• Title/Summary/Keyword: Aqueous electrolysis experiment

Search Result 9, Processing Time 0.023 seconds

Analysis and Improvement of Experiments for Electrolysis of an Aqueous CuCl2 Solution in High School Science Textbooks (고등학교 과학 교과서에 제시된 염화구리(II) 수용액의 전기분해 실험의 분석 및 개선)

  • Park, Guk-Tae;Jo, Yeong-Ja;Lee, Ji-Yeong;Park, Gwang-Seo
    • Journal of the Korean Chemical Society
    • /
    • v.50 no.4
    • /
    • pp.328-337
    • /
    • 2006
  • purpose of this study was to find out problems in experiments for electrolysis of an aqueous CuCl2 solution in high school science textbooks and to suggest an improved experiment considering students' capability of experimenting and laboratory safety in high schools. For this study, the experiments for electrolysis of an aqueous CuCl2 solution presented in 11 high school science textbooks were classified by their experimental methods. After high school chemistry teachers performed the experiments as presented in the high school science textbooks, an analysis was performed on problems of the experiments, and an improved experiment was devised. According to the results of this study, in the experiments for electrolysis of an aqueous CuCl2 solution using a U type tube and a U type tube with branch, reaction velocity of the electrolysis was slow, therefore, a side reaction was generated. In the experiment using a beaker, reaction of each electrode could not be observed separately. And in the experiment using an electrolysis instrument, it was difficult to identify property of the reaction product. In the improved experiment using a reaction vessel of ㅂshape, reaction velocity of the electrolysis was fast, reaction of each electrode could be observed separately, and the side reaction decreased. From these results, it was suggested that the improved experiment would help high school students understand scientific conception regarding electrolysis.

A Study on Active Ion Transport Technology to Improve Water Electrolysis System Performance (수전해 시스템 성능 향상을 위한 능동 이온수송 기술 연구)

  • HYEON-JUNG KIM;HAO GUO;SANG-YOUNG KIM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.34 no.2
    • /
    • pp.132-140
    • /
    • 2023
  • In this study, rotary magnet holder (RMH) was manufactured to analyze the ion transport effect according to the rotating magnetic field for the hydrogen production efficiency by alkaline water electrolyte. In the experiment, the voltage signal according to the magnet arrangement inside the RMH, the rotation speed, and the rotation time was measured using the voltage measurement module. As a result of the voltage signal measurement experiment, the average potential difference increased as the rotation speed of the RMH increased. Through the results of the voltage signal measurement experiment, the most efficient magnet arrangement (case 2) was applied to the RMH to conduct a water electrolysis experiment. A 20% NaOH aqueous solution was filled in the electrolytic cell, and a direct current 2 V constant voltage was applied to measure the current value according to the RMH rotation to compare the hydrogen generation amount. When rotating at 100 RPM, the hydrogen production efficiency increased by 8.06% compared to when not rotating. Considering the area exceeding +25 mA, which was not measured at the beginning of the experiment, an increase in hydrogen production of about 10% or more can be expected.

Electrochemical Degradation of Benzoquinone in a Flow through Cell with Carbon Fibers

  • Yoon, Jang-Hee;Yang, Jee-Eun;Shim, Yoon-Bo;Won, Mi-Sook
    • Bulletin of the Korean Chemical Society
    • /
    • v.28 no.3
    • /
    • pp.403-407
    • /
    • 2007
  • The anodic degradation of benzoquinone(BQ), a model compound for wastewater treatment was carried out using a home-made flow-through electrochemical cell with carbon fibers. To optimize the controlled current electrolysis condition of an aqueous BQ solution, the experimental variables affecting the degradation of BQ, such as the applying current, pH, reaction time, and flow rate of the BQ solution were examined. The degradation products of the oxidation reaction were identified by High Performance Liquid Chromatography and Inductively Coupled Plasma Atomic Emission Spectrometer. Low molecular weight aliphatic acids, and CO2 were the major products in this experiment. The removal efficiency of BQ from the solution increased with the applying current and time. 99.23% of 1.0 × 10-2 M BQ was degraded to aliphatic acids and CO2 when the applying current is 175 mA in a 12 hr electrolysis.

Hydration Properties of Cement Matrix using Electrolysis Alkaline Aqueous and Ground Granulated Blast Furnace Slag (전기분해 알칼리 수 및 고로슬래그 미분말 혼입 시멘트 경화체의 수화 특성)

  • Jung, Yoong-Hoon;Kim, Ho-Jin;Park, Sun-Gyu
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.9 no.2
    • /
    • pp.185-190
    • /
    • 2021
  • Cement has been used as a main material in the modern construction industry. However, it has been pointed out as a main cause of global warming due to carbon dioxide generated during manufactured. Recently, research that replacing cement substitute to industrial by-products such as Blast Furnace Slag which is by-producted in steelworks. When Blast Furnace Slag is used as a cement substitute, it shows a problem of lower initial strength, which is caused by glassy membrane on the particle surface. In this study, we used Electrolysis Alkaline Aqueous to improve the usability and problem of lower initial strength. As a result of the experiment, cement matrix using Blast Furnace Slag and Alkaline Aqueous showed initial strength and hydrate product were developed than that using general mixing water. Also, as a result of porosity analysis, It was confirmed that cement matrix using Alkaline Aqueous and Blast Furnace Slag has a tighter structure in internal porosity and porosity distribution than using general mixing water.

Analysis of Contents related to Models in the Chemistry Textbooks of the 2009 & 2015 Revised Curricula: Focusing on the Electrolysis of Aqueous Solutions (2009 및 2015 개정 교육과정의 화학 교과서에서 모델 관련 내용 분석: 수용액 전기 분해를 중심으로)

  • Kim, Kihyang;Chang, Hasok;Paik, Seoung-Hey
    • Journal of the Korean Chemical Society
    • /
    • v.63 no.4
    • /
    • pp.289-306
    • /
    • 2019
  • The purpose of this study is to compare the contents of chemistry textbooks developed according to the 2015 revised curriculum with the contents of the 2009 revised curriculum to research the change in "the development and use of models". To do this, we analyzed 8 kinds of Chemistry I textbooks and 6 kinds of Chemistry II textbooks from the 2015 revised curriculum and compared them with 4 kinds of Chemistry I textbooks and 4 kinds of Chemistry II textbooks from the 2009 revised curriculum. The scope of the analysis was the explanations of the textbooks related to aqueous electrolysis experiments. In order to compare the contents regarding electrolytes when the same experiments are interpreted with different models, we analyzed contents of 4 kinds of middle school science textbooks from the 2015 revised curriculum and 9 kinds of middle school science textbooks from the 2009 revised curriculum. As a result of the analysis, the same experiment was explained by different models according to the grade level and unit, and all explanations were limited to a single model. Also, the tendency to limit the kinds of electrolytes for controlled experimental results is more pronounced in the 2015 revised curriculum than in the 2009 revised curriculum. From this results, we suggest that efforts are needed to reflect the "development and use of models" in chemistry textbooks developed according to the 2015 revised curriculum.

A Study on Effect of the Shape of Electrodes in Alkaline Water Electrolysis (알카리 수전해에서 전극 형상의 영향에 관한 연구)

  • CHOI, SOOKWANG;KIM, JONGSOO;HAN, JIN MOOK;YUN, SEONG-HO;KIM, SEWOONG;JUNG, YOUNGUAN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.2
    • /
    • pp.121-128
    • /
    • 2017
  • For an investigation on the effect of the shape of electrodes in alkaline water electrolysis, two kinds of stack with circular and square electrode array are used to visualize both for behaviors of hydrogen bubble around the electrodes and for measurements of hydrogen production from these two stacks. The electrolytes for the hydrogen production experiment were applied for 20 wt%, 25 wt%, 30 wt% and 35 wt% of KOH alkaline aqueous solutions. As a result, the adhesion length of bubbles attached around the square electrode in the visualization experiment was found to be 1.7 times longer compared with the attached around the circular electrode. In the hydrogen production experiments, the volume of hydrogen production of the stack by using circular electrode array was approximately 3% more than that of the stack with square electrode array. These observations may be caused by the effect of the bubbles attached to the around the electrodes obstructing mass transfer such as hydrogen exhaust and electrolyte supply.

Basic study and patent analysis of electrochemical denitrification from industrial wastewater (산업폐수(産業廢水)로부터 전해처리(電解處理)에 의한 탈질(脫窒) 연구(硏究) 및 특허(特許) 분석(分析))

  • Lee, Churl-Kyoung
    • Resources Recycling
    • /
    • v.16 no.6
    • /
    • pp.52-60
    • /
    • 2007
  • Denitrification from aqueous solution was investigated through patent analysis and electrochemical denitrification experiment. Among several candidates, biological treatment and oxidation/reduction method are mainly discussed. Recently, patent pending concerning to electrochemical treatment is increasing. Based on basic electrochemical study, total nitrogen was removed up 47% by 1-hour galvanostatic electrolysis with Fe cathode and Pt anode. More applicable technique to industry could be mentioned combination of two or more technologies suitable to waste water characteristics. In the case of small and concentrate effluent, combination of chemical and electrochemical treatment would be recommendable because nitrate could be easily converted to nitrite by chemical treatment, and in that case denitrification by electrolysis becomes more efficient and metal ions from chemical treatment can be recovered during electrolysis.

Carbonation Resistance Property of Mortar using Electrolysis Aqueous (전기분해수를 배합수로 활용한 모르타르의 탄산화 저항 특성)

  • Jeong, Su-Mi;Park, Sun-Gyu
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.3
    • /
    • pp.204-210
    • /
    • 2022
  • Cement is pointed out as the main cause of carbon dioxide emission in the construction industry. Many researchs are underway to use blast furnace slag, an industrial by-product, as a substitute for cement to reduce carbon dioxide emitted during the manufacturing the cement. When blast furnace slag is used as a substitute for cement, it has advantages such as long-term strength and chemical resistance improvement. However, blast furnace slag has a problem that makes initial strength low. This is due to the impermeable film on the surface created during the production of blast furnace slag. The created film is known to be destroyed in an alkaline environment, and based on this, previous studies have suggested a solution using various alkali activators. But, alkali activator is dangerous product since it is a strong alkaline material. And it has the disadvantage in price competitiveness. In this study, an experiment was conducted to improve the initial hydration reactivity of the blast furnace slag to secure the initial strength of the mortar substituted with the blast furnace slag and to check whether the carbonation resistance was increased. As a result of the experiment, it was confirmed that the mortar using alkaline water showed higher strength than the mortar using tap water, and there were more hydration products generated inside. In addition, it was confirmed that the mortar using alkaline water as a compounding water had high carbonation resistance.

Characteristics of Copper-catalyzed Cyanide Decomposition by Electrolysis (전해법에 의한 구리함유 시안의 분해특성)

  • Lee Jin-Yeung;Yoon Ho-Sung;Kim Sung-Don;Kim Chul-Joo;Kim Joon-Soo;Han Choon;Oh Jong-Kee
    • Resources Recycling
    • /
    • v.13 no.1
    • /
    • pp.28-38
    • /
    • 2004
  • The characteristics of cyanide decomposition in aqueous phase by electric oxidization have been explored in an effort to develop a process to recycle waste water. Considering current efficiency and voltage, the free cyanide decomposition experiment by electric oxidization indicated that 5 V of voltage and copper catalytic Cu/CN mole ratio 0.05 was the most appropriate condition, where current efficiency was 26%, and decomposition speed was 5.6 mM/min. High voltage and excess copper addition increased decomposition speed a little bit but not current efficiency. The experiment of free cyanide density change proves that high density cyanide is preferred because speed and current efficiency increase with density. Also, the overall decomposition reaction could be represented by the first order with respcect to cyanide with the rate constant of $1.6∼7.3${\times}$10^{-3}$ $min^{-1}$ The mass transfer coefficient of electric oxidization of cyanide came out as $2.42${\times}$10^{-5}$ $min^{-1}$ Furthermore, the Damkohler number was calculated as 5.7 in case of 7 V and it was found that the mass transfer stage was the rate determining step.