit. Composition of '間(Kan)' varies with disposition of columns, and therefore multiform of floor and spaces are created. In this study, the '間(Kan)', as a standard unit, is used in the form of specific size and area, and it is demonstrated how the floor plans are developed by organizing the columns in accordance with the spaces requested.

Structural Design of Nakanoshima Festival Tower West that Achieved High-Grade Seismic Performance

  • Kumano, Takehito;Yoshida, Satoshi;Saburi, Kazuhiro
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.3
    • /
    • pp.217-226
    • /
    • 2017
  • This paper summarizes the structural concept and design of the "Nakanoshima Festival Tower West" in Osaka, Japan, which is 200m high and has a super-high damping system. Its superstructure is mainly composed of a central core and outer tube frames. It has a bottom truss structure at the boundary between the low-rise and mid-rise sections of the building, where the column arrangement is changed. Besides, the high-rise section of the building has a neck truss structure. These truss structures smoothly transfer the axial forces of the columns and reduce the flexural deformations induced by horizontal loads. Oil dampers with extremely high damping capacity are installed in the rigid walls named the "Big Wall Frames" of the low-rise section. Moreover, many braces and damping devices are well arranged in the center core of each story. The damping effects of these devices ensure that all structural members are remain within the elastic range and that story drifts are within 1/150 in large earthquakes. This super-high damping structure in the low-rise section is named the "Damping Layer". The whole structural system is named the "Super Damping Structure". The whole structural systems enhance the building's safety, comfort and Business Continuity Planning (BCP) under large earthquakes.

Cloning of p-Hydroxybenzoate Degradation Genes and the Overexpression of Protocatechuate 4,5-Dioxygenase from Pseudomonas sp. K82

  • Yoon, Young-Ho;Park, Soon-Ho;Leem, Sun-Hee;Kim, Seung-Il
    • Journal of Microbiology and Biotechnology
    • /
    • v.16 no.12
    • /
    • pp.1995-1999
    • /
    • 2006
  • Pseudomonas sp. K82 cultured in p-hydroxybenzoate induces protocatechuate 4,5-dioxygenase (PCD 4,5) for p-hydroxybenzoate degradation. In this study, a 6.0-kbp EcoR1 fragment containing p-hydroxybenzoate degradation genes was cloned from the genome of Pseudomonas sp. K82. Sequence analysis identified four genes, namely, pcaD, pcaA, pcaB, and pcaC genes known to be involved in p-hydroxybenzoate degradation. Two putative 4-hydroxyphenylpyruvate dioxygenases and one putative oxidoreductase were closely located by the p-hydroxybenzoate degradation genes. The gene arrangement and sequences of these p-hydroxybenzoate degradation genes were similar to those of Comamonas testosteroni and Pseudomonas ochraceae. PcaAB (PCD4,5) was overexpressed in the expression vector pGEX-4T-3, purified using a GST column, and confirmed to have protocatechuate 4,5-dioxygenase activity. The N-terminal amino acid sequences of overexpressed PCD4,5 were identical with those of purified PCD4,5 from Pseudomonas sp. K82.

Design and consturction of single drilled shaft foundation (단일 현장타설말뚝 기초의 설계 및 시공)

  • Jeon, Kyung-Soo;Kim, Kyung-Suk;Kim, Jeong-Yeul
    • 기술발표회
    • /
    • s.2006
    • /
    • pp.86-100
    • /
    • 2006
  • The single drilled shaft foundation has been used in the other countries, but has not used in South Korea at all This foundation is very effective and economic method in South Korea which is easy to meet a good rock mass within 50m depth from the ground We have many experiences to construct 1.52 5m drilled shaft foundations and ability to construct 30m drilled shaft foundation without special efforts The soil behavior is nonlinear, but it can be proposed in linear in practical purpose on bridges. The elastic modulus of soil can be rationally obtained by the method of Road Bridge Design Manual in South Korea using the Schmertmann(1970)'s proposal, and the elastic modulus of rock can be obtained by the field test. In seismic design the column and drilled shaft must be restricted to the elastic design because the behavior of this foundation is flexible and the arrangement of the rebars makes the various defect In this paper the design criteria is compared with FHWA design criteria, and the design criteria is proposed in consistent with Road Bridge Design Manual in South Korea. The single drilled shaft foundation of a test bridge was constructed in the Iksan-Jangsoo highway, and we checked its stability, workability and economy

  • PDF

Structure Recognition Method of Invoice Document Image for Document Processing Automation (문서 처리 자동화를 위한 인보이스 이미지의 구조 인식 방법)

  • Dong-seok Lee;Soon-kak Kwon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.28 no.2
    • /
    • pp.11-19
    • /
    • 2023
  • In this paper, we propose the methods of invoice document structure recognition and of making a spreadsheet electronic document. The texts and block location information of word blocks are recognized by an optical character recognition engine through deep learning. The word blocks on the same row and same column are found through their coordinates. The document area is divided through arrangement information of the word blocks. The character recognition result is inputted in the spreadsheet based on the document structure. In simulation result, the item placement through the proposed method shows an average accuracy of 92.30%.

A Study on Ion Exchange Characteristics with Arrangement of Ion Exchange Column (이온교환 수지탑 배열에 따른 이온교환 특성 연구)

  • Jeong, Hyun-Jun;Ahn, Hyun-Kyoung;Rhee, In-Hyoung
    • Proceedings of the KAIS Fall Conference
    • /
    • 2006.05a
    • /
    • pp.596-598
    • /
    • 2006
  • 본 논문에서는 수지 조성비 및 수지탑 배열이 이온교환 특성에 미치는 영향을 조사하기 위하여 전해질 농도는 $Na^+\;125ppm$, $Cl^-\;315ppm$ 유속은 500ml/min, 이온교환 수지는 ROHM&HAAS IR 120 양이온 수지와 ROHM&HAAS IRA 402 음이온 수지를 사용하였고, 수지탑 배열은 혼상-혼상-음이온, 혼상-음이온-혼상, 음이온-혼상-혼상 수지탑 순으로, 이온교환 수지탑의 양 음이온교환 수지의 조성 비율은 1:1, 1:2, 1:3 로 변화하여 실험한 결과 이온교환 수지의 조성비 변화에서는 양 음이온교환 수지 조성비 1:2의 경우 1:1, 1:3의 경우보다 파과시간이 연장되었다. 수지탑 배열이 음이온-혼상-혼상 수지탑인 경우 혼상-혼상-음이온 수지탑 배열과 파과시간을 비교해보면 약 60% 파과시간이 연장되었다. 따라서 수지탑 배열은 음이온-혼상-혼상 수지탑 순으로, 수지 조성비는 1:2일 때 가장 효율적인 것으로 나타났다.

  • PDF

Evaluation of Minimum Spiral Reinforcement Ratio of Circular RC Columns (철근콘크리트 원형기둥의 나선철근 최소철근비에 대한 평가)

  • Kim, Young-Seek;Kim, Hyeong-Gook;Park, Cheon-Beom;Kim, Sang-Woo;Kim, Kil-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.1-9
    • /
    • 2017
  • Spiral reinforcement in a circular column plays an effective role in the ductile behavior of a column through position fixing and buckling restraining of the longitudinal reinforcement, and confining core-concrete. Each country has suggested the minimum volumetric ratio of spiral reinforcement in order to secure the ductility of concrete columns. The minimum volumetric ratio of spiral reinforcement suggested by ACI 318-14 and the national concrete structure design standard was developed based on the theory of Richard et al. (1928); furthermore it has been used until now. However, their theory cannot consider the effects of high strength concrete and high strength reinforcement, and arrangement condition of the spiral reinforcement. In this study, a modified minimum volumetric ratio equation is suggested, which is required to improve the ductility of reinforced concrete circular columns and to recover their stress. The modified minimum volumetric ratio equation suggested here considers the effect of the compressive strength of concrete, the yield strength of spiral reinforcement, the cross sectional area of columns, the pitch of spiral reinforcements and the diameter of spiral reinforcement. In this paper, the validity of the minimum volumetric ratios from ACI 318-14 and this study was investigated and compared based on the results of uniaxial compression experiment for specimens in which the material strength and the spiral reinforcements ratio were used as variables. In the end of the study, the modification method for the suggested equation was examined.