• Title/Summary/Keyword: Arch support

Search Result 142, Processing Time 0.029 seconds

Does matching relation exist between the length and the tilting angle of terminal implants in the all-on-four protocol? stress distributions by 3D finite element analysis

  • Li, Xiaomei;Cao, Zhizhong;Qiu, Xiaoqian;Tang, Zhen;Gong, Lulu;Wang, Dalin
    • The Journal of Advanced Prosthodontics
    • /
    • v.7 no.3
    • /
    • pp.240-248
    • /
    • 2015
  • PURPOSE. To explore whether there is matching relation between the length and the tilting angle of terminal implants in the All-on-Four protocol by studying the effects of different implant configurations on stress distributions of implant, bone, and framework. MATERIALS AND METHODS. Four implants were employed to support a full-arch fixed prosthesis and five three-dimensional finite element models were established with CT images, based on the length (S and L) and distal tilt angle ($0^{\circ}$, $30^{\circ}$ and $45^{\circ}$) of terminal implants for an edentulous mandible, which named: Tilt0-S, Tilt30-S, Tilt30-L, Tilt45-S and Tilt45-L. An oblique 240 N was loaded at second molar. The von Mises Stresses were analyzed. The implants were consecutively named #1 to #4 from the loading point. RESULTS. 1) Tilt0-S had the greatest stress on the implants, with the other groups exhibiting variable reductions; the four implants of Tilt45-L demonstrated the greatest reduction in stress. 2) Tilt0-S had the greatest stress at bone around #1 implant neck, and Tilt45-L exhibited the least stress, which was a 36.3% reduction compared to Tilt0-S. 3) The greatest stress in the framework was found on the cantilevers distal to #1 implant. Tilt45-S exhibited the least stress. CONCLUSION. Matching different length and tilting angle of the terminal implants led to variable stress reductions on implants, bone and the superstructure. By optimizing implant configuration, the reduction of stress on implants and surrounding bone could be maximized. Under the present condition, Tilt45-L was the preferred configuration. Further clinical testings are required.

New virtual orthodontic treatment system for indirect bonding using the stereolithographic technique

  • Son, Kyoung-Hoi;Park, Jae-Woo;Lee, Dong-Keun;Kim, Ki-Dal;Baek, Seung-Hak
    • The korean journal of orthodontics
    • /
    • v.41 no.2
    • /
    • pp.138-146
    • /
    • 2011
  • The purpose of this article is to introduce a new virtual orthodontic treatment (VOT) system, which can be used to construct three-dimensional (3D) virtual models, establish a 3D virtual setup, enable the placement of the virtual brackets at the predetermined position, and fabricate the transfer jig with a customized bracket base for indirect bonding (IDB) using the stereolithographic technique. A 26-year-old woman presented with anterior openbite, crowding in the upper and lower arches, and narrow and tapered upper arch, despite having an acceptable profile and balanced facial proportion. The treatment plan was rapid palatal expansion (RPE) without extraction. After 10 days of RPE, sufficient space was obtained for decrowding. After a 10-week retention period, accurate pretreatment plaster models were obtained using silicone rubber impression. IDB was performed according to the protocol of the VOT system. Crowding of the upper and lower arches was effectively resolved, and anterior openbite was corrected to normal overbite. Superimposition of the 3D virtual setup models (3D-VSM) and post-treatment 3D virtual models showed that the latter deviated only slightly from the former. Thus, the use of the VOT system helped obtain an acceptable outcome in this case of mild crowding treated without extraction. More cases should be treated using this system, and the pre- and post-treatment virtual models should be compared to obtain feedback regarding the procedure; this will support doctors and dental laboratory technicians during the learning curve.

Treatment of Transposition of the Maxillary Canine Using Various Treatment Modalities (다양한 치료법을 사용한 상악 견치 전위의 치료)

  • Kim, Hyosun;Kim, Yoojun;Jang, Kitaeg;Kim, Youngjae
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.41 no.1
    • /
    • pp.54-63
    • /
    • 2014
  • Transposition is a unique and extreme form of ectopic eruption where a tooth develops and erupts in a position, normally occupied by an adjacent tooth. Generally, three treatment options are available when the maxillary canine and first premolar are transposed. In the first treatment option, the transposed position of the teeth can be maintained such that the first premolar is moved to the position of the canine. Second, extraction of the maxillary first premolar can be considered. Third, the position of the transposed teeth can be corrected such that their normal positions in the arch are restored. Factors that should be considered in treatment modality decision include function, occlusion, periodontal support, treatment time, patient cooperation, and esthetic demands. This report describes cases of maxillary canine-premolar transposition treated with each of the three aforementioned treatment options. In the first case, transposed teeth were arranged in their transposed position. The second case was an extraction case. In the third case, orthodontic treatment and surgical repositioning were conducted.

A COMPARISON OF THE MASTICATORY FUNCTION BETWEEN TWO DIFFERENT TYPES OF IMPLANT SUPPORTED PROSTHESES AND COMPLETE DENTURE FOR FULLY EDENTULOUS PATIENTS

  • Lee, Jae-Hoon;Kim, Woo-Hyun;Shin, Rie-Hye;Lee, Keun-Woo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.46 no.6
    • /
    • pp.591-601
    • /
    • 2008
  • STATEMENT OF PROBLEM: The improvement in oral function and comfort from the dental implant appears to depend on the particular type of implant support used with the denture. The number and positioning of implants have an influence on the force transfer and subsequent stress distribution around implants. Nevertheless, a quantitative comparison has not been made between the types of implant prosthesis used with different materials compared to conventional complete denture. PURPOSE: The objective of this study is to assess the masticatory performance, bite force and impact of two different type of implant supported prostheses on oral health-related quality of life compared to conventional complete denture with GOHAI, validated oral-specific health status measures, the sieving method, and the Prescale Dental System. MATERIAL AND METHODS: From the years 1999 to 2006, a total of 30 completely edentulous patients in a single arch were selected from the Yonsei University Dental Hospital, Department of Prosthodontics and Implant Clinic in Seoul, S. Korea. Patients were divided into 3 groups of 10 each. Group HR was restored with fixed-detachable hybrid prostheses with resin teeth. Group FP had fixed dentures with porcelain teeth while Group CD had a complete denture. The masticatory performance was compared between 3 groups. RESULTS: The results showed a significant improvement in oral health-related quality of life with dental implants compared to a conventional denture in GOHAI comparison. Overall, implant prostheses showed a higher masticatory performance ($S_{50}$) and maximum bite force compared with conventional dentures (P < .05) but no differences between different implant supported prostheses (P > .05). CONCLUSION: Within the limitation of this study, the numbers of implant and material of implant prostheses does not appear to impact patient satisfaction, masticatory performance or bite force.

Implant supported fixed prosthesis for complete edentulous maxilla with severe alveolar ridge resorption: A case report (치조골 흡수가 심한 상악 완전 무치악 환자에서 임플란트 고정성 보철물을 이용한 수복 증례)

  • Choi, Yoon-Ji;Lee, Ji-Hyoun;Jhin, Min-Ju
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.2
    • /
    • pp.152-159
    • /
    • 2016
  • Implant fixed prosthesis for the complete edentulous maxilla provides significant benefits in the aspects of functions and esthetics compared with the conventional denture. Implant supported fixed prosthesis are totally supported by implant, and thus stabilizes the prosthesis to the maximum degree as possible. Also, the improved retention and stability of fixed prosthesis enhance patients' psychological and psychosocial health. This clinical presentation describes a maxillary full arch implant-supported fixed prosthesis in complete maxillary edentulous patient who showed vertical and horizontal alveolar bone resorption in the anterior ridge. To rehabilitate the esthetics and proper lip support, the zirconia framework was fabricated and the pink porcelain was veneered to reproduce the natural gingival tissue. After 9 months of follow up, the restorations were maintained without complications and the patient was satisfied with the restoration both functionally and esthetically.

Dynamic Reconstruction with Temporalis Muscle Transfer in Mobius Syndrome (뫼비우스 증후군에서 측두근 전위술을 이용한 역동적 재건)

  • Kim, Baek Kyu;Lee, Yoon Ho
    • Archives of Plastic Surgery
    • /
    • v.34 no.3
    • /
    • pp.325-329
    • /
    • 2007
  • Purpose: Mobius syndrome is a rare congenital disorder characterized by facial diplegia and bilateral abducens palsy, which occasionally combines with other cranial nerve dysfunction. The inability to show happiness, sadness or anger by facial expression frequently results in social dysfunction. The classic concept of cross facial nerve grafting and free muscle transplantation, which is standard in unilateral developmental facial palsy, cannot be used in these patients without special consideration. Our experience in the treatment of three patients with this syndrome using transfer of muscles innervated by trigeminal nerve showed rewarding results. Methods: We used bilateral temporalis muscle elevated from the bony temporal fossa. Muscles and their attached fascia were folded down over the anterior surface of the zygomatic arch. The divided strips from the attached fascia were passed subcutaneously and anchored to the medial canthus and the nasolabial crease for smiling and competence of mouth and eyelids. For the recent 13 years the authors applied this method in 3 Mobius syndrome cases- 45 year-old man and 13 year-old boy, 8 year-old girl. Results: One month after the surgery the patients had good support and already showed voluntary movement at the corner of their mouth. They showed full closure of both eyelids. There was no scleral showing during eyelid closure. Also full closure of the mouth was achieved. After six months, the reconstructed movements of face were maintained. Conclusion: Temporalis muscle transfer for Mobius syndrome is an excellent method for bilateral reconstruction at one stage, is easy to perform, and has a wide range of reconstruction and reproducibility.

Nostril Base Augmentation Effect of Alveolar Bone Graft

  • Lee, Woojin;Park, Hyung Joon;Choi, Hyun Gon;Shin, Dong Hyeok;Uhm, Ki Il
    • Archives of Plastic Surgery
    • /
    • v.40 no.5
    • /
    • pp.542-545
    • /
    • 2013
  • Background The aims of alveolar bone grafting are closure of the fistula, stabilization of the maxillary arch, support for the roots of the teeth adjacent to the cleft on each side. We observed nostril base augmentation in patients with alveolar clefts after alveolar bone grafting. The purpose of this study was to evaluate the nostril base augmentation effect of secondary alveolar bone grafting in patients with unilateral alveolar cleft. Methods Records of 15 children with alveolar clefts who underwent secondary alveolar bone grafting with autogenous iliac cancellous bone between March of 2011 and May of 2012 were reviewed. Preoperative and postoperative worm's-eye view photographs and reconstructed three-dimensional computed tomography (CT) scans were used for photogrammetry. The depression of the nostril base and thickness of the philtrum on the cleft side were measured in comparison to the normal side. The depression of the cleft side pyriform aperture was measured in comparison to the normal side on reconstructed three-dimensional CT. Results Significant changes were seen in the nostril base (P=0.005), the philtrum length (P=0.013), and the angle (P=0.006). The CT measurements showed significant changes in the pyriform aperture (P<0.001) and the angle (P<0.001). Conclusions An alveolar bone graft not only fills the gap in the alveolar process but also augments the nostril base after surgery. In this study, only an alveolar bone graft was performed to prevent bias from other procedures. Nostril base augmentation can be achieved by performing alveolar bone grafts in children, in whom invasive methods are not advised.

A STUDY ON THE OSSEOINTEGRATED PROSTESIS USING THREE DIMENSIONAL FINITE ELEMENT METHOD (골유착성 보철물에 관한 삼차원 유한요소분석적 연구)

  • Kim, Dong-Won;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.1
    • /
    • pp.167-213
    • /
    • 1991
  • The successful replacement of missing teeth has been one driving aim behind the emergence of implant dentistry as both a technology and clinical vocation for over four decades. To date, a multitude of dental implant devices had been designed and utilized in the patient population. Most of these devices have been designed without support of the engineering criteria. The long-term success of any dental implant is dependent upon the optimization of stresses which occurs during oral function and parafunction. Although many studies have examined the biologic interactions between dental implants and living tissue, few studies have been reported on the biomechanical aspects of dental implants. The purpose of this study was to analyze the stress distribution of osseointegrated prosthesis on certain conditions, such as amount of load, location of load, length of fixtures, number of fixtures used, arch shape, bone quality, etc. Three dimentional finite element analysis was used for this study. FEM models were created using commercial software(Super SAP. for IBM 16 bit AT computer. All elements were 8-node brick, isoparametric. Mandible and prosthesis was modeled with 780 elements and 1074 nodes. The results were as follows : 1. In case of cantilever extension, there was a compressive stress at the base of the first implant and a tensile stress at the base of the second implant. 2. The stresses were linearly proportional to the amount of load. 3. The stresses were linearly proportional to the length of cantilever. 4. There was a stress concentration at the neck of the implant and bone under horizontal loads.

  • PDF

Does the prosthesis weight matter? 3D finite element analysis of a fixed implant-supported prosthesis at different weights and implant numbers

  • Tribst, Joao Paulo Mendes;Dal Piva, Amanda Maria de Oliveira;Borges, Alexandre Luiz Souto;Rodrigues, Vinicius Aneas;Bottino, Marco Antonio;Kleverlaan, Cornelis Johannes
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.2
    • /
    • pp.67-74
    • /
    • 2020
  • PURPOSE. This study evaluated the influence of prosthesis weight and number of implants on the bone tissue microstrain. MATERIALS AND METHODS. Fifteen (15) fixed full-arch implant-supported prosthesis designs were created using a modeling software with different numbers of implants (4, 6, or 8) and prosthesis weights (10, 15, 20, 40, or 60 g). Each solid was imported to the computer aided engineering software and tetrahedral elements formed the mesh. The material properties were assigned to each solid with isotropic and homogeneous behavior. The friction coefficient was set as 0.3 between all the metallic interfaces, 0.65 for the cortical bone-implant interface, and 0.77 for the cancellous bone-implant interface. The standard earth gravity was defined along the Z-axis and the bone was fixed. The resulting equivalent strain was assumed as failure criteria. RESULTS. The prosthesis weight was related to the bone strain. The more implants installed, the less the amount of strain generated in the bone. The most critical situation was the use of a 60 g prosthesis supported by 4 implants with the largest calculated magnitude of 39.9 mm/mm, thereby suggesting that there was no group able to induce bone remodeling simply due to the prosthesis weight. CONCLUSION. Heavier prostheses under the effect of gravity force are related to more strain being generated around the implants. Installing more implants to support the prosthesis enables attenuating the effects observed in the bone. The simulated prostheses were not able to generate harmful values of peri-implant bone strain.

Methodology for Near-miss Identification between Earthwork Equipment and Workers using Image Analysis (영상분석기법을 활용한 토공 장비 및 작업자간 아차사고식별 방법론)

  • Lim, Tae-Kyung;Choi, Byoung-Yoon;Lee, Dong-Eun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.4
    • /
    • pp.69-76
    • /
    • 2019
  • This paper presents a method that identifies the unsafe behaviors at the level of near-misses using image analysis. The method establishes potential collision hazardous area in earthmoving operation. It is implemented using a game engine to reproduce the dangerous events that have been accepted as major difficulty in utilizing computer vision technology to support construction safety management. The method keeps realistically track of the ever-changing hazardous area by reflecting the volatile field conditions. The method opens a way to distinguish unsafe conditions and unsafe behaviors that have been overlooked in previous studies, and reflects the causal relationship which causes an accident. The case study demonstrate how to identify the unsafe behavior of a worker exposed to an unsafe area created by dump trucks at the level of near-misses and to determine the hazardous areas.