• Title/Summary/Keyword: Apartment Supply

Search Result 322, Processing Time 0.026 seconds

A Numerical Study on the Dynamic Characteristics of Water Hammer Arresters for Building Service Applications (건축설비용 워터햄머흡수기의 동특성에 관한 수치 연구)

  • 노승환;차동진
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.14 no.4
    • /
    • pp.269-277
    • /
    • 2002
  • Dynamic characteristics of water hammer arresters installed in a building water supply system have been investigated numerically by utilizing a commercial rode that employs the method of characteristics. Some preliminary results with those arresters produced in this study agree well with the previously reported. Then, the arresters have been incorporated into a water supply pipe system of a $59m^2$ apartment unit constructed by a leading construction company, and their dynamic characteristics, especially on the reduction in the water hammer pressure, are investigated. It is found that the setting of the arresters in the pipe system, which is recommended by the company, may not be proper for reducing the pressure to less than 1082.0 kPa when buick-closure valves in the pipe system are closed within 30 ms at the static pressure of 542.6 kPa. More arresters in the system may be required to meet a pressure criteria.

Hybrid Uninterruptible Power Supply for Apartment Housing (공동주택용 하이브리드 무정전전원장치)

  • Lim, Seung-Beom;Lee, Won-Il;Kim, Myeong-Soo;Hong, Soon-Chan
    • Proceedings of the KIPE Conference
    • /
    • 2015.07a
    • /
    • pp.530-531
    • /
    • 2015
  • 본 논문에서는 공동주택용 하이브리드 무정전전원장치(UPS: Uninterruptible Power Supply)를 제안한다. 제안한 하이브리드 UPS는 기존의 UPS 시스템에 DC/DC 컨버터를 추가하여 태양광 패널과 연결 가능하여 기존의 태양광 PCS(Power Conditioning Supply)의 기능을 할 수 있다. 또한 정류기를 양방향으로 동작시켜 피크 부하시나 전력 부족시 전력을 전원단으로 회생시킬 수 있어 기존의 ESS(Energy Storage System) PCS 기능도 할 수 있다.

  • PDF

Dynamic Characteristics of Water Hammer Arresters for Building Service Applications

  • Cha, Dong-Jin
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.1
    • /
    • pp.40-49
    • /
    • 2003
  • Dynamic characteristics of water hammer arresters installed in a building water supply system have been investigated numerically by utilizing a commercial code that employs the method of characteristics. Some preliminary results with those arrester models produced in this study agree well with the previously reported. Then, the arrester models have been incorporated into a water supply pipe system of a 59 $m^2$apartment unit constructed by a leading construction company, and their dynamic characteristics have been investigated, especially on the reduction in the water hammer pressure. It is found that the setting of the arresters in the pipe system, which is recommended by the company, may not be proper for reducing the pressure down below 1,082.0 kPa (10.0 kg$g_f$/$cm^2$) when quick-closure valves in the pipe system are closed within 30 ms at the static pressure of 542.6 kPa (4.5 kg$g_f$/$cm^2$). More arresters in the system may be required to meet pressure criteria stated on the related standards and codes.

Study on the Characteristics of Gray Water from an Apartment Complex for Reuse (재이용을 위한 공동주택 Gray Water의 특성 연구)

  • Park, Su Jeong;Kwon, Oh Sang;Tanaka, Hiroaki;Kim, Chang Soo;Kim, Eun Seok;Kim, Ji Hye;Jang, Seok Jea;Ahn, Kyung Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.29 no.6
    • /
    • pp.847-851
    • /
    • 2013
  • This study describes the results of an investigation conducted in order to characterize the quantity and quality of individual gray water streams. The highest pollutants concentrations were found in gray water originating from kitchen and laundry with $BOD_5$ concentrations in the order of several hundreds $mgl^{-1}$. In contrast to this, bathroom was regarded as a major contributor of Escherichia coli. Laundry gray water has higher pH, sodium, sulfate, anionic surfactants. Individual gray water types had different contribution to the overall daily discharge and relative pollutants loads. Kitchen, although accounting for only 13% of the total volume, was identified as a major source of microorganisms with Total coliforms, Escherichia coli, Fecal streptococcus taking up 82%, 74% and 54% of their relative daily load, respectively. The laundry gray water, although being responsible for 36% of the total daily discharge, was established as a significant contributor of sodium, sulfate, anionic surfactants and TOC (70%, 72%, 84% and 52%, respectively). But the laundry gray water was a minor source of microorganisms. Bathroom was found to be a major gray water producer, making up 51% of the flow, but constituted less than 50% of the relative daily load in most cases.

A Study on the Electrical Load Matching Analisys for the optimal utilization of grid-conntected PV system in Apartment Complex (공동주택의 태양광시스템 적용성 평가를 위한 전기부하 매칭 해석연구)

  • Yoon, Jong-Ho;Park, Jae-Sung;Shin, U-Cheul;Park, Jae-Wan
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.49-54
    • /
    • 2008
  • This study is to investigate an optimal size and position of PV system for apartment complex enough the electrical load matching analysis. The 4 types of arrangements of apartment buildings are considered as follows; ㅡtype, alternative ㅡtype, ㄱtype and ㅁtype. We assume that the studied site is composed of 9 buildings. Firstly, solar access evaluation of roof and facade in apartment buildings was performing with the hourly simulations of total received insolation on each surface considering the hading effect of buildings. Electrical load profile of typical Korean apartments was investigated for the lad matching analysis. To calculate an annual total PV output, we used MERIT program which is a sourly based load matching tool developed by ESRU. TRY weather data of Daejeon are applied for this analysis. Result shows that approximately 11% of total electric load of the site can be supplied by the PV system in the case of full installation of PV system at the whole south-face roof area of 9 buildings in this stuided apartment complex. Depending of a various installation option of roof and facade area, the possible ratio of PV supply in total electrical load varies from 9% to 42%. Among the 4 arrangement types, the ㅡ type revealed the best option for the maximum output of PV system.

  • PDF

A Study of the Development of Apartment's Structural Cost Saving Checklist through the Case Research (사례분석을 통한 공동주택 골조공사의 원가절감 체크리스트 개발에 관한 연구)

  • Lee, Kyeong-Seob;Suh, Sang-Wook
    • Korean Journal of Construction Engineering and Management
    • /
    • v.11 no.6
    • /
    • pp.65-77
    • /
    • 2010
  • Our nation's housing construction is given much weight over 32% in 2007 and especially apartment is taking over 67%. If we put into construction environment consideration, we are having a trouble with price cap policy and the realestate recession due to the global economic crisis. So in order to get competitive power and supply of cheap apartment, the necessity of cost saving is increasing. This research collected the past constructed apartment project's cost saving examples which were influencing on the construction cost, quality and time. We analyzed collected cost saving datum and assorted these in compliance with classification system. By analysis of correlation among datum with exclusion and integration, we make a propose cost saving Checklist that will be a base data to give a chance to use in working level and other research.

A Study on the Power Saving Fraction of Site Electrical Load depending on the installation area of PV system in Apartment Complex (공동주택 단지 배치유형별 PV시스템 최적 설치면적 및 전기부하 기여율 평가 연구)

  • Yoon, Jong-Ho;Park, Jae-Sung;Shin, U-Cheul
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.3
    • /
    • pp.60-66
    • /
    • 2008
  • This study is to investigate an optimal size and position of PV system for apartment complex through the electrical load matching analysis. The 4 types of arrangements of apartment buildings are considered as follows; ㅡtype, alternative ㅡtype, ㄱtype and ㅁtype. We assume that the studied site is composed of 9 buildings. Firstly, solar access evaluation of roof and facade in apartment buildings was performed with the hourly simulations of total received insolation on each surface considering the shading effect of buildings. Electrical load profile of typical Korean apartments were investigated for the load matching analysis. To calculate an annual total PV output, we used MERIT program which is a hourly based load matching tool developed by ESRD. TRY weather data of Daejeon are applied for this analysis. Result shows that approximately 11% of total electric load of the site can be supplied by the PV system in the case of full installation of PV system at the whole south-face roof area of 9 buildings in this stuided apartment complex. Depending on a various installation option of roof and facade area, the possible ratio of PV supply in total electrical load varies from 9% to 42%. Among the 4 arrangement types, the ㅡtype revealed the best option for the maximum output of PV system.

The Direction of Public Rental Apartment Supported by Community Service Viewed from the Livable Community - A Qualitative Comparison Study on the Rental Apartment in Seoul and ST. Paul - (살기 좋은 지역 만들기 관점에서 본 생활지원서비스와 연계한 공공 임대아파트의 방향 - 서울 SH공사 아파트와 미국 세인트폴 시 PHA 아파트의 질적 연구 -)

  • Shin, Kyung-Joo;Jang, Sang-Ock
    • Journal of the Korean housing association
    • /
    • v.18 no.6
    • /
    • pp.25-34
    • /
    • 2007
  • The purpose of this qualitative research is to compare the community service and situation of SH apartment in Yangcheon-Gu and PHA apartment in Minnesota in order to grasp the requirement for livable community. For the study, depth-interview method was used to collect the data. Throughout this research, we found the ways to create a livable community as follows: Rental apartments are supplied by Seoul Housing agency in Korea while in US by PHA, an independent government agency. Both of them are in direct management. There are five main topics to be discussed. First, as a main supplier of services, it is Yangchun-Gu's social welfare center in Korea, while PHA in US. Second, as a mean of giving services, Korean residents visit the welfare center. On the other hand, PHA apartments enforces service-to-customer policies. Third, as a Korean service, they are consultation targeting families, children, teenagers, disabled, olds, education, medical examinations, rehabilitation and free meals. In US PHA apartments, they are medical health professionals, social worker, beauty salon or barber shop, bus to shopping area, bookmobile, OK card program, CHSP, ASI, ALP, personal care, senior/congregate dinning and etc. Fourth, both Korean and US have same hindrance for the 'livable community' policies which is funding and conflict of residents. Fifth, both Korean and US think that the key for the success of 'livable community' are resources, service and residents. The differences between Korea and US concerning service conditions such as supply of rental apartments, management and services are caused by cultural, ethnic and economical differences. From another point of view, Korean apartments are predicted to have similar problems like PHA apartments, and preparative attitude for this is needed.

A Study for Smart Apartment for Supporting Intelligent Service based on Ubiquitous (유비쿼터스 기반의 지능형 서비스를 지원하는 스마트 아파트 연구)

  • Ahn, Byeong-Tae;Lee, Chong-Ha;Chung, Bhum-suk
    • Management & Information Systems Review
    • /
    • v.32 no.3
    • /
    • pp.247-261
    • /
    • 2013
  • Recently, the smart phone, a carrying along terminal connection technology such as Galaxytap/iPad etc. evolves, and supply is increasing rapidly, is included for smart phone because various sensor technologies are developed and service application that is acted in terminal with this is accompanied and grow. Continuously 4 generation to 3 Gs, Wibro Wireless network technology of communications a LTE technology from that is constructed, environment for Ubiquitous realization is being constructed fast. Therefore, in this paper it can inquire state of electronic, furniture devices through apartment complex web server and gear that control groove network at smart phone, and control, and confirms home state prevention of crimes state, and video inquiry of position that CCTV is placed in apartment complex was available. And it proposed integrated smart apartment with parking system and medical system using RFID system in ubiquitous environment.

  • PDF

Analysis of Infiltration of Outdoor Particulate Matter into Apartment Buildings (외기 중 미세먼지의 공동주택 실내 유입에 관한 연구)

  • Bang, Jong-Il;Jo, Seong-Min;Sung, Min-Ki
    • Journal of the Architectural Institute of Korea Structure & Construction
    • /
    • v.34 no.1
    • /
    • pp.61-68
    • /
    • 2018
  • Recently, concentration of fine and ultra-fine particulate matter(PM) has been increased in KOREA. The increase of PM in KOREA is due to increase of domestic industries and yellow dust from china. PM is known to cause diseases such as dyspnoea, asthma, arrhythmia. Since PM is harmful to human, KOREA Ministry of Environment(ME) warns people to stay indoors when the outdoor PM concentration is high. However, prior studies has shown that indoor PM concentration can be relatively high when outdoor PM concentration is high due to infiltration of PM into buildings though leakage areas. In this study, airtightness, indoor and outdoor pressure difference and PM 2.5 & 10 concentration were measured in an apartment complex to observe PM infiltrating into building. Field measurement was conducted in newly-built apartment buildings to avoid the influence of indoor PM which can be generated by residents. The airtightness test was conducted to identify the leakage areas of the apartment, such as electric outlets and supply/exhaust diffusers. The airtightness test result showed that the air leakage area of the building was dominant in buildings envelop. According to indoor and outdoor pressure difference measurement result and PM concentration measurement result, it can be concluded that outdoor PM can infiltrate into indoor by leakage areas when wind is blown toward the apartment. As a result, pressure difference formed by the external weather condition and architectural characteristics such as the airtightness in building can influence PM to infiltrate into buildings. In further studies, I/O ratio, stack-effect, infiltration and penetration factor will be considered.