• 제목/요약/키워드: Argon2

Search Result 722, Processing Time 0.033 seconds

Spatial Distribution of Excited Argon Species in and Inductively Coupled Plasma

  • 최범석
    • Bulletin of the Korean Chemical Society
    • /
    • v.19 no.11
    • /
    • pp.1172-1174
    • /
    • 1998
  • Spatial(radial and height) distributions of excited argon species are measured for an inductively coupled plasma under five operating conditions: 1) no carrier gas, 2) carrier gas without aerosol, 3) carrier gas with desolvated aerosol, 4) carrier gas with aerosol, 5) carrier gas with aerosol and excess lithium. A complete RF power mapping of argon excited states is obtained. The excited states of argon for a typical analytical torch rapidly diffuse towards the center in the higher region of the plasma. The presence of excess lithium makes no significant change in the excited states of argon. The increase in the RF power increases the intensity of argon excited states uniformly across the radial coordinate.

GMA Torch Configuration for Efficient Use of Argon Gas Part 2 : Comparison between AMAG DMAG Process (아르곤 가스를 효율적으로 사용하기 위한 GMA 용접 토치 구조 Part 2 : AMAG와 DMAG 공정의 비교)

  • 문명철;고성훈;유중돈
    • Journal of Welding and Joining
    • /
    • v.17 no.6
    • /
    • pp.46-52
    • /
    • 1999
  • The auxiliary gas-shielded MAG (AMAG) process, which was devised to provide an argon-rich shielding environment using small amount of argon gas, was investigated experimentally to figure out its effects on metal transfer and weld quality. Proper conditions for the AMAG process including the argon gas ratio, position and direction of the auxiliary nozzle were determined experimentally. Performance of the AMAG process was compared with that of the double gas-shielded MAG(DMAG) and MAG processes by monitoring the bead profile, current and voltage waveforms. The AMAG process was found to provide better bead profile, more stable arc and wider operating range of spray transfer mode compared with the DMAG process. In general, performance of the AMAG process using the argon ratio of 30% was comparable to that of the MAG process using 80% argon and 20% CO₂ gas.

  • PDF

Effects of combined argon gas treatment on the quality of fresh-cut potatoes (Argon gas 병용처리가 신선편이 감자의 품질에 미치는 영향)

  • Son, Hyun-Ju;Moon, Kwang-Deog
    • Food Science and Preservation
    • /
    • v.21 no.2
    • /
    • pp.163-169
    • /
    • 2014
  • The effect of the combined argon (Ar) gas packaging treatment on the browning of fresh-cut potatoes was studied. Fresh-cut potatoes were prepared for the following six groups: dipping distilled water for 1 minute and air packaging (Cont); dipping in distilled water for 1 minute and argon gas packaging (AR); dipping in 1% ascorbic acid for 1 minute and air packaging (AA); dipping in 1% ascorbic acid for 1 minute and argon gas packaging (AAR); blanching at $35^{\circ}C$ for 30 minutes and air packaging (BL); and blanching at $35^{\circ}C$ for 30 minutes and argon gas packaging (BAR). The potatoes were washed, peeled, and sliced ($1.5{\times}1.5{\times}1.5$ cm) before treatment. The samples were packed with a 0.04-mm-thick OPP film and were stored at $5^{\circ}C$ for 9 days. During the storage, the $O_2$ concentration decreased in Cont but increased in the AR, AA, AAR, BL, and BAR groups. The $CO_2$ concentration increased during storage. The AR, AAR, and BAR groups showed high $L^*$ and low $a^*$, $b^*$ values (browning index). The growth of the total aerobic bacteria was also inhibited in the AR group. During storage, the PPO activity gradually increased, and the AR group showed lower PPO activity. The AA and AAR groups showed high DPPH radical scavenging activity. It was demonstrated that the argon gas packaging is effective in the quality maintenance of fresh-cut potatoes.

Titanium nitride thin films for applications in thin film resistors

  • Cuong, Nguyen Duy;Kim, Dong-Jin;Kang, Byoung-Don;Yoon, Soon-Gil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.06a
    • /
    • pp.283-283
    • /
    • 2007
  • Titanium nitride thin films were deposited on $SiO_2$/Si substrate by rf-reactive magnetron sputtering. The structural and electrical properties of the films were investigated with various $N_2/(Ar+N_2)$ flow ratios (nitrogen/argon flow ratio). The resistivity as well as temperature coefficient of resistance (TCR) of the films strongly depends on phase structure. For the films deposited at nitrogen/argon flow ratio of below 5%, the resistivity increased with increasing nitrogen/argon flow ratios. However, the resistivity of the film deposited at nitrogen/argon flow ratio of 7% decreased drastically; it is even smaller than that of metal titanium nitride. A near-zero TCR value of approximately 9 ppm/K was observed for films deposited at nitrogen/argon flow ratio of 3%.

  • PDF

A STUDY ON THE PHYSICAL PROPERTIES OF RESTORATIVE MATERIALS FOR PHOTO-POLYMERIZATION OF ARGON LASER (아르곤 레이저를 이용한 광중합 수복재의 물리적 성질에 관한 연구)

  • Ju, Sang-Ho;Choi, Hyung-Jun;Kim, Seong-Oh;Lee, Jong-Gap
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.25 no.2
    • /
    • pp.368-382
    • /
    • 1998
  • The purpose of this study is to evaluate and compare the results of argon laser for 5 seconds, argon laser for 10 seconds, and visible light for 40 seconds photo-polymerization in compressive strength, microhardness, curing depth, temperature rising during polymerization, and polymerization shrinkage. Hybrid type composite resin(Z-100) and compomer(Dyract) were used to be compared. The compressive strength was measured by an Instron(1mm/min cross head speed) in 60 specimens and the microhardness of the surface was expressed by Vickers Hardness Number(VHN) in 30 specimens. The curing depth was evaluated comparing the different values of upper and lower VHN according to irradiation time and thickness for the light source polymerization in 60 specimens. The temperature rising during photopolymerization was observed by the temperature change with thermocouple sensitizer beneath 40 specimens at the argon laser for 10 seconds and visible light 40 seconds irradiation. The polymerization shinkage was evaluated by calculating the decrease of % volume by using a dilatometer in 30 specimens. The results were as follows ; 1. In the case of compressive strength, the argon laser polymerization groups were higher than visible light group in Z-100 (p<0.05). In Dyract, the argon laser 5 seconds group did not show a significant difference with the visible light 40 seconds group. The argon laser 10 seconds group showed the markedly low value when compared with other groups (p<0.05) 2. In microhardness, Z-100 was better than Dyract when comparing by VHNs (p<0.05); however, there was not a significant difference between two materials in the visible light 40 seconds group and the argon laser 10 seconds group. 3. In the study of curing depth, Z-100 showed the consistent polymerization in argon laser irradiation because there was no difference in the VHN decrease according to the thickness change. Over the thickness control, the results did not show a significant difference between visible light and argon laser group in Z-100; however, in the case of Dyract, the visible light 40 seconds group was better than the argon laser groups(p<0.05). 4. There was a significant difference between the two materials in temperature rising during polymerization (p<0.05), but not a significant difference between irradiation times, 5. There was not a significant difference between the two materials in polymerization shrink age. The argon laser 5 seconds group was smaller than the other groups (p<0.05). It could be concluded that Z-100 polymerization was recommended to use the argon laser for reduction of the irradiation time while Dyract was recommended to use the visible light polymerization.

  • PDF

Association between Subjective Distress Symptoms and Argon Welding among Shipyard Workers in Gyeongnam Province (경남소재 일개조선소 근로자의 건강이상소견과 아르곤 용접과의 관련성)

  • Choi, Woo-Ho;Jin, Seong-Mi;Kweon, Deok-Heon;Kim, Jang-Rak;Kang, Yune-Sik;Jeong, Baek-Geum;Park, Ki-Soo;Hwang, Young-Sil;Hong, Dae-Yong
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.24 no.4
    • /
    • pp.547-555
    • /
    • 2014
  • Objective: This study was conducted to investigate the association between subjective distress symptoms and argon welding among workers in Gyeongnam Province shipyard. Method: 31 argon and 29 non-argon welding workers were selected as study subjects in order to measure concentrations of personal dust, welding fumes and other hazardous materials such as ZnO, Pb, Cr, FeO, MnO, Cu, Ni, $TiO_2$, MgO, NO, $NO_2$, $O_3$, $O_2$, $CO_2$, CO and Ar. An interviewer-administered questionnaire survey was also performed on the same subjects. The items queried were as follows: age, height, weight, working duration, welding time, welding rod amounts used, drinking, smoking, and rate of subjective distress symptoms including headache and other symptoms such as fever, vomiting and nausea, metal fume fever, dizziness, tingling sensations, difficulty in breathing, memory loss, sleep disorders, emotional disturbance, hearing loss, hand tremors, visual impairment, neural abnormality, allergic reaction, runny nose and stuffiness, rhinitis, and suffocation. Statistical analysis was performed using SPSS software, version 18. Data are expressed as the mean ${\pm}SD$. An ${\chi}^2$-test and a normality test using a Shapiro wilk test were performed for the above variables. Logistic regression analysis was also conducted to identify the factors that affect the total score for subjective distress symptoms. Result: An association was shown between welding type (argon or non-argon welding) and the total score for subjective distress symptoms. Among the rate of complaining of subjective distress symptoms, vomiting and nausea, difficulty breathing, and allergic reactions were all significantly higher in the argon welding group. Only the concentration of dust and welding fumes was shown to be distributed normally after natural log transformation. According to logistic regression analysis, the correlations of working duration and welding type (argon or non-argon) between the total score of subjective distress symptoms were found to be statistically significant (p=0.041, p=0.049, respectively). Conclusion: Our results suggest that argon welding could cause subjective distress symptoms in shipyard workers.

Fabrication of Various Fiber Bragg Gratings Using the UV-Argon Laser (제2고조파 Argon Laser를 이용한 여러 가지 광섬유 격자의 제작)

  • 김승우;권재중;김성철;이병호
    • Proceedings of the IEEK Conference
    • /
    • 1999.11a
    • /
    • pp.309-312
    • /
    • 1999
  • Fiber Bragg gratings have many applications such as fiber sensors, band-stop filters, add-drop filters, and mode convertors. In this paper, we present the fabrication method of various fiber Bragg gratings by using continuous wave UV-Argon(frequency-doubled Argon) laser. In our experiments, hydrogenation of fibers was used to enhance photosensitivity of fiber. And we fabricated fiber gratings by the phase mask method.

  • PDF

CLINICAL APPLICATION OF ARGON LASER IN PEDIATRIC DENTISTRY (아르곤 레이저의 소아치과에서의 임상적 적용)

  • Lee, Mi-Na;Lee, Sang-Hoon;Kim, Chong-Chul
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.24 no.1
    • /
    • pp.139-147
    • /
    • 1997
  • Argon laser used in this case report, is special in having two wavelength of 488, 514nm blue-green visible light spectrum. Blue light is used for composite resin polymerization and caries detection. Green light is used for soft tissue surgery and coagulation. Maximum absorption of this laser light occurs in red pigmentation such as hemoglobin. The argon laser may be well-suited for selective destruction of blood clots and hemangioma with minimal damage to adjacent tissues. Argon laser light penetrates tissue to the 1 mm depth, so its thermal intensity is lower than $CO_2$ laser light. Also, due to its short wavelength it can be focused in a small spot and even single gene can be excised by this laser and microscopy. After applicating argon laser to 4 patient for surgical procedure and to 1 patient for curing the composite resin, following results were obtained. 1. Improved visibility were gained due to hemostasis and no specific technique were needed according to easy recontouring of the tissue. 2. Ability to use by contact mode, tactile sense was superior but tissue dragability and accumulation of tissue on the tip needed sweeping motion. 3. Additive local anesthetic procedure was needed. 4. No suture and less curing time reduced chair time, this made argon laser available in pediatric dentistry.

  • PDF

Detection of Collagenase in Inflammatory Gingiva using Root planning and Argon Laser (치근면 활택술과 아르곤 레이저 사용에 따른 염증성 치은의 교원질 분해효소 검출 비교)

  • Lee, Chang-Gon;Lim, Sung-Bin;Chung, Chin-Hyung
    • Journal of Periodontal and Implant Science
    • /
    • v.29 no.3
    • /
    • pp.577-594
    • /
    • 1999
  • The major cause of periodontal disease is microorganism in the dental plaque. Gingival sulcular fluid, which is exudate released from the tissue near crevicular epithelium is related with inflammation. The purpose of this study was to evaluate the argon laser efficiency between the clinical index and onset of collagenase of gingival sulcular fluid. Material divided 16 patients into 4 groups. The first control was without treatmemt. The second was with just treatment of argon laser, The third was treated by scaling and root planning and the fourth was treated with both scailing and root planning and argon laser. The level of periocheck test, the index of bleeding, and the depth of periodontal pocket were evaluated from for 128 teeth of 64 anterior teeth and 64 posterior teeth. The results were as follows ; 1. In the score of periocheck test, root planing group(group 3) was significantly reduced more than the group without treatment(group 1) and the argon laser treatment(group 2) for results of 3 days and 7 days. But root planing plus argon laser treatment(group 4) in the 7days after experiment, was significantly reduced than no treatment(group 1) and root planing treatment(group 3)(P<0.05), in the 3 days after experiment, was significantly reduced than root planing(group3)(P<0.05). The score of periocheck test to the root planning group(group 3) were significantly reduced between days1, day3 and day7(P<0.05). Root planning plus argon laser group(group 4) were significantly reduced to 1 or 7days and 3 or 7days(P<0.05). The argon laser group(group 2) didn't show any changes. 2. In the case of sulcus bleeding index, the root planning group(group 3) and root planning plus argon laser group(group 4) were reduced more than without treatment group(group 1)(P<0.05) and sulcus bleeding index in the root planning group(group 3) were reduced more than the argon laser group(group 2)(P<0.05). 3. There wasn't any changes of pocket depth between the control and the experiment group as with experiment periods also.

  • PDF

Characteristics of tantalum nitride thin film resistors deposited on $SiO_2/Si$ substrate using D.C-magnetron sputtering

  • Cuong, Nguyen Duy;Phuong, Nguyen Mai;Kim, Dong-Jin;Kang, Byoung-Don;Kim, Chang-Soo;Yoon, Soon-Gil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.64-65
    • /
    • 2005
  • The structural and electrical properties of the films are investigated as a function of nitrogen/argon ratio at room temperature and at various deposition temperatures. The phase changes as $Ta_2N$ or TaN in the films were observed as nitrogen/argon ratio increases from 3% to 25%. The phase changes were associated with a change in the resistivity and TCR (temperature coefficient of resistance) of the films. TCR values of the films deposited at room temperature and different nitrogen contents were negative, and strongly decreased with the increase in nitrogen/argon ratio. The Ta2N films deposited at nitrogen/argon ratio of 3% show improved TCR values and thermal stability with increasing deposition temperature. The $Ta_2N$ films grown at nitrogen/argon ratio of 3% and the temperature of $200^{\circ}C$ showed a TCR value of -47 $ppm/^{\circ}C$, which is close to near-zero TCR in the range of deposition temperature.

  • PDF