• Title/Summary/Keyword: Arc Grid

Search Result 111, Processing Time 0.028 seconds

Development of the 120kV/70A High Voltage Switching Circuit with MOSFETs Operated by Simple Gate Drive Unit (120kV/70A MOSFETs Switch의 구동회로 개발)

  • 송인호;최창호
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.1
    • /
    • pp.24-29
    • /
    • 2003
  • A 120kV/70A high voltage switch has been installed at Korea Atomic Energy Research Institute(KAERI) in Taejon to supply power with Korea Superconducting Tokamak Advanced Research(KSTAR) Neutral Beam Injection(NBI) system. NBI system requires fast cutoff of the flower supply voltage for protection of the grid when arc detected and fast turn-on the voltage for sustaining the beam current. Therefore the high voltage switch and arc current detection circuit are important part of the NBI power supply. There are much need for high voltage solid state switches in NBI system and a broad area of applications. This switch consisted of 100 series connected MOSFETs and adopted the proposed simple and reliable gate drive circuit without bias supply. Various results taken during the commissioning phase with a 100kW resistive load and NBI source arc shown. This paper presents the detailed design of 120kV/70A high voltage MOSFETs switch and simple gate drive circuit. Problems with the high voltage switch and gate driver during thefabrication and test and solutions are also presented.

Dual Utility AC Line Voltage Operated Voltage Source and Soft Switching PWM DC-DC Converter with High Frequency Transformer Link for Arc Welding Equipment

  • Morimoto Keiki;Ahmed NabilA.;Lee Hyun-Woo;Nakaoka Mutsuo
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.5B no.4
    • /
    • pp.366-373
    • /
    • 2005
  • This paper presents two new circuit topologies of the dc busline side active resonant snubber assisted voltage source high frequency link soft switching PWM full-bridge dc-dc power converters acceptable for either utility ac 200V-rms or ac 400V-rms input grid. These high frequency switching dc-dc converters proposed in this paper are composed of a typical voltage source-fed full-bridge PWM inverter, high frequency transformer with center tap, high frequency diode rectifier with inductor input filter and dc busline side series switches with the aid of a dc busline parallel capacitive lossless snubber. All the active switches in the full-bridge arms as well as dc busline snubber can achieve ZCS turn-on and ZVS turn-off transition commutation with the aid of a transformer leakage inductive component and consequently the total switching power losses can be effectively reduced. So that, a high switching frequency operation of IGBTs in the voltage source full bridge inverter can be actually designed more than about 20 kHz. It is confirmed that the more the switching frequency of full-bridge soft switching inverter increases, the more soft switching PWM dc-dc converter with a high frequency transformer link has remarkable advantages for its power conversion efficiency and power density implementations as compared with the conventional hard switching PWM inverter type dc-dc power converter. The effectiveness of these new dc-dc power converter topologies can be proved to be more suitable for low voltage and large current dc-dc power supply as arc welding equipment from a practical point of view.

CUMAP : A Chill Unit Calculator for Spatial Estimation of Dormancy Release Date in Complex Terrain (Chill Unit 축적과 휴면해제시기 공간변이 추정 프로그램 : CUMAP)

  • Kim Kwang S.;Chung U ran;Yun Jin I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.6 no.3
    • /
    • pp.177-182
    • /
    • 2004
  • A chill unit has been used to estimate chilling requirement for dormancy release and risk of freezing damage. A system that calculates chill units was developed to obtain site-specific estimates of dormancy release date for grapes and evaluated in Baekgu myun near Kimje City, Chunbuk, Korea from September 2002 to March 2003. The system utilized daily minimum and maximum temperature maps generated from spatial interpolation with temperature correction for topography. Hourly temperature was temporally interpolated from the daily data using a sine-exponential equation (Patron and Logan, 1981). Hourly chill units were determined from sigmoid, reverse sigmoid, and negatively increasing sigmoid functions based on temperature ranges and summed for 24 h. Cumulative daily chill units obtained from measurements did not increase until 20 October 2002, which was used as a start date for accumulation to estimate the dormancy release date. As a result, a map of dormancy release date in the study area was generated, assuming 800 chill units as a threshold for the chilling requirement. The chill unit accumulation system, implemented using Microsoft Visual Basic and C++ (Microsoft, Redmond, WA, USA), runs in the Windows environment with ArcView (ESRl Inc., Redlands, CA, USA).

Continental Land Cover Mapping/Monitoring and Ground Truth Database

  • Tateishi, Ryutaro;Wen, Chen-Gang;Park, Jong-Geol
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.13-18
    • /
    • 1999
  • Land cover map of 30 arc-second grid by NOAA AVHRR data for the whole Asia was produced by the authors as the project of the Asian Association on Remote Sensing(AARS). Land cover change monitoring of continental scale by satellite data needs preprocessing to remove undesirable factors due to noises, atmosphere, or the effect by solar zenith angle. The paper describes the method to remove these factors. The most important thing for better mapping/monitoring in the future is the accumulation of ground truth data by many land cover related researchers. The project of the development of Global Land Cover Ground Truth Database(GLCGT-DB) is proposed.

  • PDF

Interpretation of shallow geological structure by applying GIS to geophysical data (물리탐사자료의 GIS 복합처리에 의한 천부지질구조 해석)

  • 송성호;정형재
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 1998.11a
    • /
    • pp.123-126
    • /
    • 1998
  • We have conducted surface electrical resistivity surveys along with the electrical logging at Bookil-Myun, Chungwon-Goon, Choongchungbuk-Do to determine the depths of basement and water table, and for the purpose of preparing the basic input data for hydrogeologic model combined with GIS. A twenty lines of dipole-dipole array survey and a twenty-five stations of resistivity sounding were performed and ten holes were employed for electrical logging to cross check the surface data. A combined interpretation gave the quantitative information of the shallow geologic structure over the area and we constructed layers using the grid analysis of Arc/info. The constructed layers were turned out to be similar to the geologic structure confirmed from the drilling data and we concluded that the methodology adopted in this study would be applicable to hydrogeologic model setup as a tool of providing the basic input data.

  • PDF

A study of Land Suitability Analysis using Algorithms of Artificial Neural Network (인공신경망의 알고리즘에 의한 토지적합성분석에 관한 연구)

  • Yang, Ok-Jin;Jeong, Yeong-Dong
    • 한국지형공간정보학회:학술대회논문집
    • /
    • 2001.04a
    • /
    • pp.1-15
    • /
    • 2001
  • 본 연구는 도시토지이용의 적합성분석을 실시하는 데 있어 GSIS와 인공신경망의 유기적인 결합을 시도해 보았다. 인공신경망은 학습이라는 과정을 통해 신경망 노드(node)간의 연결강도를 합리적으로 결정할 수 있는 이점이 있다. 이러한 점에서 공간분석에서 요구되는 인자간의 경중률과 신경망의 연결강도는 대체가 가능하리라 판단된다. 본 연구를 수행하기 위해 두 종류의 신경망을 구성하였다. 1차 신경망은 토지이용별 적합성 분석에 적용했으며, 2차 신경망은 최적의 토지이용패턴을 분석하기 위해 구성하였다. 이들 신경망은 C++로 작성된 프로그램에 의해 구현된 최급강하법에 의한 역전파 알고리즘에 의해 학습을 실시하였으며, 활성화 함수는 시그모이드 함수를 사용하였다. 분석결과는 현행 용도지역제에서 주거, 상업, 공업, 녹지에 대한 토지이용 적합도면과 4가지 유형의 토지이용에 대한 대상지역의 최적토지이용패턴을 제시한 도면으로서 Arc/Info의 Grid 형식으로 작성하였다. 또한 토지이용별 적합도면상에 나타난 적합지역과 최적토지이용패턴은 위치적인 면과 공간 구성에 있어 실제의 도시토지이용계획의 이론적인 개념에 매우 합치되는 분포형태를 보였다.

  • PDF

The Development for Change Detection Technique in the Remotely Sensed Images by GIS (GIS를 이용한 원격탐사영상의 변화탐지기법 개발)

  • 양인태;한성만;박재국;천기선
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.04a
    • /
    • pp.397-408
    • /
    • 2003
  • The information about land use presents future development and vision being the basis of nation development; therefore, it is necessary to more active research that can detect wide land use and changes for the information and efficient management about land use. In this study, we wished to analyze effectively land use changes to Ansan city that is fast changing land use by the latest national land development and urbanization. this study executed land-cover classification using 4 year's Landsat TM images including Ansan city, and efficiently could manage the result of land-cover changes through Arc/Info GRID analysis. Especially, by using change detection system that is developed in this research, we could variously detect land-cover changes, and query and search easily past land-cover changes of pixels that correspond to specific region.

  • PDF

The Assessment of Water Pollution Accident on Dam Watershed using GIS (GIS에 의한 댐 유역 수질오염사고 평가)

  • Myeong, Gwang Hyeun;Jeong, Jong Chul
    • Journal of Environmental Impact Assessment
    • /
    • v.20 no.4
    • /
    • pp.489-496
    • /
    • 2011
  • The water pollution such as oil spill from stream and river because of car accidents have been frequent cases in the watershed of Dam. However we don't have any simulation methods about flow modeling on the watershed and stream tree. In this study aims to analyze water pollution accidents area on impact range for ANDONG-Dam. The focused watershed and the risk range of path analysis model was designed by GIS database. The frequency of transportation accidents which may occur from road accidents in the level of quantitative and qualitative analysis to map flow analysis using ArcHydro Model and Open Geospatial Consortium(OGC) API. and the path way from the accident point to the reservoir stayed on the path was simulated. The area of risk accessment index was displayed with cell and grid of dam area.

Validation of Some Protection Guidelines for Neighboring Pipelines against Fault Currents from Power Transmission Tower

  • Lee, Seong-Min;Song, Hong-Seok;Kim, Young Geun
    • Corrosion Science and Technology
    • /
    • v.6 no.2
    • /
    • pp.77-81
    • /
    • 2007
  • Fault current can be discharged from power transmission tower due to lightning or inadvertent contact of crane, etc. Pipelines in proximity to either the source of the ground fault or the substation grounding grid may provide convenient conductive path for the fault current to travel. Inappropriate measures to the neighboring pipelines against the fault current may cause severe damages to the pipes such as coating breakdown, arc burn, puncture, loss in wall thickness, or brittle heat-affected zone. Like inductive and conductive AC coupling, steadily induced fault current right after the coating breakdown can lead to corrosion of the pipeline. In this work, some protection guidelines against fault currents used in the field have been validated through the simulation and analytical method.

Neutral Beam Evolution in the KSTAR NBI Test Stand

  • In, S.R.;Shim, H.J.
    • Journal of Korean Vacuum Science & Technology
    • /
    • v.7 no.1
    • /
    • pp.1-7
    • /
    • 2003
  • The pressure distributions in the test stand built for developing KSTAR NBI ion sources were obtained using a network system composed of conductance elements modeling the ion source, the neutralizer, and other beam line components. The allowable regime was defined on the coordinates of the gas supply rate to the ion source and the neutralizer, considering the proper conditions of the three critical parameters, the ion source pressure for good arc discharge, the pressure integral in the neutralizer for sufficient neutralization, and the chamber pressure for minimum neutral beam loss. The neutral beam evolution along the path from the ion source extraction grid to the calorimeter through the neutralizer, the bending magnet and the vacuum chamber was estimated for typical pressure distributions.

  • PDF