• Title/Summary/Keyword: Area dose

Search Result 1,097, Processing Time 0.031 seconds

Treatment of Intracranial Meningioma with Linac Based Radiosurgery (뇌수막종에서 선형가속기를 이용한 방사선수술 효과)

  • Kay Chul Seung;Yoon Sei Chul;Chung Su Mi;Ryu Mi Ryung;Kim Yeon Sil;Suh Tae Suk;Choi Kyuho;Son Byung Chul;Kim Moon Chan
    • Radiation Oncology Journal
    • /
    • v.19 no.2
    • /
    • pp.81-86
    • /
    • 2001
  • Prupose : To evaluate the role of linac based radiosurgery (RS) in the treatment of meningiomas, we retrospectively analyzed the results of clinical and follow up CT/MRI studies. Methods and Materials : From the 1988 July to 1998 April, twenty patients of meningioma had been treated with 6 MV linear accelerator based radiosurgery. Of the 20 patients, four $(20\%)$ were male and 16 $(80\%)$ were female. Mean age was 51 years old ($22\~78$ years old). Majority of intracranial location of tumor for RS were parasagittal and sphenoid wing area. RS was done for primary treatment in 6 $(30\%)$, postoperative residual lesions in 11 $(55\%)$ and regrowth after surgery in 3 $(15\%)$. Mean tumor volume was $5.72\;cm^3\;(0.78\~15.1\;cm^3)$ and secondary collimator size was 2.04 cm $(1\~3\;cm)$. The periphery of tumor margin was prescribed with the mean dose of 19.6 Gy $(9\~30\;Gy)$ which was $40\~90\%$ of the tumor center dose. The follow up duration ranged from 2.5 to 109 months (median 53 months). Annual CT/MRI scan was checked. Results : By the follow up imaging studies, the tumor volume was reduced in 5 cases $(25\%)$, arrested growth in 14 cases $(70\%)$, and increased size in 1 case $(15\%)$. Among these responsive and stable 19 patients by imaging studies, there showed loss of contrast enhancement after CT/MRI in four patients. In clinical response, nine $(45\%)$ patients were considered improved condition, 10 $(50\%)$ patients were stable and one $(5\%)$ was worsened to be operated. This partly resulted in necrosis after surgery. Conclusion : The overall control rate of meningiomas with linac based RS was $95\%$ by both imaging follow-up and clinical evaluation. With this results, linac based RS is considered safe and effective treatment method for meningioma.

  • PDF

Development of Three-Dimensional Trajectory Model for Detecting Source Region of the Radioactive Materials Released into the Atmosphere (대기 누출 방사성물질 선원 위치 추적을 위한 3차원 궤적모델 개발)

  • Suh, Kyung-Suk;Park, Kihyun;Min, Byung-Il;Kim, Sora;Yang, Byung-Mo
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.1
    • /
    • pp.31-39
    • /
    • 2016
  • Background: It is necessary to consider the overall countermeasure for analysis of nuclear activities according to the increase of the nuclear facilities like nuclear power and reprocessing plants in the neighboring countries including China, Taiwan, North Korea, Japan and South Korea. South Korea and comprehensive nuclear-test-ban treaty organization (CTBTO) are now operating the monitoring instruments to detect radionuclides released into the air. It is important to estimate the origin of radionuclides measured using the detection technology as well as the monitoring analysis in aspects of investigation and security of the nuclear activities in neighboring countries. Materials and methods: A three-dimensional forward/backward trajectory model has been developed to estimate the origin of radionuclides for a covert nuclear activity. The developed trajectory model was composed of forward and backward modules to track the particle positions using finite difference method. Results and discussion: A three-dimensional trajectory model was validated using the measured data at Chernobyl accident. The calculated results showed a good agreement by using the high concentration measurements and the locations where was near a release point. The three-dimensional trajectory model had some uncertainty according to the release time, release height and time interval of the trajectory at each release points. An atmospheric dispersion model called long-range accident dose assessment system (LADAS), based on the fields of regards (FOR) technique, was applied to reduce the uncertainties of the trajectory model and to improve the detective technology for estimating the radioisotopes emission area. Conclusion: The detective technology developed in this study can evaluate in release area and origin for covert nuclear activities based on measured radioisotopes at monitoring stations, and it might play critical tool to improve the ability of the nuclear safety field.

Acquisition of Monochromatic X-ray using Graded Multilayer Mirror (Graded 다층박막거울을 이용한 단색 엑스선 획득)

  • Ryu, Cheolwoo;Choi, Byoungjung;Son, Hyunhwa;Kwon, Youngman;Kim, Byoungwook;Kim, Youngju;Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.205-211
    • /
    • 2015
  • At a recent medical imaging technology, the major issue of X-ray diagnosis in breast cancer is the early detection of breast cancer and low patient's exposure dose. As one of studies to acquire a monochromatic X-ray, Technologies using multilayer mirror had been preceded. However, a uniform multilayer mirror that consists of uniform thin-film thickness can acquire a monochromatic X-ray only in the partial area corresponds to angle of incidence of white X-ray, so there are limits for X-ray imaging technology applications. In this study, we designed laterally graded multilayer mirror(below GML) that reflects same monochromatic X-ray over the entire area of thin-film mirror, which have the the thickness of the linear gradient that correspond to angle of incidence of white X-ray. By using ion-beam sputtering system added the mask control system we fabricated a GML which has size of $100{\times}100mm^2$. The GML is designed to achieve the monochromatic X-ray of 17.5kev energy and has thin-film thickness change from 4.62nm to 6.57nm(3.87nm at center). It reflects the monochromatic X-ray with reflectivity of more than 60 percent, FWHM of below 2.6keV and X-ray beam width of about 3mm. The monochromatic X-ray corresponded to 17.5keV using GML would have wide application in development of mammography system with high contrast and low dose.

Measurement and Monte Carlo Simulation of 6 MV X-rays for Small Radiation Fields (선형가속기의 6 MV X-선에 대한 소형 조사면 측정과 몬테 카를로 시뮬레이션)

  • Jeong Dong Hyeok;Lee Jeong Ok;Kang Jeong Ku;Kim Soo Kon;Kim Seung Kon;Moon Sun Rock
    • Radiation Oncology Journal
    • /
    • v.16 no.2
    • /
    • pp.195-202
    • /
    • 1998
  • Purpose : In order to obtain basic data for treatment plan in radiosurgery, we measured small fields of 6 MV X-rays and compared the measured data with our Monte Carlo simulations for the small fields. Materials and Methods : The small fields of 1.0, 2.0 and 3.0 cm in diameter were used in this study. Percentage depth dose (PDD) and beam Profiles of those fields were measured and calculated. A small semiconductor detector, water phantoms, and a remote control system were used for the measurement Monte Carlo simulations were Performed using the EGS4 code with the input data prepared for the energy distribution of 6 MV X-rays, beam divergence, circular fields and the geometry of the water phantoms. Results : In the case of PDD values, the calculated values were lower than the measured values for all fields and depths, with the differences being 0.3 to 5.7% at the depths of 20 to 20.0 cm and 0.0 to 8.9% at the surface regions. As a result of the analysis of beam profiles for all field sizes at a depth of loom in water phantom, the measured 90% dose widths were in good agreement with the calculated values, however, the calculated Penumbra radii were 0.1 cm shorter than measured values. Conclusion : The measured PDDs and beam profiles agreement with the Monte Carlo calculations approximately. However, it is different when it comes to calculations in the area of phantom surface and penumbra because the Monte Carlo calculations were performed under the simplified geometries. Therefore, we have to study how to include the actual geometries and more precise data for the field area in Monte Carlo calculations. The Monte Carlo calculations will be used as a useful tool for the very complicated conditions in measurement and verification.

  • PDF

Dietary Intakes, Plasma Levels and Urinary Excretions of Taurine in Adolescents and Adults Residing in Seoul Area (서울지역 청소년 및 성인의 타우린 섭취량, 혈중 농도 및 소변내 배설량에 관한 연구)

  • 박태선;강혜원;박정은;조세현
    • Journal of Nutrition and Health
    • /
    • v.34 no.4
    • /
    • pp.440-448
    • /
    • 2001
  • As diverse physiological functions of taurine have been reported, taurine-containing health drinks and products are marketed worldwide for the treatment of various conditions such as improvements of liver, heart and circulatory functions or as an aid to athletic performance. Although animal studies have shown that taurine is fairly safe when supplemented in the diet for an extended period, the effective dose range of taurine for dietary supplements is in controversy. Reports on dietary taurine intakes have been sparse, and would serve as a guideline for determining an appropriate taurine dosage. The present study was aimed to estimate dietary intake level of taurine using the taurine content database of commonly used food stuffs established recently in our laboratory, and also to evaluate plasma concentration and urinary excretion of taurine in adolescents and adults residing in Seoul area. Dietary taurine intakes of the subjects were 219$\pm$16.9mg/day for 16-19 years old(n=123), 177$\pm$18.1mg/day for adults older than 20 years old(n=123). Male subjects(n=115) consumed 216$\pm$21.1mg of taurine/day, while female subjects(n=131) consumed 181$\pm$14.3mg of taurine/day(p<0.05). The level of dietary taurine intake was positively correlated with the levels of dietary intakes of energy, carbohydrate, total lipids, cholesterol, vitamin A, vitamin B$_1$, niacin, vitamin C, calcium, phosphorous, sodium and potassium at p<0.01, and with dietary intakes of iron and animal lipids at p<0.05, respectively. Plasma taurine concentration of subjects were 135$\pm$5.9$\mu$mol/L, which is considered to be within a normal range for healthy subjects. The subjects excreted 1158$\pm$72.7nmol/ of tarine mg creatinine in their urine, which is approximated as 150-170mg of taurine/24hr urine based on the assumption that 18mg creatinine/kg/day is excreted in the urine of healthy adults, and this would be about 80% of the daily taurine intake observed in the same subjects. Dietary taurine intake level was positively correlated with plasma taurine concentration, as well as with urinary taurine excretion corrected by creatinine excretion at p<0.05. The present study was the first report of taurine intake, and plasma concentration and urinary excretion of taurine in a Korean population so far, and these results would serve as an index for the future study evaluating taurine status in a diverse population within and outside Korea. (Korean J Nutrition 34(4) : 440~448, 2001)

  • PDF

Pattern on Ascaris lumbricoides Infection in a Rural Area of Keread (한국농촌(韓國農村)에 있어서의 회충감염상(蛔虫感染相))

  • Lee, Joon-Sang;Kim, Kwang-Rock;Ko, Dae-Kyoung;Sung, Dae-Rim;Lee, Ja-Young;Rim, Han-Jong
    • Journal of agricultural medicine and community health
    • /
    • v.5 no.1
    • /
    • pp.28-33
    • /
    • 1980
  • This study was undertaken to evaluate the present status of A. lumbricoides infection in a rural area of Korea. The 307 residents of all age group in Gumsa Myun, Yeo Ju Gun were examined by Kato's cellophane thick smear technique. Pyrantel pamoste was administered to the Ascaris infection cases by a single dose of 5mg/kg of body weight. The whole amount of 24 hour stool during two or three consecutive days were collected sepatately. The expelled A. lumbricoides worms from the unfiltered stool remnants were collected. They were measured by the length and weight, and the sex of the worms were differentiated. The results are as follows: 1) The incidence of A. lumbricoids infection of the 307 specimens examined was 40.1%(male: 40.9%, female:39.0%). The difference according to guman sex distribution was not statistically significant. 2) Seventy two Ascaris infected cases expelled 163 worms of various size. The mean number of worms per infected case were calculated as 2.3. The sex ratio of examined female and male Ascaris was 1.5:1 3) Among the expelled 97 female worms, the genital girdle were found in 60 female worms(61.9%). Genital girdle of gemale worm was located from the head in the position of $38{\pm}4$ of total length 100. 4) The average body length of male Ascaris was $16.3{\pm}3.1cm$ and female Ascaris was $21.7{\pm}3.5cm$ 5) The relationship between the weight(Y) and the length(X) of individual Ascaris worm was plotted. Y(gm).0.32$\fallingdotseq$(cm)-3.1 in female and Y(gm)$\fallingdotseq$0.1X(cm)-0.1 in male.

  • PDF

Comparative evaluation of computed tomography for dental implants on the mandibular edentulous area (하악 무치악 부위의 임플란트 이식을 위한 전산화단층촬영 영상의 비교 평가)

  • Sun, Kyung-Hoon;Jeong, Ho-Gul;Park, Hyok;Park, Chang-Seo;Kim, Kee-Deog
    • Imaging Science in Dentistry
    • /
    • v.39 no.1
    • /
    • pp.27-33
    • /
    • 2009
  • Purpose: The purpose of this study was to evaluate the clinical usefulness of the recently developed multi-detector computed tomography and cone beam computed tomography in pre-operative implant evaluation, by comparing them with the single detector computed tomography, already confirmed for accuracy in this area. Materials and Methods: Five partially edentulous dry human mandibles, with $1{\times}1mm$ gutta percha cones, placed in 5mm intervals posterior to the mental foramen on each side of the buccal part of the mandible, were used in this study. They were scanned as follows: 1) Single detector computed tomography: slice thickness 1mm, 200mA, 120kV 2) Multi-detector computed tomography: slice thickness 0.75mm, 250mA, 120kV 3) Cone beam computed tomography: 15mAs, 120kV Axial images acquired from three computed tomographies were transferred to personal computer, and then reformatted cross-sectional images were generated using V-Implant $2.0^{(R)}$ (CyberMed Inc., Seoul, Korea) software. Among the cross-sectional images of the gutta perch a cone, placed in the buccal body of the mandible, the most precise cross section was selected as the measuring point and the distance from the most superior border of the mandibular canal to the alveolar crest was measured and analyzed 10 times by a dentist. Results: There were no significant intraobserver differences in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). There were no significant differences among single detector computed tomography, multi-detector computed tomography and cone beam computed tomography in the distance from the most superior border of the mandibular canal to the alveolar crest (p>0.05). Conclusion: Multi-detector computed tomography and cone beam computed tomography are clinically useful in the evaluation of pre-operative site for mandibular dental implants, with consideration for radiation exposure dose and scanning time.

  • PDF

Handover Scheme between WiFi and Mobile WiMax (WiFi와 mobile WiMax간 핸드오버 방안)

  • Park, Seung-Kyun
    • The Journal of the Korea Contents Association
    • /
    • v.11 no.1
    • /
    • pp.34-41
    • /
    • 2011
  • At present wireless internet access service is available through the 3G network, mobile WiMAX and WiFi anytime and anywhere. In this environment where there are various networks, users should be able to select specific networks depending on different situations. And it is necessary to provide mobility support between homogeneous and between heterogenous networks. Given this situation, the many proposals have been presented to link 3G, which has the largest service area among various networks, with mobile WiMAX(IEEE 802.16e), or with WiFi(IEEE 802.11). But, recently, with the increasing volume of wireless internet use and wireless internet data, due to the advents of net-book, e-book and smart phone, the service area of WiFi and mobile WiMAX has rapidly expanded. Especially, the availability of real-time application such as internet phone has led to the relative shrinking of the proportion of 3G mobile communication network giving conventional voice service, and enlargement of those of wireless internet access networks like WiFi and mobile WiMAX. This paper suggests a handover scheme based on PMIPv6, whitch support mobility between WiFi and mobile WiMAX, and minimizes handover delay. In this scheme, the mobile node has a dual stack structure composed of two interfaces-WiFi and mobile WiMAX. Since WiFi dose not support mobility, it is suggested that the mobile node have the capacity to deal with handover signaling between gateway in case of handover between homogeneous networks. This handover scheme, suggested comparing with current handovers between homogeneous networks, has proved, in its analytic evaluation, to be able to reduce handover, transmission, and signaling overhead.

Contamination Assessment of Heavy Metals in River Sediments (For the Surface Sediments from Nakdong River) (하천 퇴적물 내 중금속 오염도 평가에 관한 연구 (낙동강 수계 표층 퇴적물을 대상으로))

  • Kim, Shin;Ahn, Jungmin;Jung, Kangyoung;Lee, Kwonchul;Kwon, Heongak;Shin, Dongseok;Yang, Deukseok
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.4
    • /
    • pp.460-473
    • /
    • 2017
  • In order to certificate the contamination assessment of heavy metals in surface sediments from the Nakdong river. Surface sediments were collected of 24 sampling sites (main 14st., tributary 10st.) and analyzed for grain size heavy metals contents. Study area mainly composed of sand (avg. 94.1%) and mean grain size was $1.46{\Phi}$ on average. Heavy metals contents (avg. Al: 12.5%, Zn; 74.4, Cr: 45.3, Li: 26.0, Pb: 17.1, Ni: 10.5, Cu: 7.8, Cd: 0.22 mg/kg) were relatively high contents in the composed of fine sediments. In addition, the results of pearson's correlation coefficient showed that most heavy metals and grain size (silt and clay) were highly correlated. The contents of Zn (6st.) and Ni (1st.) evaluated as moderately polluted, Zn (6st.) evaluated as LEL when compared with sediment quality standard of USEPA and Ontario sediment quality guidelines. Most heavy metals contents were I levels that dose not affected the benthos when compared with sediment pollution evaluation standard of NIER. The results of EX, EF, Igeo and CF showed the contents of Zn, Pb and Cd exceed the background contents and distributing of anthropogenic pollution and evaluated as moderately polluted level. And Nm-08 were relatively high level of contamination in the study area. However as results of PLI (less than 1), all sampling sites were evaluated unpolluted level.

Effects of Bisphenol A on Gene Expression and Apoptosis of Leydig Cells in the Mouse Testis (생쥐 정소에서 비스페놀 에이 (Bisphenol A)가 Leydig Cell의 유전자 발현과 세포자멸사에 주는 영향)

  • Eo, Jin-Won;Lim, Hyun-Jung
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.35 no.3
    • /
    • pp.181-191
    • /
    • 2008
  • Objective: Environmental chemicals alter reproduction, growth, and survival by changing the normal function of the endocrine system. Bisphenol A (BPA), one of the endocrine disruptors, is known to be an estrogen receptor agonist. Therefore, we hypothesized that BPA may affect male reproduction including spermatogenesis in the mouse testis. Methods: We used 7-week-old ICR mice. The first experiment group received BPA in sesame oil (vehicle, 1 mg/kg, 10 mg/kg, and 100 mg/kg) by i.p. injection and mice were sacrificed 24 hr later. The second experiment group received BPA (vehicle, 10 ${\mu}g/kg$, 1 mg/kg, and 100 mg/kg) daily for 14 days by subcutaneous injection. Expression of cell type-specific marker genes in the testis was evaluated by RT-PCR. Histological analysis, immunofluorescence staining, and TUNEL staining were also performed. Results: RT-PCR analyses showed that expression of luteinizing hormone receptor (LHR), a marker gene for the Leydig cell, was notably decreased in the testes of high dose-exposed mice. No obvious difference in the histology of testes was noted among treatment groups. Immunostaining of LHR in the first experiment group did not show noticeable difference in LHR protein expression in Leydig cells. Immunohistochemistry also revealed heightened expression of the immunoreactive Bax in the treatment group, and this was accompanied by positive TUNEL staining in the interstitial area within testis where Leydig cells reside. Conclusions: Our result suggests that BPA affects Leydig cell functions by altering gene expression and by increasing apoptosis in the mouse testis.