• 제목/요약/키워드: Arc Pressure

검색결과 379건 처리시간 0.034초

MIVB 용접용 개폐형 자속발생기에 의한 자원밀도분포의 수치해석 (Numerical Analysis of Magnetic Flux Density Distribution by an Openable Magnetic Flux Generator for MIAB Welding)

  • 구진모;김재웅
    • Journal of Welding and Joining
    • /
    • 제22권6호
    • /
    • pp.50-56
    • /
    • 2004
  • MlAB(magnetically impelled arc butt) welding is a sort of pressure welding method by melting two pipe sections with high speed rotating arc and upsetting two pipes in the axial direction. The electro-magnetic force, the driving force of the arc rotation, is generated by interaction of arc current and magnetic field induced from the magnetic flux generator in the welding system. In this study, an openable coil system for the generation of magnetic flux and a 3-dimensional numerical model for analyzing the electro-magnetic field were proposed. Through the fundamental numerical analyses, a magnetic concentrator was adopted for smoothing the magnetic flux density distribution in the circumferential direction. And then a series of numerical analysis were performed for investigating the effect of system parameters on the magnetic flux density distribution in the interested welding area.. Numerical quantitative analyses showed that magnetic flux density distribution generated from the proposed coil system is mainly dependent on the exciting current in the coil and the position of coil or concentrator from the pipe outer surface. And the gap between pipe ends and arc current are also considered as important factors on arc rotating behavior.

Modelling and Analysis of Electrodes Erosion Phenomena of $SF_6$ Arc in a Laval Nozzle

  • Lee, Byeong-Yoon;Liau, Vui Kien;Song, Ki-Dong;Park, Kyong-Yop
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.972-974
    • /
    • 2005
  • The present work deals with the theoretical study of the effects of copper vapours resulting from the erosion of the electrodes on the properties of a SF6 arc in a Laval nozzle. Computations have been done for a DC arc of 1000A with upstream gas pressure of 3.75MPa. The arc plasma is assumed to be in local thermodynamic equilibrium(LTE). The sheath and non-equilibrium region around the electrodes are not considered in this model. However, its effects on the energy flux into the electrodes are estimated from some experimental and theoretical data. The turbulence effects are calculated using the Prandtl mixing length model. A conservation equation for the copper vapour concentration is solved together with the governing equations for mass, momentum and energy of the gas mixture. Comparisons were made between the results with and without electrodes erosion. It has been found that the presence of copper vapours cools down the arc temperature due to the combined effects of increased radiation and increased electrical conductivity. The copper vapour distribution is very sensitive to the turbulent parameter. The erosion of upstream electrode(cathode) has larger effects on the arc compared to the downstream electrode(anode) as the copper vapour eroded from the anode cannot diffuse against the high-speed axial flow.

  • PDF

PASB 아크 플라즈마 챔버에서 발생하는 유동 및 물질전달에 관한 연구 (Study on the Flow and Mass Transfer in a PASB Arc Plasma Chamber)

  • 이종철;김윤제
    • 한국유체기계학회 논문집
    • /
    • 제11권4호
    • /
    • pp.7-13
    • /
    • 2008
  • The computational investigation is performed to find out the interaction of arc plasmas with surrounding materials and the thermal flow characteristics in a PASB (Puffer-Assisted Self-Blast) chamber, which is one of new breaking concepts in $SF_6$ switchgears. It is very important to define the flow and mass transfer happened during the full arcing history for further understanding complex physics inside the chamber. In this study, we have considered two diffusion processes by the hot arc plasma, one is PTFE nozzle ablation and the other is Cu electrode evaporation, simultaneously. It was found that the principle of the pressure-rise inside the chamber is confirmed by the computational results and the increase of the electrical conductivity of the residual gas near current zero is critical to the chamber design.

초고압 차단부 아크방전 수치해석 및 난류모델에 관한 연구 (STUDY ON NUMERICAL ANALYSIS AND TURBULENCE MODELS FOR ARC DISCHARGES IN HIGH-VOLTAGE INTERRUPTERS)

  • 김우영;이종철
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.201-207
    • /
    • 2010
  • In this study, we calculated arc discharges happened in high-voltage circuit breakers for understanding the complex physics and the probability of thermal breakdown. The four main parts of arc model for this virtual-reality are radiation, PTFE abaltion, Cu evaporation and turbulence. Among these important parts the turbulence model can be critical to the reliability of computation results during high-current period because the plasma flow is affected by high eat energy and mass momentum. Two kinds of turbulence model, zero-equation model and two-equation model, are applied for these calculations and are compared with the measured pressure data inside a chamber.

  • PDF

고휘도 Short-Arc 램프용 전자식 안정기 설계 및 제작 (The Design and Fabrication of an Electronic Ballast for High Intensity Short-Arc Lamps)

  • 김일권;박대원;이성근;길경석
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.304-309
    • /
    • 2005
  • This paper presents an electronic ballast using a step down converter, a low frequency inverter for high intensity short-arc discharge lamp. The proposed ballast is composed of a full-wave rectifier, a step down converter operated as a current source with power regulation and a low frequency inverter with external ignition circuit. The ignition circuit generates high voltage pulse of $3{\sim}5[kV]$ peak, 130[Hz] periodically. Moreover, it is able to reignite at regular intervals by protective circuit. As experimental results on the test, acoustic resonance phenomenon is eliminated by operating the low frequency square wave voltage and current. Lamp voltage, current and consumption power are measured 123.8[V], 8.1[A] and 1,002[W], respectively. It was confirmed that the designed ballast operate the lamp with a constant power.

  • PDF

열파퍼식 가스차단기에서 발생하는 아크 플라즈마에 의한 열유동 특성 (Thermal Flow Characteristics Driven by Arc Plasmas in a Thermal Puffer Type GCB)

  • 이종철;김윤제
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제54권11호
    • /
    • pp.527-532
    • /
    • 2005
  • During the last ten years the new interruption techniques, which use the arc energy itself to increase the pressure inside a chamber by the PTFE nozzle ablation, have displaced the puffer circuit breakers due to reduced driving forces and better maintainability. In this paper, we have investigated the thermal flow characteristics inside a thermal puffer type gas circuit breaker by solving the Wavier-Stokes equations coupled with Maxwell's equations for considering all instabilities effects such as turbulence and Lorentz forces by transient arc plasmas. These relative inexpensive computer simulations might help the engineer research and design the new interrupter in order to downscale and uprating the GIS integral.

PHOENICS Code를 이용한 자력팽창 소호부 내 아크유동해석 (The Flow Analysis of Arc in LG Hybrid Interrupter Using PHOENICS Code)

  • 이종철;이방욱;오일성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.44-46
    • /
    • 2001
  • This paper describes the use of the PHOENICS CFD package for the simulation of the high-current period of the arcing process in a hybrid rotating arc/auto expansion by interrupter. The operating principle of this device depends on rapid arc rotation due to the magnetic field created by the fault current through a coil which is mounted on contacts and also relies on the principle of thermal expansion created by arc energy in extinguishing chamber and finally causes pressure rise in expansion volume. This paper is divided into three main sections. The first gives a brief overview of the interrupter. The second section gives a full description of the methods used in the calculation. The final section presents some sample results for the hybrid interrupter.

  • PDF

아크용(用) 소모성(消耗性) 전극(電極) 제조(製造)를 위한 타이타늄 선삭(旋削) 스크랩의 재활용(再活用) (Recycling of Ti Turning Scraps for Production of Consumable Arc Electrode)

  • 오정민;임재원
    • 자원리싸이클링
    • /
    • 제21권5호
    • /
    • pp.58-64
    • /
    • 2012
  • 본 연구는 타이타늄 선삭 스크랩을 진공 아크 용해에 의해 건전한 버튼형 잉곳으로 제조하여 아크 발생용 소모성 전극으로의 재활용을 위해 타이타늄 내 불순물의 거동 및 특성을 평가하였다. 먼저 가스불순물인 산소는 진공 아크 용해에 의해 초기 표면의 산화층에 의해 제거되지만 이후 타이타늄에 고용된 산소는 제거되지 않는 것으로 확인되었다. 타이타늄 스크랩의 대표 금속불순물인 철의 경우 타이타늄과의 증기압 차이로 인해 진공 아크 용해에 의해 최종 20분간 용해시 약 43%의 제거율을 보이며, 최종 제조된 타이타늄 버튼형 잉곳은 ASTM 규격의 순 타이타늄 등급 3에 해당하는 순도를 보여 VAR(Vacuum Arc Remelting)용 소모성 전극의 제조에 가능한 것으로 확인하였다.

대구경-후판 압력용기용 저 합금강(Mn-Mo)의 용접특성 (A Welding Characteristics of Large Caliber-Thick Plate Pressure Vessel Low Alloy Steel (Mn-Mo))

  • 안종석;박진근;윤재연
    • Journal of Welding and Joining
    • /
    • 제30권6호
    • /
    • pp.10-14
    • /
    • 2012
  • Recently the low alloy steel plate made with manganese-molybdenum is used widely in steam drum and separator of the new coal-fired power plant boiler. This material is suitable for the vapor storage of high pressure and high temperature. The high temperature creep strength of Mn-Mo alloy is higher than the carbon plate(SA516) that used in the subcritical pressure boiler. It reduces the thickness of the pressure vessel and makes the lightweight possible. Recently in the power plant boiler operation and production process, the damage has happened frequently in the heat affected zone and base material according to the hydrogen crack and delayed crack. This paper describes the research result about the damage case experienced in the boiler steam drum production process and present the optimum manufacture method for the similar damage prevention of recurrence.

증기발생기 관판내부 균열 열화 특성 (Degradation Characteristics of Tubes in the Steam Generator Tubesheet)

  • 조남철;강용석;김형남;이국희
    • 한국압력기기공학회 논문집
    • /
    • 제10권1호
    • /
    • pp.7-14
    • /
    • 2014
  • There has been extensive experience associated with the operation of SGs wherein it was believed, based on NDE, that throughwall tube indications were present within the tubesheet. The installation of the SG tubes usually involves the development of a short interference fit, referred to as the tack expansion, at the bottom of the tubesheet. The tack expansion was usually effected by a hard rolling process and thereafter, in most instance, by the expansion of a urethane plug inserted into the tube end and compressed in the axial direction. The rolling process by its very nature is considered to be intensive with regard to metalworking at the inside surface of the tube and would be expected to lead to higher residual surface stresses. Alternate repair criteria(ARC) in the tack expansion area have been developed and applied to nuclear power plants in USA, however domestic nuclear power plants have not applied ARC for tubes in tubeheet area yet. In consideration of the degradation characteristics of tubes in the Steam Generator tubesheet, this paper suggests ARC application for tubes in the steam generator tubesheet of the domestic nuclear power plants in order to assure life time of the steam generator as well as nuclear power plants.