• Title/Summary/Keyword: Area of evacuation

Search Result 230, Processing Time 0.03 seconds

Analysis of Evacuation Time According to Variation of Evacuation Stairs' Width in Large-Scale Goshiwons (대규모 고시원의 피난계단 폭의 변화에 따른 피난소요시간 분석)

  • Oh, Su-cheol;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.8 no.5
    • /
    • pp.641-651
    • /
    • 2022
  • This research compares and analyzes evacuation time depending on the change in stair width in case of fire at Goshiwons. For this, a simulation has been conducted based on possible evacuation time according to the calculation method for the number of people admittable to a specific target for fire fighting equipped with accommodation. Currently, Gosiwon, which is classified as an accommodation facility (a total floor area of 500 m2 or more), uses blind spots prescribed by the Fire Services Act, Building Act, and Parking Act to build a high-rise building on a small area of land, and most Gosiwon is transformed into a modified accommodation. This is in line with the owner's operating profit, so it is expected to show a continuous increase. Securing the golden time of Gosiwon evacuation time is the last bastion of Gosiwon residents who belong to the economically disadvantaged in our society, and we hope this study will serve as a starting point for discussions on revising related laws and regulations to establish a social safety net As a result of the evacuation simulation analysis, the evacuation time was the least when the width of the group and the evacuation stairs were expanded to 200cm, and the evacuation time of the existing building was reduced by up to 166.3 seconds by comparing 648.4 seconds and scenario 6. This analysis can be meaningful, in that the width of the evacuation stairs revision of related laws and regulations for the safety of multiplex available premises.

Establishing rainfall Evacuation Criteria for residents of steep slopes (급경사지 주민대피를 위한 강우기준 설정에 관한 연구 )

  • Chang Woo, Seo;Ki Bum, Park
    • Journal of Environmental Science International
    • /
    • v.31 no.11
    • /
    • pp.933-940
    • /
    • 2022
  • In this study, not only the increase in rainfall for a short period of time but also the increase in rainfall for a longer duration is frequently occurring according to climate change. Changes in rainfall patterns due to climate change are increasing damage to steep slopes. The Ministry of Public Administration and Security has been operating the criteria for evacuation of residents in steep slopes since 2015. However, the damage to steep slopes due to torrential rains in 2020 has been increasing. In this study, rainfall data from areas affected by steep slopes from 1999 to 2020 were collected and compared with the existing criteria(2015) for evacuation of residents at steep slopes of the Ministry of Public Administration and Security, and the status of the issuance of resident evacuation forecast was compared. Through this study, the rainfall criteria for each region were calculated and presented by reflecting the rainfall characteristics of the steep slope destruction area due to climate change, and it is believed that it can be used as a standard rainfall to reduce human casualties in the steep slope area in the future.

Evacuation Safety Evaluation of Tourist Hotels with the Fire Alarm Method

  • Moon, Sung-Chun;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.4
    • /
    • pp.363-375
    • /
    • 2021
  • The purpose of this study is to analyze the safety of evacuation using the Pathfinder program for the alert at once, the priority alarm method, the priority alarm method for the four floors above, and the sequential priority alarm method, which is a modification of the priority alarm method specified in the tourist hotel building. Currently, in Korea's National Fire Safety Codes (NFSC), fire alarm methods are compulsorily applied differently depending on the number of floors and total floor area of a building. Although the growth rate is getting faster due to the diversification of building structures, it is still an obstacle to improving evacuation safety to comply with the standardized fire alarm method in NFSC. As a result of the experiment, the evacuation time was found to be faster with the priority alarm method for the four floors above than the priority alarm method applied to the specific firefighting object. Compared to the priority alarm method applied to the tourist hotel, which is a specific firefighting target with 5 or more floors and a total floor area of more than 3,000m2, the time was shortened by 3.7 seconds when measured by applying the priority alarm method for the four floors directly above. This indicates that it is necessary to take measures to select a fire alarm method suitable for the structure and environmental conditions of the building rather than applying the uniform NFSC regulations.

A Study on the Architectural Planning of the Refuge Areas in Geriatric Hospitals Considering Horizontal Evacuation of the Elderly (노인요양병원에서 고령자의 수평 피난을 고려한 대피공간의 건축계획에 관한 연구)

  • Kim, Mijung;Kweon, Jihoon
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.29 no.3
    • /
    • pp.7-15
    • /
    • 2023
  • Purpose: This study was conducted with the aim of presenting spatial planning directions for evacuation spaces based on an analysis of the performance of horizontal evacuation during the early stages of fire incidents in a geriatric hospital. Methods: Based on a review of previous studies, the research model was designed by establishing occupancy conditions, evacuation, and fire scenarios. The analysis model was developed by considering vulnerable areas in terms of evacuation movement and analyzing the results of evacuation performance. Furthermore, the study analyzed the improvement in evacuation performance by arranging refuge areas. Results: The results of the study are as follows. Firstly, vulnerability spots were identified in terms of evacuation performance by schematizing Required Safe Egress Time, Available Safe Egress Time, and their differences. Secondly, the Required Safe Egress Time in the adjacent public spaces along the escape routes of occupants was found to be higher compared to the Available Safe Egress Time. Thirdly, the results of the correlation analysis between the difference in Available Safe Egress Time and Required Safe Egress Time during the early stages of a fire, as well as their constituent factors, demonstrated that user congestion is a more significant factor in compromising evacuation safety than the physical changes in the fire condition. Fourthly, the analysis of evacuation time was conducted by designating refuge areas where occupants can evacuate within a sufficient timeframe. This led to a decrease in the Required Safe Egress Time. Implications: This study is expected to be used as data on the direction of evacuation space planning to improve the evacuation performance of Geriatric Hospital.

A Space Analysis Model of Evacuation Overcrowding at Hospital Outpatient Department (병원 외래진료부에서의 피난 과밀 공간 분석 모델에 관한 연구)

  • Lee, Joohee;Kewon, Jihoon
    • Journal of the Regional Association of Architectural Institute of Korea
    • /
    • v.21 no.3
    • /
    • pp.109-116
    • /
    • 2019
  • This study aimed to suggest a quantitative model analyzing overcrowding area under emergency evacuation situation in the outpatient department of hospital. Overall study process included the review on legal conditions of an emergency evacuation, the investigation of precedent research documents and the analysis of spatial configuration. The user movement with considering exit gates and the one without considering exit gates were analyzed for routine activity condition. An agent-based simulation was applied for the analysis. Also, user movement for the emergency condition was tested with evacuation simulation. The variation of simulation conditions revealed the difference between overcrowding spaces from situation change. At all nodes, visit frequencies derived from different conditions and situations were compared. The overcrowding spaces are to increase the risk of delaying emergency evacuation time which is critical for user safety. It suggests the need for dispersing overcrowding spaces under evacuation situation. The suggested analysis model can evaluate overcrowding spaces in the outpatient department of hospital and provide locational data for distributing evacuation design resources.

GIS Based Analysis for the Capacity of Emergency Evacuation Shelters in Cheonan - Focused on Class-2 Shelters in Old Downtown (GIS를 활용한 천안지역 대피시설의 현황 및 수용능력 분석 -구도심지역의 2등급 대피시설을 중심으로)

  • Lee, Heewon;Sung, Min-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.9
    • /
    • pp.4572-4579
    • /
    • 2013
  • South Korea people and government pour growing interest on emergency evacuation shelters due to recent threatening of North Korea provocation. However, survey says the border area suffers lack of 278 shelters compared to population, needless to say the lack of class-2 shelter in case of provocation. Firstly, this study visualized the evacuation buffer area and summarized acceptable population for all class (1~4) shelters in Cheoan neighbor(dong). Specifically, for the class-2 shelter coverage in old downtown neighbor (Sungjung-dong, Jungang-dong, Munsung-dong), this study calculated evacuation excluded population and deficient shelter area through GIS buffer analysis. As a result, the old downtown needs $25,546m^2$ shelter area more that can accommodate 56%(30,657man) of the population.

Analysis of the Evacuation Safety with the Structure and Opening/Closing of Exits in a Fire at a Highway Service Area (고속도로 휴게소 화재 시 출입문의 구조와 개폐에 따른 피난안전성 분석)

  • Lee, Jai Young;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.2
    • /
    • pp.419-425
    • /
    • 2021
  • This study analyzed the safety of evacuation according to the number of exits and the direction of evacuation routes with evacuation simulations of the Pathfinder in case of a fire at a highway service area. It was also analyzed of the difference in RSET by comparing the single or double types of the exit of a facility. The results were as follows. When only one direction exit was opened, all of the RSET were exceeded. When two or more different directions were opened according to the general principle of evacuation, all results met the RSET. The simulations showed that two or more different directions were more shortened in RSET than the one same direction. The result of the types of doors showed that the single type door was shortened in RSET rather than the double type doors. For the evacuation safety in a fire at the highway service areas, firstly, it is necessary to secure two or more exits in a fire at all times. Secondly, the exits should not be same directions. Finally, it is suggested that the exit should be installed with a single type of door.

Research for establishing a model of optimizing civilian withdrawal plan for the border area (접경지역 최적 주민철수 계획수립을 위한 모형 연구)

  • Jung, Jae Hwan;Yun, Ho Yeong;Jeong, Chang Soon;Kim, Kyung Sup
    • Journal of the Society of Disaster Information
    • /
    • v.14 no.2
    • /
    • pp.219-229
    • /
    • 2018
  • Purpose: This research proposes an optimization model for effective evacuation routing and scheduling of civilians near the border area when full-scale war threats heighten. Method: To reflect the reality, administrative unit network is created using Kruscal's Algorithm, Harmony Search, CCRP based on the geographical features, population, and traffic data of real cities, and then, optimal civilian evacuation routes are found. Results: Optimal evacuation routes and schedules are computed by repetitive experiments, and it is found that the scenario that minimizes the average civilian evacuation time is effective for the civilian evacuation plan. Conclusion: By using the civilian evacuation plan this research proposes, at the time of establishing the actual civilian evacuation plan, quantitative analysis is used for the effective plan making rather than only depending.

A Study on the Visibility Measurement of CCTV Video for Fire Evacuation Guidance (화재피난유도를 위한 CCTV 영상 가시도 측정에 관한 연구)

  • Yu, Young-Jung;Moon, Sang-Ho;Park, Seong-Ho;Lee, Chul-Gyoo
    • Asia-pacific Journal of Multimedia Services Convergent with Art, Humanities, and Sociology
    • /
    • v.7 no.12
    • /
    • pp.947-954
    • /
    • 2017
  • In case of a fire in urban large structures such as super high-rise buildings, evacuation guidance must be provided to the occupants in order to minimize human deaths and injuries. Therefore, it is essential to provide emergency evacuation guidance when a major fire occurs. In order to effectively support evacuation guidance, it is important to identify major items such as fire location, occupant position, escape route, etc. Also, it is important to quickly identify evacuation areas where residents can safely evacuate from a fire. In this paper, we analyze the CCTV video and propose a method of measuring visibility of the evacuation zone from the smoke caused by the fire in order to determine the safety of evacuation area. To do this, we first extract the background video from the smoke video to measure the visibility of the specific area due to smoke. After generating an edge-extracted image for the extracted background video, the degree of visibility is measured by calculating the change in the edge strength due to smoke.

A Study on the Escape capacity for Evacuation safety Design of PBD foothold in Korea(II) (국내 PBD기반 피난안전설계를 위한 피난용량 산정에 관한 연구(II) - 멀티플렉스 공간의 재실자밀도 조사 -)

  • Jo, Nam-Hun;Seo, Dong-Goo;Hwang, Eun-Kyung;Hwang, Keum-Suk;Kwon, Young-Jin
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.210-215
    • /
    • 2008
  • As the rapid and various changing of social aspects, the structures are getting bigger, higher and more complex. The importance of evacuation is on the rise as increased using frequency of multiplex area and it's high population density. According to the result of a survey with 2 domestic multiplex population density, the maximum was 0.43(人/$m^2$) and 0.51(人/$m^2$). considering evacuation dangerousness, the maximum value will be suitable for computation of evacuation capacity and this will be submitted as a basic data for computation of evacuation capacity.

  • PDF