• Title/Summary/Keyword: Aortic disease

Search Result 463, Processing Time 0.021 seconds

Mitral and Aortic Valce Replacement with Patch Enlargement of Narrow Aortic Annulus (협소한 대동맥판윤의 첨포확대후 대동맥 및 승모판막 대치술 치험 1예)

  • 강면식
    • Journal of Chest Surgery
    • /
    • v.12 no.1
    • /
    • pp.56-60
    • /
    • 1979
  • Replacement of the aortic valve in a normal or large aortic root can be accomplished with ease and safety in most instances. The presence of a narrowed aortic annulus remains a problem in that the replaced smaller prosthetic valve has a significant resting pressure gradient across the orifice. This narrowing causes not only technical difficulties, but also increased mortality and post-op. complication. Therefore this problem deserves special attention. This report presents our experience with a case of a small aortic root caused by rheumatic heart disease [AI and MS]. This is the method of enlargement of the aortic annulus with a woven Dacron patch and replacement of a larger prosthetic aortic valve combined with mitral valve replacement.

  • PDF

Aortic Valve Replacement for Aortic Stenosis and Concomitant Coronary Artery Bypass: Long-term Outcomes and Predictors of Mortality

  • Cho, Won-Chul;Yoo, Dong-Gon;Kim, Joon-Bum;Lee, Jae-Won;Choo, Suk-Jung;Jung, Sung-Ho;Chung, Cheol-Hyun
    • Journal of Chest Surgery
    • /
    • v.44 no.2
    • /
    • pp.131-136
    • /
    • 2011
  • Background: We evaluated the surgical results and predictors of long-term survival in patients who underwent coronary artery bypass grafting (CABG) at the time of an aortic valve replacement (AVR) due to aortic stenosis. Materials and Methods: Between January 1990 and December 2009, 183 consecutive patients underwent CABG and concomitant aortic valve replacement for aortic stenosis. The mean follow-up period was $59.8{\pm}3.3$ months and follow-up was possible in 98.3% of cases. Predictors of mortality were determined by Cox regression analysis. Results: There were 5 (2.7%) in-hospital deaths. Follow-up of the in-hospital survivors documented late survival rates of 91.5%, 74.8%, and 59.6% at 1, 5, and 10 postoperative years, respectively. Age (p<0.001), a glomerular filtration rate (GFR) less than 60 mL/min (p=0.006), and left ventricular (LV) mass (p<0.001) were significant predictors of mortality in the multivariate analysis. Conclusion: The surgical results and long-term survival of aortic valve replacement with concomitant CABG in patients with aortic stenosis and coronary artery disease were acceptable. Age, a GFR less than 60 mL/min, and LV mass were significant predictors of mortality.

Supravalvular Aortic Stenosis Williams-Barrat-Boyes-Lowe syndrome A Case Report (대동맥판상 협착증 [Williams 증후군] 치험 1례)

  • Lee, Jae-Seong;Sin, Gi-U;Choe, Sun-Ho
    • Journal of Chest Surgery
    • /
    • v.18 no.4
    • /
    • pp.615-622
    • /
    • 1985
  • Supravalvular aortic stenosis was relatively uncommon form of congenital heart disease. This patient had typical "elfin faces" with mental retardation, and supravalvular aortic stenosis. The diagnosis was confirmed by pressure tracing obtained at retrograde left heart catheterization and aortography. The type of supravalvular aortic stenosis was localized hourglass narrowing, which was treated by insertion of prosthetic gusset placed across the area of narrowing under the cardiopulmonary bypass.ry bypass.

  • PDF

A Giant Pseudo-Aneurysm on the Anastomosis Site for a Redo Bentall Operation due to Behçet Disease Treated by Thoracic Endovascular Aortic Aneurysm Repair with a Custom-Made Stent Graft

  • Won, Jongyun;Jung, Jae Seung;Lee, Jun Hee;Jung, Young Ki;Son, Ho Sung
    • Journal of Chest Surgery
    • /
    • v.53 no.6
    • /
    • pp.411-413
    • /
    • 2020
  • A 34-year-old man who had undergone aortic valve replacement 8 years ago underwent an additional Bentall operation due to mechanical valve dehiscence 2 years later. Subsequently, he was diagnosed with Behçet disease and Batter syndrome. A week after being hospitalized again due to chest pain and dyspnea, a large pseudo-aneurysm was detected on computed tomography. Because of the excessively large size of the pseudo-aneurysm, surgical treatment seemed very risky. Therefore, we planned to perform thoracic endovascular aortic repair (TEVAR) and treated him successfully. However, the patient experienced recurrence of the same symptoms 4 months later, and was found to have type IV endoleak. He received a TEVAR procedure again, and it was successful.

Congenital Quadricuspid Aortic Valve Disease (선천성 사엽성 대동맥 판막 질환)

  • Park Chan Beom;Kim Jae Jun;Jo Min Seop;Jin Ung;Cho Deog-Gon;Park Kuhn;Cho Kyu-Do;Kim Chi Kyung
    • Journal of Chest Surgery
    • /
    • v.38 no.11 s.256
    • /
    • pp.780-782
    • /
    • 2005
  • The quadricuspid aortic valve is a rare congenital cardiac morphology. In regard to the hemodynamics of the quadricuspid aortic valve, the regurgitation is most common, the regurgitation accompanying the stenosis or pure stenosis are rare. We report hear a case with quadricuspid aortic valve disease which has been known to be extremely rare.

Valve Sparing Aortic Root Replacement in Children with Loeys-Dietz Syndrome

  • Sim, Hyung-Tae;Seo, Dong Ju;Yu, Jeong Jin;Baek, Jae Suk;Goo, Hyn Woo;Park, Jeong-Jun
    • Journal of Chest Surgery
    • /
    • v.48 no.4
    • /
    • pp.272-276
    • /
    • 2015
  • Loeys-Dietz syndrome (LDS) is an autosomal dominant connective tissue disorder that is characterized by aggressive arterial and aortic disease, often involving the formation of aortic aneurysms. We describe the cases of two children with LDS who were diagnosed with aortic root aneurysms and successfully treated by valve-sparing aortic root replacement (VSRR) with a Valsalva graft. VSRR is a safe and suitable operation for children that avoids prosthetic valve replacement.

Florida Sleeve Repair for Aortic Root Aneurysm

  • Kim, Dong Hee;Kim, Kwan Sic;Kim, Joon Bum;Lee, Jae Won
    • Journal of Chest Surgery
    • /
    • v.46 no.5
    • /
    • pp.353-356
    • /
    • 2013
  • A 74-year-old man was diagnosed with aortic root aneurysm and two-vessel coronary disease. Echocardiographic assessment revealed an enlarged sinus of Valsalva 60 mm in diameter with mild aortic regurgitation. Florida sleeve repair was performed using a vascular graft combined with coronary artery bypass grafting. The postoperative course was uncomplicated and follow-up echocardiographic evaluations showed an aortic root diameter of 38 mm without aortic insufficiency up to 1 year after surgery.

Aortic Valve Replacement for Aortic Stenosis in Elderly Patients (75 Years or Older)

  • Sohn, Bongyeon;Choi, Jae Woong;Hwang, Ho Young;Kim, Kyung Hwan;Kim, Ki-Bong
    • Journal of Chest Surgery
    • /
    • v.51 no.5
    • /
    • pp.322-327
    • /
    • 2018
  • Background: This study evaluated the early and long-term outcomes of surgical aortic valve replacement (AVR) in elderly patients in the era of transcatheter aortic valve implantation. Methods: Between 2001 and 2018, 94 patients aged ${\geq}75years$ underwent isolated AVR with stented bioprosthetic valves for aortic valve stenosis (AS). The main etiologies of AS were degenerative (n=63) and bicuspid (n=21). The median follow-up duration was 40.7 months (range, 0.6-174 months). Results: Operative mortality occurred in 2 patients (2.1%) and paravalvular leak occurred in 1 patient. No patients required permanent pacemaker insertion after surgery. Late death occurred in 11 patients. The overall survival rates at 5 and 10 years were 87.2% and 65.1%, respectively. The rates of freedom from valve-related events at 5 and 10 years were 94.5% and 88.6%, respectively. The Society of Thoracic Surgeons (STS) score (p=0.013) and chronic kidney disease (p=0.030) were significant factors affecting long-term survival. The minimal p-value approach demonstrated that an STS score of 3.5% was the most suitable cut-off value for predicting long-term survival. Conclusion: Surgical AVR for elderly AS patients may be feasible in terms of early mortality and postoperative complications, particularly paravalvular leak and permanent pacemaker insertion. The STS score and chronic kidney disease were associated with long-term outcomes after AVR in the elderly.

Ascending Aortic Dissection due to Trauma - A Case report - (외상에 의한 상행 대동맥 박리증의 치험 1례)

  • Seo, Pil-Won;Chae, Hurn
    • Journal of Chest Surgery
    • /
    • v.23 no.1
    • /
    • pp.174-177
    • /
    • 1990
  • Aortic dissection is a challenging disease and the causes of that are well-known. Blunt chest trauma is one of the causes of aortic dissection. In such cases, nearly all cases involves the isthmic portion of descending aorta, but ascending aorta is involved in about 10. We experienced a patient who had ascending aortic dissection due to automobile accident and who showed spontaneous rupture of the aorta during operation. In this case, after installation of aortic line via left femoral artery, ascending aorta ruptured and a large amount of blood gushed out, which was suckered by cardiotomy sucker. A little delay of cardiopulmonary bypass may cause the fatal outcome in such a case because the bleeding from aorta is too much to be controlled. Fortunately, we controlled the bleeding with cardiopulmonary bypass and got the good outcome of this patient by interpositioning the vascular graft. One should suspect the possibility of aortic dissection in blunt chest trauma, and prepare all the facilities against bleeding due to rupture.

  • PDF

Thromboexclusion Treatment for Recurrent Aortic Aneurysm: Still an Option in Select Cases

  • Choi, Jung Suk;Kim, Hwan Wook
    • Journal of Chest Surgery
    • /
    • v.52 no.6
    • /
    • pp.416-419
    • /
    • 2019
  • Flow reversal and thromboexclusion constitute a valuable alternative for aortic surgeons to have within their technical armamentarium for the treatment of aortic aneurysmal disease. Although not usually a preferred treatment for general aortic pathologies, this technique can be considered as a treatment option in select situations, such as mycotic aneurysm, a hostile surgical field, and a poor condition of the patient. Here, we present a case of extra-anatomic bypass and thromboexclusion for recurrent aortic aneurysm after previous extra-anatomic bypass and thromboexclusion surgery.