• Title/Summary/Keyword: Aortic Valve Stenosis

Search Result 147, Processing Time 0.024 seconds

Aortic Valvuloplasty in Pediatric Age (소아연령군에서의 대동맥판막성형술)

  • 임홍국;박천수;황호영;김웅한;이정렬;노준량;김용진
    • Journal of Chest Surgery
    • /
    • v.37 no.8
    • /
    • pp.652-659
    • /
    • 2004
  • Background: In this study, we retrospectively analyzed the outcomes of aortic valvuloplasty in pediatric age. Material and Method: Between January 1993 and March 2004, 35 patients underwent aortic valvuloplasty for aortic stenosis (AS) or aortic regurgitation (AR). The mean age was 81.1$\pm$61.5 (1∼223) months. The mean follow up was 50.8$\pm$30.2 (3∼121) months. Nine patients had AS, 21 had AR, and 6 had AS and AR. Valve morphology was tricuspid in 24 patients, bicuspid in 9, quadricuspid in 1, and unicuspid in 1. The mean peak pressure gradients of AS were 72.0$\pm$33.0 mmHg, and the mean grades of AR were 3.1$\pm$0.9. Result: There was one late mortality without early mortality. After operation, AS improved with mean peak pressure gradients of 23.5$\pm$21.0 mmHg (p < 0.05), and AR improved with mean grades of 1.9$\pm$0.8 (p < 0.05). At mean follow up of 35.0$\pm$23.0 months, AS maintained with mean peak pressure gradients of 31.5$\pm$24.0 mmHg, but AR progressed with mean grades of 2.8$\pm$1.3 (p < 0.05). Reoperation was required in 6 patients 38.3$\pm$21.8 months after the original operation. The actuarial figures for freedom from reoperation at 2, 5 and 8 years were 96.9$\pm$3.1%, 79.5$\pm$5.5%, and 56.8$\pm$11.4%, respectively. Age at operation, presence of AS, preoperative severity of AS or AR, and morphology of aortic valve were not significant risk factors for reoperation, and improvement of AS or AR. Conclusion: Aortic valvuloplasty showed good immediate postoperative valve function. Aortic valvuloplasty offers children many years with tolerable valve function and allows to postpone aortic valve replacement or Ross procedure in pediatric patients.

Effects of the Mitral Valve Replacement with Preservation of Posterior Mitral Leaflet and Chorda Tendinae for Mitral Valvular Disease (승모판막질환에서 승모판 대치술시 승모판 후엽 및 건삭 보존의 효과)

  • Jo, Gang-Rae;Kim, Jong-Won
    • Journal of Chest Surgery
    • /
    • v.23 no.3
    • /
    • pp.488-500
    • /
    • 1990
  • Author compared the effect of surgical methods between 40 patients who received mitral valve replacement with complete excision of the mitral valve[resected group] and 41 patients who received mitral valve replacement with preservation of posterior chorda tendineae and posterior mitral leaflet[preserved group] from 1985. 2. to 1989. 4. at cardiothoracic department of Pusan National University Hospital.v 1. There was no significant difference between the preserved group and resected group in cardiopulmonary bypass time and aortic cross clamping time and NYHA classification. 2. In preserved group of Mitral stenosis and Mitral regurgitation, the left ventricular functions were much improved after mitral valve replacement than resected group, but there was not so difference between the preserved group and reserved group in Mitral steno-regurgitation. 3. There were remarkable decrease in complication rate in preserved group compared to resected group. And also the death rates were remarkably decreased in preserved group which was 4.9% compared to resected group which was 17.5%. As the preservation of the posterior mitral leaflet and chorda tendineae during mitral valve replacement in mitral valve disease showed significantly improved effects in the maintaining of left ventricular function and reducing the postoperative complication, I assume the preservation of posterior mitral leaflet and chordae during mitral valve replacement will bring better result.

  • PDF

Mid-term Results of the Congenital Bicuspid Aortic Valve Repair (선천성 이엽성 대동맥판막질환에 대한 판막성형술의 중기 성적)

  • 조광리;곽재건;안혁
    • Journal of Chest Surgery
    • /
    • v.37 no.10
    • /
    • pp.833-838
    • /
    • 2004
  • Background: Despite the excellent early results after the repair of congenital bicuspid aortic valve (BAV) disease, the mid-term durability of the repaired valve has still controversies. Material and Method: To evaluate the mid-term results of BAV repair, retrospective review of medical records and echocardiographic data were done. Between 1994 and 2003, twenty-two patients underwent reparative procedure for either regurgitant or stenotic congenital bicuspid aortic valve (BAV). Result: Mean age was $41\pm14$ years with male predominance (Male=17, Female=5). The pathophysiologies of the BAV were regurgitation-dominant in 20 (91%) and stenosis-dominant in 2 (9%) cases. Various repair techniques were used for raphe, prolapsed leaflet, thickened leaflet, and commissures; 1) release of raphe in 19 (86%), 2) wedge resection and primary repair in 11 (50%), pericardial patch reinforcement after plication of the leaflet in 6 (27%), and plication of the leaflet in 3 (14%), 3) slicing of thickened leaflet was used in 12 (55%) cases, 4) commissuroplasty in 8 (36%), and commissurotomy in 6 (27%) cases. There was no in-hospital mortality. During the mean follow-up of $38\pm17$ months, one patient underwent aortic valve replacement after developing acute severe regurgitation from dehiscence of the suture on postoperative 2 months. New York Heart Association functional class was improved from $1.9\pm0.6$ to $1.2\pm0.5$ (p<0.01). Left ventricular end-systolic and diastolic dimension (LVESD/LVEDD) were also improved from $45\pm9$ and $67\pm10$ to $37\pm10$ and $56\pm10,$ respectively (p<0.01). The grade of aortic regurgitation (AR) was improved from preoperative $(3.1\pm1.2)$ to post-bypass $(0.9\pm0.7).$ However, the grade at last follow-up $(1.7\pm1.1)$ was deteriorated during the follow-up period (p<0.01). Freedom from grade III and more AR at one, three, and four year were 89.7%, 89.7%, and 39.9% respectively. Conclusion: Midterm clinical result of the BAV repair was favorable. But, the durability of the repaired valve was not satisfactory.

Clinical Application of Balloon Valvuloplasty in a Boxer Dog with Subaortic Stenosis (대동맥 판막하 협착증에 이환된 박서견의 풍선 확장술 적용예)

  • Choi, Ran;Nam, So-Jeong;Hyun, Chang-Baig
    • Journal of Veterinary Clinics
    • /
    • v.26 no.2
    • /
    • pp.160-165
    • /
    • 2009
  • A 4-month-old intact male Boxer dog(9 kg of body weight) was presented with the primary complaints of heart murmur and exercise intolerance. Diagnostic studies revealed severe subaortic stenosis. Since the pressure gradient(PG) in stenotic aortic valve area was higher than ${\sim}120mmHg$(5.4 m/s of peak velocity), the dog was underwent balloon valvuloplasty. With this procedure, the peak aortic velocity was reduced to 3.9 m/s(${\sim}60mmHg$ of PG) and the clinical condition of dog was markedly improved. Periodic re-evaluations performed at monthly interval revealed no further deterioration. This is the first case report of subaortic stenosis treated by non-surgical palliative balloon valvuloplasty in Korea.

Diagnostic Efficacy and Safety of Low-Contrast-Dose Dual-Energy CT in Patients With Renal Impairment Undergoing Transcatheter Aortic Valve Replacement

  • Suyon Chang;Jung Im Jung;Kyongmin Sarah Beck;Kiyuk Chang;Yaeni Kim;Kyunghwa Han
    • Korean Journal of Radiology
    • /
    • v.25 no.7
    • /
    • pp.634-643
    • /
    • 2024
  • Objective: This study aimed to evaluate the diagnostic efficacy and safety of low-contrast-dose, dual-source dual-energy CT before transcatheter aortic valve replacement (TAVR) in patients with compromised renal function. Materials and Methods: A total of 54 consecutive patients (female:male, 26:38; 81.9 ± 7.3 years) with reduced renal function underwent pre-TAVR dual-energy CT with a 30-mL contrast agent between June 2022 and March 2023. Monochromatic (40- and 50-keV) and conventional (120-kVp) images were reconstructed and analyzed. The subjective quality score, vascular attenuation, contrast-to-noise ratio (CNR), and signal-to-noise ratio (SNR) were compared among the imaging techniques using the Friedman test and post-hoc analysis. Interobserver reliability for aortic annular measurement was assessed using the intraclass correlation coefficient (ICC) and Bland-Altman analysis. The procedural outcomes and incidence of post-contrast acute kidney injury (AKI) were assessed. Results: Monochromatic images achieved diagnostic quality in all patients. The 50-keV images achieved superior vascular attenuation and CNR (P < 0.001 in all) while maintaining a similar SNR compared to conventional CT. For aortic annular measurement, the 50-keV images showed higher interobserver reliability compared to conventional CT: ICC, 0.98 vs. 0.90 for area and 0.97 vs. 0.95 for perimeter; 95% limits of agreement width, 0.63 cm2 vs. 0.92 cm2 for area and 5.78 mm vs. 8.50 mm for perimeter. The size of the implanted device matched CT-measured values in all patients, achieving a procedural success rate of 92.6%. No patient experienced a serum creatinine increase of ≥ 1.5 times baseline in the 48-72 hours following CT. However, one patient had a procedural delay due to gradual renal function deterioration. Conclusion: Low-contrast-dose imaging with 50-keV reconstruction enables precise pre-TAVR evaluation with improved image quality and minimal risk of post-contrast AKI. This approach may be an effective and safe option for pre-TAVR evaluation in patients with compromised renal function.

Left Ventricular Assist Device Implantation via Dual Left Thoracotomy in an Adult Patient with Congenitally Corrected Transposition of the Great Arteries

  • Kim, Shin;Cho, Yang-Hyun;Park, Pyo Won;Lee, Young Tak;Jun, Tae-Gook;Kim, Wook Sung;Sung, Kiick;Yang, Ji-Hyuk;Chung, Suryeun
    • Journal of Chest Surgery
    • /
    • v.53 no.5
    • /
    • pp.306-309
    • /
    • 2020
  • A 59-year-old man presented for possible durable ventricular assist device (VAD) implantation. He had previously been diagnosed with congenitally corrected transposition of the great arteries, a ventricular septal defect, an atrial septal defect, pulmonary valve stenosis, and aortic valve regurgitation. In the previous 22 years, he had undergone palliative cardiac surgery 3 times. VAD implantation as a bridge to transplantation was planned. Owing to severe adhesions, mesocardia, a left ascending aorta, and moderate aortic regurgitation, we performed VAD implantation and aortic valve closure via a dual left thoracotomy and partial sternotomy.

Influence of Prosthesis Size on Change in Left Ventricular Hypertrophy Following Aortic Valve Replacement (대동맥판막협착증 환자에서 판막치환 후 좌심실 심근비후의 변화에 대한 판막크기의 영향)

  • 이희성;지현근;김건일;홍기우;신윤철
    • Journal of Chest Surgery
    • /
    • v.34 no.1
    • /
    • pp.57-63
    • /
    • 2001
  • 배경: 대동맥판막협착증 환자는 판막질환으로 인한 만성적인 후부하의 증가에 대한 보상성 좌심실 심근비후가 일어나게 된다. 대동맥 판막 치환 후 좌심실 심근 비후의 감소가 이루어지는 것으로 알려져 있으나 21mm이하의 작은 인공판막으로 치환시 좌심실 심근 변화에 대해 논란이 있다. 대상 및 방법: 1994년 9월부터 1998년 7월까지 한림대학교 강동성심병원 흉부외과에서 대동맥판막협착증으로 진단받고 판막치환술을 시행한 20명을 대상으로 하였다. 환자는 남녀 각각 13명, 7명이며 평균나이 61$\pm$13.8세 체표면적은 평균 1.57$\pm$0.14m$m^2$이었다. 환자의 추적관찰은 수술 전, 수술 후 초기(평균 10.4일) 및 수술 후 만기(평균 29.9개월)에 심초음파로 시행하였다. 환자들은 사용된 판막에 따라 2개의 군(1군;21mm 이하, 2군;23mm이상)으로 나누었다. 결과: 모든 군에서 NYHA Functional class의 유의한 감소가 있었다. 좌심실 구추률은 수술 전후 1군은 유의한 차이가 없었으나 2군에서는 유의한 차이가 있었다. 그러나 수술 전 좌심실 구출률이 2군에서 1군에 비해 유의하게 감소되어 있었다(p=0.044). 좌심실근량지수는 1군은 수술후 초기에 유의한 감소가 없었으나 수술후 만기에는 유의한 감소를 보여주었다. 그러나 2군은 수술후 초기와 만기에 모두 유의한 감소를 보여주었다. 결론: 21 mm이하 군과 23 mm이상 군 모두 임상적 호전이 있었다. 그러나 19 mm판막군이 2례로 적어 19 mm 판막의 사용시 환자의 나이와 체표면적, 운동량을 고려하여 신중한 판막선택이 고려된다.

  • PDF

Factors influencing the prognosis after total correction of tetralogy of Fallot (Fallot 4징증의 근치수술후 예후에 영향을 미치는 요소)

  • Min, Yong-Il;O, Bong-Seok;Lee, Dong-Jun
    • Journal of Chest Surgery
    • /
    • v.20 no.1
    • /
    • pp.71-80
    • /
    • 1987
  • Twenty six patients were operated a total correction of tetralogy of Fallot between Jan., 1984 and July, 1985 at the Dept. of thoracic and cardiovascular surgery, Chonnam University Medical School, and a comparison between the survived group [n = 18] and the dead group [n = B was performed to detect factors influencing laboratory data, cineangiographic findings, operative findings and methods, and pump time. Following results were obtained, 1. There was no significant difference between two groups in the preoperative P.O2 and hematocrit level. 2. The size of the interventricular defect was not related to the operative mortality. 3. There was a significant difference in mortality rate between combined type of stenosis of pulmonary artery, valve and infundibulum and other types of right ventricular outflow tract stenosis. 4. There was a significant difference in mortality rate between the transannular patch reconstruction and other types of operative procedure. 5. There was no significant difference between two groups in total bypass time and aortic time. 6. There was no significant difference between two groups in left ventricular end diastolic volume and right ventricular end diastolic volume. 7. The operative mortality was related to the ratio of the diameter of the pulmonary valve annulus or each pulmonary artery to the ascending or descending aorta in cineangiographic findings, but there was no statistical significance of which probably is due to the lack of the total number of patients.

  • PDF

Reduction Aortoplasty with Suture Plication Technique for Dilatation of the Ascending Aorta associated with Aortic Valve Disease (대동맥판막 질환과 동반된 상행대동맥 확장에 대한 봉합봉축법에 의한 대동맥 축소성형술)

  • Na Chan-Young;Oh Sam-Sae;Lee Chang-Ha;Whang Seong Wook;Lee Cheol;Lim Hong Gook;Kim Jae Hyun;Seo Hong Ju;Kim Gun Gyk;Baek Man-Jong
    • Journal of Chest Surgery
    • /
    • v.38 no.3 s.248
    • /
    • pp.221-228
    • /
    • 2005
  • Reduction aortoplasty has been advocated for dilatation of the ascending aorta associated with aortic valve disease in older, high-risk patients. We report our results with modification of reduction aortoplasty and aortic valve replacement. Material and Method: Between July 2001 and December 2002, 14 consecutive patients who underwent modification of reduction aortoplasty, suture plication technique without excision of the dilated aortic wall, were reviewed. The mean age was 63.7$\pm$6.7 (50 to 75) years. Ten patients had congenital bicuspid aortic valve, Twelve patients had severe aortic valve stenosis and 6 had regurgitation of grade III$\~$IV. The diameter of the ascending aorta was measured before and immediately after surgery and 6 and 12 months postoperatively using echocardiography or computed tomography. Follow-up was complete in an average of 14.7$\~$5.4 (7 to 24) months. Result: There were no early postoperative deaths and no bleeding complications. Reduction aortoplasty with suture plication technique decreased the diameter of ascending aorta from 49.4$\pm$3.5 mm preoperatively to 33.2$\pm$3.4 mm postoperatively (p <0.001). During follow-up, there were no late deaths and no aneurysm recurrence on the ascending aorta. Conclusion: Suture plication technique of reduction aortoplasty without excision of the dilated aortic wall offers good early and short-term results in older, high-risk patients with dilatation of the ascending aorta associated with aortic valve disease. Surgical long-term results of our technique should be evaluated in further studies.

Comparison of Intracardiac Echocardiography Versus Transesophageal Echocardiography for Guidance During Transcatheter Aortic Valve Replacement

  • Sang-Hyup Lee;Seunguk Oh;Young-Guk Ko;Yong-Joon Lee;Seung-Jun Lee;Sung-Jin Hong;Chul-Min Ahn;Jung-Sun Kim;Byeong-Keuk Kim;Kyu-Yong Ko;Iksung Cho;Chi Young Shim;Geu-Ru Hong;Donghoon Choi;Myeong-Ki Hong
    • Korean Circulation Journal
    • /
    • v.54 no.2
    • /
    • pp.63-75
    • /
    • 2024
  • Background and Objectives: Evidence regarding the efficacy and safety of intracardiac echocardiography (ICE) for guidance during transcatheter aortic valve replacement (TAVR) is limited. This study aimed to compare the clinical efficacy and safety of ICE versus transesophageal echocardiography (TEE) for guiding TAVR. Methods: This prospective cohort study included patients who underwent TAVR from August 18, 2015, to June 31, 2021. Eligible patients were stratified by echocardiographic modality (ICE or TEE) and anesthesia mode (monitored anesthesia care [MAC] or general anesthesia [GA]). Primary outcome was the 1-year composite of all-cause mortality, rehospitalization for cardiovascular cause, or stroke, according to the Valve Academic Research Consortium-3 (VARC-3) definition. Propensity score matching was performed, and study outcomes were analyzed for the matched cohorts. Results: Of the 359 eligible patients, 120 patients were matched for the ICE-MAC and TEEGA groups, respectively. The incidence of primary outcome was similar between matched groups (18.3% vs. 20.0%; adjusted hazard ratio, 0.94; 95% confidence interval [CI], 0.53-1.68; p=0.843). ICE-MAC and TEE-GA also had similar incidences of moderate-to-severe paravalvular regurgitation (PVR) (4.2% vs. 5.0%; adjusted odds ratio, 0.83; 95% CI, 0.23-2.82; p=0.758), new permanent pacemaker implantation, and VARC-3 types 2-4 bleeding. Conclusions: ICE was comparable to TEE for guidance during TAVR for the composite clinical efficacy outcome, with similar incidences of moderate-to-severe PVR, new permanent pacemaker implantation, and major bleeding. These results suggest that ICE could be a safe and effective alternative echocardiographic modality to TEE for guiding TAVR.