• Title/Summary/Keyword: Arch width

Search Result 241, Processing Time 0.021 seconds

Long-term stability of maxillary and mandibular arch dimensions when using rapid palatal expansion and edgewise mechanotherapy in growing patients

  • Kim, Ki Beom;Doyle, Renee E.;Araujo, Eustaquio A.;Behrents, Rolf G.;Oliver, Donald R.;Thiesen, Guilherme
    • The korean journal of orthodontics
    • /
    • v.49 no.2
    • /
    • pp.89-96
    • /
    • 2019
  • Objective: The purpose of this study was to assess the long-term stability of rapid palatal expansion (RPE) followed by full fixed edgewise appliances. Methods: This study included 67 patients treated using Haas-type RPE and non-extraction edgewise appliance therapy at a single orthodontic practice. Serial dental casts were obtained at three different time points: pretreatment ($T_1$), after expansion and fixed appliance therapy ($T_2$), and at long-term recall ($T_3$). The mean duration of the $T_1-T_2$ and $T_2-T_3$ periods was $4.8{\pm}3.5years$ and $11.0{\pm}5.4years$, respectively. The dental casts were digitized, and the computed measurements were compared with untreated reference data. Results: The majority of treatment-related increases in the maxillary and mandibular arch measurements were statistically significant (p < 0.05) and greater than expected for the untreated controls. Although many measurements decreased postretention ($T_2-T_3$), the net gains persisted for all of the measurements evaluated. Conclusions: The use of RPE therapy followed by full fixed edgewise appliances is an effective method for increasing maxillary and mandibular arch width dimensions in growing patients.

A Study on the Cause and the Effect of the Widths of Sung-Rye-Mun Gate Arches (숭례문 홍예너비와 도로 폭 및 문루 어간(御間)거리의 상관성 연구 - 화성(華城) 팔달문(八達門), 흥인지문(興仁之門)과 비교를 통하여 -)

  • Ryoo, Seong-Lyong
    • Journal of architectural history
    • /
    • v.19 no.2
    • /
    • pp.117-132
    • /
    • 2010
  • The Great south gate of Seoul Castle, Sung-Rye-Mun, the east gate of Seoul Castle, Hung-In-Ji-Mun, the south gate of Hwa-Sung Castle, Pal-Dal-Mun and the north gate of Hwa-Sung Castle, Jang-An-Mun are typical significant castle gate of Chosun Dynasty. They have a lot in common with exterior. Additionally there are also something common in dimensions. At first, the arch dimensions of lower story is very similar and the columns of upper story are the regular intervals. Purpose of this study is to confirm similarities above mentioned were intended on purpose and if then what was the reason. The results of this study were described separately as follows. 1. The widths of the arches were based on each 16Cheok and 18Cheok. 2. The heights of the arches followed less strictly rule than the widths. 3. The widths of the arches, 16Cheok was same size as width of middle-size road (中路, Jung-Ro) inside the Castle town in Chosun Dynasty. 4. The widths of the arches, 16Cheok was the standard size of exit went through castle and then the standard size of road arrived at one's destination. 5. The widths of the arches had an effect on the intervals between the columns of the upper story. Finally we recognized that in Chos${\u{o}}$n Dynasty the widths of the gate arches in Seoul castle and Hwa-Sung castle had relevance to the city planning largely and widths of the gate arches had an effect on the intervals between the columns of the upper story partly.

The Evaluation of Custom Foot Orthotics for Injury Prevention of Joggers (달리기 동호인들의 상해예방을 위한 맞춤형 발 보장구의 평가연구)

  • Kim, Ro-Bin
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.1
    • /
    • pp.19-30
    • /
    • 2006
  • The purpose of this study was to examine the effect of foot orthotics on the overall comfort and muscle activity during running. The subjects were 10 members from the joggers' club which consisted of 2 women and 8 men. These individuals ran on the treadmill by 4.0m/s speed with and without the custom foot orthotics. The data concerning the overall comfort was collected by a questionairre that examined the overall comfort, heel cushioning, forefoot cushioning, medio-lateral control, arch height, heel cup fit, shoe heel width, forefoot width, and shoe length The MegaWin ver. 2.1(Mega Electronics lid, Ma. Finland) was used to gain electromyography signals of the muscle activity; Tibialis anterior, medial gastronemius, lateral gastronemius, vastus lateralis, vastus medialis, biceps femoris, and rectus femoris were measured. The results of the study were as follows. 1. During running the overall comfort was higher for the foot arthotic condition than the nonorthotic condition. Among the inquiries the overall comfort showed the biggest difference comparing the two conditions. and the shoe heel width showed the highest score for contort. 2 The muscle activity of the biceps femoris, and vastus lateralis in the stance period decreased. due to the foot orthotics. The muscle activity of the vastus medialis in the swing period also decreased and the muscle activity tibialis anterior in the stance and swing stance decreased as well During running, orthotics showed positive result in foot comfort. The foot comfort related to decreased stress, muscle activity, and foot arch strain. Overall comfort and the adequate decrease of muscle activity were associated with injury prevention and the best method to prevent injury semms to be the maintenance of foot comfort.

A STUDY OF BRACKET BASE (IN-AND-OUT) IN KOREAN (한국인(韓國人)의 Bracket base (in-and-out) 에 관(關)한 연구(硏究))

  • Yang, Jae-Woo;Lee, Dong Joo
    • The korean journal of orthodontics
    • /
    • v.20 no.2
    • /
    • pp.355-361
    • /
    • 1990
  • This study was undertaken to finish the design of the adequate preadjusted bracket in Korean. The labio-lingual & bucco-lingual width of tooth & in-and-out of the bracket base was studied in normal occlusion of 17 males & 17 females. The following results were obtained. 1. The in-and-outs of the bracket base in Korean were obtained (table 2). 2. The in-and-outs of the premolar & molar were no significant due to variation according to arch wire shape in clinical practice, so the more adjustment of arch wire was required. 3. The more amount of offset was required at lateral-canine offset than at central-lateral offset in 1st order bending, due to difference of the in-and-out. 4. The degrees of the anti-rotation in molar were obtained (table 3).

  • PDF

THE STUDY ON THE RELATIONSHIP BETWEEN IMAGE LAYER AND IMAGE PRODUCTION OF THE ORTHOPANTOMOGRAPH. (ORTHOPANTOMOGRAPH에서 IMAGE LAYER와 상조성 관계에 대한 연구)

  • Lee Kee Taek
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.6 no.1
    • /
    • pp.39-44
    • /
    • 1976
  • The study was performed in order to avoid misunderstanding of the image production in the orthopantomograph and auther tried artificially, the object was not placed on the image layer children who was in mixed dentition was taken with 3 sheets of the film at one time. The results were obtained as following; 1. If the object was placed in front of the image layer and back of it, width of the anterior teeth was narrowed and widened. 2. If the object's midline was not placed on the median line of the equipment, the one side was narrowed and the another side was widened. 3. If the head was inclined upward and downward, the former was shown V shape and the latter was shown inverted V shape outline of the arches. 4. In mixed dentition, auther obtained in each other that the image layer was placed on the deciduous arch, on the permanent arch, in the middle of the deciduous teeth and permanent teeth at one exposure.

  • PDF

Development of Dental Scanning System and Reproduction of Adjustable Upper Dental Impression Tray (치과용 스캐닝 시스템의 개발과 가변형 상악용 트레이의 재현성)

  • Cha, Young-Youp;Eom, Sang-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.16 no.3
    • /
    • pp.300-304
    • /
    • 2010
  • This study was performed to development a dental three-dimensional laser scanning system and measure the accuracy of new adjustable upper dental impression tray. The metal stock, individual, and new adjustable stock trays were used for 30 stone casts(10 casts each) duplicated a resin master model of maxilla. The dental stone was poured in a vinyl polysiloxane impressions and allowed to set for on hour. The master model and the duplicated casts were digitized using an dental scanning system. The distance between the reference points were measured and analyzed on the graphic image of 3D graphic software of CATIA. The statistical significance of the differences between the groups was determined by a two-way ANOVA. There were no significant differences between the accuracies of the adjustable stock tray and the master model except only anterior arch width on the upper arch. The adjustable upper stock tray showed clinically acceptable accuracies of the study cast produced by them.

The effect of bracket width on frictional force between bracket and arch wire during sliding tooth movement (치아의 활주 이동시 브라켓 폭이 브라켓과 호선 사이의 마찰력에 미치는 효과)

  • Choi, Won-Cheul;Kim, Tae-Woo;Park, Joo-Young;Kwak, Jae-Hyuk;Na, Hyo-Jeong;Park, Du-Nam
    • The korean journal of orthodontics
    • /
    • v.34 no.3 s.104
    • /
    • pp.253-260
    • /
    • 2004
  • Frictional force between the orthodontic bracket and arch wire during sliding tooth movement is related to many factors, such as the size, shape and material of both the bracket and wire, ligation method and the angle formed between the bracket and wire. There have been clear conclusions drawn in regard to most of these factors, but as to the effect of bracket width on frictional force there are only conflicting studies. This study was designed to investigate the effect of bracket width on the amount of frictional forces generated during clinically simulated tooth movement. Three different widths of brackets $(0.018{\times}0.025'\;standard)$ narrow (2.40mm), medium (3.00mm) and wide (4.25mm) were used in tandem with $0.016{\times}0.022'$ stainless steel wire. Three bracket-arch wire combinations were drawn on for 4 minutes on a testing apparatus with a head speed of 0.5mm/min and tested 7 times each. To reproduce biological conditions, dentoalveolar models were designed with indirect technique using a material with similar elastic properties as periodontal ligament (PDL). In addition, to minimize the effect of ligation force, elastomer was used with added resin, which was attached to the bracket to make up for the discrepancies of bracket width. The results were as follows: 1. Maximum frictional force for each bracket-arch wire combination was: Narrow (2.40mm): $68.09\pm4.69gmf$ Medium (3.00mm): $72.75\pm4.98 gmf$ Wide (4.25mm): $72.59\pm4.54gmf$ 2. Frictional force was increased with more displacement of wire through the bracket slot. 3. The ANOVA psot-hoc test showed that the bracker width had no significant effect on frictional force when tested under clinically simulated conditions(p>0.05).

The Effect of Lumbar Stabilization Exercises on an Acute Lower Back Pain Reduction (요부 안정화 운동이 급성기 요통 경감에 미치는 영향)

  • Kang, Kyung-Hwa;Kim, Dong-Uk;Kim, Mi-Jung;Mun, Hyun-Ju;Park, Yung-Hui;Park, Sun-Duck;Kim, Suhn-Yeop
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.10 no.1
    • /
    • pp.67-81
    • /
    • 2004
  • The purpose of this study was to investigate between low back pain scale and disability index owing to gait pattern. For the period of February 1 to February 29, 2004, we had conducted a questionnaire and direct interview with 100 persons lived in Daejeon. The result were as follows: 1. The stride length of experimental group, the male was $49.9{\pm}12.9cm$, the female $45.7{\pm}12.9cm$ and the width of feet. the male was $13.5{\pm}5.7cm$, the female $12.2{\pm}4.8cm$. 2. The Fick angle of all subjects was showed in external disposition, the left angle showed in asymmetry, the male was $11.0{\pm}5.7^{\circ}$, the female $8.5{\pm}1.3^{\circ}$. 3. The foot arch was similar to sex as a weight bearing and non-weight bearing, the male was $1.3{\pm}0.8cm$, the female $1.3{\pm}0.9cm$. 4. The impedimental index according to back pain grade, men was a lower than women, the male was $5.7{\pm}6.9$ and the female $7.2{\pm}5.3$. 5. The relation to difference between foot arch and disability index according to back pain grade as a weight bearing and non-weight bearing, the higher foot arch, the higher back pain grade was statistically significance(p<.05). 6. The relation between width of feet and disability index according to back pain grade, the wider width of feet, the higher back pain grade was statistically significance(p<.01). 7. The relation between stride length and disability index according to back pain grade, the wider stride length, the higher back pain grade was statistically significance (p<.05).

  • PDF

Development of Structural Model and Analysis of Design Factors for Small Greenhouse of Urban Agriculture (도시농업을 위한 소형온실 설계요인 분석 및 구조모델 개발)

  • Kim, Hyung-Kweon;Ryou, Young-Sun;Kim, Young-Hwa;Lee, Tae-Seok;Oh, Sung-Sik;Lee, Won-Suk;Kim, Yong-Hyeon
    • Journal of Bio-Environment Control
    • /
    • v.28 no.4
    • /
    • pp.388-395
    • /
    • 2019
  • The purpose of this study is to suggest structural model and analyze design factors for the development of small greenhouse standardization model. The average dimensions of small greenhouse desired by urban farmers were 3.3m in width, 1.9m in eaves height, 2.7m in ridge height, 5.7m in length. The cladding materials for small greenhouse were preferred to glass, PC board and plastic film, framework to aluminum alloy and steel, and heating method in electrical energy. In addition, it was analyzed that small greenhouses need to develop structural model by dividing them into entry-level type and high-level type. The roof type that was used for entry-level type was arch shape, framework was steel pipe, cladding material was plastic film. On the other hand, high-level type was used in even span or dutch light type, framework with square hollow steel, cladding materials with glass or PC board. In consideration of these findings and practicality, this study developed four types of small greenhouses. The width, eaves height, ridges height, and length of the small greenhouses of even span type, which were covered with 5mm thick glass and 6mm thick PC board were 3m, 2.2m, 2.9m, and 6m, respectively. The small greenhouse of dutch light type covered with 5mm thick glass was designed with 3.8m in with, 2.2m in eaves height, 2.9m in ridges height, and 6m in length. The width, eaves height, ridges height, and length of the arch shape small greenhouse covered with a 0.15mm PO film were 3m, 1.5m, 2.8m, and 6m, respectively.

Full-Scale Test on Precast Concrete Arch Bridge with Reinforced Joint and Backfill (보강된 이음부와 뒤채움을 적용한 조립식 프리캐스트 콘크리트 아치교량의 실물모형실험)

  • Chung, Chulhun;Joo, Sanghoon;Choi, Dongchan;Lee, Jongyun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.2
    • /
    • pp.389-402
    • /
    • 2014
  • In this paper, the load test of full-scale precast concrete arch bridges considering reinforced joint and backfill was conducted. It is an improved method that the reinforced joint enhanced the structural performance of conventional masonry arch system which was proposed by previous researchers. The models of full-scale test are $10m(span){\times}3m$ (rise) and $10m(span){\times}2m$ (rise), which are 2 meters in width. The critical load position was shown at a third-span from the results of the pre-analysis. Based on the this results, the positions of load, measuring items and points were determined in experiments. As a result, the maximum load capacity of the specimen $10m{\times}2m$, a relatively small rise to span ratio (compared to the specimen $10m{\times}3m$), was higher than the specimen $10m{\times}3m$. It was evaluated that all the specimens have sufficient structural performance on the design load.