• 제목/요약/키워드: ArcA

검색결과 4,492건 처리시간 0.046초

주파수 분석을 이용한 태양광 설비의 아크 검출 기법 (Arc Detection Method of Photovoltaic System using Frequency Analysis)

  • 김상규;지평식
    • 전기학회논문지P
    • /
    • 제66권3호
    • /
    • pp.144-149
    • /
    • 2017
  • There is a little research on DC arc detection when compared to a large number of literature and patents on AC arc detection. However, as DC energy sources such as photovoltaic power generation facilities and fuel cells are introduced, research on DC arc has become as important as AC arc detection in terms of circuit protection and system reliability enhancement. In this paper, we have developed an arc detection method for photovoltaic system using frequency analysis. Through various experiments, it was confirmed that the proposed method effectively detects the arc.

아크주에 작용하는 자기구동력에 의한 아크 거동의 변화 (The Change in Arc Behavior by magnetic driving force acting on Arc Column)

  • 조현길;이은웅;김준호;정종호;김일중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.797-798
    • /
    • 2006
  • To investigate a arc behavior when the flux density linking arc current is different, two kinds of models having the different flux density with each other are proposed. Calculations of the flux density and the electromagnetic force acting on arc column using finite element method is described in this paper. And, arc behavior photographs by the high speed camera are illustrated at breaking DC 100V, 100A on the resistance load. So, the arc driving forces are compared with according to the arc types.

  • PDF

고역통과 필터 및 FFT를 이용하여 아크감지 알고리즘 검증 (Verification of Algorithm for Arc Detection Using High Pass Filter and FFT)

  • 윤민호;조유정;김경탁;임성훈
    • 한국전기전자재료학회논문지
    • /
    • 제36권5호
    • /
    • pp.520-524
    • /
    • 2023
  • An algorithm was developed to detect and block serial arc currents using HPF. The AC series arc problem is that the load current is greater than the fault current and no leakage current occurs. As a solution, an arc detection method utilizing differences in high- frequency amplitudes was developed. HPT was applied to the load current and FFT was applied to eliminate low frequencies. An algorithm has been developed to detect arc waveforms when they exceed a certain value compared to the average of normal waveforms. Using one cycle of data, arc detection is faster and arc accidents are prevented.

Comparison study of intensity modulated arc therapy using single or multiple arcs to intensity modulated radiation therapy for high-risk prostate cancer

  • Ashamalla, Hani;Tejwani, Ajay;Parameritis, Ioannis;Swamy, Uma;Luo, Pei Ching;Guirguis, Adel;Lavaf, Amir
    • Radiation Oncology Journal
    • /
    • 제31권2호
    • /
    • pp.104-110
    • /
    • 2013
  • Purpose: Intensity modulated arc therapy (IMAT) is a form of intensity modulated radiation therapy (IMRT) that delivers dose in single or multiple arcs. We compared IMRT plans versus single-arc field (1ARC) and multi-arc fields (3ARC) IMAT plans in high-risk prostate cancer. Materials and Methods: Sixteen patients were studied. Prostate ($PTV_P$), right pelvic ($PTV_{RtLN}$) and left pelvic lymph nodes ($PTV_{LtLN}$), and organs at risk were contoured. $PTV_P$, $PTV_{RtLN}$, and $PTV_{LtLN}$ received 50.40 Gy followed by a boost to $PTV_B$ of 28.80 Gy. Three plans were per patient generated: IMRT, 1ARC, and 3ARC. We recorded the dose to the PTV, the mean dose ($D_{MEAN}$) to the organs at risk, and volume covered by the 50% isodose. Efficiency was evaluated by monitor units (MU) and beam on time (BOT). Conformity index (CI), Paddick gradient index, and homogeneity index (HI) were also calculated. Results: Average Radiation Therapy Oncology Group CI was 1.17, 1.20, and 1.15 for IMRT, 1ARC, and 3ARC, respectively. The plans' HI were within 1% of each other. The $D_{MEAN}$ of bladder was within 2% of each other. The rectum $D_{MEAN}$ in IMRT plans was 10% lower dose than the arc plans (p < 0.0001). The GI of the 3ARC was superior to IMRT by 27.4% (p = 0.006). The average MU was highest in the IMRT plans (1686) versus 1ARC (575) versus 3ARC (1079). The average BOT was 6 minutes for IMRT compared to 1.3 and 2.9 for 1ARC and 3ARC IMAT (p < 0.05). Conclusion: For high-risk prostate cancer, IMAT may offer a favorable dose gradient profile, conformity, MU and BOT compared to IMRT.

GTA용접용 텅스텐 전극팁의 형상과 연마 상태가 아크특성에 미치는 영향 (The Effect of Configuration and Surface Polishing in Tungsten Electrode Tip for Gas Tungsten Arc Welding on the Arc Characteristics)

  • 조상명;서상균
    • Journal of Welding and Joining
    • /
    • 제19권1호
    • /
    • pp.33-39
    • /
    • 2001
  • The welding quality by Gas Tungsten Arc Welding shows very high level, but the welding speed is lower than that of gas metal arc welding. Also, the welding quality by automatic GTAW is variable as the arc characteristics is changed by the consumption of electrode tip. The purpose of this study is to investigate the relation between the properties of tungsten electrode tip and the various arc characteristics at high current region. In this study, the high welding current 200A was applied to the repeated arc start test and long term arcing test using the $\phi$3.2 tungsten electrodes with cone angle 30$^{\circ}$, 45$^{\circ}$, 60$^{\circ}$sharp tip, and 60$^{\circ}$surface polished (S.P.) sharp tip. It was confirmed that the maximum arc pressure by the initial electrode condition was highest in 45$^{\circ}$sharp tip, and the next in 60$^{\circ}$sharp tip, the last was in 30$^{\circ}$sharp tip and 60$^{\circ}$S.P.. But, the maximum arc pressure after the repeated arc start test and long term arcing test was decreased considerably. But, the maximum arc pressure was highest also in 45$^{\circ}$ sharp tip after the tests, the next was in 30$^{\circ}$sharp tip, and the last was in 60$^{\circ}$sharp tip and 60$^{\circ}$S.P.. The arc start characteristics was the most excellent in 60$^{\circ}$S.P., By long term arcing test, the lanthania included in tungsten electrode was extinguished at tip surface preferentially, therefore the arc characteristics of electrode tip got worse.

  • PDF

Mash-up 분석기술 기반의 아크 고장 검출 알고리즘에 관한 연구 (A Study on Arc Fault Detection Algorithm Based on Mash-up Analysis Technique)

  • 이기연;문현욱;김동우;임용배;최종수
    • 전기학회논문지
    • /
    • 제66권6호
    • /
    • pp.995-1000
    • /
    • 2017
  • In this paper, we present an electrical arc detection algorithm using the mash-up analysis technique which is the core technology for the autonomous electrical safety management system(AESMS) of the multi-unit dwellings. The mash-up analysis technique analyzes the voltage, load current, zero phase current data simultaneously to judge arc faults. In order to develop the arc fault detection algorithm, the characteristics of series arc and parallel arc were analyzed. Also, we propose the mash-up analysis technique that analyzes waveforms of voltage, load current, and zero phase current at the same time. The arc fault detection algorithm was developed using the mash-up analysis technique. The developed algorithm can prevent electrical disasters in an effective way through accident prediction, and it will be used as a basic technology to introduce an autonomous electrical safety management system.

군용 섬유제품의 일광견뢰도 시험방법 개선에 대한 연구 (A Study on the Improved Lightfastness Test Method for Military Textile Products)

  • 홍성돈;김병순;전영민;이정순
    • 한국염색가공학회지
    • /
    • 제27권4호
    • /
    • pp.288-300
    • /
    • 2015
  • This study was executed to substitute Carbon-arc method, which is a method currently used for testing light-fastness of military textile products, with Xenon arc method. Specimens used in the study were classified according to the fabric material and color of military textile products and were composed of 11 items of 42 kinds with different colors. Light-fatness test was done by comparing the result of Carbon-arc(KS K 0700) and Xenon arc(KS K ISO 105-B02) method. In Xenon arc method, blue wool reference materials of 1~8 was used, and exposure condition preferred in American continent and light exposure method 3 were applied. After testing with both methods, grade of light-fastness, color difference, reflectance and color were examined. Even though there was a slight difference among 42 specimens used in the test, results exceeded the quality standard both in Carbon-arc-lamp and Xenon arc-lamp. Therefore, it was confirmed that applying KS K ISO 105-B02 together in the KS K 0700-regulated Ministry of National Defense standard and purchase order would also fit.

탠덤형 자석 소호기를 사용한 760V급 직류 개폐기의 차단 특성 (760 V-Class DC Switch Breaking Characteristics Using Tandem Type Magnet Extinguisher)

  • 김효성
    • 전력전자학회논문지
    • /
    • 제27권3호
    • /
    • pp.175-179
    • /
    • 2022
  • Magnetic arc extinguishing technology is effective as an extinguishing device for low-voltage direct current (DC) circuit breakers with a resistive load of ≤4 kW. The separation distance between the magnet and the electrical contact must be shortened to increase the magnetic arc extinguishing force. However, if the magnet is installed too close to the electrical contact points, the magnet is exposed to high temperatures due to the arc current generated when the load current is cut off and the magnetism is lost. To solve this problem, the effective magnetic flux density at the electrical contact can be maintained high by placing the arc extinguishing magnet in a tandem structure with the electrical contact point between them, and the proper separation distance between the contact points and the magnet can be maintained. In addition, an electric arc extinguishing technology that emits arc energy using a series circuit of diode and resistor is used to suppress the continuous arc voltage generated by the inductive load. For the proposed circuit breaker, the breaking characteristics are analyzed through the breaking test for the DC load of the 760 V level, the load power of 4 kW, and the time constant of 5 ms, and an appropriate arc extinguishing design guideline is proposed.

기중 아크 차단에 대한 접점 및 소호 재료의 영향 (Influence of Contact and Wall Material on Arc Interruption in Air)

  • 이상엽;박홍태;오일성;이경행
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 C
    • /
    • pp.1637-1639
    • /
    • 2001
  • Air arc interruption used in low rated voltage breaker, ACB and MCCB, have used the arc chamber composed of metal plates and insulating laminates which supposed these mechanically. and geometry and materials of arc chamber are very different by breaker manufacturer. These breakers have required to be smaller and to interrupt higher current by user. therefore the arc chamber geometry and material in breaker have been small, complex and various. The purpose of this study is to examine the effects of insulating laminates and contact materials on air arc interruption. Contacts were surrounded by a rectangle chamber of insulating laminates. Contact concoctions were composed of AgW, AgCdO that have used in low rated voltage breaker, and insulating laminates were polyester, epoxy. We found strong dependance of arc voltage on insulating material. The ablated vapor on polyester increased arc voltage that was useful in air arc interruption.

  • PDF

직류 시스템에서의 아크 검출에 관한 연구 (A Study of Arc Detection at DC Power System)

  • 반기종;김진우;원영진;임승하
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2007년도 하계종합학술대회 논문집
    • /
    • pp.461-462
    • /
    • 2007
  • DC Arc is an electric discharge which is occurred in two oppolsite electrode when system operating with DC current appliance. In this paper, DC arc detection system is designed for the display of DC arc fault current which is occurred in the local electric network with DC Power. This DC arc is one of the main causes of electric fire of dc system. Arc fault in electrical network has the characteristics of low current, high impedance and low frequency. DC Arc current detection device is designed for the display of arc fault current which has the modified arc characteristics.

  • PDF