• Title/Summary/Keyword: Apex Height

Search Result 60, Processing Time 0.032 seconds

Production of Plug Plantlets for Mass Propagation Using Stem Cuttings of Virus Free Microtubers in Potato (감자 바이러스 무균종묘의 대량생산과 플러그화에 관한 기초 연구)

  • 박양문;소인섭;유장걸;강봉균
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.42 no.6
    • /
    • pp.678-686
    • /
    • 1997
  • This experiment was carried out to develop the mass propagation system for producing plug plantlets using stem cuttings of virus-tree microtubers in potato. Cocopeat, vermiculite, perlite and peatmoss were combined and used as plug nursery media to find out the best combination suitable for the growth of seedlings derived from microtubers. Seedling growth was favored in high temperature (above 2$0^{\circ}C$) and a long-day photoperiod(above 16 hours) condition, while stolons and microtubers formed in outdoor condition. Shoot and root multiplication was not affected by NAA 10mg /1 or IAA 10mg /1 treatment. At the early growth stage of plug plantlets, the number of leaves and roots and the length of root increased significantly when nodes from the upper (near to apex) part of shoots rather than from basal part were taken. But after transplanting, these differences among these characters were not observed. At ninety days after transplanting the plug plantlets in spring time, plant was around 70 to 80cm in height, and the number of stolons and tubers were ten and seven, respectively.

  • PDF

Comparison of anterior maxillary and mandibular alveolar parameters in African American and Caucasian women: A retrospective pilot study

  • Renaud, Lauren;Gandhi, Vaibhav;West, Cailynn;Gudhimella, Sudha;Janakiraman, Nandakumar
    • Imaging Science in Dentistry
    • /
    • v.51 no.2
    • /
    • pp.175-185
    • /
    • 2021
  • Purpose: The primary objective of this study was to analyze the thickness and height of alveolar bone around the maxillary and mandibular incisors. Additionally, this study aimed to compare bone parameters between Caucasian (CC) and African American (AA) female patients. Materials and Methods: In this retrospective pilot study, 50 female subjects(25 CC and 25 AA) were included. The inclusion criteria were AA or CC women between the ages of 18 and 50 with a normo-divergent facial pattern and Angle's class I, end-on class II, or mild class III malocclusion. The distance from the cementoenamel junction (CEJ) to the buccal and lingual alveolar crest; the alveolar ridge thickness at the mid-root and apex; and the buccal and lingual bone thickness at 3, 6, and 9mm from the CEJ were measured. Results: No significant difference was found (P>0.05) in the cortical bone thickness at 3mm, 6mm, or 9mm from the alveolar crest between CC and AA populations for most measurements. A significant difference in bone thickness was found (P<0.05) for the lingual surface of the central incisor, with maxillary bone thickness found to be higher than mandibular bone thickness. The measurements of lingual thickness were larger than those of buccal thickness for both races. Conclusion: There were no differences in maxillomandibular anterior alveolar bone measurements between normo-divergent adult AA and CC women, except for a few parameters at varying locations. However, future studies can be planned based the current pilot study data, which may provide valuable information.

Assessment of alveolar bone changes in response to minimally invasive periodontal surgery: A cone-beam computed tomographic evaluation

  • Solaleh Shahmirzadi;Taraneh Maghsoodi-Zahedi;Sarang Saadat;Husniye Demirturk Kocasarac;Mehrnoosh Rezvan;Rujuta A. Katkar;Madhu K. Nair
    • Imaging Science in Dentistry
    • /
    • v.53 no.1
    • /
    • pp.1-9
    • /
    • 2023
  • Purpose: The aim of this study was to evaluate 3-dimensional cone-beam computed tomography (CBCT) images of alveolar bone changes in patients who underwent minimally invasive periodontal surgery-namely, the pinhole surgical technique (PST). Materials and Methods: Alveolar bone height was measured and compared on CBCT images of 254 teeth from 23 consecutive patients with Miller class I, II, or III recession who had undergone PST. No patient with active periodontal disease was selected for surgery. Two different methods were used to assess the alveolar bone changes postoperatively. In both methods, the distance between the apex of the tooth and the mid-buccal alveolar crestal bone on pre- and post-surgical CBCT studies was measured. Results: An average alveolar bone gain >0.5 mm following PST was identified using CBCT(P=0.05). None of the demographic variables, including sex, age, and time since surgery, had any significant effect on bone gain during follow-up, which ranged from 8 months to 3 years. Conclusion: PST appears to be a promising treatment modality for recession that results in stable clinical outcomes and may lead to some level of resolution on the bone level. More long-term studies must be done to evaluate the impact of this novel technique on bone remodeling and to assess sustained bone levels within a larger study population.

Factors affecting force system of orthodontic loop spring (교정용 loop 스프링의 force system에 영향을 주는 요소)

  • Choy, Kwang-Chul;Kim, Kyung-Ho;Park, Young-Chel
    • The korean journal of orthodontics
    • /
    • v.29 no.5 s.76
    • /
    • pp.511-519
    • /
    • 1999
  • The shape of orthodontic retraction spring was varied and force system of each case was obtained using numerical analysis and verified with spring tester. The factors for obtaining biomechanically efficient spring under anatomic limitation were suggested as follows. 1. M/F ratio increases and L/D rate decreases as loop height increases. 2. M/F ratio increases and L/D rate decreases as incorporating more wire above minimum bending moment area. 3. M/F ratio decreases and L/D rate decrease as incorporating more wire below minimum bending moment area. 4. M/F ratio can not be greater than spring height no matter how much wire is incorporated at the apex of the loop. 5. Additional moment is necessary to obtain enough M/F ratio for translation under anatomical limitation. 6. Additional moment should be incorporated at every pah of the spring because M/F ratio and L/D rate decreases as horizontal spring length increases. 7. Material, cross section, and shape of the spring influence L/D rate, whereas M/F ratio is influenced by the shape of the spring independent from material and cross section.

  • PDF

Morphometric Analysis of Distances between Sacral Hiatus and Conus Medullaris Using Magnetic Resonance Image in Korean Adult (자기공명영상을 이용한 한국 성인의 엉치뼈틈새와 척수원뿔 사이 거리 연구)

  • Park, Tai Soo;Hwang, Byeong-Wook;Park, Sang-Joon;Baek, Sun-Yong;Yoon, Sik
    • Anatomy & Biological Anthropology
    • /
    • v.29 no.4
    • /
    • pp.145-154
    • /
    • 2016
  • The purpose of this study was to provide basic biometric data on Korean adults through magnetic resonance imaging (MRI)-based measurements of the distances between the apex of sacral hiatus (SH) and the termination of dural sac (DS), and between SH and conus medullaris (CM) because they are critical to the performance of epidural neuroplasty. A total of 200 patients(88 males and 112 females) with back pain, who had no spine fracture, significant spinal deformity, and spondyloisthesis were selected for this study. The subjects were of mean age 54.3 (20~84) years and mean height 161.3 cm (135~187). T2-weighted MRI images were used for correlation analysis to evaluate the relationships between the distances, and variables such as sex and height. In all patients, the mean distance between SH and DS was $62.8{\pm}9.4mm$ and the mean distance between SH and CM was $232.2{\pm}21.8mm$. The minimum distance and the maximum distance between SH and DS were 34.8 mm and 93.9 mm respectively, and the minimum distance and the maximum distance between SH and CM were 155.0 mm and 284.0 mm respectively. In female patients, both the distances between the SH and DS, and between SH and CM were shorter when compared to those of the male patients(p<0.05). Both the distances between SH and DS and between SH and CM showed a significant correlation with height(p<0.01). The results of this study will provide a useful biometric data on the distances between SH and DS and between SH and CM in Korean in ensuring clinical safety and in the development of more effective catheterization techniques for epidural neuroplasty in Korean.

A Radiological Study on the Morphology of Labial Alveolar Bone in the Mandibular Incisor Area of Mandibular Prognathism Patients (하악전돌증 환자의 하악전치부 순측 치조골 형태에 관한 방사선학적 연구)

  • Kim, Jeom-Sook;Hwang, Hyeon-Shik
    • The korean journal of orthodontics
    • /
    • v.29 no.2 s.73
    • /
    • pp.209-217
    • /
    • 1999
  • This study was concerned with comparing the measured values of labial alveolar bone through the lateral cephalometric radiography and mandibular incisor cross-sectional tomogram between two groups, one group of mandibular prognathism patients who needed an orthognathic surgery as an experimental group and the other group who had normal molar relationships as a control group. The purpose of the study was to find out the predisposing factor of bone resorption and gingival recession before orthodontic treatment. The results were as follows: 1. The cross-sectional area of labial alveolar bony plate in mandibular prognathism was significantly smaller than that of control group. 2. In mandibular prognathism, the distance between cementoenamel junction and alveolar crest was significantly greater than control group. 3. There were negative correlations between area of labial alveolar bony plate and distance from cementoenamel junction to alveolar crest, and positive correlations between area of labial alveolar bony plate and distance from alveolar crest to root apex. 4. In mandibular prognathism, there were positive correlations between IMPA and thickness of symphysis, and negative correlations between IMPA and the alveolar bony height. The results of the present study suggest the mandibular prognathism patients are prone to the gingival recession due to the small amount of labial alveolar bone around lower incisors.

  • PDF

The Effect of snatch technique improvement for men weightlifter of feedback support through quantity analysis by periods (주기적 정성적분석을 통한 훈련목표 제공이 남자 역도 인상기술 향상에 미치는 영향)

  • Moon, Young-Jin;Ryu, Jung-Hyun;Lee, Soon-Ho
    • Korean Journal of Applied Biomechanics
    • /
    • v.14 no.2
    • /
    • pp.69-83
    • /
    • 2004
  • The purpose of this study is searching for technical merits and demerits of each weight lifting player through qualitative motion analysis system. Moreover, It is also analysis the repeating the establishment of exercise purpose and studying for the effect of the field adaptation. The subject of this study was five male weight lifting players who have been engaged in Korean Delegation Team. The institution of exercise target was made through two times qualitative analysis and the result of studying for the effect of the field adaptation was produced before offering feedback. Moreover, two time analysis added after offering feedback. All analysis was based on 2-D visual analysis. The results of this study are as follows: 1. Maximal barbell moving speed in starting phase was decreased after offering feedback. This result implies advancement of technical skills after offering feedback. 2. From starting posture to 앉아받기, forward and backward moving distance of hip joint was decreased after offering feedback in all subjects. This result represents advancement of technical skills after offering feedback. 3. In terms of pull phase, forward and backward moving distance of hip and shoulder joint was decreased after offering feedback in all subjects. This result represents advancement of technical skills after offering feedback. 4. In terms of pull phase, the difference of horizontal value of coordinates was decreased after offering feedback in all subjects. This result represents advancement of technical skills after offering feedback. 5. In terms of pull phase, the motion range of hip joint was decreased after offering feedback in three of five subjects and this represents advancement of technical skills after offering feedback. However, the rest of them were not variable or narrow decreasing. This result represents that feedback system could not brought tremendous effects. 6. From apex point of barbell to 앉아받기, the difference of barbell height was decreased after offering feedback in three of five subjects and this represents advancement of technical skills after offering feedback. However, the rest of them weren't variable or narrow increasing. This result represents that feedback system could not brought tremendous effects. 7. In terms of last-pull phase, the angular velocity of knee joint was increased after offering feedback in four of five subjects and this represents advancement of technical skills after offering feedback. However, the rest of them, only one subject, decreased. This result represents that feedback system could not brought tremendous effects. 8. In terms of last-pull, the conversional tendency of maximal extension to flextion came out all but simultaneously without offering feedback in four of five subjects. This is well-performed technique. Only one subject, however, could not use power effectively because the fact that his maximal extension came out in serial, from ankle to knee and waist means dispersion of power. In addition to, after offering feedback, only one subject made increasing the maximal extension of knee in last-pull and this result represents advancement of skills after offering feedback. However, the rest of them could not make meaningful development after offering feedback. 9. It might be assumed that searching for technical merits and demerits of each weight lifting player through qualitative motion analysis system could improve player's skill.

FINITE ELEMENT ANALYSIS OF WIDE DIAMETER SCREW IMPLANT PLACED INTO REGENERATED BONE (재생된 골에 식립한 넓은 직경의 나사형 임플란트에 대한 유한요소법적 분석)

  • Kim, Su-Gwan;Kim, Jae-Duk;Kim, Chong-Kwan;Kim, Byung-Ock
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.31 no.3
    • /
    • pp.248-254
    • /
    • 2005
  • The purpose of this study was to investigate the distribution of stress within the regenerated bone surrounding the implant using three dimensional finite element stress analysis method. Using ANSYS software revision 6.0 (IronCAD LLC, USA), a program was written to generate a model simulating a cylindrical block section of the mandible 20 mm in height and 10 mm in diameter. The $5.0{\times}11.5-mm$ screw implant (3i, USA) was used for this study, and was assumed to be 100% osseointegrated. And it was restored with gold crown with resin filling at the central fossa area. The implant was surrounded by the regenerated type IV bone, with 4 mm in width and 7 mm apical to the platform of implant in length. And the regenerated bone was surrounded by type I, type II, and type III bone, respectively. The present study used a fine grid model incorporating elements between 250,820 and 352,494 and nodal points between 47,978 and 67,471. A load of 200N was applied at the 3 points on occlusal surfaces of the restoration, the central fossa, outside point of the central fossa with resin filling into screw hole, and the functional cusp, at a 0 degree angle to the vertical axis of the implant, respectively. The results were as follows: 1. The stress distribution in the regenerated bone-implant interface was highly dependent on both the density of the native bone surrounding the regenerated bone and the loading point. 2. A load of 200N at the buccal cusp produced 5-fold increase in the stress concentration at the neck of the implant and apex of regenerated bone irrespective of surrounding bone density compared to a load of 200N at the central fossa. 3. It was found that stress was more homogeneously distributed along the side of implant when the implant was surrounded by both regenerated bone and native type III bone. In summary, these data indicate that concentration of stress on the implant-regenerated bone interface depends on both the native bone quality surrounding the regenerated bone adjacent to implant and the load direction applied on the prosthesis.

Retrospective studies of dental implant placement at each intraoral site and situation (임플란트 식립 유형에 따른 후향적 연구)

  • Hong, Ji-Youn;Chae, Gyung-Joon;Jung, Ui-Won;Kim, Chang-Sung;Cho, Kyoo-Sung;Chae, Jung-Kiu;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.37 no.4
    • /
    • pp.805-824
    • /
    • 2007
  • Purpose: Developments in micro/macrostructures of implants and surgical techniques brought out stable outcomes of implant dentistry. The aim of this study was to evaluate the distributions of implant patients, the types of implanted sites, and the success or survival rates of various implant systems and to analyze the implant placement done at each specificintraoral site and situation. Materials and Methods: The data of dental implantations collected between 1992 and 2006 at the Department of Periodontology in 00000 University Hospital were analyzed. Results: 1. Largest part of the patients were at the age of 40s and 50s in bothgender who lost their teeth mostly by periodontaldiseases and caries at the posterior intraoral sites as major ones. Bone densities of type II(mandible) and III(maxilla) were likely to be seen with quantity of type B. Lengths of the implants between 10 and 15 mm and wide platform took the largest part. 2. Survival rates of $Implantium^{(R)}(98.8%)$, $Xive^{(R)}(100%)$ and ITI $TE^{(R)}(100%)$ were high when $Frialit-2^{(R)}$ showed 82%(poor bone density area) or 87.2%(combined with additional therapy). $IMZ^{(R)}$ had lowest cumulative survival(67.5%) and success rate(49.4%) amongst all. 3. Replacement with 2 wide or 3 regular platforms showed no significant differences in survival rate and marginal bone loss atmandibular posterior area. In single restoration of mandibular second molar, 5-year success rate of machined surface $Br{\aa}nemark^{(R)}(70.37%)$ was lower than that of rough surface $ITI^{(R)}$ SLA(100%). 4. Replacement of single tooth in anterior area showed high survival rate of 94.5%. 5. The success rates of $Br{\aa}nemark$ Ti-Unite and ITI SLA at posterior maxilla with poor bone density both showed stable outcomes. 6. 10-year cumulative survival rate of implants with maxillary sinus augmentation by lateral window approach appeared to be 96.60%. Low survival rate(75%) was shown when there were more than two complications combined. Height of grafted bone remained stable above the implant apex. Conclusions : Rough surfaced implants showed stable outcomes in most of the situation including poor bone density and additional therapy combined.

Development of a New Cardiac and Torso Phantom for Verifying the Accuracy of Myocardial Perfusion SPECT (심근관류 SPECT 검사의 정확도 검증을 위한 새로운 심장.흉부 팬텀의 개발)

  • Yamamoto, Tomoaki;Kim, Jung-Min;Lee, Ki-Sung;Takayama, Teruhiko;Kitahara, Tadashi
    • Journal of radiological science and technology
    • /
    • v.31 no.4
    • /
    • pp.389-399
    • /
    • 2008
  • Corrections of attenuation, scatter and resolution are important in order to improve the accuracy of single photon emission computed tomography (SPECT) image reconstruction. Especially, the heart movement by respiration and beating cause the errors in the corrections. Myocardial phantom is used to verify the correction methods, but there are many different parts in the current phantoms in actual human body. Therefore the results using a phantom are often considered apart from the clinical data. We developed a new phantom that implements the human body structure around the thorax more faithfully. The new phantom has the small mediastinum which can simulate the structure in which the lung adjoins anterior, lateral and apex of myocardium. The container was made of acrylic and water-equivalent material was used for mediastinum. In addition, solidified polyurethane foam in epoxy resin was used for lung. Five different sizes of myocardium were developed for the quantitative gated SPECT (QGS). The septa of all different cardiac phantoms were designed so that they can be located at the same position. The proposed phantom was attached with liver and gallbladder, the adjustment was respectively possible for the height of them. The volumes of five cardiac ventricles were 150.0, 137.3, 83.1, 42.7 and 38.6ml respectively. The SPECT were performed for the new phantom, and the differences between the images were examined after the correction methods were applied. The three-dimensional tomography of myocardium was well reconstructed, and the subjective evaluations were done to show the difference among the various corrections. We developed the new cardiac and torso phantom, and the difference of various corrections was shown on SPECT images and QGS results.

  • PDF