• 제목/요약/키워드: Apartment Building Height

검색결과 68건 처리시간 0.029초

공동주택에 의한 인접지역의 일조 및 조망 영향에 관한 연구 - 건물 높이 변화를 중심으로 - (A Study on the Impact Factor of Sunlight and View by Apartment Building in its Neighboring Area (focused on the variation of building height))

  • 김용이;최정민
    • 한국주거학회논문집
    • /
    • 제14권6호
    • /
    • pp.51-58
    • /
    • 2003
  • When apartment buildings are builed and re-builded, they tends to be taller. This tendency causes the problems for solar access and view in the neighboring area. So the impact factor of sunlight and view by apartment building in its neighboring area is examined. The results of this study are as follows: When analyzing sky view by dividing the sky vault into the differential area, the analysis of view can be efficient. The shorter the apartment building, the more the continuous solar access time. And the taller the building, the more the accumulated solar access time. As the height of building is taller and it is farther from the border of apartment building, view ratio, sky view ratio, and form ratio are increased. It implies that the slimmer the building, the more the visual environment can be improved.

공동주택 평균층수 적용에 따른 경관영향 분석 및 제도운용 개선방안 연구 (A Study on the Improvement of Average Floor Height Ordinance through Analyzing Landscape Impacts of Average Floor Height System Applied to Apartment Buildings in Residential Areas of Seoul)

  • 목정훈;김성훈
    • 한국조경학회지
    • /
    • 제35권3호
    • /
    • pp.62-70
    • /
    • 2007
  • The purpose of this research is to suggest an improved method of how to apply and operate an average floor height system to rebuilt or redeveloped apartment buildings in general residential areas of Seoul. This research suggested two research findings by a computer simulation study for analyzing the difference between the average floor height of apartment buildings in experimental sites and the average of floors of buildings near experimental sites. The first finding is that an average floor height system should be applied to apartment buildings with a limitation of maximum height at sites larger than $12,000m^2$ in order to control the difference of the maximum height of buildings between apartment sites and their surroundings. The second finding is that the average floor height system should be operated by an appropriate average floor height ratio at sites greater than $50,000m^2$ in order to harmonize rebuilt or redeveloped apartment buildings with their surroundings.

지방 소도시 아파트의 특성 및 경관 인식에 관한 연구 - 전라남도 지역을 중심으로 - (A Study on Characteristic of Apartment Houses and Understanding of Landscape Located at Small town - Centering of Jeollanamdo -)

  • 김윤학;정영덕;유창균;조용준;정진환
    • 한국주거학회논문집
    • /
    • 제18권1호
    • /
    • pp.43-51
    • /
    • 2007
  • This study examines and analyzes view hindrance factors of high-storied apartment houses at small town like 'Eup' where county office locates and it is found that hindrance factors include designation of residential area and height, length and form of main building. On recognition of view, most subjects of research considered high-storied apartment houses hindered urban view and its regulation is needed. Apartment houses at small cities become main factors of hindering urban view because they were located randomly regardless of scale of city and surrounding situation, but there is no measure to control it. Accordingly, view control through enaction of regulations is urgently needed with establishment of guidelines such as height of large buildings including high-storied apartment houses, length of main building, location and regulation of exterior design.

벽식 아파트의 주동 형태 및 규모에 따른 발파해체공법 분류 (Classification of Explosive Demolition Methods Based on the Building Type and Dimension of Wall-slab Apartment Building)

  • 박훈;석철기
    • 화약ㆍ발파
    • /
    • 제27권2호
    • /
    • pp.19-25
    • /
    • 2009
  • 벽식구조 아파트에 대한 재개발의 수요가 증가함에 따라 RC구조 아파트와는 다른 새로운 해체기술이 요구되고 있다. 본 연구에서는 벽식구조 아파트의 발파해체를 위한 기초적인 자료를 제공하기 위해 실시설계 도면을 토대로 벽식구조 아파트를 주동 형태 및 규모에 따라 분류하고, 아파트의 높이(H), 폭(B), 길이(L)의 발파 패턴 요소를 이용하여 벽식구조 아파트의 발파해체에 적합한 발파해체공법을 분석하였다.

건물 지붕 구조를 활용한 건물일체형 풍력발전시스템의 성능 예측 (Pitched Roof-Building Integrated Wind Turbine System Performance Estimation)

  • 최형식;장호남
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 추계학술대회 논문집
    • /
    • pp.324-327
    • /
    • 2008
  • We simulated the performance improvement of a wind turbine installed on the pitched roof-building(apartment in urban area, 50m height). A nozzle shape wind guide is added on the roof of a model apartment. The nozzle-diifuser structure effects for the free stream wind (average 4m/s, 50m height in Incheon) is studied by a basic CFD analysis. This paper examines the effects of roof structure on the wind velocity and the wind distortion effects by a front building. The possible wind power generation capacity on building roof in urban is calculated.

  • PDF

판상형 공동주택의 동 배치 및 종횡비에 따른 풍압계수 특성에 관한 연구 (A Study on the Wind Pressure Coefficients of Flat-type Apartment Complexes Considering Building Layout and Aspect Ratio)

  • 윤성훈
    • 한국융합학회논문지
    • /
    • 제12권9호
    • /
    • pp.153-159
    • /
    • 2021
  • 건축물의 환기성능 평가를 위한 모델링 과정에서 핵심 경계조건으로 활용되는 풍압계수는 통상 저층형 단일 건물에 대해서만 자료화되어 있어, 공동주택 단지와 같은 고층형 집합주택의 모델링 시에는 적용할 수 없다. 이에 본 연구에서는 CFD(Computational Fluid Dynamics)해석을 통해 건물의 배치 및 종횡비가 다른 판상형 공동주택에 대하여 풍향각에 따른 풍압계수의 특성을 분석하고 유형화함으로써 환기 모델링 시 참고할 수 있는 기초자료를 제시하였다. 풍향각 0도의 경우 가장 풍상측에 위치한 건물의 정면에서는 좌우가 반전된 S자 형태의 풍압계수 분포가 나타났으며, 최하층, 최상층 및 2개의 변곡점에 해당하는 풍압계수는 건물의 높이와 관계없이 비교적 근사한 값을 보였다. 저층부의 변곡점은 약 11m 높이에 형성되었으며, 고층부 변곡점의 높이는 건물의 높이에 비례하는 추세식을 통해 산출가능함을 확인하였다. 또한 풍향각 45도 조건을 제외하면 대부분의 조건에서 풍압계수의 평균값을 적용 가능함을 확인하였다.

부산 아파트 단지 배치형태 변화의 요인과 과정에 관한 연구 (Determinants and Processes of Morphological Transformation of Apartment Complexes in Busan)

  • 이상진;박소현
    • 대한건축학회논문집:계획계
    • /
    • 제35권3호
    • /
    • pp.91-102
    • /
    • 2019
  • This study explores the causes and processes of morphological transformation of apartment complexes in Busan. All apartment complexes built until the year 2016 were selected for statistical analysis, drawing/map examination, field observation, selected expert interviews based on 6 periodical groups: Period I(~1990), Period II(1991~1995), Period III(1996~2000), Period IV(2001~2005), Period V(2006~2010), and Period VI(2011~2016). The research argues for three 'arrangement' types, P1U, L1U and P2U, which have dominated the whole periods occupying 88% of the total 260 complexes. The switch of the leading type represents for morphological transformation of apartment complexes. Four aspects, density(F.A.R.), height(maximum number of floors), deformed-building-type ratio, and building-orientation, have affected the change of 'arrangement' types. Density was the major cause of the arrangement-type switch, from P1U to L1U, on Period II(1991~1995). The morphological change, from type L1U to P2U, on Period V(2006~2010) was caused by height and orientation, and is correlated with the increased number of deformed-type buildings. The first phase morphological change on Period II(1991~1995) was resulted by the supply side of apartment. However, the second phase transformation on Period V(2006~2010) had gone through the complex process including reflection of consumers' demands. The significance of research is to reveal the morphological transformation process of apartment complexes through analytical investigation of the entire apartment data in Busan. The result shows that the major change of urban paysage started to occur from Period V(2006~2010), and the superficial evaluation on apartment 'being monotonous and repetitive' may not be proper at least from the perspective of town plan.

아파트 단지내의 열섬효과가 대기오염물질 확산에 미치는 영향 해석을 위한 열유동장 수치모의 (A Numerical Simulation of Heat Flow Field for Heat Island Effect Analysis to Air Pollutants Dispersion in Apartment Complex)

  • 장은숙
    • 한국환경과학회지
    • /
    • 제14권6호
    • /
    • pp.577-582
    • /
    • 2005
  • Enormous apartment complexes in urban areas, temporary inversion state and heat island effect occur due to the strong sunshine and weak wind speeds which hinders the dispersion of air pollutants that are emitted from neighboring areas of apartment complexes. In this study, analysis were conducted by using the Fluent code based on the CFD(Computation Fluid Dynamics), including building layout, material, building height from the ground surface, the heat, analysis of flow field in the apartment complex. It was estimated that the temporal radiation inversion phenomenon during the daytime, which was caused by the weak wind speed and higher temperatures in the upper level, contributed to the stagnation of the air pollutants in the lower layer of the apartment complex.

고층 아파트에서 응축기 적층문제 분석 (Analysis of the Condenser Stack Effect in a High-Rise Apartment Building)

  • 최석호;이관수;김인규;이동혁
    • 설비공학논문집
    • /
    • 제16권9호
    • /
    • pp.796-803
    • /
    • 2004
  • The stack effect of a new type condenser installed in a high-rise apartment building was studied numerically A sirocco fan is introduced to the new type condenser instead of an axial flow In. The new type condenser intakes the cold air through the lower inlet and exhausts the hot air through the upper outlet. The effects of the building height and frontal wind on the performance of an air-conditioner were analyzed. The performance of an air-conditioner was evaluated by using COP (coefficient of performance) and CGPI (condenser group performance indicator). the hot air was exhausted by the new type condenser at an angle of 50$^{\circ}$ from the outer wall of the building. If there was no draft, the new type condenser installed in the high-rise apartment building had a good performance and its performance on each floor is not influenced by the stack effect. It is shown that the efficiency of the air-conditioner installed in several floors below the top floor decreased when the frontal wind velocity was greater than 8 m/s.

기초지반강성을 고려한 벽식구조 아파트의 지진응답에 관한 연구 (Study on Seismic Response of Wall-Slab Apartment Building Sturucture Considering the Stiffnesses of a Foundation-Soil System)

  • 김지원
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.167-175
    • /
    • 2000
  • Seismic analyses of structures can`t be performed without considering the effect of soil-structure interaction and seismic responses of a structure taking into account the stiffnesses of a foundation-soil system show a significant difference from those with a rigid base. However, current seismic analyses of apartment building structures were carried out assuming a rigid base and ignoring the characteristics of a foundation and the properties of the underlying soil. In this study, seismic analyses of apartment buildings of a particular wall-slab structural type were carried out comparing seismic response spectra of a flexible base with those of a rigid base and UBC-97. Wall-slab type low-rise or mid-height apartment buildings built on the deep soil layer showed a rigid body motion with the reduced seismic responses due to the base isolation effect, indicating that it is too safe but uneconomical to utilize the design spectra of UBC-97 for the seismic analysis of a wall-slab type apartment buildings due to the too conservative design.

  • PDF