• 제목/요약/키워드: Anti-resonance Frequency

검색결과 55건 처리시간 0.024초

PSN-PMN-PZT 조성의 CeO2첨가에 따른 압전.유전특성 변화 (Piezoelectric and Dielectric Properties on PSN-PMN-PZT Composition according to CeO2 Addition)

  • 윤만순;최용길;어순철
    • 한국전기전자재료학회논문지
    • /
    • 제19권9호
    • /
    • pp.838-842
    • /
    • 2006
  • 0.03Pb$(Sb_{0.5}Nb_{0.5})O_{3}-0.03Pb(Mn{1/3}Nb{2/3)O_{3}-(0.94-x)PbTiO_{3}-xPbZrO_{3}$ ceramics doped with $CeO_{2}$ were synthesized by conventional bulk ceramic processing technique. Phases analysis, microstructures and piezoelectric properties were investigated as a function of $CeO_{2}$ content (0.03, 0.05, 0.1 0.3, 0.5 and 0.7 wt%). Microstructures and phases information were characterized using a scanning electron microscope (SEM) and an X-ray diffractometer (XRD). Mechanical quality factor ($Q_{m}$) and coupling factor(kp) were obtained from the resonance measurement method. Both $Q_{m}$ and $k_{p}$ were shown to reach to the maximum at 0.1 wt% $CeO_{2}$. In order to evaluate the stability of resonance frequency and effective electromechanical coupling factor ($K_{eff}$) as a function of $CeO_{2}$, the variation of resonance and anti-resonance frequency were also measured using a high voltage frequency response analyzer under various alternating electric fields from 10 V/mm to 80 V/mm. It was shown that the stability of resonance frequency and effective electromechanical coupling factor were increased with increasing the $CeO_{2}$ contents.

핵자기공명 영상법과 핵자기공명 분광법을 위한 뒤집음-탐침의 개발에 대한 연구 (Development of inside-out probes for both Nuclear Magnetic Resonance Imaging and Nuclear Magnetic Resonance Spectroscopy)

  • 이동훈;고락길;정은기
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권3호
    • /
    • pp.309-316
    • /
    • 1995
  • 핵자기공명(Nuclear Magnetic Resonance)에서 신호 획득 시에 가장 중요한 부분중의 하나인 rf-탐침(radio-frequency-probe)은 실험대상이 되는 시료의 기하학적 모양과 획득하고자 하는 정보 등에 따라서 적절히 설계 및 제작되어야 최적의 신호를 얻을 수 있다. 일반적으로, rf-탐침은 시료를 둘러싸는 형태와 시료 표면에 위치하는 형태 등 두 가지로 제작된다. 그러나, 시료나 인체 부위가 관모양을 하고 있으며 관 모양 주위로부터의 신호를 관측하는 경우, 앞에서 기술한 두가지 형태의 탐침을 이용해서는 신호대 잡음비의 저하로 인해 만족할 만한 신호 획득이 어려워진다. 이때, 탐침을 관 모양의 시료 내부에 위치시키고, 관찰하고자 하는 부위에 최대로 가까이하며 탐침의 품격인자를 높이는 것이 최적의 신호획득에 중요한 조건이 되게 된다. 본 논문에서는 탐침을 시료 내부에 넣고 탐침 외부로부터 신호를 얻는 뒤집음-탐침을 역-솔레노이드 saddle 및 이중표면코일 등의 세가지 형태로 제작하고 최적신호의 획득에 대한 시도를 해보았고, 컴퓨터를 이용한 계산을 통하여 기하학적인 모양의 차이에 따른 rf-자기장 발생 상태를 알아보았다. 아울러, 시험시료로부터 발생되는 영상신호를 얻고 영상 영역 내에서 신호대잡음비를 측정하여 탐침들의 성능을 비교 분석했다. 본 연구에서 제작된 뒤집음-탐침의 경우, 어떠한 상품화된 탐침과 비교할 때, 뛰어난 신호대잡음비와 탐침 주위에서 매우 높은 균일성이 유지되었다. 또한, 제작된 형태의 뒤집음-탐침을 이용한 인체 진단에의 응용성은 매우 높을 것으로 예상된다.

  • PDF

기관실 단순 철의장품 모델 고유 진동수 해석 (Analysis of Natural Frequency of Simple Steel Outfitting Structure in Engine Room)

  • 정치석;김대성;조성암;장성일
    • 대한조선학회 특별논문집
    • /
    • 대한조선학회 2006년도 특별논문집
    • /
    • pp.106-111
    • /
    • 2006
  • The steel outfitting structures installed in engine room are vibrated by an excitation of the engine and the propeller. Vibration problems such as cracks and fitting breakages are mainly induced at the near range of the resonance. The excitation frequency estimation is possible by engines and propeller specifications, but the natural frequency of a steel outfitting structure is not easily estimated due to the complication and variety of the designed shape. This paper represents natural frequency data of simple steel outfitting structures. As a vibration analysis tool, MSC/NASTRAN was used to calculate natural frequencies. Natural frequencies were compared in case of the shape and boundary condition changes of simple models, and anti-vibration models of the steel outfitting structures were presented on the basis of results.

  • PDF

초음파 절삭기 핸드피스부 제작 및 변위 특성 시뮬레이션 (Fabrication and Simulation of Displacement Properties of Ultrasonic Generator Handpiece)

  • 김승원;류주현;이지영
    • 한국전기전자재료학회논문지
    • /
    • 제31권3호
    • /
    • pp.152-155
    • /
    • 2018
  • Ultrasonic wave technologies have been widely used in ultrasonic washing machines, ultrasonic surgery, ultrasonic welding machines, ultrasonic sensors, and medical instruments. Ultrasonic surgery can be realized through the cavitation effect of ultrasonic waves. In this study, piezoelectric ceramics were manufactured to achieve the optimum design of a piezoelectric vibrator in a handheld generator for ultrasonic surgery. The best specimen showed the excellent piezoelectric properties of kp=0.624, Qm=1,531, and $d_{33}=356pC/N$. Numerical modeling based on the finite element method was performed to find the resonance frequency, the anti-resonance frequency, and the displacement properties of the handheld ultrasonic generator. Maximum displacement was observed in the six-step piezoelectric vibrator at $6.36{\mu}m$.

Analysis of Appropriate Parameters for Piezoelectric Ceramic Utilization by Using BVD Model

  • Jeerapan, Chalermchai;Sriratana, Witsarut;Julsereewong, Prasit;Kummool, Sart
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.2067-2070
    • /
    • 2005
  • This paper presents an approach to evaluate the appropriate parameters for Piezoelectric ceramic utilization by adopting Impedance Method. Butterworth Van Dyke model (BVD) is considered to use as an equivalent circuit of Piezoelectric ceramic in case of no load. The experimental results from this model will be compared with the results from a circular Piezoelectric ceramic with 4.8 cm. diameter and 3 mm. thickness. The Thickness Mode vibration measured by Impedance Analyzer model 4192A can be analyzed from 1Hz to 13MHz for calculating and analyzing parameters at resonance frequency and anti-resonance frequency. These parameters are evaluated to design the efficient circuit for Piezoelectric ceramic utilization to obtain the optimal efficiency.

  • PDF

진동제어장치를 이용한 고속열차-강아치교의 수직진동제어 (Vertical Vibration Control of High Speed Train-Steel Arch Bridge using Vibration Control Device)

  • 고현무;강수창;유상희;옥승용;추진교
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2003년도 추계 학술발표회논문집
    • /
    • pp.360-367
    • /
    • 2003
  • This paper presents passive vibration control method to suppress train-induced vibration on a long-span steel arch bridge. According to the train load frequency analysis, undesirable resonance of a bridge will occur when the impact frequency of the train axles are close to the modal frequencies of the bridge. Because the first mode shape of the long-span steel arch bridge may take anti-symmetric shape along the bridge direction, however, the optimal control configuration for resonance suppression should be considered carefully In this study, bridge-vehicle element is used to estimate the bridge-train interaction precisely. From the numerical simulation of a loom steel arch bridge under TGV-K train loading, dynamic magnification influences are evaluated according to vehicle moving speed and efficient control system with passive dampers are presented in order to diminish the vertical displacement and vertical acceleration.

  • PDF

다공패널형 공명기의 흡음성능에 관한 연구 (A Study on the Absorption Performance of a Perforated Panel type of Resonator)

  • 송화영;양윤상;이동훈
    • 설비공학논문집
    • /
    • 제28권6호
    • /
    • pp.224-231
    • /
    • 2016
  • When aiming to reduce the low frequency noise of a subway guest room through sound absorbing treatment methods inside the wall of a tunnel the resonator is often more effective than a porous sound absorbing material. Therefore, the perforated panel type resonator embedded with a perforated panel is proposed. The perforated panel is installed in the neck, which is then extended into the resonator cavity so that it can ensure useful volume. The absorption performance of the perforated panel type of resonator is obtained by acoustic analysis and experiment. The analytical results are in good agreement with the experimental results. In the case of multiple perforated panel type resonators, as the number of perforated panels increase, the 1st resonance frequency is moved to a low frequency band and sound absorption bandwidth is extended on the whole. In order to obtain excellent absorption performance, the impedance matching between multi-panels should be considered. When the perforated panel in the resonator is combined with a porous material, the absorption performance is highly enhanced in the anti-resonance and high frequency range. In case of the resonator inserted with perforated panels of 2, the 2nd resonance frequency is shifted to a low frequency band in proportion to the distance between perforated panels.

운전자용 의자의 부강성 진동 절연 시스템 (Vibration Isolation System for Driver's Seats with Negative Stiffness)

  • 박성태;이상주
    • 한국자동차공학회논문집
    • /
    • 제18권2호
    • /
    • pp.114-121
    • /
    • 2010
  • As a vehicle speed increases, more vibration energy is transmitted from chassis to a driver. Current isolation system for the driver's seat by damping control can reduce the transmitted vibration energy near resonance area. But in higher frequency region than natural frequency multiplied by $\sqrt{2}$, the vibration energy transmitted to the driver has a tendency to be increased. Therefore, the method by natural frequency reduction of the system is preferred to increase the effectiveness of the anti-vibration. However, the natural frequency could not be freely reduced due to the nature of the isolation system structure. A new passive suspension system to reduce the natural frequency is proposed. The theoretical analysis and experimental results show better vibration attenuation compared with the current isolation system.

자기공명영상장치(磁氣共鳴映像裝置)에서 움직임허상(虛像)의 위치제어(位置制御)에 관(關)한 연구(硏究) (A Study on Locational Control of Motion Ghost in Magnetic Imaging System)

  • 이후민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제16권2호
    • /
    • pp.19-26
    • /
    • 1993
  • Magnetic Resonance Image represents three-dimensional diagnostic imaging technique using both nuclear magnetic resonance phenomenon and computer. Compared with computed tomography (CT), MRI have advantages harmless to patient's body, three-dimensional image with high resolution and disadvantages long data acquisition time because of long T1 relaxation time, relatively low signal to noise ratio, high cost of setting, also. As physiologic motion of tissue results in motion ghost in MRI, high 2.0Tesla make improve low signal to noise ratio. This study have aim to improve image quality with controling motion ghost of tissue. Supposing a moving pixel in constant frequency, one pixel make two ghosts which are same size and different anti-phase. So, this study will show adjust parameter on locational control of motion ghost. Author made moving phantom replaced by respiratory movement of human, researched change of motion frequency, FOV by location shift, and them decided optimal FOV (field of view). The results are as follows: 1. The frequency content of the motion determines how far the image always appear in phase-encoding direction, the morphology of the ghost image is characteristic of the direction of the motion and its amplitude. 2. Double FOV of fixed signal object for locational control of motion ghost is recommended. Decreasement of spatial resolution by increasing FOV can compensate on increasing of matrix in spite of scan time increasement.

  • PDF

급성 화폐상 습진을 동반한 아토피 피부염 환자의 한방치험 1례

  • 김혜정
    • 한방안이비인후피부과학회지
    • /
    • 제14권1호
    • /
    • pp.111-116
    • /
    • 2001
  • Nummular eczema is well-shaped, coin-like lesion. Usually it is surrounded by the papules and vesicles, and is likely to be the impetigo. It's said that nummular eczema is combined with atopic dermititis, contact dermatitis, bacterial infection and so on. Recently, we experienced a nummular eczema with impetigo and that was successfully treated by the herb-medication and the ceramic resonance therapy. The medications taken by the patient were yunwhasagnatang and gamisopungsan which is used to treat allergic disease and make immune system be strong. The former effects the liver to be cool down and healthy and it also has anti-imflamatory reactions like the corticosteroid hormone. Ceramic resonance therapy utilises irradiation within the frequency range of the radiation emitted by the human body. So we report this case with a brief review of the oriental medical and medical literatures.

  • PDF