• Title/Summary/Keyword: Arc Grid

Search Result 110, Processing Time 0.024 seconds

A Multi-megawatt Long Pulse Ion Source of Neutral Beam Injector for the KSTAR

  • Chang, Doo-Hee;Seo, Chang-Seog;Jeong, Seung-Ho;Oh, Byung-Hoon;Lee, Kwang-Won;Kim, Jin-Choon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2004.10a
    • /
    • pp.719-720
    • /
    • 2004
  • A multi-megawatt long pulse ion source (LPIS) of neutral beam injector was developed for the KSTAR. Beam extraction experiments of the LPIS were carried out at the neutral beam test stand (NBTS). Design requirements for the ion source were 120 kV/65 A deuterium beam and a 300 s pulse length. A maximum ion density of $9.1310^{11}$ $cm^{-3}$ was measured by using electric probes, and an optimum arc efficiency of 0.46 A/kW was estimated with ion saturation current of the probes, arc power, and total beam area. An arcing problem, caused by the structural defect of decelerating grid supporter, in the third gap was solved by the blocking of backstream ion particles, originated from the plasma in the neutralizer duct, through the unnecessary spaces on the side of grid supporter. A maximum drain power of 1.5 MW (i.e. 70 kV/21 A) with hydrogen was measured for a pulse duration of 0.5 s. Optimum beam perveance was ranged from 0.75 to 0.85. An improved design of accelerator for the effective control of beam particle trajectory should provide higher beam perveance.

  • PDF

Assessment and Management Method of Flicker Emission Level Based on IEC 61000-3-7 for Domestic Extra-high Voltage Customers (국내 특고압 고객에 대한 IEC 61000-3-7 기반의 플리커 방출한계 평가 및 관리 방안 연구)

  • Han, Su-Kyoung;Shin, Hoon-Chul;Park, Sang-Ho;Kim, Kern-Joong;Cho, Soo-Hwan
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.67 no.1
    • /
    • pp.1-7
    • /
    • 2018
  • IEC 61000-3-7 provides guidance for limiting flicker and enabling the connection of fluctuating load installations, that is, producing flicker in MV, HV and EHV power systems. In Korea, the flicker have been restricted by Japanese standard of ${\Delta}V_{10}$ method. ${\Delta}V_{10}$ was developed only for arc furnaces in 1960's. And now it is revealed that it is not suitable for application to other fluctuating load installations through many researches. $P_{st}$ which is a flicker index used in IEC 61000-3-7, indicates visual inconvenience due to voltage fluctuation across large range of frequency and can be applied to fluctuating load installations as well as arc furnaces. In this paper, we introduce how to calculate and assess flicker emission level for the individual fluctuating load installations connected in EHV system and how to manage the emission levels in the power system according to IEC 61000-3-7.

Methods for Increasing the Interrupting Performance of Are Chamber in 460V / 50KA / 100AF Molded Case Circuit Breaker (460V / 50KA / 100AF 급 배선용 차단기의 소호부 차단 성능 향상 방법)

  • Cho, Sung-Hoon;Jung, Eui-Hwan;Lee, Han-Ju;Lim, Kee-Joe;Kim, Kil-Sou
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.105-105
    • /
    • 2010
  • Voltage circuit breakers are widely used in power distribution systems to interrupt fault current rapidly and to assure the reliability of the power supply. Power distribution system requires the transformer with higher capacity than ever, but this ever, but this may be the cause. of the increasing of short circuit current in contrast to conventional one when short-circuit accident is occurred. Therefore molded case circuit breaker improved in aspects of interrupting capacity of short circuit current in this system is needed. By using the proposed methods in this paper, such as new arc quenching structure of grid would contribute to minimizing the MCCB, realization of high interrupting performance and reducing the design time and development cost.

  • PDF

Geographic Information System Application to Wellhead Protection Area Delineation (우물수원 보호구역의 범위 결정에 대한 지형정보시스템의 응용)

  • Kim, Chul
    • Journal of Korea Water Resources Association
    • /
    • v.31 no.1
    • /
    • pp.27-34
    • /
    • 1998
  • Groundwater simulation model suing GIS and Arc/Info Gridfunctions were used to delineate wellhead protection areas. Groundwater simulation model was developed within Arcview GIS. The model. which integrates the data input and manipulation. Process simulation. and display of the results . was developed by considering time variations of the parameters. The model was applied to the EPA data. The hydraulic distributions from the EPA data and those calculated from groundwater simulation model agree well and zone of influence from EPA data and that calculated suing GRID functions seem to be consistent. The developed model may be an efficient tool to delineate WHPA because it integrates all the processes inside the GIS.

  • PDF

Fluid Dynamics Analysis and Experimental Trial to Improve the Switching Performance of Eco-friendly Gas Insulated Switch (친환경 가스개폐기 개폐성능 향상을 위한 유동해석 및 실험)

  • Yu, Lyun;Ahn, Kil-Young;Kim, Young-Geun;Cho, Hae-Yong
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.21 no.9
    • /
    • pp.42-49
    • /
    • 2022
  • An underground electric switch is a high-voltage switch used in distribution network systems for a reliable power supply. Many studies are being conducted to expand the switch to use an eco-friendly gas using dry air instead of SF6 gas to reduce greenhouse gas emissions. In this study, a flow analysis model was established to improve the performance of an eco-friendly gas switch. The results were compared and reviewed through experiments. For the optimal arc grid design applied to the switch, the flow characteristics based on the flow path configuration and the changes in arcing time for each configuration were compared. Flow analysis can predict the switch flow distribution, and a comparative review of the flow path configurations of various methods is possible.

Applicability of VariousInterpolation Approaches for High Resolution Spatial Mapping of Climate Data in Korea (남한 지역 고해상도 기후지도 작성을 위한 공간화 기법 연구)

  • Jo, Ayeong;Ryu, Jieun;Chung, Hyein;Choi, Yuyoung;Jeon, Seongwoo
    • Journal of Environmental Impact Assessment
    • /
    • v.27 no.5
    • /
    • pp.447-474
    • /
    • 2018
  • The purpose of this study is to build a new dataset of spatially interpolated climate data of South Korea by performing various geo-statistical interpolation techniques for comparison with the LDAPS grid data of KMA. Among 595 observation data in 2017, 80 % of the total points and remaining 117 points were used for spatial mapping and quantification,respectively. IDW, cokriging, and kriging were performed via the ArcGIS10.3.1 software and Python3.6.4, and each result was then divided into three clusters and four watersheds for statistical verification. As a result, cokriging produced the most suitable grid climate data for instantaneous temperature. For 1-hr accumulated precipitation, IDW was most suitable for expressing local rainfall effects.

Long-term Runoff Analysis Using the TOPMODEL (TOPMODEL을 이용한 장기유출 해석)

  • Jo, Hong-Je;Kim, Jeong-Sik;Lee, Geun-Bae
    • Journal of Korea Water Resources Association
    • /
    • v.33 no.4
    • /
    • pp.393-405
    • /
    • 2000
  • Monthly runoff was estimated using TOPMODEL which simulates ground water movement as well as surface runoff in the area of catchment. SAYUN dam which is being operated by Korea Water Resources Corporation was selected for the study, and the topographic factors of the watershed were analyzed using 1/5,000 digital map and GIS software(Arc/Info). The comparison shows good agreement between observed monthly runoff and the computation results simulated by using TOPMODEL. The catchment area of SAYUN dam was modeled by using various grid sizes in order to check the sensitivity of grid size, and the grid size of 180m was found most proper among 6 different sizes. TOPMODEL was also found superior to the existing monthly runoff models such as Kajiyama, KRIHS and Tank. Because the model requires limited number of parameters and considers topographic aspects, it is reckoned to be very useful for practical use.

  • PDF

Analysis Of Dielectric Recovery Characteristics for $SF_6$ Gas-Blast AFC ($SF_6$아크의 절연회복특성 해석)

  • Song, Gi-Dong;Lee, Byeong-Yun;Park, Gyeong-Yeop;Park, Jeong-Hu
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.6
    • /
    • pp.273-284
    • /
    • 2002
  • In this paper, computer simulations of the physical Phenomena occurring in the arc region before and after current zero were carried out to evaluate the dielectric recovery characteristics of two types of double-flow nozzles. A commercial CFD Program "PHOENICS" is used for the simulation and the user-coded subroutines to consider the arcing phenomena were added to this program by the authors. The computed results were verified by the comparison with the test results presented by the research group of BBC. In order to investigate the state of the arc region after current zero, the simulation was carried out with four steps. They are cold gas flow analysis, steady state arc simulation, transient arc simulation before current zero, transient hot gas flow simulation after current zero. The semi-experimental arc radiation model is adapted to consider the radiation energy transport and Prandtl′s mixing length model is employed as the turbulence model. The electric field and the magnetic field were calculated with the same grid structure used for the simulation of the flow field. The streamer criterion was introduced to evaluate the dielectric recovery characteristics after current zero. Compared with the results obtained by assuming the current zero state in the former studies, it has been found that the results obtained by considering the state before current zerowere more accurate.

Development and Testing of a Prototype Long Pulse Ion Source for the KSTAR Neutral Beam System

  • Chang Doo-Hee;Oh Byung-Hoon;Seo Chang-Seog
    • Nuclear Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.357-363
    • /
    • 2004
  • A prototype long pulse ion source was developed, and the beam extraction experiments of the ion source were carried out at the Neutral Beam Test Stand (NBTS) of the Korea Superconducting Tokamak Advanced Research (KSTAR). The ion source consists of a magnetic bucket plasma generator, with multi-pole cusp fields, and a set of tetrode accelerators with circular apertures. Design requirements for the ion source were a 120kV/65A deuterium beam and a 300 s pulse length. Arc discharges of the plasma generator were controlled by using the emission-limited mode, in turn controlled by the applied heating voltage of the cathode filaments. Stable and efficient arc plasmas with a maximum arc power of 100 kW were produced using the constant power mode operation of an arc power supply. A maximum ion density of $8.3{\times}10^{11}\;cm^{-3}$ was obtained by using electrostatic probes, and an optimum arc efficiency of 0.46 A/kW was estimated. The accelerating and decelerating voltages were applied repeatedly, using the re-triggering mode operation of the high voltage switches during a beam pulse, when beam disruptions occurred. The decelerating voltage was always applied prior to the accelerating voltage, to suppress effectively the back-streaming electrons produced at the time of an initial beam formation, by the pre-programmed fast-switch control system. A maximum beam power of 0.9 MW (i.e. $70\;kV{\times}12.5\;A$) with hydrogen was measured for a pulse duration of 0.8 s. Optimum beam perveance, deduced from the ratio of the gradient grid current to the total beam current, was $0.7\;{\mu}perv$. Stable beams for a long pulse duration of $5{\sim}10\;s$ were tested at low accelerating voltages.

Development of DC Arc Generator to protect against Malfunctions and Fires caused by Arcing (아크 발생에 따른 고장 및 화재를 보호하기 위한 직류 아크 Generator 개발)

  • Yoon, Yongho
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.21 no.6
    • /
    • pp.123-128
    • /
    • 2021
  • As the spread of DC power distribution systems increases, the occurrence of failures and fire accidents are also increasing. In particular, the ESS fire accident, which is a component of the smart grid, and the fire accident of the solar power system, which is a direct current system, are caused by problems in the electrical connection between system components as the supply of new and renewable energy rapidly increases and old facilities increase. An arc that can cause a direct fire by releasing the induced light and heat has been pointed out as one of the causes of fire. Therefore, the problem of such an arc defect is that it is impossible to block an arc accident in advance with the existing overcurrent circuit breaker and earth leakage circuit breaker. In this paper, we intend to develop a test equipment that satisfies international standardization and to develop a DC arc generator to protect against failure and fire caused by arcing.