• 제목/요약/키워드: Arc Stability

검색결과 220건 처리시간 0.026초

Stability of a magnetic structure producing an M6.5 flare in the active region 12371

  • Kang, Jihye;Inoue, Satoshi;Kusano, Kanya;Park, Sung-Hong;Moon, Yong-Jae
    • 천문학회보
    • /
    • 제44권1호
    • /
    • pp.83.2-83.2
    • /
    • 2019
  • We study the stability of the magnetic structure in active region (AR) 12371 producing an M6.5 flare on June 22 2015. We first perform a nonlinear force-free fields (NLFFFs) extrapolation to derive three-dimensional (3D) magnetic fields based on time series of observed photospheric magnetic fields. The NLFFFs well describe an observed sigmoidal structure with the shape of a double arc magnetic configuration. Next, we examine three possible instabilities (kink, torus, and double arc) to investigate how the M6.5 flare is triggered in the double arc loops. Consequently, the double arc loops are stable against kink and torus instabilities, but possibly unstable against the double arc instability before the flare occurrence. Finally, we discuss a probable scenario for the M6.5 flare.

  • PDF

피복성분에 의한 수중용접봉의 아크 안정성 개선에 관한 실험연구 (An Experimental Study on the Arc Stability Improvement of Underwater Wet Welding with Flux Ingredients)

  • 김복인;노창석;정교헌;김민남
    • 한국해양공학회지
    • /
    • 제15권4호
    • /
    • pp.73-79
    • /
    • 2001
  • Underwater wet bead-on-plate welds were experimentally performed on 11mm thick SS400 steel plate as base metal by using six different types of flux coated electrodes of 3.2mm diameter. Two kinds of different flux coated wet arc electrodes (UW-1, UW-2) were individually designed flux materials, three kinds of the electrodes (E4301, E4311, E4313) were terrestrial electrodes and the another one (TN20) was an imported underwater wet welding electrode. As results, the individually designed flux coated underwater electrode, UW-2 and TN20 had a good starting and the excellent arc stability compared with other electrodes. No significant difference of bead appearance could be detected, but the slag detachability of TN20 electrodes was relatively undesirable. By rapid cooling rate, the hardness value and the portion of martensite of HAZ were increased, but it was considerably maintain stable for TN20 and UW-2 electrodes. The individually designed flux coated electrode, UW-2 could be used in practice for underwater bead welds.

  • PDF

Spot-GTA 용접자세에 따른 304 스테인리스강 용융지 표면 및 용접부 형상 거동 (Behavior of Weld Pool Shape and Weld Surface Deformation as a Function of Spot-GTA Welding Position for 304 Stainless Steel)

  • 강남현;박영도;조경목
    • Journal of Welding and Joining
    • /
    • 제26권2호
    • /
    • pp.62-68
    • /
    • 2008
  • Effects of gravitational orientation on gas tungsten arc welding (GTAW) for 304 stainless steel were studied to determine the critical factors for weld pool formation, such as weld surface deformation and weld pool shape. This study was accomplished through an analytical study of weld pool stability as a function of primary welding parameters (arc current and arc holding time), material properties (surface tension and density), and melting efficiency (cross-sectional area). The stability of weld pool shape and weld surface deformation was confirmed experimentally by changing the welding position. The arc current and translational velocity were the major factors in determining the weld pool stability as a function of the gravitational orientation. A 200A spot GTAW showed a significant variation of the weld pool formation as the arc held longer than 3 seconds, however the weld pool shape and surface morphology for a 165A spot GTAW were 'stable', i.e., constant regardless of the gravitational orientation. The cross-sectional area of the weld (CSA) was one of the critical factors in determining the weld pool stability. The measured CSA ($13.5mm^2$) for the 200A spot GTAW showed a good agreement with the calculated CSA ($14.9mm^2$).

DSC, ARC, ISCO를 활용한 다양한 순도를 가진 AP의 장기 열적안정성 연구 (Study on the Long-term Thermal Stability by DSC & ARC and its ISCO behaviors with different AP Quality)

  • 김승희;권국태;이소정
    • 한국추진공학회지
    • /
    • 제22권2호
    • /
    • pp.59-65
    • /
    • 2018
  • AP(Ammonium Perchlorate, $NH_4ClO_4$)를 포함하는 복합화약조성의 등온가열시험시, 일정 순도 이하의 AP를 사용하는 경우 "bulged"현상으로 인해 등온가열시험 결과를 얻을 수 없었다. 본 연구는 품질 혹은 순도에 따른 AP의 열적 안정성 차이에 대해 규명하기 위해 LOT 별 AP에 대해 DSC 결과를 분석하고, 그 분석결과를 등온가열시험 결과 및 ARC결과와 비교분석하였다. 또한 순도가 낮은 AP에 대해서는 재결정을 통해 포함된 불순물을 제거한 후 분석한 결과, 열적 안정성이 높아졌음을 확인하였다. DSC 고압팬을 사용하여 AP 순도를 결정하는 정량적 분석방법을 확립하였다.

GMAW에서 아크 빛을 이용한 실시간 용접품질 모니터링에 관한 연구 (A Study on On-Line Quality Monitoring Using Arc Light in Gas Metal Arc Welding)

  • 조택동;양상민
    • Journal of Welding and Joining
    • /
    • 제18권4호
    • /
    • pp.82-86
    • /
    • 2000
  • Gas metal arc welding(GMAW) is regarded as one of the best candidate for welding automation in industrial joining application. It is important to monitor the weld quality for the high performance weld automation. In GMAW, weld quality is closely related to arc stability especially. In this paper, arc light signal is measured and spectrum analyzed to the detect the variation of the weld quality. The FFT of the signal showed that the amplitude variance of FFT power spectrum was very large in poor weld process such as the decrease of weld bead width and height. The results show that it is possible to detect the weld defect position in weld process.

  • PDF

MAG 용접의 스패터 발생 및 용적이행현상에 미치는 Si의 영향 (Effect of Si on Spatter Generation and Droplet Transfer Phenomena of MAG Wwlding)

  • 안영호;이종봉;엄동석
    • Journal of Welding and Joining
    • /
    • 제17권3호
    • /
    • pp.36-43
    • /
    • 1999
  • The effect of Si content in welding wires on spattering characteristics and droplet transfer phenomena was studied. In MAG welding using 80% Ar-20% $CO_2$ shielding gas, spattering characteristics and droplet transfer phenomena were varied with Si content of wire. With increasing Si content, the spattering ratio and the ratio of large size spatter $(d\geq1.0mm)$ were increased. The increase of Si content in molten metal made surface tension increase due to reduction of oxygen content, which resulted from deoxidizing action of silicon. The increase of surface tension resulted in unstable transfer phenomena and arc instability in both short circuit and spray region. With changing Si content of wire, spattering characteristics and droplet transfer phenomena was directly influenced by the variation of surface tension, compared with the effect of arc stability.

  • PDF