• Title/Summary/Keyword: Applied load

Search Result 6,436, Processing Time 0.031 seconds

Comparison of Characteristics between $L_1-B_4$ mode and $L_1-B_8$ mode Ultrasonic Motors ($L_1-B_4$모드와 $L_1-B_8$모드 초음파 선형 전동기의 특성 비교)

  • U, Sang-Ho;Kim, Dong-Yeon;Kim, Jin-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1518-1520
    • /
    • 2002
  • Purpose of this research compares best transfer speed about applied frequency and voltage using characteristic of $L_1-B_4$ mode and $L_1-B_8$ mode linear ultrasonic motor that use piezoelectric effect. By method of study, analyzed best transfer speed measuring and comparison load status that use actuality telephone card in $L_1-B_4$ mode linear ultrasonic motor and no-load status of $L_1-B_8$ mode linear ultrasonic motor. Experiment result is applied frequency(58.4Hz) in $L_1-B_4$ mode linear ultrasonic motor (load state) and the best transfer speed by 19.8[cm/s] at applied voltage(56V) point. Also, $L_1-B_8$ mode linear ultrasonic motor (no-load state) is best transfer speed by applied frequency(27.9kHz) and 32.96[cm/s] at applied voltage (50V) point.

  • PDF

A THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF SINGLE IMPLANT PROSTHESES ACCORDING TO THE HEX-LOCK TYPE (단일 임플랜트 보철물의 Hex-lock 형태에 따른 3차원 유한요소법적 응력분석)

  • Hwang, Young-Pil;Kay, Kee-Sung;Cho, Kyu-Zong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.34 no.2
    • /
    • pp.385-402
    • /
    • 1996
  • The purpose of this study was to analyze how the stability of the implant prostheses and the loosening of the fastening screw was affected when the various types of Hex structure provided for the effect of anti-rotation of the single prostheses were given. Three dimensional finite element model was designed with which the implants with the external hex type of 0.75mm, 1.5mm and the implant with the internal hex type of 0.75mm, 1.5mm and the implant with the external hex type of $15^{\circ}$ tapered shape of 0.75mm were supposed to completely osseointegrate to the mandible. After fininshing the finite element model, the preload of 10N at the fastening screw was applied and then the vertical and $30^{\circ}$ lateral load of 200N was applied respectively at the cusp tips of the prostheses. The following results were obtained : 1. In case of displacement, the amount of displacement was increased at the internal hex type(model C, D) than at the external hex type(model A, B, E) when the vertical and lateral load was applied. 2. Less equivalent stress was represented at the model B with increased external hex height than at the model A when the vertical and lateral load was applied. 3. Much stress was represented at the model E with increased hex angle than at the model A in case of the stress happened to the implant body and the fastening screw when the vertical and lateral load was applied. 4. Much equivalent stress was represented at the model D with deepened internal hex height than at the model C when vertical and lateral load was applied. 5. The least stress was taken at the model B and the most stress was taken at the model D in case of the stress happened to the implant when the vertical and lateral load was applied. 6. The least stress was taken at the model C at the vertical load. And the least stress was taken at the model B at lateral load in case of the stress happened to the fastening screw. As a results of this study, the good lateral stability of prostheses and less stress of the component of implant was taken when the external hex height was increased, and the risk of neck fracture of implant and fastening screw was increased when the internal hex height was deepned because of long screw neck portion and thin implant neck portion.

  • PDF

Characteristics of Sub-cooled Nitrogen Cryogenic System for Applied High-Tc Superconducting Devices (고온초전도 응용기기용 과냉질소 냉각시스템의 냉각특성)

  • 강형구;김형진;배덕권;안민철;윤용수;장호명;고태국
    • Progress in Superconductivity and Cryogenics
    • /
    • v.6 no.1
    • /
    • pp.38-42
    • /
    • 2004
  • The cryogenic system for 6.6 kV/200 A inductive superconducting fault current limiter (SFCL) was developed at Yonsei university in 2003. The sub-cooled nitrogen cryogenic system could be applied to not only SFCL but also many other applied high-Tc superconducting (HTS) devices like superconducting motor, superconducting generator and superconducting magnetic energy storage (SMES). Generally, the cooling capacity of GM-cryocooler depends on the load temperature. Therefore it is necessary to perform the cooling capacity test at no load condition to calculate the exact cooling power and heat load of cryogenic system. In this research, the cooling capacity test of GM-cryocooler was executed and the heat load of developed cryogenic system was calculated. The long run operation test results of sub-cooled nitrogen cryogenic system were successful in pressure and temperature condition. Moreover, the design and fabrication method of cryogenic system were introduced and the test results were described.

Influence of Physical Load on the Stability of Organic Solar Cells with Polymer : Fullerene Bulk Heterojunction Nanolayers

  • Lee, Sooyong;Kim, Hwajeong;Kim, Youngkyoo
    • Current Photovoltaic Research
    • /
    • v.4 no.2
    • /
    • pp.48-53
    • /
    • 2016
  • We report the effect of physical load on the stability of organic solar cells under physical loads. The active layers in organic solar cells were fabricated with bulk heterojunction films (BHJ) films of poly (3-hexylthiophene) and phenyl-$C_{61}$-butyric methyl ester. The loading time was varied up to 60 s by keeping the physical load constant. Results showed that the open circuit voltage was not influenced by the physical load but other solar cell parameters were sensitive to the loading time. The fill factor was very slightly increased at 15 s, while short circuit current density was well kept for 30 s. The power conversion efficiency was reasonably maintained for 45 s but became significantly decreased by the continuous loading for 60 s.

윤활유 첨가제에 따른 마멸분 화상해석

  • 서영백;이충엽;박홍식;전태옥
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.180-189
    • /
    • 1998
  • This paper was undertaken to do shape analysis of wear debris on oiliness agent and extreme pressure agent. The lubricating wear test was performed under different experimental conditions using the wear test device was made in our laboratory and were- specimens of the pin on disk type was rubbed in paraffine series base oil by materials, varying applied load, sliding distance, oil additives such as stearine acid, DBDS, TCP. The four shape parameters (50% volumetric diameter, aspect, roundness and reflectivity) on a kind of the additives are different on applied load and sliding distance and Its are affected by absorbed film and reaction film. DBDS and TCP have a role of extreme pressure agent but a role of absorbed film of stearic acid decrease in high load. The maximum wear volume on applied load be in existence in three kinds of the specimens because of reaction characteristics of the additives.

  • PDF

Traring instability of crack based on J-integral (J-적분을 이용한 균열 찢어짐 불안정성에 관한 연구)

  • Lee, Hong-Seo;Kim, Hui-Song
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.6 no.3
    • /
    • pp.78-89
    • /
    • 1989
  • Applicability of tearing modulus based on J-integral proposed by Paris et al is investigated using compact tension specimens of strutural alloy steel (SCM4). Both general fracture test and instability fracture test are performed. The applied tearing modulus, ( $T_{j}$)app estimated from the real load vs. crack growth curve measured from experiments are compared with that estimated from the limit load vs. crack growth curve. The results are : (1) the $T_{j}$parameter could be applied to predict crack growth instability : (2) The use of ( $T_{j}$)app estimated from the load vs. crack growth curve, proposed in this study could be well predicted crack growth instability instead of that estimated form the limit load vs. crack growth curve.e.

  • PDF

Application of Iterative Learning Control to 2-Mass Resonant System with Initial Position Error (위치 오차를 갖는 2관성 공진계에 대한 반복학습 제어의 적용에 관한 연구)

  • Lee, Hak-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2003.11b
    • /
    • pp.307-310
    • /
    • 2003
  • In this paper, an iterative learning control method is applied to suppress the vibration of a 2-mass system which has a flexible coupling between a load an a motor. More specifically, conditions for the load speed without vibration are derived based on the steady-state condition. And the desired motor position trajectory is synthesized based on the relation between the load and motor speed. Finally, a PD-type learning iterative control law is applied for the desired motor position trajectory. Since the learning law applied for the desired trajectory guarantees the perfect tracking performance, the resulting load speed shows no vibration. In order to handle the initial position error, the PD-type learning law is changed to PID-type and a weight function is added to suppress the residual vibration caused by the initial error. The simulation results show the effectiveness of the proposed learning method.

  • PDF

Effects of Bridge Bearings by Structure-Track Interaction for Continuous Bridge applied CWR with Rail Expansion Joint under Temperature Load (레일신축이음 설치된 장대레일 적용 연속교의 구조물-궤도 상호작용에 의한 온도하중이 교량 받침에 미치는 영향)

  • Chung, Jee-Seung;Lee, Jong-Soon
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.5
    • /
    • pp.54-61
    • /
    • 2010
  • The additional axial force of CWR(continuous welded rail) is occurred by structure-track interaction, in reverse, fixed supports of structure are applied the large load by that. Ratio of load which transferred on support through the bridge superstructure with one-side REJ by acceleration and braking load are stated in High-Speed Rail Design Criteria(2005). On the other hand the horizontal forces of support delivered to the load due to thermal loads has been no report about the criteria. Therefore, this study was performed the review of the reaction and displacement on support by structure-track interaction in a special bridge(composite brdiges, 45+55+55+45=200m) with REJ acting on the temperature load. As a result, because fixed support of a special bridge or a continuous bridge with REJ under the temperature load which is constant load has been acted the large lateral load by structure-track interaction, when determining the fixed bearing capacity of structure should be reflected in the results to secure the safety of structures was confirmed.

Ventilation Load Reduction Plan Using Cool Tube System Case (Cool Tube System 사례를 활용한 환기부하 절감방안)

  • Jeong, Min Yeong;Park, Jin Chul;Yang, Young Kwon
    • Land and Housing Review
    • /
    • v.10 no.1
    • /
    • pp.25-32
    • /
    • 2019
  • In this study, the case analysis data on underground temperature are presented. In addition, numerical analysis of the ventilation load reduction plan was derived according to the residence schedule change for the building with cool tube. The research scope and method are as follows. The overall system principle was examined through reviewing the theory of the Cool tube system. Case study and analysis were conducted. Numerical simulation was used to examine the change in energy usage. Also, the change of load energy in case of varying amount of ventilation was derived based on actual building room schedule. When the Cool tube system was applied to the residential buildings, the cooling load was reduced from 3,331 kW to 193 kW, which showed a reduction effect of about 90%.The heating load was reduced from 42,276kW to 32,575kW by 23%.Also, result shows that the cooling load decreased by 24% and the heating load decreased by 66% when the number of ventilation according to the occupancy schedule was applied.

Analytical Technique and Load Transfer Features on Pile Using Finite Difference Method (유한차분법을 이용한 말뚝의 하중전이특성 및 해석기법)

  • Han, Jung-Geun;Lee, Jae-Ho
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.9 no.5
    • /
    • pp.10-21
    • /
    • 2006
  • For analyze of the bearing capacity, skin friction and settlements of pile on axial compressive loading, both Load transfer tests of pile and pile loading test in field have application to commonly before pile installing. A bearing capacity of pile was affected by the characteristics of surrounding ground of pile. Especially, that is very different because of evaluation of settlement due to each soil conditions of ground depths. The ground characteristics using evaluation of bearing capacity of pile through load transfer analysis depends on N values of SPT, and then a bearing capacity of pile installed soft ground and refilled area may be difficult to rational evaluation. An evaluation of bearing capacity on pile applied axial compressive loading was effected by strength of ground installed pile, unconfined compressive strength at pile tip, pile diameter, rough of excavated surface, confining pressure and deformation modules of rock etc and these are commonly including the unreliability due to slime occurred excavation works. Load transfer characteristics considered ground conditions take charge of load transfer of large diameter pile was investigated through case study applied load transfer tests. To these, matrix analytical technique of load transfer using finite differential equation developed and compared with the results of pile load test.