• Title/Summary/Keyword: Apartment Supply

Search Result 322, Processing Time 0.024 seconds

Performance Evaluation of Multidrop Chamber Ventilation System in Apartment (공동주택 적용을 위한 다분기챔버 환기 시스템의 성능평가에 관한 연구)

  • Kim, Sung Soo;Sohn, Jang yeul
    • KIEAE Journal
    • /
    • v.9 no.4
    • /
    • pp.17-22
    • /
    • 2009
  • It is common to design the duct branches where to supply the required air flow for individual room in residential apartment house. However it is difficult to adjust the air volume adequately in small air duct branches in residential ventilation system. The purpose of this study is to figure out the performance of Multidrop chamber coupling system for the residential ventilation system. The experiments were designed to simulate apartment of $84m^2$ and established multidrop chamber duct and general duct on the ceiling of the apartment. Distribution performance of air supply rate were evaluated in this experiments. As a result, distribution performance of air supply rate in the general duct is different from designed air supply rate by about 35% ~ 50% and about 10% in the multidrop chamber system. In additional the sound insulation performance of the multidrop chamber system decreased about 20% compared with general duct system. Therefore, the multidrop chamber system is considered to satisfy proper air supply rate of each room and to improve the sound insulation performance in apartment Houses.

Study on the Development of Optimal Heat Supply Control Algorithm in Group Energy Apartment Building According to the Variation of Outdoor Air Temperature (외기온도 변화에 따른 집단에너지 공동주택의 최적 열공급제어 알고리즘 개발에 관한 연구)

  • Byun, Jae-Ki;Lee, Kyu-Ho;Cho, Young-Don;Shin, Jong-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.5
    • /
    • pp.334-341
    • /
    • 2011
  • In the present study, optimal heat supply algorithm which minimize the heat loss through the distribution pipe line in group energy apartment was developed. Variation of heating load of group energy apartment building in accord with the outdoor air temperature was predicted by the heating load-outdoor temperature correlation. Supply water temperature and mass flow rate were controlled to minimize the heat loss through distribution pipe line. District heating apartment building located in Hwaseong city, which has 1,473 households, was selected as the object building for testing the present heat supply a1gorithm. Compared to the previous heat supply system, 10.4% heat loss reduction can be accomplished by employing the present method.

A Study on Factors Affecting the Supply of Apartments in Changwon City (창원시 아파트 공급량에 영향을 미치는 요인에 관한 연구)

  • Sung, Joo-Han
    • Land and Housing Review
    • /
    • v.11 no.4
    • /
    • pp.35-50
    • /
    • 2020
  • The purpose of this study is to examine which factors are important in determining the amount of the apartment supply in Changwon City. Additionally, this study is to examine the changes in the determination of the amount of apartment supply in Changwon by dividing it into before and after 2016 as the city showed a large difference in apartment supply that caused structural changes during this time period. This study shows that the increase in the number of housing construction permits in Changwon before 2016 had a negative impact on the housing market as well as causing a decrease in the supply of apartments in Changwon after 2016. As a result of the shortsighted predictions on the housing market of Changwon from before 2016, it still affects the current housing market as of June 2020. The implication of this study is that through the housing market system of Changwon City, they can take the role as a control tower in Changwon City and propose principles and standards for supply control in order to better predict the demand of the housing market.

A Study on the Ventilation Effect by Establishment Location of Supply Opening and Exhaust Fan of Bathroom in Apartment House (공동주택 화장실의 급기구 및 배기팬 설치 위치에 따른 환기효과에 관한 연구)

  • 함진식
    • Proceeding of Spring/Autumn Annual Conference of KHA
    • /
    • 2002.11a
    • /
    • pp.321-326
    • /
    • 2002
  • To design mechanical ventilation for bathroom of apartment houses where air supply and exhaust are taken Into consideration, mock-ups of ventilation systems, widely used in bathroom of apartment houses with an area of 100$m^2$, were made and installed in a laboratory, These ventilation mock-ups were available for control of air supply and exhaust, and the size of supply openings were 40cm$\times$1cm, 40cm$\times$3cm, 40cm$\times$5cm. They were installed at five positions, spaced 40cm at a height of 25cm from the floor. and the position of exhaust fans were four corners and center Exhaust fan established each one on corner of the ceiling and one in center. As result that measure ventilation effect by each condition, size of hole that supply air is big, and ventilation effect took effect to be good establishment location is low, Also, distance of exhaust fan is far with hole that supply air, ventilation effect took effect by superior thing.

  • PDF

A Study on the Improvement of Ventilation Effectiveness in High-rise Apartment Buildings (초고층 공동주택의 환기효율 개선에 관한 연구)

  • Park, Jin-Chul
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.2
    • /
    • pp.87-94
    • /
    • 2006
  • The efficiency of ventilation system is one of the most important issues of designing ventilation in high-rise apartment buildings. The purpose of this study is to analyze the ventilation efficiency of ventilation system by experimental study using CO2 gas method. The results of this paper can be summarized as follows; (1) An appropriate ventilation including opening planning, mechanical and hybrid system are required. (2) The supply diffuser of ventilation system should be located near the contaminant source. (3) The return grill should be located along with supply diffuser for proper ventilation. and the return grill should be located near or right above the contaminant source. (4) However, the supply location right above the contaminant source has to be avoided. and the supply diffuser should be installed in module with return grill increase ventilation effectiveness.

A Study of Transformation tendency of an Apartment Unit Plan after The Enforcement of Price Deregulation (분양가 자율화이후 공동주택 단위평면의 변화경향에 관한 연구)

  • Ko, Young-Seok;Kweon, Young;Kim, Yong-Sung
    • Proceedings of the Korean Institute of Interior Design Conference
    • /
    • 2003.05a
    • /
    • pp.74-77
    • /
    • 2003
  • After the Enforcement of Price Deregulation of Apartment, Apartment house get down to originality goods, The Housing Market have reorganized the nucleus by a user, have demanding the development for discriminative unit plan. The purpose of this study is that before and after the Price Decontrol of Apartment take part a variety of unit plan, search for transformation factor and analyze into the tendency of the distinction plan of Housing Goods. Before and after the Price Decontrol of Apartment, Apartment unit have analyzed from 85 $m^2$ till 152 $m^2$ private area; ten corporations of civil construction' unit in Seoul and The national capital region supply apartment, will supply apartment. For selected examples, first, unit plan is normalized from the ratio of front to side wall, bay, a Room' organization and a kind of Room, number, and for examples of unit plan of apartment, the examples were analyzed with respect to change of a Room' organization and the number of a room and the ratio of front wall to side wall for item investigated. Finally, I search out course of transformation tendency of an apartment unit plan after Enforcement of Price Deregulation and analyzed a factor. The results of the study are follows, after Enforcement of Price Deregulation, unit plan of apartment lead to change lay out, to secure each family's privacy, to secure feeling for open hearted, tendency of flexibility.

  • PDF

A Study on Participating virtual model house on the web (웹기반 참가형 가상모델하우스에 관한 연구)

  • Woo Sung-Ho
    • Korean Institute of Interior Design Journal
    • /
    • v.14 no.3 s.50
    • /
    • pp.216-223
    • /
    • 2005
  • In this study, we would like to suggest a virtual model house where the users participate in the planning of the apartment directly in order to supply the apartment which is suitable for the fast change of the resident's characterization, multiplication, and preference in this like high-speed information society. The users have various preferences and demands in the high level information society. It is necessary for the architect to communicate with the users in order to suggest the various styles of habitats that one can treat various life style and life cycle which reflects the demand. In addition, the object of this paper is the construction and using of the participating virtual model house that the resident can plan the preferred space design of the main house before moving Into the apartment and change space design of the main house after moving into the apartment following the variety of life style and the changing of life cycle. Regarding the effect of this study, firstly, it is possible to supply the plate type following the user's preference in order to enhance the quality of uniformed type apartment. Secondly, it is possible to maintain and control the high quality building using sharing the building information with planning, construction, maintain, interior, and related company by constructing the database. Thirdly, the unified database which is constructed by XML can supply the effective environment of apartment information exchange between other companies.

Thermal Performance Analysis of Renewable Hybrid heat Supply System for Zero Carbon Green Home of Apartment (공동주택의 제로카본 그린홈을 위한 신재생에너지 하이브리드 열공급 시스템의 열성능 분석)

  • Joo, Hong-Jin;Lee, Kyoung-Ho;Kwak, Hee-Youl
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.451-456
    • /
    • 2012
  • This study was carried out to evaluate thermal performance of the renewable hybrid heat supply system with solar thermal system and wood pellet boiler for Zero Carbon Green home of apartment houses. The hybrid heat supply system was set up at Korea Institute Energy Research in 2011. The system was comprised of the wood pellet boiler unit with heat capacity designed as 20,000 kacal/hr, a evacuated tubular solar collector 3.74 $m^2$ of aperture area at the $20^{\circ}$ install angle, a 0.3 $m^3$ hot water storage tank, a 0.15 $m^3$ hot water storage tank for space heating. Thermal performance tests for one-house of apartment house were carried out by hot water load and heating load in winter season through the hybrid heat supply system. As a result, hot water energy supplied by the hybrid heat supply system was 11kWh in a day. Solar thermal energy portion was 2.99kWh which is 27% of the total hot water energy supply. wood pellet boiler supply portion was 8.017kWh which is 73% of the total hot water energy supply.

  • PDF

A Study on the Mechanical Ventilation System of Bathroom in Apartment House (공동주택 화장실의 기계 환기시스템에 관한 연구)

  • 함진식
    • Journal of the Korean housing association
    • /
    • v.12 no.3
    • /
    • pp.141-148
    • /
    • 2001
  • To design mechanical ventilation for bathroom of apartment houses where air supply and exhaust are taken into consideration, mock-ups of ventilation systems, widely used in bathroom of apartment houses with an area of 100$\textrm{m}^2$, were made and installed in a laboratory. These ventilation mock-ups were available for control of air supply and exhaust, and the sizes of supply openings were 40cm${\times}$1cm, 40cm${\times}$3cm, and 40cm${\times}$5cm. They were installed at five positions, spaced 45cm at a height of 5cm from the floor. The exhaust fan was designed for its operating voltage to be set to five steps(100V, 130V, 150V, 180V and 220V) in order to control its air flow rates. When the size and position of each supply opening were changed with the wind velocity of the exhaust fan set to the step 5, the ventilation rates were measured and analyzed by the concentration decay method of tracer gas method, in order to present an efficient mechanical ventilation system. The results of the study revealed that the ventilations rates would increase in the presence of supply openings, compared to the absence of supply openings, and that the larger the size of the supply opening, the more the ventilation rates. Therefore, it was found necessary to take air supply into consideration.

  • PDF

A Study on the Trend Analysis of the Parking Demands According to the Housing Unit Size at Apartment Complex - Focused on high-rise apartment complexes in Daegu Metropolitan City - (아파트 단지의 세대규모별 주차수요 추세분석에 관한 연구 - 대구광역시 고층분양아파트단지를 중심으로 -)

  • Park Chan-Don
    • Journal of the Korean housing association
    • /
    • v.16 no.1
    • /
    • pp.55-63
    • /
    • 2005
  • The purpose of this study is to find a way of solving on parking problems at apartment complex through the trend analysis research of the parking demands according to the housing unit size. The subjects of this study are high-rise apartment complexes in Daegu city which are constructed within 10 years. The parking demand according to the housing unit size at apartment complexes had been surveyed every July for 4 years from 2000 to 2003. Specially, we knew that the parking demand of $85 m^2$ below sized housing unit at apartment complex was exceeded architectural regulation of parking supply, and the parking demand of $85 m^2$ over sized housing unit at apartment complex was kept within architectural regulation of parking supply. And, the estimating formula that can predict the future parking demand by the trend analysis according to the housing unit size at apartment complexes in Daegu city was gotten through this study. But, in order to get more accurate estimating formula, it should be based on data of funker research and investigation about apartment complexes and it should be studied continuously.