• 제목/요약/키워드: AoA

검색결과 491건 처리시간 0.03초

Analysis of Tip/Tilt Compensation of Beam Wandering for Space Laser Communication

  • Seok-Min Song;Hyung-Chul Lim;Mansoo Choi;Yu Yi
    • Journal of Astronomy and Space Sciences
    • /
    • 제40권4호
    • /
    • pp.237-245
    • /
    • 2023
  • Laser communication has been considered as a novel method for earth observation satellites with generation of high data volume. It offers faster data transmission speeds compared to conventional radio frequency (RF) communication due to the short wavelength and narrow beam divergence. However, laser beams are refracted due to atmospheric turbulence between the ground and the satellite. Refracted laser beams, upon reaching the receiver, result in angle-of-arrival (AoA) fluctuation, inducing image dancing and wavefront distortion. These phenomena hinder signal acquisition and lead to signal loss in the course of laser communication. So, precise alignment between the transmitter and receiver is essential to guarantee effective and reliable laser communication, which is achieved by pointing, acquisition, and tracking (PAT) system. In this study, we simulate the effectiveness of tip/tilt compensation for more efficient laser communication in the satellite-ground downlink. By compensating for low-order terms using tip/tilt mirror, we verify the alleviation of AoA fluctuations under both weak and strong atmospheric turbulence conditions. And the performance of tip/tilt correction is analyzed in terms of the AoA fluctuation and collected power on the detector.

Robust feedback-linearization control for axial power distribution in pressurized water reactors during load-following operation

  • Zaidabadi nejad, M.;Ansarifar, G.R.
    • Nuclear Engineering and Technology
    • /
    • 제50권1호
    • /
    • pp.97-106
    • /
    • 2018
  • Improved load-following capability is one of the most important technical tasks of a pressurized water reactor. Controlling the nuclear reactor core during load-following operation leads to some difficulties. These difficulties mainly arise from nuclear reactor core limitations in local power peaking: the core is subjected to sharp and large variation of local power density during transients. Axial offset (AO) is the parameter usually used to represent the core power peaking. One of the important local power peaking components in nuclear reactors is axial power peaking, which continuously changes. The main challenge of nuclear reactor control during load-following operation is to maintain the AO within acceptable limits, at a certain reference target value. This article proposes a new robust approach to AO control of pressurized water reactors during load-following operation. This method uses robust feedback-linearization control based on the multipoint kinetics reactor model (neutronic and thermal-hydraulic). In this model, the reactor core is divided into four nodes along the reactor axis. Simulation results show that this method improves the reactor load-following capability in the presence of parameter uncertainty and disturbances and can use optimum control rod groups to maneuver with variable overlapping.

Hypocholesterolemic Effect of Amaranth Squalene (Amaranth esculantus) in Rats Fed a High Cholesterol Diet

  • Kim, Hye-Kyung;Chang, Young-Jeong;Heo, Ho-Jin;Cho, Hong-Yon;Hong, Bum-Shik ;Shin, Dong-Hoon
    • Preventive Nutrition and Food Science
    • /
    • 제8권1호
    • /
    • pp.13-18
    • /
    • 2003
  • In experiment 1, rats (n=6) fed diet containing 10 g/kg cholesterol for 4 wk (control) with either no amaranth (control), amaranth grain (300 g/kg, AG) or amaranth oil (90 g/kg, AO). Both the AG and AO groups had lower concentration of serum and hepatic cholesterol and triglyceride than the controls (p < 0.05). Fecal excretions of cholesterol and bile acid in AO group increased about 4 fold and 2 fold, respectively, while AG affected only bile acid excretion (p < 0.05). In experiment 2, rats (n=6) were fed the cholesterol diet for 4 wk and injected intraperitoneally with saline (control) or amaranth squalene (AS) for 7d. The hypolipidemic effect of AS was evident in both serum and liver. Fecal excretions of cholesterol and bile acid were greater (p < 0.05) in AS than control. HMG-CoA (3-hydroxy-3-methylglutaryl coenzyme A) reductase activity was reduced in AS group (11.6%, p=0.13). This study suggests that the cholesterol-lowering effect of AS is mediated by greater fecal elimination of steroids through interference with cholesterol absorption.

고받음각에서 조종성능 및 안정성 증강을 위한 제어법칙에 관한 연구 (A Study on Control Law Augmentation in order to Improve Aircraft Controllability and Stability in High Angle of Attack)

  • 김종섭;황병문;이동규
    • 한국항공우주학회지
    • /
    • 제33권10호
    • /
    • pp.60-67
    • /
    • 2005
  • 현대의 고성능 전투기는 한계받음각 내에서 적절한 조종성(Controllability) 및 안정성(Stability)을 확보하고 있어야 한다. 고받음각에서 항공기가 이탈에 진입할 수 있는 한계값은 항공기 형상설계에 직결되는 문제이다. 하지만 현대의 고성능 전투기는 전기식 비행제어계통(Digital Fly-By-Wire Flight Control System)을 사용하여 고받음각 제어법칙을 설계함으로써 한계값 내에서 항공기의 안정성을 보장하고 있다. 현재, T-50 세로축 고받음각 제어법칙에는 (+)한계받음각 이상으로의 비행을 제한하는 받음각 제한기(Angle of Attack Limiter)가 설계되어 있다. 그러나 (-)한계받음각 이상으로 비행을 제한하는 받음각 제한기는 설계되어 있지 않아, 조종사의 과도한 (-)세로축 기동에 대해 항공기가 이탈에 진입할 수 있다. 그리고 T-50 비행시험에서 PA에서 과도한 (+)세로축 기동 시, 받음각(Angle of Attack)이 현재 설계되어 있는 한계받음각을 초과하는 문제점이 발생하였다. 본 논문에서는 고받음각 제어법칙을 일부 수정하여 한계받음각 내에서 항공기의 세로축 조종성능을 향상시키고, 항공기 안정성을 확보할 수 있는 제어법칙에 관한 연구를 수행하였다.

Texture analysis in cone-beam computed tomographic images of medication-related osteonecrosis of the jaw

  • Polyane Mazucatto Queiroz;Karolina Castilho Fardim;Andre Luiz Ferreira Costa;Ricardo Alves Matheus;Sergio Lucio Pereira Castro Lopes
    • Imaging Science in Dentistry
    • /
    • 제53권2호
    • /
    • pp.109-115
    • /
    • 2023
  • Purpose: The aim of this study was to evaluate changes in the trabecular bone through texture analysis and compare the texture analysis characteristics of different areas in patients with medication-related osteonecrosis of the jaw (MRONJ). Materials and Methods: Cone-beam computed tomographic images of 16 patients diagnosed with MRONJ were used. In sagittal images, 3 regions were chosen: active osteonecrosis(AO); intermediate tissue (IT), which presented a zone of apparently healthy tissue adjacent to the AO area; and healthy bone tissue (HT) (control area). Texture analysis was performed evaluating 7 parameters: secondary angular momentum, contrast, correlation, sum of squares, inverse moment of difference, sum of entropies, and entropy. Data were analyzed using the Kruskal-Wallis test with a significance level of 5%. Results: Comparing the areas of AO, IT, and HT, significant differences (P<0.05) were observed. The IT and AO area images showed higher values for parameters such as contrast, entropy, and secondary angular momentum than the HT area, indicating greater disorder in these tissues. Conclusion: Through texture analysis, changes in the bone pattern could be observed in areas of osteonecrosis. The texture analysis demonstrated that areas visually identified and classified as IT still had necrotic tissue, thereby increasing the accuracy of delimiting the real extension of MRONJ.

Implementation of Audio Effect Device for Anchor System

  • Seungwon Lee;Soonchul Kwon;Seunghyun Lee
    • International journal of advanced smart convergence
    • /
    • 제13권3호
    • /
    • pp.1-12
    • /
    • 2024
  • Recently, Audio systems transform the configuration of conventional sound reinforcement and public address systems using audio over internet protocol (AoIP), whereby audio signals are transmitted and received based on internet protocol (IP). Currently, AoIP technologies are leading the audio market, and various technologies have been released. Audio networks and the control hierarchy over peer-to-peer (Anchor) technology based on AoIP transmit and receive audio signals over a wide bandwidth without an audio mixer. Audio system based on Anchor technology is constructed by connecting the on-site audio center (OAC), a device that can transmit and receive audio sources and output equipment over IP. Receiving OAC of the Anchor technology can receive and mix audio signals transmitted from different IPs; consequently, novel audio systems can be configured by replacing conventional audio mixers. However, the Anchor technology does not have an equalizer function for improving the quality of audio equipment. Therefore, tone distortion may occur owing to signal loss between equipment, poor audio-signal clarity, and howling due to audio deformation according to different architectural structures and environments. In this study, we implemented an audio effect device capable of tone control using the Audio Processor Core. Using Anchor technology, tone control was realized through an audio effect device in the receiving OAC. The output of the incoming OAC was received by the audio effect device, which adjusted the tone and then outputted it. Thus, the tone issues in Anchor technology were overcome by the receiving OAC and audio effect devices. In future, audio system configurations using Anchor technology could be the standard for audio equipment.

저온플라즈마와 촉매를 이용한 톨루엔 분해 연구 (Study of toluene decomposition using nonthermal plasma and catalyst)

  • 임윤희;이주열;신재란;최진식;박병현
    • 한국응용과학기술학회지
    • /
    • 제31권4호
    • /
    • pp.541-548
    • /
    • 2014
  • This study was performed to obtain high conversion efficiency of $C_7H_8$ using non-thermal plasma and metal-supported catalyst. Adsorption-desorption characteristics of toluene was performed using 4A type (Zeolite) filled in a concentration reactor. Through this test, it was found that the concentration reactor has 0.020 g/g of adsorption capacity (at ambient temperature and pressure) and 3,600 ppm of desorption property at $150^{\circ}C$ (with in 20 min). In case of developed catalyst, toluene decomposition rate of Pd-AO (Pd coated catalyst) was better than Pd/Cu-AO and Pd/Ag-AO (Pd/Ag composite metal catalyst). Developed non-thermal plasma system was obtained flame amplification effect using injection process of desorbed tolune, and 98% of removal efficiency.

Association between obesity and high-sensitivity C-reactive protein in Korean adults without cardiovascular disease

  • Heashoon, Lee
    • Journal of Korean Biological Nursing Science
    • /
    • 제25권1호
    • /
    • pp.32-42
    • /
    • 2023
  • Purpose: This study aimed to investigate the association between obesity and high-sensitivity C-reactive protein (hs-CRP) levels in Korean adults without cardiovascular disease (CVD). Methods: The subjects were 3,634 adults, and data were extracted from the seventh Korea National Health and Nutrition Examination Survey (KNHANES VII-3). A complex sampling design analysis was applied to reflect the stratified and clustered weights. The data were analyzed using the complex sample Rao-Scott chi-square test and multiple logistic regression analysis (in SPSS for Windows version 26.0). Obesity, according to body mass index (BMI), was defined as obesity (BMI = 25-29.9 kg/m2), high obesity (BMI = 30-34.9 kg/m2), and super-high obesity (BMI ≥ 35 kg/m2), and abdominal obesity (AO) was defined as a waist circumference (WC) ≥ 90 cm in males and WC ≥ 85 cm in females. Results: The odds ratios for moderate CVD risk (hs-CRP; 1-3 mg/dL) were 2.21, 4.16, and 7.13 in the obesity, high obesity, and super-high obesity groups, respectively, compared to the normal BMI group. The odds ratio for moderate CVD risk was 2.18 in males with AO and 1.88 in females with AO. The odds ratios for high CVD risk (hs-CRP > 3 mg/L) were 4.40 and 17.55 in the high obesity and super-high obesity groups, respectively, compared to the normal BMI group. Conclusion: This study provides evidence that early detection and prevention programs for CVD should include obesity-related interventions aiming to modulate hs-CRP.

AO C-형 원위 대퇴골 골절의 치료로 삽입된 관외측 금속판의 절경 보조하 최소 침습적 제거의 결과 (Results of Arthroscopic-assisted Minimally Invasive Removal of a Lateral Periarticular Plate used for the Treatment of AO Type-C Distal Femoral Fractures)

  • 김영모;이준규;양재훈;김보건;이원구
    • 대한관절경학회지
    • /
    • 제13권1호
    • /
    • pp.46-52
    • /
    • 2009
  • 목적: AO C-형 원위 대퇴골 골절의 치료로서 대퇴골 외측에 금속판을 삽입한 후, 관절경 보조하 최소 침습적 금속판 제거를 시행하였던 환자들을 대상으로 술식의 유용성을 조사하였다. 대상 및 방법: 2002년 10월부터 2005년 11월까지 AO C-형 원위 대퇴골 골절로 관혈적 정복 및 대퇴골 외측면에 금속판 내고정술을 시행하였던 환자들 중 대퇴골 외과 부위의 불편감으로 인해 관절경 보조하 최소 침습적 금속판 제거를 시행하였던 17예와 관절경 없이 고식적인 방법으로 금속판 제거슬 시행한 15예, 총 32예를 대상으로 하였다. 평균 연령은 42.6세(20~66세), 최초 골절 상태는 AO/ASIF 분류상 C1 16예, C2 11예, C3 5예였다. 술 중 확인된 관절내 병변, 술 후 합병증 및 술 후 일상 생활로의 복귀 시간, 수술에 대한 만족도, 술 전 및 술 후 6개월 추시상의 슬관절 통증을 조사하였다. 결과: 전 예에서 금속판의 최고 원위부는 슬관절 내에 위치하였고, 23예에서 이와 접촉하는 외측 관절낭의 손상이 확인되었다. 관절경 보조하 금속판 제거술을 시행한 군에서 금속판 제거술 후 지속적 창상 배액으로 세척술 및 창상 재 봉합술을 시행한 경우가 1예 있었다. 술 후 일상 생활로의 복귀는 관절경 보조하 금속판 제거술을 시행한 군에서 평균 7일이었고, 고식적 금속판 제거술을 시행한 군에서 평균 7.6일 이었다. 관절경 보조하 금속판 제거술을 시행한 군은 14예(82.4%)에서 '보통' 이상의 수술 만족도를 보였으며, VAS 통증 지수는 수술 전 4.9에서 수술 후 6개월에 1.9로 감소하였다. 고식적 금속판 제거술을 시행한 군은 13예(86.7%)에서 보통' 이상의 수술 만족도를 보였으며, VAS 통증 지수는 수술전 5.2에서 수술 후 6개월에 2.5로 감소하였다. 결론: 본 술식은 원위 대퇴골에 삽입된 금속판 제거와 함께 슬관절 내의 다양한 병변의 확인 및 치료가 가능한 장점이 있었다. C-형 원위 대퇴골 골절의 치료를 위해 삽입된 금속판에 의한 슬관절 외측 관절낭의 손상이 매우 빈번히 확인되었고, 금속판을 제거함으로서 슬관절 통증이 감소하는 것을 확인하였음으로, C-형 원위 대퇴골 골절과 같이 금속판의 최고 원위부가 관절내에 위치하는 경우에는 골절의 유합이 이루어지면 금속판을 제거되어야 할 것으로 사료된다.

  • PDF

Treatment of Acute Acromioclavicular Joint Injuries Using AO Hook Locking Plate

  • Kim, Kyung Cheon;Jeon, Yoo Sun
    • Clinics in Shoulder and Elbow
    • /
    • 제17권3호
    • /
    • pp.114-119
    • /
    • 2014
  • Background: To evaluate clinical and radiological outcome using AO hook locking plate in acute acromioclavicular joint injuries. Methods: This study was based on patients with Rockwood type 3 or 5 acromioclavicular joint injuries who received surgery with AO hook locking plate from June 2008 until June 2009. Among the 22 patients, 19 of them were male and 3 were female, the mean age was $44.4{\pm}15.57$ years (20-72 years) and follow-up period was $15.5{\pm}3.90$ months (12-23 months). Preoperatively, postoperatively, and at the final follow-up after the plate removal, both coracoclavicular distances were measured from the anteroposterior radiograph. Also, the Shoulder Rating Scale of the University of California at Los Angeles scores (UCLA scores), the American Shoulder and Elbow Surgeons scores (ASES scores), Constant scores, and the Korean Shoulder Society scores (KSS scores) were measured at the final followup to evaluate the function of the shoulder joint. Results: At the time of injury, the mean coracoclavicular distance of the injured side was $17.69{\pm}4.23mm$ (9.57-27.82 mm) and the unaffected side was $7.55{\pm}2.20mm$ (3.24-13.05 mm). The mean coracoclavicular distance measured postoperatively and at the final follow-up was $6.87{\pm}2.34mm$ (4.07-14.13 mm) and $8.47{\pm}2.96mm$ (4.37-17.48 mm), respectively. The mean UCLA, ASES, Constant, and KSS scores measured in the final follow-up were $33.5{\pm}1.30$ (31-35), $90.8{\pm}8.36$ (72-100), $78.6{\pm}8.80$ (62-100), and $94.4{\pm}5.08$ (84-100) each. Conclusions: From this short-term research, the surgical treatment using AO hook locking plates in acute acromioclavicular joint injuries is clinically and radiographically satisfying and considered as a useful treatment method.