• Title/Summary/Keyword: Area Efficiency

Search Result 4,867, Processing Time 0.034 seconds

A Study on the Efficiency of Fishing-Ports Based on Super-SBM (Super-SBM을 이용한 어항의 효율성분석에 관한 연구)

  • Park, Cheol-Hyung
    • The Journal of Fisheries Business Administration
    • /
    • v.41 no.3
    • /
    • pp.129-151
    • /
    • 2010
  • This study is to analyze the efficiency of Korean fishing ports using DEA. First, the study calculated the efficiency scores based on a CCR-BCC framework and hence technical, pure technical, and scale efficiency scores are seperated for the 38 fishing ports under study. The Average of technical, pure technical, and scale efficiency are turned out to be 0.6834, 0.8582, and 0.7774 respectively. The 15 fishing ports are fully efficient under the constant returns to scale while 21 fishing ports under the variable returns to scale. Second, the super efficiency scores are also calculated under the radial model without the consideration of slacks. The highest score is turned out to be 4.4984 for the P16 fishing port with the average score of 0.9652 for the entire fishing ports. Nevertheless, P16 fishing port has showed up only once as a reference set. On the other hand, P34 fishing port has showed up 11 times as a reference set, which scored the second highest score of 2.9815. Finally the super efficiency scores are calculated under the non-radial model with the explicit consideration of slacks. Now the P34 fishing port scored the highest score of 2.3424 with even 15 times referred to a bench-mark. Therefore the importance of P34 fishing port is emphasized once again on the field of bench-marking for the efficiency of fishing ports. When the targets for the input factors to improve the efficiency of each DMU are calculated the area of fishing port needs the most adjustment to be reduced for 40.36% on the average, while the cosignment sales area does the least adjustment for 13.70%.

The Analyses of the Operational Efficiency and Efficiency Factors of Retail Stores Using DEA Model (DEA 모형을 활용한 소매점의 효율성 및 결정요인 분석)

  • Ko, Kyungwan;Kim, Daecheol
    • Korean Management Science Review
    • /
    • v.31 no.4
    • /
    • pp.135-150
    • /
    • 2014
  • This paper analyzes the operational efficiency of 91 individual retail stores in Seoul by a two-step procedure. In the first step, a data envelopment analysis (DEA) model is used to identify the efficiency scores. Three inputs (store size, number of items, and number of employees) and two outputs (sales and number of customers) are used for the efficiency measurement. In the second step, a Tobit regression model is used to identify the drivers of efficiency. DEA efficiency scores are used to test hypotheses on the impact of five independent variables, namely store age, number of items per store size, number of items per employee, trade area index, and number of competitors. Results of the Tobit analysis show that number of items per store size, number of items per employee, and number of competitors play a significant role in influencing the operational efficiency of retail stores. Managerial implications of the study are discussed.

Analysis of RCSTP Wastewater Characteristics and Installed Treatment Process in Bong-Hwa Gun (봉화군에 도입된 마을하수도 하수 특성 및 처리 공법 분석)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.15 no.4
    • /
    • pp.453-460
    • /
    • 2013
  • Rural area sewage distribution rate is 40 % less than urban area. Previous research results announced that one of the reason in water resource pollution was caused of low rural area sewage distribution rate. Analysis on operation result of 11 RCSTP in Bong-hwa area which is located at the upper region of An-dong Dam and Im-ha Dam. Based on operation result, an analysis on characteristics of wastewater in Bong-hwa and treatment efficiency of installed treatment process was conducted. The wastewater influent of Bong-hwa contained high organic matter and nutrient than those of urban area. Treatment process showed totally stable treatment efficiency. But, The treatment efficiency for nutrient showed high fluctuation. This result means which is need to operation condition control of nutrient treatment when operating RCSTP.

Area-constrained NTC Manycore Architecture Design Methodology (면적 제약 조건을 고려한 NTC 매니코어 설계 방법론)

  • Chang, Jin Kyu;Han, Tae Hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.866-869
    • /
    • 2015
  • With the advance in semiconductor technology, the number of elements that can be integrated in system-on-chip(SoC) increases exponentially, and thus voltage scaling is indispensable to enhance energy efficiency. Near-threshold voltage computing(NTC) improves the energy efficiency by an order of degree, hence it is able to overcome the limitation of conventional super-threshold voltage computing(STC). Although NTC-based low performance manycore system can be used to maximize energy efficiency, it demands more number of cores to sustain the performance, which results in considerable increase of area. In this paper, we analyze NTC manycore architecture considering the trade-offs between performance, power, and area. Therefore, we propose an algorithmic methodology that can optimize power consumption and area while satisfying the required performance by determining the constrained number of cores and size of caches and clusters in NTC environment. Experimental results show that proposed NTC architecture can reduce power consumption by approximately 16.5 % while maintaining the performance of STC core under area constraint.

  • PDF

The opening efficiency difference of guide net in finless porpoise escape device by the type of extension net in stow net (안강망의 그물 구성에 따른 상괭이 탈출 유도망의 전개 성능 차이)

  • LEE, Gun-Ho;KIM, Hyun-Young;SONG, Dae-Ho
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.57 no.4
    • /
    • pp.271-282
    • /
    • 2021
  • This study aims to understand the opening efficiency of the finless porpoise escape guide net by the type of extension net that is the part to which the escape guide net is attached in stow net. To this end, extension nets were manufactured in full size and the net mouth area and towing tension were investigated according to the towing speed (0.2, 0.4, 0.6 and 0.8 m/s) and the type of extension net (25 mm net and raschel net) in the water tank. As a result, the net mouth area of the guide net was larger when the raschel net was used for the extension net than when the 25 mm net was used under all towing speeds. In addition, regardless of the type of extension net, the net mouth area reached about 80% of the maximum value at a towing speed of 0.4 m/s. In the field, fishing operation of stow net is performed only when the current speed is above 0.4 m/s. Therefore, the speed of 0.4 m/s was confirmed as a meaningful value to determine whether it is possible to operate. As a result of analyzing the relationship between the net mouth area of the guide net and the towing tension, it was confirmed that the difference in the net mouth area of the guide net according to the type of the extension net was due to the difference in the solidity ratio.

Structural Analysis Model to Evaluate the Mechanical Reliability of Large-area Photovoltaic Modules (대면적 태양광 모듈의 기계적 신뢰성 평가를 위한 모델)

  • Noh, Yo Han;Jeong, Jeong Ho;Lee, Jaehyeong
    • Current Photovoltaic Research
    • /
    • v.10 no.2
    • /
    • pp.56-61
    • /
    • 2022
  • Recently, the expansion of the domestic solar market due to the promotion of eco-friendly and alternative energy-related policies is promising, and it is expected to lead the high-efficiency/high-power module market based on M10 or larger cells to reduce LCOE, 540-560W, M12 based on M10 cells Compared to the existing technology with an output of 650-700W based on cells, it is necessary to secure competitiveness through the development of modules with 600W based on M10 cells and 750W based on M12 cells. For the development of high efficiency/high-power n-type bifacial, it is necessary to secure a lightweight technology and structure due to the increase in weight of the glass to glass module according to the large area of the module. Since the mechanical strength characteristics according to the large area and high weight of the module are very important, design values such as a frame of a new structure that can withstand the mechanical load of the Mechanical Load Test and the location of the mounting hole are required. In this study, a structural analysis design model was introduced to secure mechanical reliability according to the enlargement of the module area, and the design model was verified through the mechanical load test of the actual product. It can be used as a design model to secure the mechanical reliability required for PV modules by variables such as module area, frame shape, and the location and quantity of mounting holes of the structural analysis model verified. A relationship of output drop can be obtained.

Effect of the Passage Area Ratio of an Impeller on the Performance of Two-Dimensional Centrifugal Compressors (임펠러의 유로 면적비가 2차원 원심압축기의 성능에 미치는 영향)

  • Park, Han-Young;Shin, You-Hwan;Choi, Hang-Cheol;Kim, Kwang-Ho;Chung, Jin-Taek
    • The KSFM Journal of Fluid Machinery
    • /
    • v.11 no.5
    • /
    • pp.22-29
    • /
    • 2008
  • This study is performed to understand the effect of the variation in the passage area of a two-dimensional impeller on its performance characteristics. We observe the results with changing the area ratio of inlet to outlet about $1{\sim}2.8$. A comparison between the experimental and numerical results was performed for the same configuration in order to verify the reliability of the CFD code. Overall characteristics in the passages of impeller were analyzed in detail including streamline, Mach number, pressure and polytropic efficiency distribution. When the passage area ratio exceeds 2, the pressure ratio is high. An area ratio of 2.3 showed the highest efficiency. The results will be used as useful reference data to establish the design concept of two-dimensional impeller and to improve its performance.

Effect of Ionic Liquid on Increased Surface Area Crystallization Process for Vancomycin (표면적이 증가된 반코마이신 결정화 공정에서 이온성 액체의 영향)

  • Kim, Sung-Jae;Kim, Jin-Hyun
    • Microbiology and Biotechnology Letters
    • /
    • v.42 no.3
    • /
    • pp.297-301
    • /
    • 2014
  • We examined the effect of ionic liquid on the crystallization efficiency of vancomycin in an increased surface area crystallization with silica gel. The crystallization efficiency was improved by the addition of ionic liquid, [BMIm][$BF_4$]. The addition of ionic liquid (20%, v/v) on the increased surface area crystallization with silica gel dramatically reduced the crystallization time by 6 folds (4 h), compared with the results of the case where the surface area-increasing material and ionic liquid had not been added. In addition, the crystal size of vancomycin was decreased and the crystal quality of vancomycin was improved by increasing the addition of ionic liquid.

Coverage Scheduling control Algorithm in MANET (모바일 에드 혹 네트워크에서 커버리지 스케쥴링 제어 알고리즘)

  • Oh, Young-jun;Lee, Kang-whan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2014.10a
    • /
    • pp.848-850
    • /
    • 2014
  • Mobile Ad hoc Networks(MANET) is consist of node that has mobility, MANET build cluster formation for using energy efficient. In existing LEACH algorithm elect cluster head node in coverage area by distribution function. However, when the cluster head node, that elected by distribution function, is divided coverage area unevenly, the network can't consumption energy efficiency. To solve this problem, we proposed CSWC(Coverage Scheduling Weight-value Control) algorithm. When the coverage area is divided nonchalance, proposed algorithm increased number of hops, that determines coverage area, for balance coverage area. As the result proposed algorithm is set balance coverage area, the network consumption energy efficiency.

  • PDF

Low-cost Contact formation of High-Efficiency Crystalline Silicon Solar Cells by Plating

  • Kim D. S.;Lee E. J.;Kim J.;Lee S. H.
    • New & Renewable Energy
    • /
    • v.1 no.1 s.1
    • /
    • pp.37-43
    • /
    • 2005
  • High-efficiency silicon solar cells have potential applications on mobile electronics and electrical vehicles. The fabrication processes of the high efficiency cells necessitate com placated fabrication precesses and expensive materials. Ti/Pd/Ag metal contact has been used only for limited area In spite of good stability and low contact resistance because of Its expensive material cost and precesses. Screen printed contact formed by Ag paste causes a low fill factor and a high shading loss of commercial solar cells because of high contact resistance and a low aspect ratio. Low cost Ni/Cu metal contact has been formed by using a low cost electroless and electroplating. Nickel silicide formation at the interface enhances stability and reduces the contact resistance resulting In an energy conversion efficiency of $20.2\%\;on\;0.50{\Omega}cm$ FZ wafer. Tapered contact structure has been applied to large area solar cells with $6.7\times6.7cm^2$ in order to reduce power losses by the front contact The tapered front metal contact Is easily formed by the electroplating technique producing $45cm^2$ solar cells with an efficiency of $21.4\%$ on $21.4\%\;on\;2{\Omega}cm$ FZ wafer.

  • PDF