• Title/Summary/Keyword: Arc state

Search Result 233, Processing Time 0.032 seconds

축 방향 자기장애 의한 아크의 거동과 전극표면의 손상 (Arc behaviors and electrode surface damage under the axial magnetic field)

  • 조주현;최영욱;한용기;한현;권오경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.188-189
    • /
    • 2007
  • Axial magnetic field was applied into the hollow anode of plasma torch for the purpose of extension of electrode lifetime. The average arc voltage increased because the arc column became longer, the arc voltage ripple frequency became low. The steady state of arc voltage was removed by applied magnetic filed. The lifetime of electrode was over 1000 hours which is 100 times longer than operation without magnetic field.

  • PDF

인버터 아크 용접기의 파형제어기법 및 성능향상에 관한 연구 (A Study on Current Waveform Control and Performance Improvement for Inverter Arc Welding Machine)

  • 채영민;고재석;김진욱;이승요;최해룡;최규하
    • 전력전자학회논문지
    • /
    • 제4권2호
    • /
    • pp.128-137
    • /
    • 1999
  • 최근 전력전자기술 및 인버터 회로의 다양한 제어기법의 발달에 따라서 용접기 분야에서의 용접성능 향상에 관한 다양한 연구가 진행되고 있으며 특히{{{{ { CO}_{2 } }} 아크 용접기의 경우 용접성능을 좌우하는 스패터 발생을 최소화 하는 기법이 활발하게 연구되고 있다. 그러나 현재까지는 용접기의 출력전압을 정전압으로 제어하는 방식을 사용함에 따라 용접기의 금속이행과정을 임의로 제어하는 것이 불가능하였고, 특히 스패터가 다량으로 발생하는 저전류영역의 금속이행과정인 단락이행에서의 스패터 저감을 기대하기가 어려웠다. 따라서 본 논문에서는 마이크로프로세서를 이용한 인버터 출력전류의 파형제어기법을 사용하여 인버터 아크 용접기의 출력전류를 순시적으로 제어함에 의하여 스패터 저감, 단락주기의 안정화 및 순간단락현상 감소의 측면에서 용접성능을 개선위한 연구를 수행하였고 이상의 연구에 대한 결과를 제시하였고, 또한 인버터 아크 용접기의 AC/DC 전력변환장치로 SMR(Switched Mode Rectifier)를 사용하여 시스템을 단위역율로 운전하였으며 입력전류의 저차 고조파 억제효과를 얻을 수 있었다.

  • PDF

Spot-GTA 용접자세에 따른 304 스테인리스강 용융지 표면 및 용접부 형상 거동 (Behavior of Weld Pool Shape and Weld Surface Deformation as a Function of Spot-GTA Welding Position for 304 Stainless Steel)

  • 강남현;박영도;조경목
    • Journal of Welding and Joining
    • /
    • 제26권2호
    • /
    • pp.62-68
    • /
    • 2008
  • Effects of gravitational orientation on gas tungsten arc welding (GTAW) for 304 stainless steel were studied to determine the critical factors for weld pool formation, such as weld surface deformation and weld pool shape. This study was accomplished through an analytical study of weld pool stability as a function of primary welding parameters (arc current and arc holding time), material properties (surface tension and density), and melting efficiency (cross-sectional area). The stability of weld pool shape and weld surface deformation was confirmed experimentally by changing the welding position. The arc current and translational velocity were the major factors in determining the weld pool stability as a function of the gravitational orientation. A 200A spot GTAW showed a significant variation of the weld pool formation as the arc held longer than 3 seconds, however the weld pool shape and surface morphology for a 165A spot GTAW were 'stable', i.e., constant regardless of the gravitational orientation. The cross-sectional area of the weld (CSA) was one of the critical factors in determining the weld pool stability. The measured CSA ($13.5mm^2$) for the 200A spot GTAW showed a good agreement with the calculated CSA ($14.9mm^2$).

혼합필터와 주파수분석기법을 이용한 교류 아크 검출 기법 (AC Arc Detection Method using Mixed Filter and Frequency Analysis)

  • 장동욱;박성희;이강원
    • 전기학회논문지P
    • /
    • 제66권4호
    • /
    • pp.200-205
    • /
    • 2017
  • In this paper, we propose a technique to determine the normal and arc of an alternating current using a mixed filter composed of an average filter and a band-pass filter and a frequency analysis. The proposed method uses the moving average filter of the FIR filter structure for noise removal and the band-pass filter of the IIR filter structure for detecting only specific frequency components after normalizing the measured current signal based on the maximum value. After performing Fast Fourier Transform (FFT) using the band-pass filtered signal, the total energy is calculated using the magnitude component of the frequency, and the arc is detected using the magnitude of the calculated energy. In order to show the validity of the proposed method, we experimented with various data and found that arc and steady state can be easily discriminated by calculating spectral energy. Therefore, it is considered that the proposed method can be applied to arc diagnosis of low voltage electric wire.

Low Speed Thrust Characteristics of a Modified Sonic Arc Airfoil Rotor through Spin Test Measurement

  • Lee, Jang-Chang
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제13권3호
    • /
    • pp.317-322
    • /
    • 2012
  • The low speed aerodynamic characteristics for a modified sonic arc airfoil which is designed by using the nose shape function of sonic arc, the shape function of NACA four-digit wing sections, and Maple are experimentally investigated. The small rotor blades of a modified sonic arc and NACA0012 airfoil are precisely fabricated with a commercially available light aluminum(Al 6061-T6) and are spin tested over a low speed range (3000rpm-5000rpm). In a consuming power comparison, the consuming powers of NACA0012 are higher than that of modified sonic arcs at each pitch angle. The measured rotor thrust for each pitch angle is used to estimate the rotor thrust coefficient according to momentum theory in the hover state. The value of thrust coefficients for both two airfoils at each pitch angle show almost constant values over the low Mach number range. However, the rotor thrust coefficient of NACA0012 is higher than that of the modified sonic arc at each pitch angle. In conclusion, the aerodynamic performance of NACA0012 is better than that of modified sonic arcs in the low speed regime. This test model will provide a convenient platform for improving the aerodynamic performance of small scale airfoils and for performing design optimization studies.

저압배선계통에서 직렬아크의 검출에 관한 연구 (A Study on the Series Arc Detection in Low-voltage Wiring Systems)

  • 김일권;박대원;최수연;박찬용;김황국;길경석
    • 한국전기전자재료학회논문지
    • /
    • 제21권2호
    • /
    • pp.182-187
    • /
    • 2008
  • This paper dealt with the detection algorithm of series arcing, which is a cause of electric fires in low-voltage wiring systems. To find the distinguished electrical features of series arc, we simulated series arcing by the arc generator specified in UL1699. An electric heater, an inverter-controlled vacuum cleaner, and a phase-controlled incandescent lamp were used as loads to generate series arcing. A high-pass filter (HPF) with the low cut-off frequency of 3 kHz at -3 dB was fabricated and applied to separate the series arc signal from the AC voltage source. The experiment showed that the high frequency signal generates randomly during series arcing, and the phase-controlled incandescent lamp produces high frequency pulses even in normal state. In this case, the magnitude, the width, and the randomness of high frequency signal should be analyzed to estimate series arcing precisely.

제어체적법에 의한 Ar 아크 플라즈마의 특성 계산 (Numerical calculations of characteristics of Argon arc plasma using the control volume method)

  • 김외동;고광철;강형부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1404-1406
    • /
    • 1995
  • In this paper, argon gas was used for numerical analysis of an arc in a cutting plasma torch driven by constant current. We established nozzle-constricting type torch domain and calculated steady state characteristics of argon arc plasma using the control volume method(CVM). For simplicity, we assumed that the flow field is laminar and the local thermodynamic equilibrium(LTE) prevails in all domain regions. We also neglected cathode-fall and anode-fall effects. Considering magnetic pinch effect and viscosity effect, we solved the momentum equation. Voltage drop in the arc column due to input current was calculated from the temperature field obtained by the energy balance equation.

  • PDF

플라즈마 키홀 박판 용접에서의 열 및 물질 유동 (Heat and mass flow in plasma arc keyhole-welding of thin plate)

  • 김원훈;나석주
    • 대한기계학회논문집
    • /
    • 제12권4호
    • /
    • pp.813-824
    • /
    • 1988
  • 본 연구에서는 플라즈마 키홀 용접 시의 열 및 물질 유동을 규명함으로써 용 접부 조직변화 예측과 더불어 용접부 형상설계, 열응력 계산 등의 기본자료를 제시하 여 전체적인 용접부 품질성능을 향상시키는데 목적이 있다.

Wear Behaviors of Ceramics TIN, TIC and TICN with Arc Ion Plating

  • Oh, Seong-Mo;Rhee, Bong-Goo;Jeong, Bong-Soo
    • Journal of Mechanical Science and Technology
    • /
    • 제17권12호
    • /
    • pp.1904-1911
    • /
    • 2003
  • In order to determine the wear properties of AIP (Arc Ion Plating) deposition, wear process was evaluated by using a Falex test machine. Also, in order to determine the effects of coating material on the wear process, TiC, TiN, and TiCN coatings of thickness about 5 $\mu\textrm{m}$∼6 $\mu\textrm{m}$ coated by Arc ion plating deposition method were tested. The wear property was determined under a dry sliding condition as a function of the applied load, sliding distance, sliding velocity and temperature. The results show that when wear of the coating-layer occurred, specific wear amount increased with the wear rate. At initial state, the wear rate rapidly increased, but it gradually reduced as the velocity increased. Also, when raising the temperature, the wear rate increased in the order of TiCN, TiN and TiC due to the frictional heat.

A Study on Medium Voltage Power Supply with Enhanced Ignition Characteristics for Plasma Torch

  • 정경섭;서용석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.242-243
    • /
    • 2010
  • This paper investigates a power supply of medium voltage with enhanced ignition characteristics for plasma torch. Series resonant half-bridge topology is presented to be a suitable ignition circuitry. The ignition circuitry is integrated into the main power conversion system of a multi-phase staggered three-level dc-dc converter with a diode front-end rectifier. The plasma torch rated for 3MW, 2kA and having the physical size of 1m long is selected to be a high enthalpy source in waste disposal system. The steady-state and transient operations of plasma torch are simulated. The parameters of Cassie-Mary arc model are calculated based on 3D magneto-hydrodynamic simulations. Circuit simulation waveform shows that the ripple of arc current can be maintained within ${\pm}10%$ of its rated value under the existence of load disturbance. This power conversion configuration provides high enough ignition voltage around 5KA during ignition phase and high arc stability under the existence of arc disturbance noise resulting in a high-performance plasma torch system.

  • PDF