• Title/Summary/Keyword: Apparent Property

Search Result 177, Processing Time 0.024 seconds

Fluidity and Setting Properties of Cement Paste by Adding of Fluoro Anhydrite and Fly Ash (불산 무수석고와 플라이 애쉬를 첨가한 시멘트 페이스트의 유동성 및 응결특성)

  • 노재성;김도수;홍성수;임계규;임헌성
    • Journal of the Korean Ceramic Society
    • /
    • v.34 no.12
    • /
    • pp.1261-1267
    • /
    • 1997
  • Four kids of powder admixtures(A, B, C, D) based on anhydrite were manufactured by mixing at a fixed rate of II-anhydrite, fly ash and active silica as an industrial by-product. Fluidity properties of cement paste such as mini-slump, apparent viscosity with elapsed time, as well as setting time of cement pastes of these admixtures substituted up to 11wt% of cement were compared to those of cement paste(SS) substisuted by marketed high-strength powder admixture(S). Among these powder admixtures, the fluidity of cement pastes(PA, PC) substituted by A and C powder admixtures manufactured from II-anhydrite and fly ash had an excellent property than that of cement paste substituted by marketed powder admixture and also a good fluidity-retention effect with elapsed time by adding of superplasticizer. The setting time of cement paste substituted by powder admixtures based on anhydrite slightly retarded than that of cement paste substituted by marketed powder admixture.

  • PDF

Characterization of 1,4-Benzoquinone Reductase from Bovine Liver

  • Kim, Kyungsoon
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.7 no.4
    • /
    • pp.216-220
    • /
    • 2002
  • 1,4-Benzoquinone reductase was purified to electrophoretic homogeneity from bovine liver, and the purified enzyme found to have a molecular mass of 29 kDa, as determined by sodium dodecyl sulfate- polyacrylamide gel electrophoresis The enzyme exhibited pH optimum between 8.0 and 8.5. The apparent fm for 1,4-benzoqulnone was 1.643 mM, and the apparent Km for NADH was 1.837 mM. Various divalent cations, such as Hg$\^$2+/, Cu$\^$2+/, and Zn$\^$2+/, exhibited strong inhibitory effects. The enzyme activity was also strongly inhibited by quercetin, dicumarol, and benzoic acid. Incubation of the enzyme with N-bromosuccinimide and pyridoxal 5’-phosphate led to inhibitions of 100% and 99%, respectively. Accordingly, these results suggest that trypto-phan and Iysine residues are Involved at or near the active sites of the enzyme.

Surface Characterization and Dyeing Property of PET Film Treated with Hydrazine Hydrate in Methanol (Hydrazine/Methanol 처리에 의한 PET film의 표면특성과 염색성)

  • 성우경;조현혹;김경환
    • Textile Coloration and Finishing
    • /
    • v.1 no.1
    • /
    • pp.26-34
    • /
    • 1989
  • The selective chemical degradation or etching of PET based on an organic amine attack on the ester group. The techniques involves the chemical removal of loss ordered amorphous regions or crystalline regions, which are essentially unaffected by the degradative etchant. Thus, most of previous studies have limited to consideration which has been given to structural changes taking place. Therefore, this study was carried out to investigate surface characterization, dyeing properties of PET film hydrazinolyzed with hydrazine hydrate in methanol. PET film was treated with 30% hydrazine hydrate in methanol at $30^\circ{C}$ for various time intervals. The total surface tension of treated PET increased, the dispersion force decreased and the hydrogen bonding force increased. The equilibrium dye adsorption, dyeing rate and apparent diffusion coefficient of acid dyes increased, and the apparent activation energies of diffusion decreased.

  • PDF

Evaluation of Apparent Chloride Diffusivity of Types of Concretes (콘크리트 종류별 겉보기 염소이온 확산특성 평가)

  • 문한영;김홍삼;최두선;이승훈;손유신
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.11a
    • /
    • pp.74-77
    • /
    • 2003
  • This paper investigated the apparent chloride diffusivity of various concretes. Ten mixtures of concrete were initially prepared and tested to estimate diffusion property. The penetration depth and concentration of chloride ion were examined at the same water-binder ration. The binders were composed of normal portland cement, fly ash, ground granulated blast-furnace slag, and silica fume. From the results, it was concluded that using the mineral admixtures had a filling effect on the pore structure of cements matrix due to those pozzoanic reaction with the hydrates of cement, which increases the tortuosity of pore and makes large pore finer. And diffusivity of chloride is following: NPC100 > F10N90 > F30N70 > F20N80 > F20S05 > G30N70 > F10S05 > G30S05 > G30F15 > G50N50.

  • PDF

Prediction model for the hydration properties of concrete

  • Chu, Inyeop;Amin, Muhammad Nasir;Kim, Jin-Keun
    • Computers and Concrete
    • /
    • v.12 no.4
    • /
    • pp.377-392
    • /
    • 2013
  • This paper investigates prediction models estimating the hydration properties of concrete, such as the compressive strength, the splitting tensile strength, the elastic modulus,and the autogenous shrinkage. A prediction model is suggested on the basis of an equation that is formulated to predict the compressive strength. Based on the assumption that the apparent activation energy is a characteristic property of concrete, a prediction model for the compressive strength is applied to hydration-related properties. The hydration properties predicted by the model are compared with experimental results, and it is concluded that the prediction model properly estimates the splitting tensile strength, elastic modulus, and autogenous shrinkage as well as the compressive strength of concrete.

Characteristic Experiment of a Hydraulic Control Valve by Using Electro-Rheological Fluid (ERF를 이용한 유압제어밸브의 특성실험)

  • Kim, Dong-Su;Park, Jae-Beom;Jang, Seong-Cheol
    • 연구논문집
    • /
    • s.30
    • /
    • pp.93-99
    • /
    • 2000
  • Electro-Rheological(ER) fluids change their apparent viscosity according to the electric field strength. The electrical and rheological properties of zeolite based the ER fluids were reported. The electric field dependent yield stress are obtained from experimental investigation on the Bingham property of the ER fluid. Using ER fluids, it is possible to directly interface between electric drop and flow rate of the ER fluid was hydraulic control valve measured under application of an electric field. The purpose of the present study is pressure drop measurement of an ER valve by using strain gage. The performance characteristics of the valve system are evalusted in terms of pressrue fixed with respect to the intensity of employed electric fields and flow rates. As a result, it is esperimentally confirmed that pressure control valve using ER fluids applicable to use in hydraulic power systems.

  • PDF

The Apparent Mass Capacity Method for Transient Diffusion Problems with Change of Phase

  • Kim, Yongsoo;Wonmok Jae;D. R. Olander
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.05b
    • /
    • pp.643-650
    • /
    • 1995
  • A numerical method for treating transient diffusion Involving change of phase is presented. In other methods of dealing with this class of problems, the mass flux balance at the moving phase boundary requires explicit treatment of two distinct phases. The technique, originating from the apparent heat capacity method in transient heat conduction with the phase change, avoids the difficulty by transferring the concentration discontinuity at the boundary to smoothed physical property variations near the moving front. This technique accomodates the nonlinearities which preclude use of analytical solutions. It was tested against known analytical solutions for simple cases and turned out to be quite accurate.

  • PDF

Mechanical Property of Foamed Light Weight Concrete with Wasted Expanded Poly-Styrene (폐스티로폼을 혼입한 경량기포콘크리트의 역학적 특성)

  • 오세출;서치호;신상태;김봉주
    • Journal of the Korea Concrete Institute
    • /
    • v.13 no.3
    • /
    • pp.285-293
    • /
    • 2001
  • To improve the vulnerable point and the mechanical property of the existing lightweight foamed concrete, this study was intend to manufacture the lightweight foamed concrete with wasted expanded poly-styrene, examinate and analyze the mechanical property of its. The experiment was being processed with mixing the wasted expanded poly-styrene maximum 40 % by stages and which was mainly basis on the practical mixture. The results of the experiment are following. The flow value is most affected by the mixtured rate of the wasted expanded poly-styrene. The more the mixtured ratio, the less the flow value and the more the more the unit quantity of cement and the W/C, the more the flow value. The apparent specific gravity indicated 0.31∼0.54 and which is seemed to be mainly included in the 0.4 degree and 0.5 degree that are regulated in the KS F 4039. The more the mixtured wasted poly-styrene ratio, the less the apparent specific gravity. The absorbing ratio which was depend on the mixture condition indicated 11 ∼46% and the more the mixtured ratio of the wasted expanded poly-styrene, the less the absorbing ratio remarkably. The compressive strength of the lightweight foamed concrete had a tendency to increase as the mixtured ratio of the wasted poly-styrene, the ratio quantity of cement and the apparent specific gravity increasing but as the ratio of bubble decreasing. The W/C affected little.

Structure and Properties of TLCP/Polyester Composite Fibers

  • Kim, Jun-Young;Kim, Seong-Hun
    • Proceedings of the Korean Fiber Society Conference
    • /
    • 2003.10a
    • /
    • pp.102-102
    • /
    • 2003
  • TLCP/polyester composite fibers (TPCFs) based on melt blends of PEN, PET, and TLCP were prepared by melt blending and spinning process to achieve high performance fibers. Reinforcement effect and TLCP fibrillar structure resulted in improvement of mechanical properties for TPCFs. The increase in the apparent crystallite size was attributed to the development of larger crystallites and more ordered crystalline structures in the annealed TPCFs. Molecular orientation was an important factor to determine mechanical property of TPCFs.

  • PDF

Vibration Analysis and Design of CRT for Reduction of Moire Phenomena (CRT 모아레 현상의 억제를 위한 진동 해석 및 설계)

  • 이규헌;유홍희
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.413-418
    • /
    • 2001
  • The moire phenomena, which are induced by mask vibration due to the excitation of speakers, degrades the color purity of CRT. So it is important to eliminate this phenomena to obtain a good CRT design. In this study we analyze the mask vibration by experiment as well as finite element method. To obtain the finite element solutions efficiently, an equivalent model was employed. The experimental and analysis results show reasonable agreements. An enhanced design configuration of mask welding points are suggested through this study.

  • PDF