• Title/Summary/Keyword: Antibody screening

Search Result 155, Processing Time 0.021 seconds

Live Cell Detection of Monoclonal Antibody Light and Heavy Chain mRNAs using Molecular Beacons (분자 비컨을 이용한 살아 있는 세포에서 단일클론항체 경쇄와 중쇄 mRNA 검출에 의한 세포주 선별방법)

  • Jeong, Seunga;Rhee, Won Jong
    • KSBB Journal
    • /
    • v.31 no.1
    • /
    • pp.33-39
    • /
    • 2016
  • Developing the method for the selection of animal cell line producing therapeutic monoclonal antibody (mAb) is invaluable as its market is rapidly growing. Although the quality of produced mAb is as important as quantity, however there is no method developed for the selective screening of cell lines on the basis of both quantity and quality. From recent reports, the ratio of light and heavy chain mRNAs of mAb in the cell is a key parameter for the indication of product quality. Therefore, it is obvious that developing the novel method that can detect both light and heavy chain mRNAs in single live cell will provide unprecedented opportunities in bio-industry. Here, we have constructed oligonucleotide probes, molecular beacons for the detection of light or heavy chain mRNAs, respectively, in the live cells producing mAbs. Both beacons showed increased fluorescent intensity after transient transfection of plasmid expressing mAbs analyzed by fluorometer. Flow cytometric analysis clearly demonstrated that both molecular beacons can simultaneously detect the expression of light and heavy chain mRNAs of mAb in the same cell. The technique described in the thesis provides the new direction and concept for developing the method for the smart selection of cell lines producing recombinant proteins including therapeutic mAbs.

High-Efficiency Generation of Monoclonal Antibody for Vitreoscilla Hemoglobin Protein

  • Kim, Eun-Mi;Kim, Myung-Hee;Kim, Min-Gon;Kim, Sang-Woo;Ro, Hyeon-Su
    • Journal of Microbiology and Biotechnology
    • /
    • v.22 no.2
    • /
    • pp.226-229
    • /
    • 2012
  • Bacterial hemoglobin from Vitreoscilla (VHb) is recognized as a good fusion protein for the soluble expression of foreign protein. In this study, we generated a monoclonal antibody (MAb) against VHb for its detection. For the rapid screening of MAb, a protein chip technology based on the Alexa-488 (A488) dye labeling method was introduced. In order to fabricate the chip, the VHb protein was chemically coupled to the chip surface and then the culture supernatants of 84 hybridoma cell lines were spotted onto the VHb chip. The bound MAbs were measured by A488-modified anti-mouse IgG. A single spot (MAb A10) exhibited significantly high signal intensity. The immunoblot analysis evidenced that the MAb A10 can detect VHb-fused proteins with high specificity.

Fabrication of Biochip Using Gray-scale Photolithography (Gray-scale photolithography를 이용한 바이오칩 제작)

  • Bae, Young-Min
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.1
    • /
    • pp.137-141
    • /
    • 2008
  • Biochip, which implements bioanalytical process on a tiny surface, is one of candidates for medical diagnosis, drug screening, and molecular sensing. In general, a type of biochip based on microfluidics is composed of microcomponents including microchannel, pump, and valve, which require complicated processes. In this study, gray-scale photolithography(GSPL) was applied to fabricate a biochip with multiple layers. A mould for casting PDMS(polydimethylsiloxane) channel, was fabricated using GSPL. A gray-photomask was prepared by printing gray patterns on a high-quality glossy paper followed by photoreducing by 10:1 onto the photo-film. The formation of multiple layers was studied according to the change of gray level of pattern and the developing time. A biochip composed of a weir(multiple layer structure) and a reaction chamber in a single microchannel was fabricated in a glass plate. Finally, we investigated the application of biochip to antigen-antibody reaction by packing the microbead coated with antibody.

A Generic Time-resolved Fluorescence Assay for Serine/threonine Kinase Activity: Application to Cdc7/Dbf4

  • Xu, Kui;Stern, Alvin S.;Levin, Wayne;Chua, Anne;Vassilev, Lyubomir T.
    • BMB Reports
    • /
    • v.36 no.4
    • /
    • pp.421-425
    • /
    • 2003
  • The serine/threonine protein kinase family is a large and diverse group of enzymes that are involved in the regulation of multiple cellular pathways. Elevated kinase activity has been implicated in many diseases and frequently targeted for the development of pharmacological inhibitors. Therefore, non-radioactive antibody-based kinase assays that allow high throughput screening of compound libraries have been developed. However, they require a generation of antibodies against the phosphorylated form of a specific substrate. We report here a time-resolved fluorescence assay platform that utilizes a commercially-available generic anti-phosphothreonine antibody and permits assaying kinases that are able to phosporylate threonin residues on protein substrates. Using this approach, we developed an assay for Cdc7/Dbf4 kinase activity, determined the $K_m$ for ATP, and identified rottlerin as a non-ATP competitive inhibitor of this enzyme.

Investigation of Domestic and Foreign Unexpected Antibodies for Emergency Blood Transfusion (응급수혈을 위한 비예기 항체의 국내·외 실태조사)

  • Weonjoo, Hwang;Sang-Hee, Lee;Chang-Eun, Park
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.54 no.4
    • /
    • pp.279-284
    • /
    • 2022
  • Certain pre-transfusion tests are not commonly performed during emergency blood transfusion. In this study, we reviewed and analyzed the data of post-blood transfusion antibody screening tests to establish the effects of unexpected antibodies causing hemolytic transfusion reactions. We reviewed information published domestically and internationally, and selected the data of 68,602 antibody screening tests and 528 antibody identification tests conducted at P hospital. We found that unexpected antibody positive (1198,1.74%), Rh type (161, 30.49%), Lewis type (67, 12.69%), others (Di (a), 28, 5.30%). The anti-E type positive was 93 (17.61%), and that of the cases with anti-C (13, 2.46%). Only data of domestic cases were included for analysis that were published before 2007, which established the presence of antibodies of the following types and numbers of cases: anti-E (196, 22.45%), anti-Le a (82, 9.39%), and anti-E+C (60, 6.87%). In 2018, anti-E (107, 17.12%), anti-E+Canti-E+C (56, 8.96%), and anti-Di a (28, 4.48%) were detected. In other domestic cases, S hospital was detect to anti-E, anti-Le a, anti-E+C. The Anti-E, anti-D, anti-E+C, and anti-C+E were detected in D hospital. In Saudi Arabia, Anti-D, anti-E, and anti-Jka was detected. The Anti-M, Anti-N, Anti-Le (a), and Anti-D were detected in India. Requests for emergency blood transfusion increased 1.8 times after the opening of the trauma center. This study has the disadvantage of being a cross-sectional study. additional studies are needed to provide basic information on alternative treatments that can increase the safety and reduce the side effects of hemolytic transfusion in emergency transfusion situations.

Serodiagnosis of canine toxoplasmosis by latex agglutination and indirect fluorescent antibody test (Latex 응집반응과 간접형광항체법을 이용한 개 톡소플라즈마병의 혈청학적 진단)

  • Lee, Byung-hoon;Lee, Eung-goo;Suh, Myung-deuk
    • Korean Journal of Veterinary Research
    • /
    • v.32 no.4
    • /
    • pp.641-647
    • /
    • 1992
  • This study was conducted to determine the serum antibodies against toxoplasma in the artificially infected dogs, pet and street dogs by latex agglutination (LA) and indirect fluorescent antibody (IFA) test. LA test was carried out with commercial Toxo-MT kit (Eiken chemical Co.) and IFA test was carried out with rabbit-anti-dog IgG labelled with FITC (Cappel Co.) and toxo-antigen slides prepared in laboratory. The results obtained were as follows ; 1. Antibodies to Toxoplasma gondii in the artificially infected dogs were detected firstly at the Day 8 in IFA and Day 9 in LA test after inoculation. Positive antibody reactions by these tests were declined gradually afterward but maintained up to 12 weeks. 2. In LA test serum antibody titers in 310 test sera were shown as 10 cases(32%) in 1 : 32.5(1.0%) in 1 : 64, 4(1.3%) in 1 : 128 and 2(0.7%) in 1 : 256. In IFA test serum antibody titers 310 test sera were shown as 17 cases(5.5%) in 1 : 64, 8(2.6%) in 1 : 128 and 5(1.6%) in 1 : 256. 3. In the total of 310 sera from pet and street dogs toxoplasma antibody positive rates were 21 cases (6.8%) by LA and 30 cases (9.7%) by IFA test and the positive detection rates between these two groups by LA and IFA test were not significant(p<0.05). 4. In the total of 115 sera from pet dogs toxoplasma antibody positive rates were 12 cases(10.4%) by LA and 15(13.0%) by IFA test. And in the 195 street dogs the positive rates were 9 cases(4.6%) by LA and 15(7.7%) by IFA test. Also, the positive detection rates between these two groups by LA and IFA test were not significant(p<0.05). 5. Agreement of reactivity between LA and IFA test for 310 sera was 91.3% in total of 283 cases consisting of 12 cases(3.9%) of both LA and IFA positive and 271 cases(87.4%) of LA and IFA negative. 6. LA test was almostly equivalent to the IFA test in producibility and proved to be a simple tool for the screening of toxoplasma antibody in laboratory.

  • PDF

Development of a Rapid Automated Fluorescent Lateral Flow Immunoassay to Detect Hepatitis B Surface Antigen (HBsAg), Antibody to HBsAg, and Antibody to Hepatitis C

  • Ryu, Ji Hyeong;Kwon, Minsuk;Moon, Joung-Dae;Hwang, Min-Woong;Lee, Jeong-Min;Park, Ki-Hyun;Yun, So Jeong;Bae, Hyun Jin;Choi, Aeran;Lee, Hyeyoung;Jung, Bongsu;Jeong, Juhee;Han, Kyungja;Kim, Yonggoo;Oh, Eun-Jee
    • Annals of Laboratory Medicine
    • /
    • v.38 no.6
    • /
    • pp.578-584
    • /
    • 2018
  • Background: Accurate, rapid, and cost-effective screening tests for hepatitis B virus (HBV) and hepatitis C virus (HCV) infection may be useful in laboratories that cannot afford automated chemiluminescent immunoassays (CLIAs). We evaluated the diagnostic performance of a novel rapid automated fluorescent lateral flow immunoassay (LFIA). Methods: A fluorescent LFIA using a small bench-top fluorescence reader, Automated Fluorescent Immunoassay System (AFIAS; Boditech Med Inc., Chuncheon, Korea), was developed for qualitative detection of hepatitis B surface antigen (HBsAg), antibody to HBsAg (anti-HBs), and antibody to HCV (anti-HCV) within 20 minutes. We compared the diagnostic performance of AFIAS with that of automated CLIAs-Elecsys (Roche Diagnostics GmbH, Penzberg, Germany) and ARCHITECT (Abbott Laboratories, Abbott Park, IL, USA)-using 20 seroconversion panels and 3,500 clinical serum samples. Results: Evaluation with the seroconversion panels demonstrated that AFIAS had adequate sensitivity for HBsAg and anti-HCV detection. From the clinical samples, AFIAS sensitivity and specificity were 99.8% and 99.3% for the HBsAg test, 100.0% and 100.0% for the anti-HBs test, and 98.8% and 99.1% for the anti-HCV test, respectively. Its agreement rates with the Elecsys HBsAg, anti-HBs, and anti-HCV detection assays were 99.4%, 100.0%, and 99.0%, respectively. AFIAS detected all samples with HBsAg genotypes A-F and H and anti-HCV genotypes 1, 1a, 1b, 2a, 2b, 4, and 6. Cross-reactivity with other infections was not observed. Conclusions: The AFIAS HBsAg, anti-HBs, and anti-HCV tests demonstrated diagnostic performance equivalent to current automated CLIAs. AFIAS could be used for a large-scale HBV or HCV screening in low-resource laboratories or low-to middle-income areas.

Immunosignature: Serum Antibody Profiling for Cancer Diagnostics

  • Chapoval, Andrei I;Legutki, J Bart;Stafford, Philip;Trebukhov, Andrey V;Johnston, Stephen A;Shoikhet, Yakov N;Lazarev, Alexander F
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.12
    • /
    • pp.4833-4837
    • /
    • 2015
  • Biomarkers for preclinical diagnosis of cancer are valuable tools for detection of malignant tumors at early stages in groups at risk and screening healthy people, as well as monitoring disease recurrence after treatment of cancer. However the complexity of the body's response to the pathological processes makes it virtually impossible to evaluate this response to the development of the disease using a single biomarker that is present in the serum at low concentrations. An alternative approach to standard biomarker analysis is called immunosignature. Instead of going after biomarkers themselves this approach rely on the analysis of the humoral immune response to molecular changes associated with the development of pathological processes. It is known that antibodies are produced in response to proteins expressed during cancer development. Accordingly, the changes in antibody repertoire associated with tumor growth can serve as biomarkers of cancer. Immunosignature is a highly sensitive method for antibody repertoire analysis utilizing high density peptide microarrays. In the present review we discuss modern methods for antibody detection, as well as describe the principles and applications of immunosignature in research and clinical practice.

Production of Polyclonal Antibody against $\alpha$-Fetoprotein and Polyclonal Antibody-Based Competitive Enzyme-Linked Immunosorbent Assay for $\alpha$-Fetoprotein (인간 $\alpha$-fetoprotein (AFP)에 대한 폴리클로날 항체의 생산 및 $\alpha$-fetoprotein 측정용 효소면역분석법 (competitive ELISA)의 개발)

  • Michung Yoon
    • Biomedical Science Letters
    • /
    • v.3 no.2
    • /
    • pp.115-123
    • /
    • 1997
  • $\alpha$-Fetoprotein (AFP) has been a useful marker in screening and/or monitoring patients with hepatocellular carcinoma, gonadal germ cell tumor, gastric carcinoma and neural tube defects. In the present study, it was attempted to produce anti-human AFP polyclonal antibodies and to develop a competitive enzyme-linked immunosorbent assay (ELISA) for the measurement of AFP in human plasma and amniotic fluid. AFP was isolated from amniotic fluid using an isolation procedure consisting of affinity chromatography and preparative polyacrylamide gel electrophoresis. The antibody directed against AFP was raised in rabbits. Double immunodiffusion and Western blotting methods showed that the antiserum was highly specific, reacting with only AFP-containing samples. Standard curve was obtained by using purified AFP and specific antiserum. The assay sensitivity was 5ng/ml and the working range was 5~l,000ng/ml. The within-assay and between-assay coefficient of variance (CV) was 4.5% and 8.5%, respectively. These results indicate that the assay is valuable for the measurement of AFP and found to be simple, reproducible, and accurate.

  • PDF

Preparation and Characterization of Cell Hybrids Producing a Monoclonal Antibody to Human Fibroblast Interferon (Hu IFN-$\beta$) (사람 선유아세포 인터페론(Hu IFN-$\beta$)에 대한 단 Clone성 항체생산세포의 조작과 그 성질에 관한 연구)

  • 김현수;현형환;최경희;문홍모;유무영
    • Microbiology and Biotechnology Letters
    • /
    • v.14 no.3
    • /
    • pp.219-223
    • /
    • 1986
  • In order to preparr the hybridoma cells which produce a monoclonal antibody to human fibroblast interferon(Hu IFN-$\beta$), spleen cells from BALB/cmice immunized with the purified Hu IFN-$\beta$ were fused with NS-O cells, a myeloma cell line. Forty hybrids with high titer among 1300 hybrids Isolated by an ELISA screening method were subcloned using the soft agarose cloning and limiting dilution methods, and 11 hybrids were selected. As a result of iso-typing the hybrids using the mouse monoclonal typing kit, two hybridomas were found to produce 1gG 2a type of monoclonal an-tibodies. The ascites fluid from nude mice inoculated intraperitoneally with the above hybridomas was removed and purified using a protein A-Sepharose CL-4B. Monoclonal antibody was proven to have only the heavy and light chains on SDS-polyacrylamide gel electrophoresis.

  • PDF