• Title/Summary/Keyword: Anti-start

Search Result 62, Processing Time 0.022 seconds

Development of the Anti-Start Air Conditioner Compressor Resonant DC/DC Converter for Commercial Vehicle (상용차를 위한 무시동 에어컨 압축기용 공진형 DC/DC 컨버터 개발)

  • Han, Keun-Woo;Kim, Seong-Gon;Jung, Young-Gook;Lim, Young-Cheol
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.6
    • /
    • pp.557-563
    • /
    • 2014
  • This study deals with a resonant converter of an anti-start air conditioner compressor for commercial vehicles. The anti-start air conditioner compressor must generally have a high current, high efficiency, a low volume, and a low weight. To reduce the switching losses and voltage and current stresses of the device, the anti-start air conditioner compressor applies the full-bridge L-C resonant converter topology. Hardware parameters are designed to have a wide voltage range, and the switching frequency range of the L-C resonant converter is determined. Simulation is implemented using PSIM and an experiment is performed to verify the proposed converter.

Commercial Vehicle Anti-Start Air Conditioner Compressor System Using a Power Conversion Unit (전력변환장치를 이용한 상용차용 무시동 에어컨 압축기 시스템)

  • Han, Keun-Woo;Kim, Seong-Gon;Lee, Chung-Hoon;Choi, Myoung-Hyun;Jung, Young-Gook;Lim, Young-Cheol
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.29 no.6
    • /
    • pp.96-108
    • /
    • 2015
  • his study deals with a power conversion unit of an anti-start air conditioner compressor system for the commercial vehicle. In case of converter, to reduce the switching losses and current stresses of the device, applies LLC resonant topology. Transformer leakage inductance in the full-bridge converter is used for making the resonance with the capacitor of the voltage-doubler. Through this method we can increase power and decrease volume of system. Both circuit analysis and design guideline are described. So in this paper, power conversion unit is designed. 2.5kW anti-start air conditioner compressor system was implemented, and system operation and stability was verified through experiment.

A Study of Temperature Predictions for Manual Transmission Clutch System via Anti-fade and Hill Start Virtual Test (내페이드와 힐스타트 가상 시험을 통한 수동변속기 클러치 시스템의 온도 예측에 관한 연구)

  • Park, Ki-Jong;Kim, Dong-Won
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.23 no.1
    • /
    • pp.122-129
    • /
    • 2015
  • Excessive overheating to a manual transmission clutch system under operating conditions can be considered the main reason of its performance degradation. The clutch system has to be ensured with its service life by showing that it passes the extreme tests called anti-fade test and hill start test in a certain design step. In general, design feedbacks from these kinds of the experiments are adapted to the system to enhance its performance. However, it usually takes much time and costs a lot due to the repetition of the tests. In this research, a process to calculate temperature of the clutch system was developed to determine whether the design can be passed the anti-fade test and hill start test in the design phase. The process incorporates many CAE techniques such as heat transfer analysis using 1D dynamic simulation method, system dynamics, CFD and parametric optimization. CFD is utilized to analyze 3-dimensional heat transfer of the clutch system and fluid dynamics of air in the clutch housing. The process was applied for the clutch systems in several vehicle models. The results was compared with those of the experiment. The applicability of the developed process was verified by comparing the predicted results with experimental results.

Development of Digital DC-ARC Welding Machine

  • Kim, Hak-Kyeong;Park, Ba-Da
    • Journal of Ocean Engineering and Technology
    • /
    • v.20 no.6 s.73
    • /
    • pp.18-23
    • /
    • 2006
  • This paper introduces the results of the development of a new mobile digital DC-arc welding machine (DDWM). A simple PI controller is applied to the DDWM to control the output welding current that is tracking the constant setting current. Furthermore, a hot-start function, an anti-stuck function, a standby mode and an intelligential circuit breaker (ICB) are included in the DDWM. The DDWM increases welding quality and saves more power energy than a conventional welding machine. The DDWM is changed from ready mode into the standby mode, automatically, after 2-minute intervals from this unload start. Then, the DDWM is changed into ready mode, automatically, since it is reused for welding. Moreover, the DDWM increases welding quality, productivity and reduces costs of welding. So, the DDWM can make a considerable contribution to the mobile welding industries. The effectiveness of the DDWM was proven by the experimental results.

DEVELOPMENT OF DIGITAL DC-ARC WELDING MACHINE (디지털 DC-ARC 용접기의 개발)

  • Park Ba-Da;Dung Ngo Manh;Kim Sang-Bong
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2006.06a
    • /
    • pp.71-72
    • /
    • 2006
  • This paper introduces the results of the development of a new mobile Digital DC-arc Welding Machine (DDWM). A simple PI controller is applied to the DDWM to control the output welding current tracking the constant setting current. Furthermore, a hot-start function, an anti-stuck function, a standby mode and an intelligential circuit breaker (ICB) are included in the DDWM. The DDWM increases welding quality and saves more power energy than a conventional welding machine. Because the DDWM is changed from ready mode into the standby mode automatically after 2 minutes interval from this unload start. Then the DDWM is changed into ready mode automatically since it is reused to weld. Mover, the DDWM increases welding qualify, productivity and reduces costs of welding. So, the DDWM can have a great of contribution to the mobile welding industries. The effectiveness of the DDWM was proven by the experimental results and durable test.

  • PDF

Managing the Heterogeneous File System for Anti-Virus

  • Kim, Kyung-Su;Han, Seung-Jo;Kim, Pan-Koo
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.7 no.3
    • /
    • pp.3-10
    • /
    • 1997
  • Computer viruses are increasing in number and are continually intellectualized as well. To cope with this problem, anti-virus tools such as a scanner and the monitoring program have been developed. But it is not guaranteed that these softwares will work in safety under MS-DOS' control. If the virus is run first, it can avoid the monitoring of anti-virus software or even can attack the anti-virus software. Therefore, anti-virus programs should be run before the system is infected. This paper presents a new PC starting mechanism which allows the PC system to start from a clean state after booting. For this mechanism, we build a new disk file system different from DOS' file system, and manage the two file systems heterogeneously. Our system is strong against boot viruses and recovers from infections automatically.

금연침(耳鍼) 시술을 통해 살펴본 대전지역 고등학생의 흡연 실태조사

  • Im, Seung-Hwan;Jeong, Hyeon-A;No, Seok-Seon;Lee, Yong-Gu
    • The Journal of Korean Medicine Ophthalmology and Otolaryngology and Dermatology
    • /
    • v.15 no.2
    • /
    • pp.190-199
    • /
    • 2002
  • After applying anti-smoking acupuncture to 756 high school students at least 4 times, I surveyed about the effect of the therapy. The result of the survey is as follows. 1. The age to start smoking is getting lower. And the rate of female students' smoking is increasing significantly. 2. The survey shows that students started to smoke mainly because of curiosity, stress, peer pressure, and their misunderstanding which the way to smoke looks cool. 3. The anti-smoking acupuncture therapy is expected to decrease the smoking desire because the applicants usually experience headache, dizziness, gastroenteric trouble after the treatment. 4. Students complained about earache and inconvenience of washing. 5. The result shows that the anti-smoking acupuncture therapy is generally efficacious, but the virtue of the therapy is much better with the students' willingness to stop smoking.

  • PDF

Red Cell Alloimmunization and Autoimmunization in Multi-Transfused Thalassemia Patients in Sulaymaniyah Province-Iraq

  • Abdulqader, Aveen M. Raouf;Mohammed, Ali Ibrahim;Mohammed, Nagham Ibrahim
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.2
    • /
    • pp.98-104
    • /
    • 2020
  • Thalassemias are considered important health issues throughout Iraq, involving its Kurdistan region. This disorder, particularly its major form, needs lifelong regular transfusions. But this form of medical care is associated with various complications including red cell alloimmunization and autoimmunization. This study determined the frequency and associations of alloimmunization among multi-transfused patients with β-thalassemia major. The subjects were 204 patients who were registered at a thalassemia care center in Sulaymaniyah-Iraqi Kurdistan. The patients' records were analyzed, their red cells were phenotyped for ABO/RhD antigens using the gel card method, and irregular antibody screening/identification was performed using the standard tube method. Alloantibodies were detected in 5.8% of the patients, while DAT was positive in 4% of the patients, which indicated autoantibodies. The identified alloantibodies were anti-E (2.4%), anti-C (1.4%), anti-e (1%), and anti-K (1%). A patient's age at the start of transfusion (>2 years) (P=0.042) and a positive history of transfusion reactions (P=0.003) were correlated with a significantly higher rate of alloantibody formation. From the results of our study, we conclude that measures to decrease the development of alloantibodies may incorporate matching for Rhesus and Kell systems and early induction of blood transfusions.

Effect of Prophylactic Use of Silymarin on Anti-tuberculosis Drugs Induced Hepatotoxicity

  • Heo, Eunyoung;Kim, Deog Kyeom;Oh, So Hee;Lee, Jung-Kyu;Park, Ju-Hee;Chung, Hee Soon
    • Tuberculosis and Respiratory Diseases
    • /
    • v.80 no.3
    • /
    • pp.265-269
    • /
    • 2017
  • Background: The first line of anti-tuberculosis (TB) drugs are the most effective standard of drugs for TB. However, the use of these drugs is associated with hepatotoxicity. Silymarin has protective effects against hepatotoxicity of anti-TB drugs in animal models. This study aims to investigate the protective effect of silymarin on hepatotoxicity caused by anti-TB drugs. Methods: This is a prospective, randomized, double-blind and placebo-controlled study. Patients were eligible if they were 20 years of age or order and started the first-line anti-tuberculosis drugs. Eligible patients were randomized for receiving silymarin or a placebo for the first 4 weeks. The primary outcome was the proportion of patients who showed elevated serum liver enzymes more than 3 times the upper normal limit (UNL) or total bilirubin (TBil) > $2{\times}UNL$ within the first 8 weeks of anti-TB treatment. Results: We enrolled a total of 121 patients who silymarin or a placebo to start their anti-TB treatment, for the first 8 weeks. The proportions of elevated serum liver enzymes more than 3 times of UNL at week 2, week 4, and week 8 did not show any significant difference between the silymarin and placebo groups, at 0% versus 3.6% (p>0.999); 4.4% versus 3.6% (p>0.999); and 8.7% versus 10.8% (p=0.630), respectively. However, patients with TBil >$2{\times}UNL$ at week 8 were significantly low in the silymarin group (0% versus 8.7%, p=0.043). Conclusion: Our findings did not show silymarin had any significant preventive effect on the hepatotoxicity of anti-TB drugs.

A Reset-Free Anti-Harmonic Programmable MDLL-Based Frequency Multiplier

  • Park, Geontae;Kim, Hyungtak;Kim, Jongsun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.5
    • /
    • pp.459-464
    • /
    • 2013
  • A reset-free anti-harmonic programmable multiplying delay-locked loop (MDLL) that provides flexible integer clock multiplication for high performance clocking applications is presented. The proposed MDLL removes harmonic locking problems by utilizing a simple harmonic lock detector and control logic, which allows this MDLL to change the input clock frequency and multiplication factor during operation without the use of start-up circuitry and external reset. A programmable voltage controlled delay line (VCDL) is utilized to achieve a wide operating frequency range from 80 MHz to 1.2 GHz with a multiplication factor of 4, 5, 8, 10, 16 and 20. This MDLL achieves a measured peak-to-peak jitter of 20 ps at 1.2 GHz.