Residents' Responses and Consciousness on Sick House Syndrome of Newly Built Apartments - Focusing on Cheongju - (신축 아파트 거주자의 새집증후군 반응 및 의식 조사 - 청주시를 중심으로 -)

  • Choi, Yoon-Jung
    • Journal of the Korean Home Economics Association
    • /
    • v.44 no.3 s.217
    • /
    • pp.103-113
    • /
    • 2006
  • The purpose of this study was to determine the present condition of sick house syndrome of newly built apartments a mid-sized city. The questionnaire survey was carried out from $19^{th}\;to\;22^{nd}$ of May 2004, with respondents consisting of 160 households living in two apartment complexes of Cheongju. Their residency periods after moving in were within $six{\sim}ten$ months. From the survey results of the respondents, sick house syndrome items revealed high percentages with the highest value of 49.3%. The respondents answered that they knew relatively well about sick house syndrome but they had no knowledge about 'bake-out'. The response percentages of sick house syndrome items in E complex, consisting of $106m^2$ (32 pyeong) size units, were significantly higher than those in A complex, consisting of $76m^2$ (23 pyeong) size units. This result suggests that the pollution levels emitted from interior materials in larger sized apartment units are higher than those in small sized units. The response percentages of sick house syndrome items in houses with fulfilled ventilation which had been ventilated before or after moving in were lower than in houses not ventilated.

A Study on the Mechanical Ventilation Design that Consider Supply and Exhaust Efficiency of the Apartment House Kitchen (공동주택 주방의 급ㆍ배기효율을 고려한 기계환기 설계에 관한 연구)

  • 함진식
    • Journal of the Korean housing association
    • /
    • v.15 no.3
    • /
    • pp.101-108
    • /
    • 2004
  • To find more efficient exhaust effect, air curtain of upward or downward trend in gas table and left or right side of range hood were made. As result that film vapor from range hood lower part by digital camera, the air current change by moving existence and nonexistence of exhaust fan and direction of air curtain were known. Under all experiment condition, upward air curtain superior exhaust performance.

A numerical Study for Improvement of Indoor Air Quality of Apartment House (공동주택 단지의 실내 공기질 향상을 위한 수치 해석적 연구)

  • Shin, Mi-Soo;Kim, Hey-Suk;Hong, Ji-Eun;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.31 no.7
    • /
    • pp.521-530
    • /
    • 2009
  • This study has been made to execute a research in order to lead the improvement of indoor air quality, examining the indoor ventilation characteristics by using a numerical analysis method. To this end an extensive parametric investigation are made according to various external flow variables such as main wind direction and wind speed by season, building layout design, and location of ventilators, etc. in Daedeok Techno Valley, one of large-scaled apartment in Daejeon. It is observed there was a significant difference of main wind direction between summer and winter. The main wind direction in summer was a south wind, and on the contrary the direction in winter is northnorthwest, which is similar to the average main wind direction for 10 years. One of the important calculation results is that the change of wind direction causes a significant effect on the apartment ventilation by the change of pressure difference around each complex of apartment. In case of favorable area of ventilation, the indoor ventilation rate can meet 0.7 ACH from the standard value only with natural ventilation. On the contrary, in other area the value was much lower than the standard value. If the calculation result applies to the design of layout apartment or placement of ventilators, it will be greatly helpful to the energy saving because it can be parallel with the natural ventilation to help securing ventilation rate, not much depending on the mechanical ventilation.

A Study of Natural Infiltration Phenomenon in Apartment Buildings (공동주택 자연침기현상 측정연구)

  • Chung, Hyung-Ho;Song, Jun-Won;Hong, Goo-Pyo;Park, Cheol-Yong;Kim, Jin-Up;Yang, Kyung-Mo;Lee, Bok-Man
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.944-949
    • /
    • 2006
  • An infiltration was realized as an important part of ventilation to change fresh air with contaminated air in a house. In this study, it was measured the infiltration in new apartment buildings according to Seasons, height etc. We measured the infiltration by using tracer gas method and did for 24hours. To quantify the infiltration, Sulfur Hexafluoride($SF_6$) gas was used. The Constant Concentration was conducted during experimental process and the concentration of the gas was measured with a gas monitor. In the results of the measurement, the infiltration were appeared over 0.6 ACH in winter and about 0.2 ACH in summer and autumn. Also the infiltration were measured more highly at high and low stories than middle stories in winter.

  • PDF

An Analysis of Demand for Environmental Controls on Different Residential Building Types (주거용 건물의 유형에 따른 환경조절요구에 대한 분석)

  • Leigh Seung-Bok;Won Jong-Seo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.10
    • /
    • pp.960-968
    • /
    • 2004
  • One of the most important functions of a building is to provide thermally comfortable indoor environmental conditions for the occupants. Therefore, a great deal of energy is consumed for heating and cooling to satisfy those thermal requirements. In order to provide thermal comfort with minimum heating and cooling energy consumption, optimal design of building affecting indoor climate is required. This study used the TRNSYS for modeling and simulation of the energy flows of residential building types, and examined the energy efficient measures to reduce the thermal loads. The residential building types are classified into the detached house, apartment house and high-rise residential complex. The results of the simulation show that the heating energy consumption in the detached house is especially high, whereas the cooling load is an important determinant in the apartment house and high-rise residential complex. The measures examined are the insulation thickness, various types of glazing, infiltration, natural and controlled ventilation, solar shading, orientation and etc. Comparative evaluations and sensitivity analyses revealed the effects of these variables and identified their energy efficient building design strategies.

A Study on the Elderly Households' Needs for Housing Modification (노인가구 특성에 따른 주거개조요구에 관한 연구)

  • Lee, Kwang-Soo;Park, Soo-Been
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2009.04a
    • /
    • pp.278-283
    • /
    • 2009
  • This study aims to figure out the old people's needs for modification of their housing to maintain an independent lifestyle despite their health status and living arrangements. The total of 438 residents take part in the questionnaire survey research through the quota sampling method grouped by age (60-64 group, 65-69 group, 70-74 group, and over 75 group), sex (male and female), and house type (apartment houses and others). The results are as follows. (1) The old people's most inspired modification needs in interior spaces are remodeling the heating controls in the living room and the bedroom, ventilation facilities and storage spaces in the kitchen, non-slip tile flooring and ventilation facilities in bathroom, an easy door-lock, non-slip tile flooring, a draft cut-off, and storage spaces in the entrance. Besides they require emergency alarm, easy door and window locks, fire and gas alarm, and furniture with easy handling. It is necessary to supply the aged with the appropriate heating controls for their sensitivity to heat, with enough storage spaces for the increased possessions, and with diverse safety systems reflected blunting of mobility and sensibility. (2) As they grow older, the aged require more remote controls and safety facilities such as emergency alarm, easy locks and furniture with distinguishable colors. Male elderly is more concerned with safety, while female elderly do with convenience due to their different time spending in the house. The elderly residents in the apartment houses require the heating controls, a draft cut-off, and storage space less than other types of houses. Thus modification of the heating controls, a draft cut-off, and storage space are regards as basic needs for the elderly residents in non-apartment houses.

  • PDF

Evaluation Method for Improvement Efficiency of Indoor Air Quality in Residence (주택의 실내공기질 개선 평가 방법)

  • Yang, Won-Ho;Son, Bu-Soon;Yim, Sung-Kuk
    • Journal of Environmental Health Sciences
    • /
    • v.33 no.4
    • /
    • pp.255-263
    • /
    • 2007
  • Indoor air quality is the dominant contributor to total personal exposure because most people spend a majority of their time indoors. The purposes of this study were to evaluate the alternative method for improvement of indoor air quality in house after coating titanium dioxide ($TiO_2$) photocatalyst for interior part of the house using nitrogen dioxide ($NO_2$) multiple measurements. To evaluate the alternative method in indoor environment, daily indoor and outdoor $NO_2$ concentrations of an apartment and a detached house were daily measured for consecutive 21 days in winter and summer, respectively, Another daily 21 measurements were carried out after $TiO_2$ coating on wall paper of interior part in houses. All $NO_2$ concentrations were measured by passive filter badges. Indoor air quality models using mass balance are useful tool to quantify the relationship between indoor air pollution levels, ambient concentrations, and explanatory variables. Using a mass balance model and linear regression analysis, penetration factor (ventilation rate divided by sum of ventilation rate and decay rate) and source strength factor (emission rate divided by sum of ventilation rate and decay rate) were calculated. Subsequently, the decay constants were estimated. In this study. magnitude of improvement of indoor air quality could be evaluated by decay constant.

A Study on the amount of Co gas in the kitchen related to facility enviromental condition and fuel management (부엌공기 중에 함유되어 있는 가스량과 부엌 구조시설 연료관리와의 관계에 대한 연구)

  • 장명욱
    • Journal of the Korean Home Economics Association
    • /
    • v.8 no.1
    • /
    • pp.146-158
    • /
    • 1970
  • It is a matter of amazing to realize that contamination of air by fuel gas in recent daily life at home directly effects to health of Korean housewives. A study in finding the status and the amount of co gas in the kitchen was con-ductedrelating the size of kitchen, door of exit, ventilation window, constraction of built in-brick stove (Boo Tu Mack), fuel management, in order to extend beneficial and improved management of housing. From the result of study, it was pointed out that constractional improvement of built-in-brick stove, heating floor (Ondol), timny, and ventilation window would been emergently needed. Demonstration studies were obtained in finding differences of the amount of co gas respectively in cooking time as 50-55ppm, and in not cooking time as 50-80p,p,m in the kitchen both, original and improved. Definite differences were found depend upon the condition with, without, or direction of the ventilation window. In addition to all above results, significant influence on gas pulling power of Ondol tunnel was shown. Many houses of Apartment house for have middle and low income groups been recognized so poor for health as indicated over 100ppm of co gas if window were not opened because of poor ventilation and weak gas pulling power of Ondol tunnel.

  • PDF