• Title/Summary/Keyword: Area standards

Search Result 1,551, Processing Time 0.031 seconds

Crystallographical Characteristics of Solar Salts Produced from Jeonnam Area by X-Ray Diffraction Technique (X선 회절법에 의한 전남지역 천일염의 결정학적 특성)

  • Jeong, Byung-Jo;Kim, Yong;Kim, Chang-Dae;Hyun, Seung-Cheol;Ham, Gyung-Sik
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.38 no.9
    • /
    • pp.1284-1288
    • /
    • 2009
  • Identification of various inorganic compound crystals contained in solar salts, which are produced from 12 areas of Jeonnam, was firstly made by the X-ray diffraction (XRD) technique. The analysis of the XRD spectra was carried out on the basis of Joint Committee on Powder Diffraction Standards (JCPDS) data and the results of Energy Dispersive X-ray Spectrometer (EDX) measurements. In particular, the analysis of the XRD spectra supported that each solar salt contains $Na_2S$ (Shinan Jeungdo and Sinui), $KMgCl_3$ (Shinan Bigeum), $Ca(ClO_3)_2$ (Shinan Docho), $CaAl_4O_7$ (Haenam Songji), $CaSiO_3$ and $CaCl_2$ (Goheung) as inorganic compound crystals, which have not been reported for the solar salts. Also, the XRD results indicated that the solar salts maintain a cubic NaCl crystal structure without any change of lattice parameters etc. However, it was shown in the Field Emission Scanning Electron Microscope (FE-SEM) images that an external form of the solar salts has a lamination layer shape of a cubic structure, which is different from a simple cubic form for the purified salts and the reagent NaCl.

Comparison of F-18 FDG Radioacitivity to Determine Accurate Dose Calibrator Activity Measurements (방사능 측정기를 이용한 F-18 FDG 방사능의 비교)

  • Jin, Gye-Hwan;Kweon, Dae-Cheol;Oh, Ki-Baek;Park, Hoon-Hee;Kim, Jung-Yul;Park, Min-Soo;Park, Dae-Sung
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.159-166
    • /
    • 2009
  • Obviously, the administration of the prescribed amount of activity to the patient requires proper operation of the dose calibrator, which shall be verified by implementing the required quality control on the instrument. This investigation examined the accuracy and precision of dose calibrator activity measurement of the radiopharmaceutical F-18 FDG. To investigate the status of the nuclear medicine centers in Korea for the performance of dose calibrators, 10 centers providing PET/CT system services in Korea were inspected in 2008. We measured accuracy and precision in 10 equipments in consideration of PET/CT model, installation area, and installation time. According to the results of comparative analysis of 10 dose calibrators used to measure radioactivity of F-18 FDG, accuracy was -5.00~4.50% and precision was 0.05~0.45%, satisfying the international standards, which are accuracy ${\pm}$10% and precision ${\pm}$5%. This study demonstrated that, for accurate measurements, no adjustment is necessary for a dose calibrator setting when measuring different dose calibrators of F-18 FDG activity prescriptions.

  • PDF

Acute Pulmonary Toxicity and Body Distribution of Inhaled Metallic Silver Nanoparticles

  • Kwon, Jung-Taek;Minai-Tehrani, Arash;Hwang, Soon-Kyung;Kim, Ji-Eun;Shin, Ji-Young;Yu, Kyeong-Nam;Chang, Seung-Hee;Kim, Dae-Seong;Kwon, Yong-Taek;Choi, In-Ja;Cheong, Yun-Hee;Kim, Jun-Sung;Cho, Myung-Haing
    • Toxicological Research
    • /
    • v.28 no.1
    • /
    • pp.25-31
    • /
    • 2012
  • The purpose of this study was to determine the acute pulmonary toxicity of metallic silver nanoparticles (MSNPs, 20.30 nm in diameter). Acute pulmonary toxicity and body distribution of inhaled MSNPs in mice were evaluated using a nose-only exposure chamber (NOEC) system. Bronchoalveolar lavage (BAL) fluid analysis, Western blotting, histopathological changes, and silver burdens in various organs were determined in mice. Mice were exposed to MSNPs for 6 hrs. The mean concentration, total surface area, volume and mass concentrations in the NOEC were maintained at $1.93{\times}10^7$ particles/$cm^3$, $1.09{\times}10^{10}\;nm^2/cm^3$, $2.72{\times}10^{11}\;nm^3/cm^3$, and 2854.62 ${\mu}g/m^3$, respectively. Inhalation of MSPNs caused mild pulmonary toxicity with distribution of silver in various organs but the silver burdens decreased rapidly at 24-hrs post-exposure in the lung. Furthermore, inhaled MSNPs induced activation of mitogen-activated protein kinase (MAPK) signaling in the lung. In summary, single inhaled MSNPs caused mild pulmonary toxicity, which was associated with activated MAPK signaling. Taken together, our results suggest that the inhalation toxicity of MSNPs should be carefully considered at the molecular level.

Ecological Impact Analysis of a Stream on the Dam Construction Using Species Biotic Index (SBI) as a Tool of Ecosystem Health Assessment

  • An, Kwang-Guk;Kim, Jai-Ku
    • Korean Journal of Ecology and Environment
    • /
    • v.40 no.4
    • /
    • pp.495-502
    • /
    • 2007
  • Species biotic index (SBI), based on a fish assemblage, was applied to a stream assessment using long-term ecological fish data set (1996 to 2001) in Boryong dam area, which is located in the mainstream of Ungchun Stream of Chungnam province, Korea. According to the methods of Hilsenhoff (1988), the scores of tolerance guild assigned 10 classes to each species by its habitat and feeding guild, but modified current 7 criteria to 5 scoring standards due to unclear borderline among species. Relative abundance in the species number of upper stream guilds was only 7% of the total, whereas the abundance in the species number of middle to downstream upper stream guilds was 64%. Mean SBI, based on dataset in Site 1 during 1995-2001 averaged 5.10, which was judged as a "good" condition by the rank criteria of SBI. Before the dam construction, mean SBI in the Site 1 was 4.61, indicating a "good" condition, but after the dam construction, mean SBI was 5.60, indicating a "fair" condition. Trajectory analysis in the Site 1 showed significantly (One-way ANOVA, $F_{6,21}=3.26$, p=0.02) different among years, reflecting the changes of fish composition and population density by the dam construction, whereas Site 2 showed no significant changes ($F_{6,21}=1.00$, P =0.45) difference among years. Mean SBI prior to the dam construction in the Site 3 was 4.52 but after the construction, the value was 6.30, indicating a distinct difference between the pre- and post-dam construction. Trajectory analysis at the Site 3 supported this fact: Values of SBI showed significantly ($F_{6,21}$=14.37, p<0.01) different. Mean SBI was 4.67 in the Site 4, indicating a "good" condition in the health and the health rank was same as the sampling sites 1, 2, and 4. Trajectory in the Site 4 showed no significant ($F_{6,21}=2.35$, p=0.07) difference among the years. Overall, our trajectory analysis indicated that three of four sampling sites (sites 1, 3, 4) showed significant decreases (n=7, p<0.05) and that the proportions of sensitive species declined evidently in the sites 1 and 2 and the tolerant species increased in the dam sites. Our outcomes may be used as a key data for diagnosis of the long-term ecological impact in the future in the watershed.

A Study on the Selection of Target Ship for the Protection of Submarine Power Cable (해저 동력케이블 보호를 위한 대상 선박 선정에 관한 연구)

  • Lee, Yun-sok;Kim, Seungyeon;Yu, Yungung;Yun, Gwi-ho
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.6
    • /
    • pp.662-669
    • /
    • 2018
  • Recently, the installation of submarine power cables is under consideration due to the increase of electric power usage and the development of the offshore wind farm in island areas, including Jeju. In order to protect power cables installed on the seabed, it is necessary to calculate the burial depth based on the characteristics of anchoring, dragging and fishing, etc. However, there is no design standard related to the size of target ships to protect the cables in Korea. In this study, we analyzed the design standards for the protection of domestic submarine pipelines similar to submarine cables, and developed the risk matrix based on the classification by emergency anchoring considering the installation environment, then designed the size of target ships according to the cumulative function scale by ship size sailing through the sea concerned. Also, we linked marine accident conditions, such as anchoring, dragging, etc. and the environmental conditions such as current, sea-area depth of installation etc. to the criteria of the protection of submarine cable, and examined the size of specific target ships by dividing the operating environment of ships into harbor, coastal and short sea. To confirm the adequacy and availability of the size of target ships, we verified this result by applying to No. 3 submarine power cables, which is to be installed in the section from Wando to Jeju Island. This result is expected to influence in the development of a protection system for submarine cables and pipelines as well as the selection of anchor weight according to the determination of burial depth.

A study on the validation of learning goals of community dental hygiene practicum based on the community dental hygiene process of care (지역사회 치위생관리과정에 기반한 지역사회치위생학 실습 학습목표 타당화 연구)

  • Yoo, Sang-Hee;Bae, Soo-Myoung;Shin, Bo-Mi;Shin, Sun-Jung
    • Journal of Korean society of Dental Hygiene
    • /
    • v.20 no.2
    • /
    • pp.139-153
    • /
    • 2020
  • Objectives: The purpose of this study was to define the concept of the community dental hygiene process of care and to develop competency-based learning goals applying the community dental hygiene process of care. Methods: Based on 12 references, the concept of community dental hygiene process of care was defined, and 393 learning objectives were derived to carry out the first and second categorization process. The 57 learning goals were classified according to the 15-week learning subject (once a week) for project learning. To evaluate the validity of the developed learning subjects and goals, 80 community dental hygiene professors were surveyed. The final learning subjects and goals were created by going through the process of collecting opinions from the 35 validity evaluation results received as responses, and opinions from 10 community dental hygiene professors. Results: The first and second validity surveys on the operational definition of community dental hygiene process of care showed 4.32 points and 4.60 points, respectively. As a result of the evaluation of the validity of the learning subjects and goals for 1~15 weeks, the average validity of the learning subjects was 4.44 points, and of learning goals was 4.32 points. Conclusions: The learning subjects and goals developed by applying the theoretical framework for community dental hygiene process of care defined in this study can be used as a learning guideline for learners to understand the theory of community dental hygiene area and to derive the standards of competence in the field of practice.

A Design of Transceiver for 13.56MHz RFID Reader using the Peak Detector with Automatic Reference Voltage Generator (자동 기준전압 생성 피크 검출기를 이용한 13.56 MHz RFID 리더기용 송수신기 설계)

  • Kim, Ju-Seong;Min, Kyung-Jik;Nam, Chul;Hurh, Djyoung;Lee, Kang-Yun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.47 no.3
    • /
    • pp.28-34
    • /
    • 2010
  • In this paper, the transceiver for RFID reader using 13.56MHz as a carrier frequency and meeting International Standard ISO 14443 type A, 14443 type B and 15693 is presented. The receiver is composed of envelope detector, VGA(Variable Gain Amplifier), filter, comparator to recovery the received signal. The proposed automatic reference voltage generator, positive peak detector, negative peak detector, and data slicer circuit can adjust the decision level of reference voltage over the received signal amplitudes. The transmitter is designed to drive high voltage and current to meet the 15693 specification. By using inductor loading circuit which can swing more than power supply and drive large current even under low impedance condition, it can control modulation rate from 30 percent to 5 percent, 100 perccnt and drive the output currents from 5 mA to 240 mA depending on standards. The 13.56 MHZ RFID reader is implemented in $0.18\;{\mu}m$ CM08 technology at 3.3V single supply. The chip area excluding pads is $1.5mm\;{\times}\;1.5mm$.

Estimation of Environmental Performance in 29 Chinese Provinces - Focused on Integrated Pollution Intensity - (중국 29개 성의 환경성과 평가 - 통합오염원 단위를 중심으로 -)

  • Kim, Kwang-Uk;Piao, Huilan-Lan;Kang, Sang-Mok
    • Journal of Environmental Policy
    • /
    • v.10 no.1
    • /
    • pp.71-91
    • /
    • 2011
  • The purpose of this paper is to estimate the environmental performance of 29 Chinese provinces by adopting the advanced measurements, integrated pollution intensity index, IPI, which can be computed using Data Envelopment Analysis(DEA) techniques. This index has the advantage of accounting for multiple resources used, good outputs produced and pollutants emitted simultaneously. The result obtained using the methodology shows the obvious evidence that provinces located around eastern area of China take relatively low levels and these phenomenons have been clearly observed throughout the sample period 1998~2007. The estimated index can be interpreted that the environmental burden in China has been steadily decreased as economic growth. This paper also tries to figure out the relationship among IPI, income levels, economic structures, the level of environmental regulations and FDI inflow. The estimated relationship between IPI and income per capita predicts improving environmental performance with increasing income levels. This explains the improvement in IPI which is simultaneously observed with income increases. According to the 'pollution haven hypothesis', many researches have been concerned the possibility that a large amount of foreign capital has been invested in China to avoid the strict environmental standards in advanced countries. However, the estimated coefficients in all model specifications take negative sign with IPI and highly statistical significant. This is a indication that there are positive impacts of foreign investments on IPI by adopting clean and high technologies from advanced countries.

  • PDF

A Study on the Acidity and Ion Balance of Wet Precipitation in Mt. Kyebang Area, Hongcheon (홍천 계방산지역 내 강수의 산성도와 이온 균형성에 관한 연구)

  • Youn, Hee-Jung;Lee, Seung-Woo
    • Journal of Korean Society of Forest Science
    • /
    • v.98 no.6
    • /
    • pp.712-718
    • /
    • 2009
  • To look into the degree of the long distance movement of the air pollution within Mt. Kyebang, Hongcheon, one of the clean regions, major ions, components of collected wet precipitation, were analyzed by using the ion chromatography after measuring pH and electrical conductivity. The quality assurance of chemical composition data was checked by considering the ion balance and electrical conductivity. Also, the pH of precipitation showed in the pH5.0~5.5 range, less than the pH5.6 in which the standards of the acid precipitation. On the whole, the more precipitation got, the less ion concentration became.: It could showed what it influenced on the fluctuation of the precipitation pH according to fluctuation and neutralization of the according materials. In the meantime, as composition ratios of wet deposition, ${SO_4}^{2-}$ and $nss-{SO_4}^{2-}$, ${NH_4}^+$ and $nss-Ca^{2+}$ accounted for high percentage. Especially, as the concentration of ${SO_4}^{2-}$, the artificial pollutant, and $Ca^{2+}$, the soil substance, showed high, Mt. Kyebang, Hongcheon having barely fixed air-pollutants sources was most likely to be influenced by the pollutants moved from long distances.

Experimental Study on Evaluation of Rotational Resistance of Multi-Span Greenhouse Foundations (연동비닐하우스 기초의 회전저항성능 평가에 관한 실험적 연구)

  • Lee, Hyunjee;Shin, Jiuk;Kim, Minsun;Choi, Kisun
    • Journal of the Korean GEO-environmental Society
    • /
    • v.19 no.9
    • /
    • pp.5-12
    • /
    • 2018
  • The foundation of the multi-span greenhouse structures is designed with small shallow concrete foundation considering mainly the vertical load. However, recently, due to an abnormal climate such as strong wind, horizontal load and up-lift load over design strength are applied to the foundation, causing safety problems of the greenhouse foundation. In order to reasonably evaluate the safety of greenhouse foundations, rotational and pullout stiffness expressed by the ground-foundation interaction should be evaluated, which also affects the safety of the upper structural members. In this study, three representative basic foundation types were selected by classifying greenhouse standards in Korea according to the shape, and the horizontal loading tests and theoretical calculation were performed for each foundation type. As a result of the comparison and analysis of the test and calculation, it was found that rotational resistance of the foundation is different according to the ratio of the contact area between the foundation and ground when the conditions of the foundation - ground contact surface and the mechanical properties of the ground are the same.