• 제목/요약/키워드: Area of evacuation

검색결과 229건 처리시간 0.027초

침수 시 주거용 건축물에서 대피시설로의 접근 취약성 분석을 통한 피난경로 확보방안 - 대구시 북구 침수 사례지를 중심으로 - (Ensuring the Evacuation Path Based on Inundation & Refuge Approach Vulnerability Analysis in Residential Buildings - Focused on Daegu Bukgu Inundation Case District -)

  • 이지수;홍원화;김광섭
    • 한국주거학회논문집
    • /
    • 제23권5호
    • /
    • pp.1-8
    • /
    • 2012
  • Recently, there have been frequent occurrence of the damage to lives and properties due to the torrential rain caused by climate change. In consideration of the current situations in which the underlying data related to flooding are lacking, this study conducted to build up the basic data on the flooded areas and suggested methods to secure the evacuation routes that can be accessible to evacuation facilities in the residential buildings. Methods of the study are as follows. First, We calculated the flood risk grades of residential buildings based on elevations, considering the flooding characteristics of the flooded areas in Buk-gu, Daegu. Second, We constructed baseline data on the evacuation routes through site investigation and reviewed of drawing using Arc GIS to identify vulnerability to access to the evacuation facilities, targeting the residential buildings. Third, We carried out the proximity analysis through a near analysis of analysis functions in ARC GIS. Forth, We deduced 115 residential buildings in which access to evacuation facilities is considered to be difficult based on the analysis results. Finally, We proposed extension of a blind alley as a means for achieving connectivity to evacuation facilities. And to evaluate the alternatives presented, we reconstructed route data. As a result, about 53% improvement was identified through the proximity analysis.

다중이용시설의 피난방화문에 관한 연구 (Study of evacuation fire doors in multiple facilities)

  • 차종호
    • 한국산학기술학회논문지
    • /
    • 제15권12호
    • /
    • pp.7380-7384
    • /
    • 2014
  • 피난방화문이란 기존에 성능을 인정받은 방화문의 전면에 축광도료를 바르고 손잡이 부근에는 시온도료를 발라 제작한 방화문으로 기존에 방화설비로만 사용되었던 방화문에 피난 및 안전 기능을 추가, 방화문 자체가 피난설비로서의 기능을 겸용하는 설비이다. 피난안전방화문의 휘도는 기존의 유도표지 휘도(60분후 7mcd)이상의 성능으로 한국소방산업기술원의 휘도시험을 통과한 설비로, 화재 시 가시성의 면적이 피난구유도등에 비해 크며 연기의 하강에도 방화문 아랫부분의 방광상태가 관찰되어 피난자들의 피난유효 시간을 연장시켜 줄 것으로 사료된다. 손잡이 부근에 발라져 있는 시온도료는 일정온도에 도달하면($70^{\circ}C$) 색상이 변화 위험경고가 방화문 바탕에 나타나게 되어 화재 시 피난자들이 방화문 손잡이에 입을 수 있는 1차 재해를 예방할 수 있으며, 화재공간에 진입을 하여야 하는 소방관들에게는 역화 가능성을 사전에 인지 안전 사고를 예방하는데 도움을 줄 것으로 판단된다.

전국의 대피시설 실태조사를 통한 민방위 대피시설 표준 정립 모델 구축 연구 (A Study on Civil Defense Evacuation Facilities)

  • 박남희;여욱현;김태환
    • 한국재난정보학회 논문집
    • /
    • 제8권1호
    • /
    • pp.56-70
    • /
    • 2012
  • 현재 우리나라에 설치되어 있는 민방위 대피시설을 조사하여 그동안 시설 지정에 치우쳐왔던 민방위 대피시설 운영 실태를 파악할 필요가 있다. 본 연구의 목적은 현 민방위 대피시설에 대한 시설설비, 관리 등의 조사 및 문제점 분석을 통해 민방위대피시설의 실태를 분석하고 이를 바탕으로 민방위대피시설의 표준 정립모델을 구축하는 것이다. 본 연구의 결론은 다음과 같다. 첫째, 민방위 대피시설은 지역별로는 서울에 가장 많이 분포하고 있고, 시설별로는 아파트주차장의 빈도가 가장 높다. 둘째, 민방위 대피시설이 주기적으로 점검을 하고 있는 것으로 나타났으나 시설별 점검회수가 일정하지 않고 체계적인 점검이 이루어지고 있는 것으로 보기 어렵다. 셋째, 유선전화, CCTV, 이동통신설비, 방송설비 등 통신시설이 없는 대피시설이 많은 것으로 나타나 비상 상황시 외부와의 연락에 어려움이 예상된다. 넷째, 종합적으로 보면 현재 수도권 및 대도시 중심으로 2000년 이전에 건축되어 비교적 노후한 대피시설이 많은 것으로 보인다. 정립모델안은 위치, 규모, 수용인원, 인접시설과의 거리, 독립공간 유무, 개구부, 계단, 진입방식, 시설관리, 안내시설, 전기시설, 통신시설, 소방시설, 냉난방시설, 급배수시설, 위생시설 측면에서 필수 사항을 정리하였다.

홍수재난에 대한 최적 대피경로 분석 (Analysis of Optimal Evacuation Route for Flood Disaster)

  • 김경훈;박재우
    • 한국콘텐츠학회논문지
    • /
    • 제18권2호
    • /
    • pp.169-177
    • /
    • 2018
  • 가뭄, 홍수 등의 자연재난으로 인해 인명 손실이 많이 발생되고 있다. 특히 도시지역에 발생되는 집중호우로 인한 침수 피해는 인명 및 구조물에 심각한 피해를 발생시킨다. 이에 따라 본 연구에서는 침수피해가 높은 도시지역을 대상으로 사람들이 안전하게 대피할 수 있도록 하는 최적 대피경로에 관한 연구를 수행하였다. 이를 위해 Flo-2D 모형 및 A*알고리즘에 대하여 고찰하여 최적 대피경로를 도출하고자 하는 방법론을 설정하였다. Flo-2D모형을 통해 위험지역을 도출하였으며, 인원수가 많은 시작지점을 선정하고 홍수재난에 대해 안전한 대피지점을 선정할 수 있도록 하는 방법을 제시하였다. 그리고 A* 알고리즘을 활용하여 출발지점에서 안전한 대피지점까지 위험지점을 거치지 않고 최적의 대피경로를 도출하였다. 본 연구를 통해 대피경로 제시뿐만 아니라 도로정비와 대피시설물에 대한 사전 대비 자료로 활용될 수 있을 것으로 판단된다.

Cube Avenue 시뮬레이션 모델을 이용한 중규모 재난대피 프로토타입 모델 연구 (A Study on Prototype Model for Mesoscopic Evacuation Using Cube Avenue Simulation Model)

  • 신흥권;주용진
    • Spatial Information Research
    • /
    • 제21권5호
    • /
    • pp.33-41
    • /
    • 2013
  • 최근, 각종 자연재해와 산업재해로 인한 피해규모의 증가와 이에 따른 대책 수립의 필요성이 증가하고 있으며 재난 규모 역시 대형화, 거대화됨에 따라 피해규모는 점점 더 심각해지고 있다. 이러한 각종 재난 시 재난대피계획의 핵심은 재난대피에 소요되는 시간추정, 병목지점 파악 등을 포함하며 이러한 재난대피계획의 수립과 평가를 위해서는 적절한 재난대피모델이 필요하다. 또한, 기존 연구가 주로 건축물 실내를 대상으로 재난 시 대피경로분석이 주를 이루기 때문에, 자연재해 시 지역을 대상으로 하는 재난대피모델에 관한 연구가 미진하여 도시 내의 재해영향권에 대한 재난대피모델 구축 사례가 없는 실정이다. 이에 본 연구에서는 Cube Avenue를 이용하여 거시통행 수요모형을 설계하고 미국 노스 다코다(North Dakota)주의 파고(Fargo)시의 도로 네트워크를 대상으로 재난 대피 시뮬레이션을 수행하였다. 결과적으로 본 연구에서 제안된 중규모 재난대피모델은 기존 통행수요모형의 네트워크와 입력 변수들을 이용하여서 동적 분석을 할 수 있어 시간과 비용을 절약할 수 있는 재난대피 시뮬레이션 분석에 활용 가능함을 확인할 수 있었다. 본 연구의 결과는 향후, 국내 대도시권에 적용이 가능하며 시나리오를 기반으로 한 다양한 재난모의 실험 및 평가가 가능한 모델 개발에 활용 가능할 것이다.

GIS를 이용한 도시지역 돌발홍수 침수예상지도 작성 및 대피강우기준 개발 (Mapping Inundation Areas by Flash Flood and Developing Rainfall Standards for Evacuation in Urban Settings)

  • 신상영;여창건;백창현;김윤종
    • 한국지리정보학회지
    • /
    • 제8권4호
    • /
    • pp.71-80
    • /
    • 2005
  • 본 연구는 XP-SWMM 모형과 GIS 기법을 이용하여 도시지역인 사당동 지역의 국지성 돌발홍수를 사례로 강우단계에 따른 내수침수상황을 모의하여 침수예상지역을 분석하고 그에 따른 대피 강우기준을 개발하였다. 사당천의 배수영향을 크게 받는 지역적 특성을 고려하여 배수관망해석시 사당천 좌안 기점수위를 지정, 경계, 위험 홍수위 및 만수위로 입력한 후 각 수위에 대하여 강우를 단계별로 적용하여 침수예상지역을 분석하였고, 이를 바탕으로 침수예상지도를 작성하였다. 분석된 결과를 통하여 사당동지역의 경우 대피강우기준을 2단계인 준비 및 경계강우(40mn.hr), 대피강우(65mm/hr)로 설정하였다. 본 연구에서 제시된 침수예상지도 작성 및 대피강우기준 개발 방법론을 응용함으로써 도시지역 침수피해에 대비한 합리적인 방재대책 및 침수피해 최소화를 위한 효과적인 대응체계를 구축하는데 크게 기여할 것으로 사료된다.

  • PDF

Perception-based analytical technique of evacuation behavior under radiological emergency: An illustration of the Kori area

  • Kim, Jeongsik;Kim, Byoung-Jik;Kim, Namhun
    • Nuclear Engineering and Technology
    • /
    • 제53권3호
    • /
    • pp.825-832
    • /
    • 2021
  • A simulation-based approach is proposed to study the protective actions taken by residents during nuclear emergencies using cognitive findings. Human perception-based behaviors are not heavily incorporated in the evacuation study for nuclear emergencies despite their known importance. This study proposes a generic framework of perception-based behavior simulation, in accordance with the ecological concept of affordance theory and a formal representation of affordance-based finite state automata. Based on the generic framework, a simulation model is developed to allow an evacuee to perceive available actions and execute one of them according to Newton's laws of motion. The case of a shadow evacuation under nuclear emergency is utilized to demonstrate the applicability of the proposed framework. The illustrated planning algorithm enables residents to compute not only prior knowledge of the environmental map, but also the perception of dynamic surroundings, using widely observed heuristics. The simulation results show that the temporal and spatial dynamics of the evacuation behaviors can be analyzed based on individual perception of circumstances, while utilizing the findings in cognitive science under unavoidable data restriction of nuclear emergencies. The perception-based analysis of the proposed framework is expected to enhance nuclear safety technology by complementing macroscopic analyses for advanced protective measures.

학교강당의 평면적 특징에 따른 대피효율에 관한 연구 (Evacuation Efficiency on School Auditorium Floor Layout)

  • 권준범;김덕수;김길채
    • 교육시설 논문지
    • /
    • 제24권2호
    • /
    • pp.3-10
    • /
    • 2017
  • This study compared evacuation effectiveness between the conventional school auditorium plan and a suggested hypothetical plan that was generated by a mathematical model, which is commonly applied in the field of industrial engineering. Recent school buildings became much more complicated in floor planning due to new social needs and modern curriculum than the old days. Nevertheless, architect's approach to floor composition in terms of fire emergency evacuation planning, still has no relation to optimized effective but relies more on an conventional school planning. Therefore, since school buildings are much more likely to be exposed to any fire related events than any other building types, emergency exit effectiveness based on spatial composition has to be seriously evaluated with a scientific method. The algorithm, which acquires the number of persons in each spatial type(node) per floor and the minimum physical distance between spatial types(arc), can propose the most optimized spatial layout per floor regarding emergency evacuation event. Consequently, this study evaluated school's fire exit effectiveness focusing on auditorium area with the scientific tool and suggested the most reliable spatial layout regarding possibile emergency evacuation event.

The Estimated Evacuation Time for the Emergency Planning Zone of the Kori Nuclear Site, with a Focus on the Precautionary Action Zone

  • Lee, Janghee;Jeong, Jae Jun;Shin, Wonki;Song, Eunyoung;Cho, Cheolwoo
    • Journal of Radiation Protection and Research
    • /
    • 제41권3호
    • /
    • pp.196-205
    • /
    • 2016
  • Background: The emergency planning zone (EPZ) of the city of Busan is divided into the precautionary actions zone (PAZ) and the urgent protective action planning zone; which have a 5-km radius and a 20-km to 21-km radius from the nuclear power plant site, respectively. In this study, we assumed that a severe accident occurred at Shin-Kori nuclear unit 3 and evaluated the dispersion speed of radiological material at each distance at various wind speeds, and estimated the effective dose equivalent and the evacuation time of PAZ residents with the goal of supporting off-site emergency action planning for the nuclear site. Materials and Methods: The total effective dose equivalent, which shows the effect of released radioactive materials on the residents, was evaluated using the RASCAL 4.2 program. In addition, a survey of 1,036 residents was performed using a standardized questionnaire, and the resident evacuation time according to road and distance was analyzed using the VISSIM 6.0 program. Results and Discussion: According to the results obtained using the VISSIM and RASCAL programs, it would take approximately 80 to 252.2 minutes for permanent residents to move out of the PAZ boundary, 40 to 197.2 minutes for students, 60 to 232.2 minutes for the infirm, such as elderly people and those in a nursing home or hospital, and 30 to 182.2 minutes for those temporarily within the area. Consequently, in the event of any delay in the evacuation, it is estimated that the residents would be exposed to up to $10mSv{\cdot}h^{-1}$ of radiation at the Exclusion Area Boundaries (EAB) boundary and $4-6mSv{\cdot}h^{-1}$ at the PAZ boundary. Conclusion: It was shown that the evacuation time for the residents is adequate in light of the time lapse from the initial moment of a severe accident to the radiation release. However, in order to minimize the evacuation time, it is necessary to maintain a system of close collaboration to avoid traffic congestion and spontaneous evacuation attempts.

초고층 건축물의 용도별 피난안전구역 성능확보 방안에 관한 연구 (A Study on the Improvement of the Refuge safety area in High-rise Buildings Type)

  • 이병현;이경희
    • 설비공학논문집
    • /
    • 제28권7호
    • /
    • pp.288-292
    • /
    • 2016
  • The purpose of this study was to improve the refuge safety area in the high-rise building type. Each simulation was conducted to evaluate the performance of three types in improving the refuge safety area. Targeting the first 63 floors (no refuge safety area), secondly, to target up to the $30^{th}$ floor (refuge safety area on the $30^{th}$ floor, $47^{th}$ floor) specified in domestic laws, and finally, the $20^{th}$ floor (evacuation safety area on the $20^{th}$ floor, $42^{th}$ floor) were considered as targets. Through this analysis, the following results were obtained : The floor for the refuge safety area through simulations showed that the evacuation time is low. It is necessary to improve the floor for the refuge safety area by using the characteristics of the domestic fire fighting vehicle. The first floor for the refuge safety area from the ground floor differs according to the distance and height of the building floor. However, in the case of a business facility it is 15F, and in the case of apartment housing, it is 20F.