• 제목/요약/키워드: Argon2

검색결과 722건 처리시간 0.03초

Spatial Distribution of Excited Argon Species in and Inductively Coupled Plasma

  • 최범석
    • Bulletin of the Korean Chemical Society
    • /
    • 제19권11호
    • /
    • pp.1172-1174
    • /
    • 1998
  • Spatial(radial and height) distributions of excited argon species are measured for an inductively coupled plasma under five operating conditions: 1) no carrier gas, 2) carrier gas without aerosol, 3) carrier gas with desolvated aerosol, 4) carrier gas with aerosol, 5) carrier gas with aerosol and excess lithium. A complete RF power mapping of argon excited states is obtained. The excited states of argon for a typical analytical torch rapidly diffuse towards the center in the higher region of the plasma. The presence of excess lithium makes no significant change in the excited states of argon. The increase in the RF power increases the intensity of argon excited states uniformly across the radial coordinate.

아르곤 가스를 효율적으로 사용하기 위한 GMA 용접 토치 구조 Part 2 : AMAG와 DMAG 공정의 비교 (GMA Torch Configuration for Efficient Use of Argon Gas Part 2 : Comparison between AMAG DMAG Process)

  • 문명철;고성훈;유중돈
    • Journal of Welding and Joining
    • /
    • 제17권6호
    • /
    • pp.46-52
    • /
    • 1999
  • The auxiliary gas-shielded MAG (AMAG) process, which was devised to provide an argon-rich shielding environment using small amount of argon gas, was investigated experimentally to figure out its effects on metal transfer and weld quality. Proper conditions for the AMAG process including the argon gas ratio, position and direction of the auxiliary nozzle were determined experimentally. Performance of the AMAG process was compared with that of the double gas-shielded MAG(DMAG) and MAG processes by monitoring the bead profile, current and voltage waveforms. The AMAG process was found to provide better bead profile, more stable arc and wider operating range of spray transfer mode compared with the DMAG process. In general, performance of the AMAG process using the argon ratio of 30% was comparable to that of the MAG process using 80% argon and 20% CO₂ gas.

  • PDF

Argon gas 병용처리가 신선편이 감자의 품질에 미치는 영향 (Effects of combined argon gas treatment on the quality of fresh-cut potatoes)

  • 손현주;문광덕
    • 한국식품저장유통학회지
    • /
    • 제21권2호
    • /
    • pp.163-169
    • /
    • 2014
  • 본 연구에서는 argon 가스포장과 기존의 갈변저해물질 중 그 효과가 입증된 ascorbic acid와 저온 blanching 처리 등의 병용처리를 통해 신선편이 감자의 저장 중 품질에 미치는 효과에 대하여 조사하였다. 감자는 박피 후 cube 형태($1.5{\times}1.5{\times}1.5$ cm)로 절단하여 증류수에 1분간 세척 후 물기를 제거하여 argon 가스포장(AR), 1% ascorbic acid에 1분간 침지(AA), 1% ascorbic acid에 1분간 침지 후 argon 가스포장(AAR), $35^{\circ}C$에서 30분간 blanching처리(BA), $35^{\circ}C$ 에서 30분간 blanching처리 후 argon 가스포장(BAR), 아무 처리도 하지 않은 것을 대조구(Cont)로 하여 OPP film에 열접합 포장 후 $5^{\circ}C$에 저장하였다. Cont, AA, BA구의 $O_2$ 농도는 저장기간이 지남에 따라 감소하였으나, argon 가스 포장처리구인 AR, AAR, BAR구에서 $O_2$ 농도는 저장기간이 지남에 따라 조금씩 증가하였다. $CO_2$ 농도는 저장기간이 지남에 따라 모두 증가하였다. 색도 분석 결과 argon 가스포장한 AR, AAR, BAR구에서 Cont, AA, BL구에 비해 높은 $L^*$값과 낮은 갈변도 값을 나타내었으며, 총균수를 분석한 결과 Cont구에서 눈에 띄게 높은 총균수를 나타내었고, argon 가스포장처리구인 AR, AAR, BAR구에서 AA, BL구보다 비교적 낮은 총균수를 나타내어 argon 가스포장이 항갈변 뿐만 아니라 호기성미생물의 생육 저해에 효과가 있음을 알 수 있었다. Polyphenol oxidase(PPO) 활성은 Cont 구에서 눈에 띄게 높은 PPO 활성을 나타내었고 AR처리구에서 가장 낮은 PPO 활성을 나타내었다. DPPH 라디칼 소거능을 이용하여 항산화 활성을 분석해 본 결과 AA, AAR구에서 눈에 띄게 높은 항산화 활성을 나타내었으며, 나머지 구간에는 큰 차이가 없었다. 따라서 argon 가스포장과 병용처리는 신선편이 감자의 갈변 저해, PPO 활성 저해, 항균 효과 등 품질저하를 방지하는데 효과가 있는 것으로 사료된다.

Titanium nitride thin films for applications in thin film resistors

  • Cuong, Nguyen Duy;Kim, Dong-Jin;Kang, Byoung-Don;Yoon, Soon-Gil
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.283-283
    • /
    • 2007
  • Titanium nitride thin films were deposited on $SiO_2$/Si substrate by rf-reactive magnetron sputtering. The structural and electrical properties of the films were investigated with various $N_2/(Ar+N_2)$ flow ratios (nitrogen/argon flow ratio). The resistivity as well as temperature coefficient of resistance (TCR) of the films strongly depends on phase structure. For the films deposited at nitrogen/argon flow ratio of below 5%, the resistivity increased with increasing nitrogen/argon flow ratios. However, the resistivity of the film deposited at nitrogen/argon flow ratio of 7% decreased drastically; it is even smaller than that of metal titanium nitride. A near-zero TCR value of approximately 9 ppm/K was observed for films deposited at nitrogen/argon flow ratio of 3%.

  • PDF

아르곤 레이저를 이용한 광중합 수복재의 물리적 성질에 관한 연구 (A STUDY ON THE PHYSICAL PROPERTIES OF RESTORATIVE MATERIALS FOR PHOTO-POLYMERIZATION OF ARGON LASER)

  • 주상호;최형준;김성오;이종갑
    • 대한소아치과학회지
    • /
    • 제25권2호
    • /
    • pp.368-382
    • /
    • 1998
  • The purpose of this study is to evaluate and compare the results of argon laser for 5 seconds, argon laser for 10 seconds, and visible light for 40 seconds photo-polymerization in compressive strength, microhardness, curing depth, temperature rising during polymerization, and polymerization shrinkage. Hybrid type composite resin(Z-100) and compomer(Dyract) were used to be compared. The compressive strength was measured by an Instron(1mm/min cross head speed) in 60 specimens and the microhardness of the surface was expressed by Vickers Hardness Number(VHN) in 30 specimens. The curing depth was evaluated comparing the different values of upper and lower VHN according to irradiation time and thickness for the light source polymerization in 60 specimens. The temperature rising during photopolymerization was observed by the temperature change with thermocouple sensitizer beneath 40 specimens at the argon laser for 10 seconds and visible light 40 seconds irradiation. The polymerization shinkage was evaluated by calculating the decrease of % volume by using a dilatometer in 30 specimens. The results were as follows ; 1. In the case of compressive strength, the argon laser polymerization groups were higher than visible light group in Z-100 (p<0.05). In Dyract, the argon laser 5 seconds group did not show a significant difference with the visible light 40 seconds group. The argon laser 10 seconds group showed the markedly low value when compared with other groups (p<0.05) 2. In microhardness, Z-100 was better than Dyract when comparing by VHNs (p<0.05); however, there was not a significant difference between two materials in the visible light 40 seconds group and the argon laser 10 seconds group. 3. In the study of curing depth, Z-100 showed the consistent polymerization in argon laser irradiation because there was no difference in the VHN decrease according to the thickness change. Over the thickness control, the results did not show a significant difference between visible light and argon laser group in Z-100; however, in the case of Dyract, the visible light 40 seconds group was better than the argon laser groups(p<0.05). 4. There was a significant difference between the two materials in temperature rising during polymerization (p<0.05), but not a significant difference between irradiation times, 5. There was not a significant difference between the two materials in polymerization shrink age. The argon laser 5 seconds group was smaller than the other groups (p<0.05). It could be concluded that Z-100 polymerization was recommended to use the argon laser for reduction of the irradiation time while Dyract was recommended to use the visible light polymerization.

  • PDF

경남소재 일개조선소 근로자의 건강이상소견과 아르곤 용접과의 관련성 (Association between Subjective Distress Symptoms and Argon Welding among Shipyard Workers in Gyeongnam Province)

  • 최우호;진성미;권덕헌;김장락;강윤식;정백근;박기수;황영실;홍대용
    • 한국산업보건학회지
    • /
    • 제24권4호
    • /
    • pp.547-555
    • /
    • 2014
  • Objective: This study was conducted to investigate the association between subjective distress symptoms and argon welding among workers in Gyeongnam Province shipyard. Method: 31 argon and 29 non-argon welding workers were selected as study subjects in order to measure concentrations of personal dust, welding fumes and other hazardous materials such as ZnO, Pb, Cr, FeO, MnO, Cu, Ni, $TiO_2$, MgO, NO, $NO_2$, $O_3$, $O_2$, $CO_2$, CO and Ar. An interviewer-administered questionnaire survey was also performed on the same subjects. The items queried were as follows: age, height, weight, working duration, welding time, welding rod amounts used, drinking, smoking, and rate of subjective distress symptoms including headache and other symptoms such as fever, vomiting and nausea, metal fume fever, dizziness, tingling sensations, difficulty in breathing, memory loss, sleep disorders, emotional disturbance, hearing loss, hand tremors, visual impairment, neural abnormality, allergic reaction, runny nose and stuffiness, rhinitis, and suffocation. Statistical analysis was performed using SPSS software, version 18. Data are expressed as the mean ${\pm}SD$. An ${\chi}^2$-test and a normality test using a Shapiro wilk test were performed for the above variables. Logistic regression analysis was also conducted to identify the factors that affect the total score for subjective distress symptoms. Result: An association was shown between welding type (argon or non-argon welding) and the total score for subjective distress symptoms. Among the rate of complaining of subjective distress symptoms, vomiting and nausea, difficulty breathing, and allergic reactions were all significantly higher in the argon welding group. Only the concentration of dust and welding fumes was shown to be distributed normally after natural log transformation. According to logistic regression analysis, the correlations of working duration and welding type (argon or non-argon) between the total score of subjective distress symptoms were found to be statistically significant (p=0.041, p=0.049, respectively). Conclusion: Our results suggest that argon welding could cause subjective distress symptoms in shipyard workers.

제2고조파 Argon Laser를 이용한 여러 가지 광섬유 격자의 제작 (Fabrication of Various Fiber Bragg Gratings Using the UV-Argon Laser)

  • 김승우;권재중;김성철;이병호
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 1999년도 추계종합학술대회 논문집
    • /
    • pp.309-312
    • /
    • 1999
  • Fiber Bragg gratings have many applications such as fiber sensors, band-stop filters, add-drop filters, and mode convertors. In this paper, we present the fabrication method of various fiber Bragg gratings by using continuous wave UV-Argon(frequency-doubled Argon) laser. In our experiments, hydrogenation of fibers was used to enhance photosensitivity of fiber. And we fabricated fiber gratings by the phase mask method.

  • PDF

아르곤 레이저의 소아치과에서의 임상적 적용 (CLINICAL APPLICATION OF ARGON LASER IN PEDIATRIC DENTISTRY)

  • 이미나;이상훈;김종철
    • 대한소아치과학회지
    • /
    • 제24권1호
    • /
    • pp.139-147
    • /
    • 1997
  • Argon laser used in this case report, is special in having two wavelength of 488, 514nm blue-green visible light spectrum. Blue light is used for composite resin polymerization and caries detection. Green light is used for soft tissue surgery and coagulation. Maximum absorption of this laser light occurs in red pigmentation such as hemoglobin. The argon laser may be well-suited for selective destruction of blood clots and hemangioma with minimal damage to adjacent tissues. Argon laser light penetrates tissue to the 1 mm depth, so its thermal intensity is lower than $CO_2$ laser light. Also, due to its short wavelength it can be focused in a small spot and even single gene can be excised by this laser and microscopy. After applicating argon laser to 4 patient for surgical procedure and to 1 patient for curing the composite resin, following results were obtained. 1. Improved visibility were gained due to hemostasis and no specific technique were needed according to easy recontouring of the tissue. 2. Ability to use by contact mode, tactile sense was superior but tissue dragability and accumulation of tissue on the tip needed sweeping motion. 3. Additive local anesthetic procedure was needed. 4. No suture and less curing time reduced chair time, this made argon laser available in pediatric dentistry.

  • PDF

치근면 활택술과 아르곤 레이저 사용에 따른 염증성 치은의 교원질 분해효소 검출 비교 (Detection of Collagenase in Inflammatory Gingiva using Root planning and Argon Laser)

  • 이창곤;임성빈;정진형
    • Journal of Periodontal and Implant Science
    • /
    • 제29권3호
    • /
    • pp.577-594
    • /
    • 1999
  • The major cause of periodontal disease is microorganism in the dental plaque. Gingival sulcular fluid, which is exudate released from the tissue near crevicular epithelium is related with inflammation. The purpose of this study was to evaluate the argon laser efficiency between the clinical index and onset of collagenase of gingival sulcular fluid. Material divided 16 patients into 4 groups. The first control was without treatmemt. The second was with just treatment of argon laser, The third was treated by scaling and root planning and the fourth was treated with both scailing and root planning and argon laser. The level of periocheck test, the index of bleeding, and the depth of periodontal pocket were evaluated from for 128 teeth of 64 anterior teeth and 64 posterior teeth. The results were as follows ; 1. In the score of periocheck test, root planing group(group 3) was significantly reduced more than the group without treatment(group 1) and the argon laser treatment(group 2) for results of 3 days and 7 days. But root planing plus argon laser treatment(group 4) in the 7days after experiment, was significantly reduced than no treatment(group 1) and root planing treatment(group 3)(P<0.05), in the 3 days after experiment, was significantly reduced than root planing(group3)(P<0.05). The score of periocheck test to the root planning group(group 3) were significantly reduced between days1, day3 and day7(P<0.05). Root planning plus argon laser group(group 4) were significantly reduced to 1 or 7days and 3 or 7days(P<0.05). The argon laser group(group 2) didn't show any changes. 2. In the case of sulcus bleeding index, the root planning group(group 3) and root planning plus argon laser group(group 4) were reduced more than without treatment group(group 1)(P<0.05) and sulcus bleeding index in the root planning group(group 3) were reduced more than the argon laser group(group 2)(P<0.05). 3. There wasn't any changes of pocket depth between the control and the experiment group as with experiment periods also.

  • PDF

Characteristics of tantalum nitride thin film resistors deposited on $SiO_2/Si$ substrate using D.C-magnetron sputtering

  • Cuong, Nguyen Duy;Phuong, Nguyen Mai;Kim, Dong-Jin;Kang, Byoung-Don;Kim, Chang-Soo;Yoon, Soon-Gil
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.64-65
    • /
    • 2005
  • The structural and electrical properties of the films are investigated as a function of nitrogen/argon ratio at room temperature and at various deposition temperatures. The phase changes as $Ta_2N$ or TaN in the films were observed as nitrogen/argon ratio increases from 3% to 25%. The phase changes were associated with a change in the resistivity and TCR (temperature coefficient of resistance) of the films. TCR values of the films deposited at room temperature and different nitrogen contents were negative, and strongly decreased with the increase in nitrogen/argon ratio. The Ta2N films deposited at nitrogen/argon ratio of 3% show improved TCR values and thermal stability with increasing deposition temperature. The $Ta_2N$ films grown at nitrogen/argon ratio of 3% and the temperature of $200^{\circ}C$ showed a TCR value of -47 $ppm/^{\circ}C$, which is close to near-zero TCR in the range of deposition temperature.

  • PDF