• Title/Summary/Keyword: Area under curve

Search Result 1,238, Processing Time 0.031 seconds

Comparison of the Imaging Features of Lobular Carcinoma In Situ and Invasive Lobular Carcinoma of the Breast (유방의 소엽상피내암과 침윤성 소엽암의 영상의학적 소견 비교)

  • Ga Young Yoon;Joo Hee Cha;Hak Hee Kim;Min Seo Bang;Hee Jin Lee;Gyungyub Gong
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.5
    • /
    • pp.1231-1245
    • /
    • 2021
  • Purpose To investigate the usefulness of imaging features for differentiating between small lobular carcinoma in situ (LCIS) and invasive lobular carcinoma (ILC). Materials and Methods It included 52 female with LCISs (median 45 years, range 32-67 years) and 180 female with ILCs (median 49 years, range 36-75 years), with the longest diameter of ≤ 2 cm, who were evaluated between January 2012 and December 2016. All the female underwent mammography and ultrasonography. Twenty female with LCIS and 150 female with ILC underwent MRI. The clinical and imaging features were compared, and multivariate analysis was performed to identify the independent predictors of LCIS. Female with LCIS were also sub-grouped by lesion size and compared with the female with ILC. Results Multivariate analysis showed that younger age (odds ratio [OR] = 1.100), smaller lesion size (OR = 1.103), oval or round shape (OR = 4.098), parallel orientation (OR = 5.464), and isoechotexture (OR = 3.360) were significant independent factors predictive of LCIS. The area under the receiver operating characteristic curve for distinguishing LCIS from ILC was 0.904 (95% confidence interval, 0.857-0.951). Subgroup analysis showed that benign features were more prevalent in female with smaller LCISs (≤ 1 cm) than in those with ILC. Conclusion Small LCISs tend to demonstrate more benign features than small ILCs. Several imaging features are independently predictive of LCIS.

National Survey of Injury and Poisoning on a Representative Sample Population of Koreans (우리나라 대표적(代表的) 표본인구(標本人口)의 연간(年間) 손상(損傷) 및 중독발생율(中毒發生率)과 역학적(疫學的) 특성(特性))

  • Kim, Joung-Soon;Kim, Sung-Soo;Chang, Sung-Chill
    • Journal of Preventive Medicine and Public Health
    • /
    • v.27 no.3 s.47
    • /
    • pp.447-463
    • /
    • 1994
  • Despite the public health importance of injury and poisoning in terms of its high mortality and incidence, epidemiologic information to be utilized are scarce in Korea. This study was carried out in 1990 on a representative sample population (about 55,000 persons) along with the 6th National Tuberculosis Prevalence Survey in order to estimate the magnitude of injury and poisoning occurrence and to identify its epidemiologic characteristics which can be aided for establishing preventive strategy. Pre-tested and structured Questionnaire was used by trained interviewer to collect data including general information of the person, various information on the injury and poisoning during the past one year such as time and place of its occurrence, its nature and external causes, type of medical institute attended, duration of treatment and outcome of the accident occured. In analysis of the data collected incidence rates per 1000 persons by sex, age group and its nature as well as external causes, and relative frequencies were calculated. The result obtained are as followings; 1. The incidence rate per 1000 was 30 for both sexes, 39 for male and 22 for female, male being 1.8 times more frequent than female. Age adjusted incidences were not much different from the crude rates. Age group specific rate curve showed bimodal shape in both sexes, small peaks in preschool children and higher peaks in older ages. The incidence rate per 1000 people by area was highest in Jeon-bug province (57/1000) and the lowest in Daegu city(11/1000). 2. The place where the injuries occured were road in 46%, within the boundary of house in 25%, and working place in 12% The injuries and poisoning had occured more frequently during the months from March to August of the year than other months. 3. The relatively frequent injuries by its nature were contusion with intact skin surface (19%), fracture of upper limb (13%), open wound of head, neck and trunk (12%) and fracture of lower limb (11%) among males; contusion with intact skin surface (28%), sprains and strains of joints and adjacent muscle (14%), fracture of upper limb (10%) and fracture of lower limb (9%) among females. Higher incidence rate among males than females were fracture of skull (4.5 times), open wound and fractures of limbs ($2{\sim}3$ times). Age specific rate of injuries and poisoning by its nature showed increasing pattern by age in fractures of upper and lower limbs and sprains & strains of joints whereas the age group of 30's showed highest incidence in open wounds of upper limb. Fractures of radius and ulna in upper limb, fractures of tibia & fibula and ankle in lower limb were most frequent among fractures of upper and lower limbs. The frequent injuries among sprains and strains of joints and adjacent muscles were that of ankle, foot and back, and among open wound were that of head and fingers. 4. Relative frequency of injuries and poisoning by external causes showed following order : other accidents (25%), accidental falls (23%), motor vehicle accident (22%) and other road vehicle accident (14%) among males and accidental falls (37%), motor vehicle accident (24%) and other accident (18%) among females. The external causes revealing higher incidences among males than females, were other road vehicle accident (4.8 times), vehicle accident not elsewhere classifiable (4.4 times), accidental poisoning (4.4 times), accidents due to natural and environmental factors (2.8 times), and sucide & self-inflicted injuries (2.8 times). Age specific incidence by external causes for frequent injuries showed that incidence of other accident steadily increased from 10's till age 50's; motor vehicle traffic accident increased from age 20's and dropped after age 60's; on the other hand accidental fall increased strikingly by age. The most frequent external causes among motor vehicle traffic accidents was motor vehicle traffic accident involving collision with pedstrain (69%), pedal cycle accident (30%) and other road vehicle accident (71%) among other road vehicle accidents; falls on same level from slipping, tripping or standing (44%) and other falls from one level to another among accidental falls; accidents caused by machinary (32%) for male and striking against or struck accidentally by objects or person for female among other accidents. 5. Seventy nine percent of the injuries and poisonings were treated in general hospital or hospital/clinic. The duration of treatment ranged from a few days to 123 weeks; the majority(52%) took under 2 weeks, 36% for $3{\sim}8$ weeks and 4% over 21 weeks. 6. The accident resulted in full recovery of normal healthy state in 62%, residual functional defects in 21% and on process of treatment in 16%.

  • PDF

Effects of Sea Tangle-added Patty on Postprandial Serum Lipid Profiles and Glucose in Borderline Hypercholesterolemic Adults (다시마 첨가 패티가 경계역 고콜레스테롤혈증 성인의 식후 혈청 지질 및 혈당 농도에 미치는 영향)

  • Kim, Hwa Hyun;Lim, Hyeon-Sook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.43 no.4
    • /
    • pp.522-529
    • /
    • 2014
  • Sea tangle (Laminaria japonica) is well known as having anti-diabetic and hypolipidemic effects in animals as well as in humans. In this study, we evaluated the effects of sea tangle-added patty on postprandial blood glucose and lipid profiles in borderline-hypercholesterolemic (cholesterol ${\geq}200$ mg/dL) adults. Eleven subjects voluntarily participated in the experiment, and each subject provided written consent. Experimental patty (E) was made by adding 2.25 g of sea tangle powder as a substitution to 1.125 g each of pork and chicken. In the first week, 200 g of Control patty (C) was provided to each subject, who had fasted more than 12 hours. In the second week, the same amount of E patty was supplied under the same conditions. Serum glucose levels increased significantly less at 30, 60, and 120 min after consumption of E patty compared to the levels at all time points after eating C patty. Thus, the change in the area under curve (${\Delta}AUC$) of serum glucose levels through 120 minutes was lower when consuming E patty compared to C patty. Although serum C-peptide concentrations were not significantly different at all time points between the two patties, the ${\Delta}AUC$ of serum C-peptide concentrations through 120 minutes was lower when consuming E patty compared to C patty. However, there were no differences in serum levels of triglyceride, total cholesterol, LDL-C, and HDL-C at 30, 60, 120, 180, and 240 min between the two patties. Further, each ${\Delta}AUC$ of these lipid levels through 240 minutes was not significantly different between the two patties. The results indicate that sea tangle-added patty may decrease postprandial plasma glucose concentrations and reduce insulin secretion, although it might not ameliorate serum lipid profiles in adults with borderline-hypercholesterolemia.

Implant Isolation Characteristics for 1.25 Gbps Monolithic Integrated Bi-Directional Optoelectronic SoC (1.25 Gbps 단일집적 양방향 광전 SoC를 위한 임플란트 절연 특성 분석)

  • Kim, Sung-Il;Kang, Kwang-Yong;Lee, Hai-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.8
    • /
    • pp.52-59
    • /
    • 2007
  • In this paper, we analyzed and measured implant isolation characteristics for a 1.25 Gbps monolithic integrated hi-directional (M-BiDi) optoelectronic system-on-a-chip, which is a key component to constitute gigabit passive optical networks (PONs) for a fiber-to-the-home (FTTH). Also, we derived an equivalent circuit of the implant structure under various DC bias conditions. The 1.25 Gbps M-BiDi transmit-receive SoC consists of a laser diode with a monitor photodiode as a transmitter and a digital photodiode as a digital data receiver on the same InP wafer According to IEEE 802.3ah and ITU-T G.983.3 standards, a receiver sensitivity of the digital receiver has to satisfy under -24 dBm @ BER=10-12. Therefore, the electrical crosstalk levels have to maintain less than -86 dB from DC to 3 GHz. From analysed and measured results of the implant structure, the M-BiDi SoC with the implant area of 20 mm width and more than 200 mm distance between the laser diode and monitor photodiode, and between the monitor photodiode and digital photodiode, satisfies the electrical crosstalk level. These implant characteristics can be used for the design and fabrication of an optoelectronic SoC design, and expended to a mixed-mode SoC field.

Diagnostic Value of Serum Procalcitonin in Febrile Infants Under 6 Months of Age for the Detection of Bacterial Infections (발열이 있는 6개월 미만의 영아에서 세균성 감염에 대한 procalcitonin의 진단적 가치)

  • Kim, Nam Hyo;Kim, Ji Hee;Lee, Taek Jin
    • Pediatric Infection and Vaccine
    • /
    • v.16 no.2
    • /
    • pp.142-149
    • /
    • 2009
  • Purpose : The aim of this study was to determine the diagnostic value of serum procalcitonin (PCT) compared with that of C-reactive protein (CRP) and the total white blood cell count (WBC) in predicting bacterial infections in febrile infants<6 months of age. Methods : A prospective study was performed with infants <6 months of age who were admitted to the Department of Pediatrics with a fever of uncertain source between July and September 2008. Spinal taps were performed according to clinical symptoms and physical examination. Serum PCT levels were measured using an enzyme-linked fluorescent assay. Results : Seventy-one infants (mean age, 2.62 months) were studied. Twenty-six infants (36.6%) had urinary tract infections (UTIs), and 22 infants (31.0%) had viral meningitis. The remaining infants had acute pharyngitis (n=1), herpangina (n=1), upper respiratory tract infections (n=7), acute bronchiolitis (n=8), acute gastroenteritis (n=4), and bacteremia (n=2). The median WBC and CRP levels were significantly higher in infants with UTIs than in infants with viral meningitis. However, there were no differences in the median PCT levels between the groups (0.14 ng/mL vs. 0.11 ng/mL, P=0.419). The area under the receiver operating characteristic curve was 0.792 (95% CI, 0.65-0.896) for WBC, 0.77 (95% CI, 0.626-0.879) for CRP, and 0.568 (95% CI, 0.417-0.710) for PCT. An elevated WBC count (>11,920/${\mu}L$) and an increased CRP level (>1.06mg/dL) were significant predictors of UTIs based on multiple logistic regression analysis. Conclusion : Serum PCT concentrations should be interpreted with caution in infants <6 months of age with a fever of uncertain source.

  • PDF

Assessment of Parameters Measured with Volumetric Pulmonary Artery Catheter as Predictors of Fluid Responsiveness in Patients with Coronary Artery Occlusive Disease (관상동맥 질환을 가진 환자에서 폐동맥카테터로 측정한 전부하 지표들은 수액부하 반응을 예상할 수 있는가?)

  • Lee, Ji-Yeon;Lee, Jong-Hwa;Shim, Jae-Kwang;Yoo, Kyung-Jong;Hong, Seung-Bum;Kwak, Young-Lan
    • Journal of Chest Surgery
    • /
    • v.41 no.1
    • /
    • pp.41-48
    • /
    • 2008
  • Background: Accurate assessment of the preload and the fluid responsiveness is of great importance for optimizing cardiac output, especially in those patients with coronary artery occlusive disease (CAOD). In this study, we evaluated the relationship between the parameters of preload with the changes in the stroke volume index (SVI) after fluid loading in patients who were undergoing coronary artery bypass grafting (CABG). The purpose of this study was to find the predictors of fluid responsiveness in order to assess the feasibility of using. certain parameters of preload as a guide to fluid therapy. Material and Method: We studied 96 patients who were undergoing CABG. After induction of anesthesia, the hemodynamic parameters were measured before (T1) and 10 min after volume replacement (T2) by an infusion of 6% hydroxyethyl starch 130/0.4 (10 mL/kg) over 20 min. Result: The right ventricular end-diastolic volume index (RVEDVI), as well as the central venous pressure (CVP) and pulmonary capillary wedge pressure (PCWP), failed to demonstrate significant correlation with the changes in the SVI (%). Only the right ventricular ejection fraction (RVEF) measured at T1 showed significant correlation. with the changes of the SVI by linear regression (r=0.272, p=0.017). However, when the area under the curve of receiver operating characteristics (ROC) was evaluated, none of the parameters were over 0.7. The volume-induced increase in the SVI was 10% or greater in 31 patients (responders) and under 10% in 65 patients (non-responders). None of the parameters of preload measured at T1 showed a significant difference between the responders and non-responders, except for the RVEF. Conclusion: The conventional parameters measured with a volumetric pulmonary artery catheter failed to predict the response of SVI following fluid administration in patients suffering with CAOD.

A Study on Change of Suspended Solids by Forest Road Construction(I) -Parallel Watersheds Method- (임도개설(林道開設)에 따른 부유토사량(浮遊土砂量) 변화(變化)(I) -대조유역법(對照流域法)을 중심(中心)으로-)

  • Kim, Kyoung-Jin;Chun, Kun-Woo
    • Journal of Forest and Environmental Science
    • /
    • v.10 no.1
    • /
    • pp.57-65
    • /
    • 1994
  • This study was carried out to clarify the sediment export by measuring suspended solids included in streamflow during the rainy season. The study area is located in Experimental Forests, Kangwon National University, where the forest road is under construction. For this purpose, the forest watershed with construction of forest road was compared with normal forest watershed in amount of rainfall and discharge, suspended solids and discharge, and the amount of rainfall and suspended solids. The results were shown as followings. 1. The relationship of discharge and the amount of rainfall was shown as Table 3 and Fig. 3. The delay time of peak point observed in hydrograph was changed by rainfall intensity and amount of previous rainfall. That is, when there was a rain on 12. Jun(more than 20mm/hour for hours), the peak point began three hours after the rainfall intensity over 20mm/hour, and showed $1514m^3/hour$ in automatic water level recorder. In case of the 8th of Aug.(maximum rainfall intensity: 40mm/hour), the peak point of discharge was $1246m^3/hour$ in the same time with maximum rainfall intensity. And on the 20th of Aug.(the maximum rainfall intensity: 17.2mm/hour), the peak point of discharge was $1245m^3/hour$ two hours after the maximum rainfall intensity. 2. On watershed under forest road construction, the relationship between discharge and suspended solids is that suspended solids was proportionately increased by raising discharge. That is, on the 12th of Jun, the maximum of discharge per hour was $1514m^3/hour$ and 1261mg/l of suspended solids was observed an hour after peak point of discharge. And in case of 8th and 20th Aug., each of peak points is $1246m^3/hour$ and $1245m^3/hour$ by measuring time. The maximums of suspended solids measured within two watersheds were examined in value of 4952mg/l and 472mg/l at the same time. 3. During the rainy season, the concentration of suspended solids was influenced by rainfall intensity and indicated especially curve-regressional increase in case of strong rainfall intensity. In each of watersheds, the maximums of suspended solids were 1261mg/l and 125mg/l, 4952mg/l and 44mg/l, and 472mg/l and 4mg/l by the order of rain(a), (b), and (c). Two watersheds showed a remarkable difference.

  • PDF

Influence of Gating and Attenuation-correction for Diagnostic Performance of Usual Rest/stress Myocardial Perfusion SPECT in Coronary Artery Disease (게이트 방법과 감쇠보정이 심근 관류 SPECT의 관상동맥질환 진단 성능에 미치는 영향)

  • Lee, Dong-Soo;Yeo, Jeong-Seok;So, Young;Cheon, Gi-Jeong;Kim, Kyeong-Min;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.33 no.2
    • /
    • pp.131-142
    • /
    • 1999
  • Purpose: Either gated myocardial perfusion SPECT or attenuation corrected SPECT can be used to improve specificity in the diagnosis of coronary artery disease. We investigated in this study whether gating or attenuation correction improved diagnostic performance of rest/stress perfusion SPECT in patients having intermediate pre-test likelihood of coronary artery disease. Materials and Methods: Sixty-eight patients underwent rest attenuation-corrected T1-20l/dipyridamole stress gated attenuation-corrected Tc-99m -MIBI SPECT using an ADAC vertex camera (M:F=29:39, aged $59{\pm}12$ years, coronary artery stenosis ${\geq}70%$, one vessel: 13, two vessel: 18, three vessel: 8, normal: 29). Using a five-point scale, three physicians graded the post-test likelihood of coronary artery disease for each arterial territory (1:normal, 2: possibly normal, 3:equivocal, 4. possibly abnormal, 5: abnormal). Sensitivity, specificity and area under receiver-operating-characteristic curves were compared for each operator between three methods : (A) non-attenuation-corrected SPECT; (B) gated SPECT added to (A): and (C) attenuation-corrected SPECT added to (B). Results: When grade 3 was used as the criteria for coronary artery disease, no differences in sensitivity and specificity were found between the three methods for each operator. Areas under receiver-operating-characteristic curves for diagnosis of coronary artery disease revealed no differences between each modality (p>0.05). Conclusion: In patients at intermediate risk of coronary artery disease, gated SPECT and attenuation- corrected SPECT did not improve diagnostic performance.

  • PDF

Responses of Plasma IGF-1, IGFBPs and Hepatic GH Receptor to Growth Hormone Releasing Peptides (GHRP)-2 Administration and Energy Level in Wethers (거세면양에 있어서 에너지수준에 GHRP-2의 투여가 혈장 IGF-1, IGFBPs 및 hepatic GH 수용체에 미치는 반응)

  • Lee, Hong-Gu;Jin, Young-Cheng;Hidari, Hisashi;Choi, Yun-Jaie;Kim, Seon-Ku;Shin, Teak-Soon;Cho, Byung-Uuk;Kim, Yong-Gyun;Kim, Keun-Ki;Son, Hong-Joo;Lee, Sang-Mong;Park, Hyun-Chul;Kang, Han-Seok
    • Journal of Life Science
    • /
    • v.18 no.7
    • /
    • pp.931-939
    • /
    • 2008
  • The purpose of this study was to determine the effect of energy supplement on responses of plasma insulin-like growth factor (IGF)-1 and IGF binding proteins (IGFBPs) to growth hormone-releasing peptide-2 (GHRP-2) administration in normal protein-fed wethers, and to observe the effect of GHRP-2 treatment on hepatic growth hormone (GH) receptor in well-fed wethers. Plasma IGF-1 and 39-42 kDa IGFBP-3 during the HENP (CP, crude protein 0.34 and TDN, total digestible nutrients 1.83 kg/day DM, dry matter intake) treatment period were higher than in the LENP (CP 0.32 kg and TDN 0.87 kg/day DM intake) period (P<0.05). The response of GH was stimulated by GHRP-2 ($12.5\;{\mu}g/kg$ body weight/day) administration during both of the feed treatment periods (P<0.05). The area under curve (AUC) increment and average concentration of GH (0-180 min) with GHRP-2 administration was higher during HENP treatment than LENP treatment (P<0.01). During the HENP treatment period from day 1 to day 7 of twice daily GHRP-2 treatment, the plasma IGF-1 increment was increased on days 2, 6 and 7 of GHRP-2 administration (P<0.05). On the basis of ligand blotting, the proportions of plasma 39-43 kDa IGFBP-3 during the HENP treatment period only showed a significant difference on days 6 and 7 with GHRP-2 administration. No significant difference in the specific binding of $^{125}I-labeled$ oGH to hepatic membranes was detected between the saline and GHRP-2 treatments of the HENP-fed wethers. These results suggest that the nutritional balance between energy and protein may affect the endogenous GH / IGF-1 axis as well as plasma IGFBP-3 levels.

Design and Dose Distribution of Docking Applicator for an Intraoperative Radiation Therapy (수술중 방사선치료를 위한 조립형 조사기구의 제작과 선량 분포)

  • Chu, Sung-Sil;Kim, Gwi-Eon;Loh, John-Kyu
    • Radiation Oncology Journal
    • /
    • v.9 no.1
    • /
    • pp.123-130
    • /
    • 1991
  • A docking intraoperative electron beam applicator system, which is easily docking in the collimator for a linear accelerator after setting a sterilized transparent cone on the tumor bearing area in the operation room, has been designed to optimize dose distribution and to improve the efficiency of radiation treatment method with linear accelerator. This applicator system consisted of collimator holder with shielded metals and docking cone with transparent acrylic cylinder, A number of technical innovations have been used in the design of this system, this dooking cone gives a improving latral dose coverage at therapeutic volume. The position of $90\%$ isodose curve under suface of 8 cm diameter cone was extended $4\sim7$ mm at 12 MeV electron and the isodose measurements beneath the cone wall showed hot spots as great as $106\%$ for acrylic cone. The leakage radiation dose to tissues outside the cone wall was reduced as $3\sim5\%$ of output dose. A comprehensive set of dosimetric characteristics of the intraoperative radiation therapy applicator system is presented.

  • PDF