• Title/Summary/Keyword: Area source

Search Result 3,560, Processing Time 0.031 seconds

Estimation of PM10 Source Contributions on Three Cities in the Metropolitan Area by Using PMF Model (PMF 모델을 이용한 수도권 내 3개 도시에서의 PM10 오염원의 기여도 추정)

  • Lee, Tae-Jung;Huh, Jong-Bae;Yi, Seung-Muk;Kim, Shin-Do;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.25 no.4
    • /
    • pp.275-288
    • /
    • 2009
  • The Korean government strengthened the environmental polices to manage and enhance Metropolitan Area air quality, and also has enforced "Special Act on Seoul Metropolitan Air Quality Improvement (SASMAQI)" issued in Dec. 2004. Recently government expanded the Seoul Metropolitan Air Quality Management District (SMAQMD) to the outskirts satellite cities of Seoul area through the "Revised Law Draft of SASMAQI". The SMAQMD has been alloted the allowable emission loads to the local governments on the basis of the carrying $PM_{10}$ capacity. However, in order to establish the effective air quality control strategy for $PM_{10}$, it is necessary to understand the corresponding sources which have a potential to directly impact ambient $PM_{10}$ concentration. To deal with the situations, many receptor methodologies have been developed to identify the origins of pollutants and to determine the contributions of sources of interests. The objective of this study was to extensively identify $PM_{10}$ sources and to estimate their contributions at the metropolitan area. $PM_{10}$ samples were simultaneously collected at the 3 semi-industrialized local cities in the Seoul metropolitan area such as Hwasung-si, Paju-si, and Icheon-si sites from April 15 to May 31, 2007. The samples collected on the teflon membrane filter by one $PM_{10}$ cyclone sampler were analyzed for trace metals and soluble ions and samples on the quartz fiber filter by another sampler were analyzed for OC and EC. Source apportionment study was then performed by using a positive matrix factorization (PMF) receptor model. A total of 6 sources were identified and their contributions were estimated in each monitoring site. Contribution results on Hwasung, Paju, and Icheon sites were as follows: 33%, 27%, and 27% from soil source, 26%, 26%, and 21% from secondary aerosol source, 11%, 11%, and 12% from biomass burning, 12%, 6%, and 5% from sea salt, 7%, 15%, and 19% from industrial related source, and finally 11%, 15%, and 16% from mobile and oil complex source, respectively. This study provides information on the major sources affecting air quality in the receptor sites and thus it will help to manage the ambient air quality in the metropolitan area by establishing reasonable control strategies, especially for the anthropogenic emission sources.

External cost Forecasting of Virtual Point Source in Suwon Area Using Impact Pathway Analysis - A Comparison of Suwon to Paris - (영향경로해석을 이용한 수원시 가상 점오염원의 외부비용 예측 - 수원시와 파리시 비교분석을 중심으로 -)

  • Jeong, Sang Jin
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.5
    • /
    • pp.291-303
    • /
    • 2005
  • Impact pathway analysis(IPA) is a bottom-up approach to estimates health and environmental risks from emissions of classical pollutants (eg. $PM_{10}$, $SO_2$, $NO_x$ and CO). The model starts from the emission rates of facility, calculates the yearly mean concentrations of pollutants at the ground level using atmospheric dispersion models. After this, proper epidemiological exposure-response functions are applied to determine the impact on the receptors. Finally the methodology can monetise the calculated physical impact on the basis of selected economic evaluation. The aim of this study is to evaluate an external cost of virtual point source in Suwon area using IPA. The results shows minor modification of local input data can make it possible to apply the model to Suwon area.

Comparison between Two 450 mm Multi-Electrode Models

  • Park, Gi-Jeong;Lee, Yun-Seong;Yu, Dae-Ho;Lee, Jin-Won;Jang, Hong-Yeong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.490-490
    • /
    • 2013
  • In semiconductor industry, it is expected that plasma process which use 450 mm source will be used at next generation. However, main obstacle of the large area plasma source is plasma uniformity from it. When electrode is enlarged, field difference between center area and side area reduces the plasma uniformity [1-3]. Therefore we investigate multi-electrode which diminish this field difference.We designed two multi-electrode models. One has two segments and the other has five segments. Each multi-electrode model is connected with two power generator and two matchers. One generator and one matcher is connected with center electrode part. The other one generator and the other one matcher is connected with side electrode part. The ion density is measured at 29 points by using floating harmonic method [4-6]. After measuring the data of each multi-electrode model, we discuss the difference of profile between two models' data.

  • PDF

Study on the Runoff Characteristics of Non-point Source Pollution in Municipal Area Using SWMM Model -A Case Study in Jeonju City (SWMM모델을 이용한 도시지역 비점오염원의 유출특성 연구 -전주시를 대상으로)

  • Paik Do-Hyson;Lim Young-Hwan;Choi Jin-Kyu;Jung Paul-Gene;Kwak Dong-Heui
    • Journal of Environmental Science International
    • /
    • v.14 no.12
    • /
    • pp.1185-1194
    • /
    • 2005
  • The runoff characteristics of non-point source pollutions in the municipal area of Jeonju were investigated and analyzed by using the SWMM (Storm Water Management Model). The flow rates and water qualities of runoff from two types of drainage conduits were measured respectively. One was a conventional combined sewer system and the other was a separated sewer system constructed recently From August to November in 2004, investigations on two rainfall events were performed and flow rate, pH, BOD, COD, SS, T-N and T-P were measured. These data were also used for model calibration. On the basis of the measured data and the simulation results by SWMM, it is reported that $80-90\%$ of pollution load is discharged in the early-stage storm runoff. Therefore, initial 10-30 mm of rainfall should be controlled effectively for the optimal treatment of non-point source pollution in urban area. Also, it was shown that the SWMM model was suitable for the management of non-point source pollution in the urban area and for the analysis of runoff characteristics of pollutant loads.

A Study on the PM2.5 Source Characteristics Affecting the Seoul Area Using a Chemical Mass Balance Receptor Model (수용모델을 이용한 서울지역 미세입자 (PM2.5)에 영향을 미치는 배출원 특성에 관한 연구)

  • Lee Hak Sung;Kang Choong-Min;Kang Byung-Wook;Lee Sang-Kwun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.21 no.3
    • /
    • pp.329-341
    • /
    • 2005
  • The purpose of this study is to study the $PM_{2.5}$ source characteristics affecting the Seoul area using a chemical mass balance (CMB) receptor model. This study was also to evaluate the $PM_{2.5}$ source profiles, which were directly measured and developed. Asian Dust Storm usually occurred in the spring, and very high $PM_{2.5}$ concentrations were observed in the fall among the sampling periods. So the ambient data collected in the spring and fall were evaluated. The CMB model results as well as the $PM_{2.5}$ source profiles were validated using the diagnostic categories, such as: source contribution estimate, t-statistic, R-square, Chi-square, and percent of total mass explained. In the spring months, the magnitude of $PM_{2.5}$ mass contributors was in the following order: Chinese aerosol $(31.7\%)>$ secondary aerosols ($22.3\%$: ammonium sulfate $13.4\%$ and ammonium nitrate $8.9\%)>$ vehicles ($16.1\%$: gasoline vehicle $1.4\%$ and diesel vehicles $14.7\%)>$biomass burning $(15.5\%)>$ geological material $(10.5\%)$. In the fall months, the general trend of the $PM_{2.5}$ mass contributors was the following: biomass burning $(31.1\%)>$ vehicles ($26.9\%$: gasoline vehicle $5.1\%$ and diesel vehicles $21.8\%)>$ secondary aerosols ($23.0\%$: ammonium sulfate $9.1\%$ and ammonium nitrate $13.9\%)>$ Chinese aerosol $(10.7\%)$. The results show that the $PM_{2.5}$ mass in the Seoul area was mainly affected by the Chinese area.

10-bit Source Driver with Resistor-Resistor-String Digital to Analog Converter Using Low Temperature Poly-Si TFTs

  • Kang, Jin-Seong;Kim, Hyun-Wook;Sung, Yoo-Chang;Kwon, Oh-Kyong
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.696-699
    • /
    • 2008
  • A 10-bit source driver using low temperature poly-silicon(LTPS) TFTs is developed. To reduce the DAC area, the DAC structure including two 5-bit resistor-string DACs and analog buffer, which has analog adder is proposed. The source driver is fabricated using LTPS process and its one channel area is $3,200{\mu}m\;{\times}\;260{\mu}m$. The simulated INL and DNL of output voltages are less than 3 LSB and 1 LSB, respectively.

  • PDF

The Development of Air Quality Model Considering Shipping Source in Pusan Region (선박배출 오염물질의 영향을 고려한 부산지역 대기질 모델의 개발)

  • 이화운;김유근;원경미
    • Journal of Environmental Science International
    • /
    • v.8 no.1
    • /
    • pp.135-144
    • /
    • 1999
  • Air quality modeling about coastal urban region such as Pusan shoud be consider shipping source emmited from ships anchoraging and running. It has been proved at our previous studies that the ratios of air pollutants emission amount in coastal area to inland are 12.2% for NO$_2$ and 11.7% for $SO_2$ and the air qualify of coastal urban area consierably counts on ships. Also the dispersion pattern of the all pollutants followed local circulation system in this region. Therefore this study has been developed air quality model which can describe the formation, transport, transformation and deposition processes of air pollutants considering shipping source. Currently, restriction for emission amount of ships does not exist, so our study will be useful to set the omission standard and for devising air quality policy in coastal urban region.

  • PDF

Data Source Management using weight table in u-GIS DSMS

  • Kim, Sang-Ki;Baek, Sung-Ha;Lee, Dong-Wook;Chung, Warn-Il;Kim, Gyoung-Bae;Bae, Hae-Young
    • Journal of Korea Spatial Information System Society
    • /
    • v.11 no.2
    • /
    • pp.27-33
    • /
    • 2009
  • The emergences of GeoSensor and researches about GIS have promoted many researches of u-GIS. The disaster application coupled in the u-GIS can apply to monitor accident area and to prevent spread of accident. The application needs the u-GIS DSMS technique to acquire, to process GeoSensor data and to integrate them with GIS data. The u-GIS DSMS must process big and large-volume data stream such as spatial data and multimedia data. Due to the feature of the data stream, in u-GIS DSMS, query processing can be delayed. Moreover, as increasing the input rate of data in the area generating events, the network traffic is increased. To solve this problem, in this paper we describe TRIGGER ACTION clause in CQ on the u-GIS DSMS environment and proposes data source management. Data source weight table controls GES information and incoming data rate. It controls incoming data rate as increasing weight at GES of disaster area. Consequently, it can contribute query processing rate and accuracy

  • PDF

Quantitative Source Estimation of PM-10 in Seoul Area (서울시 PM-10 오염원의 정량적 기여도 추정)

  • 유정석;김동술;김윤신
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.3
    • /
    • pp.279-290
    • /
    • 1995
  • Recently in Korea, due to the significant drop of lead and bromine levels as a marker of autoemission source in the urban areas, the conventional application of receptor methods has many difficulties to properly apportion mass contribution of some sources. It is then needed to urgently develop alternative source profiles and identify new emission markers. Thus, the study has extensively examined the results obtained from using PAHs and elemental data for receptor modeling and has provided an opportunity to identify alternative source compositions and to determine a proper number of the ambient emission sources in Seoul area. The purpose of the study is to identify the sources of PM-10 and to estimate their mass contributions in Seoul area. Thus, a receptor model, target transformation factor analysis(TTFA) has been massively applied. The TTFA offers the possibility of determining the number of sources and their mass contributions. The input data used in this study are composed of two separate sets: fine (d$_{p}$ < 2.5.mu.m) and coarse (2.5.mu.m < d$_{p}$ < 10.mu.m) mode aerosol samples. Each sample was simultaneously collected by a PM-10 dichotomous sampler during the daytime(8 AM to 8 PM) and the nighttime(8 PM to 8 AM) from February to October 1993 on the Sungdong-Gu, Seoul. All the samples were analyzed to determine the levels of 10 inorganic elements by an XRF system as well as 14 PAHs by a HPLC. However, only 8 inorganic elements and 7 PAHs were used for the various statistical analysis.sis.

  • PDF

Application of SWMM for Management of the Non-point Source in Urban Area -Case Study on the Pohang City- (도시지역 비점오염원 관리를 위한 SWMM의 적용 -포항시를 대상으로-)

  • Lee, Jae-Yong;Jang, Seong-Ho;Park, Jin-Sik
    • Journal of Environmental Health Sciences
    • /
    • v.34 no.3
    • /
    • pp.247-254
    • /
    • 2008
  • Non-point source pollution that originates from surface applied chemicals in either liquid or solid form is a part of urban activities and it appears in the surface runoff caused by rainfall. This study investigates the characteristics of non point source pollution in relation to storm events and the first washing effect in the Study area, which is comprised of different land use types. Then, a Best Management Practices (BMP) model, for urban areas, is applied with the Storm water Management Model (SWMM) Windows Interface which was developed by the EPA in the USA. During the storm event analysis of the hydrographic and pollutographic data showed that the peak of pollutants concentration was within the peak flow, 30 to 60 minute into the storm event in the Study area. The results of simulation using SWMM Windows Interface, Structure Techniques as applied in the study were highly efficient for removal of pollutants. Predicted removal efficiency was 26.0% for SS, 22.1 for BOD, 24.1% for COD, 20.6% for T-N, and 21.6% for T-P, respectively.