• Title/Summary/Keyword: Anti-pollution film

Search Result 7, Processing Time 0.019 seconds

Characterization of Anti-pollution Film according to the Annealing Temperature for PV Module (태양광 모듈용 내오염성 필름의 열처리 온도에 따른 특성 분석)

  • Yoo, Seung-cheol;Choi, WonSeok;Lim, Yoonsik;Kim, Junghyun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.1
    • /
    • pp.33-36
    • /
    • 2018
  • The purpose of this study is to improve the efficiency of anti-pollution film for PV module. The anti-pollution coating process was performed on a glass substrate, which is the same material as the glass substrate for the PV module. We coated the anti-pollution film on the glass substrate by spray coating. After coating process, annealing process was performed during 1 hour at $200^{\circ}C$, $300^{\circ}C$, and $400^{\circ}C$. And then we analyzed the surface characteristics according to the annealing temperature of the film. Annealing process can also improve the durability of the coated film. And then we analyzed the anti-pollution characteristics, particle size of anti-pollution film, light transmittance. The particle size of anti-pollution film was analyzed with FE-SEM. The light transmittance was analyzed with UV-Visible spectroscopy including integrating sphere.

Effects of Annealing Ambient on the Anti-Pollution and Mechanical Properties of Functional Film Coated on the Ceramic Substrate (세라믹 기판위에 코팅된 기능성 필름의 열처리 분위기에 따른 내오염 및 기계적 특성)

  • Shan, Bowen;Kang, Hyunil;Choi, Won Seok;Joung, Yeun-Ho
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.29 no.4
    • /
    • pp.215-217
    • /
    • 2016
  • For the improvement of the anti-pollution properties of porcelain electrical insulators, in this study, we have applied the functional film to the surface of insulator. The functional films were coated on the ceramic substrates which components were like the porcelain electrical insulator. The coating material was applied to ceramic substrate by spray coating method and then the film was cured at around $300^{\circ}C$ for 10 minutes with different gas ambient, such as $O_2$, $N_2$, and only vacuum. We have measured the contact angle of the coated surface, and obtained the lowest angle ($8.9^{\circ}$) and a strong hydrophilic property at vacuum condition. The anti-pollution properties were measured, revealing that as the contact angle decreased, the anti-pollution properties improved. The mechanical hardness and adhesion were both excellent regardless of the annealing ambient.

Characteristics of Annealing Properties of Anti-pollution Coatings for the Cover Glass of PV Module (PV 모듈 커버글라스 오염방지 코팅의 열처리 특성분석)

  • Jung, Sejin;Lim, Yonnsik;Kim, Junghyun;Choi, Wonseok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.66 no.4
    • /
    • pp.263-266
    • /
    • 2017
  • In this study, the characteristics of anti-pollution coatings on glass substrates through annealing treatment were investigated. To investigate the change of properties by coating method and number of annealing treatment, after the anti-pollution coating was performed on the surface of glass substrate in three ways, the annealing treatment was performed by setting three kinds of annealing treatment conditions. The annealing treatment method is a torch using gas, which is advantage in that it can be installed directly on the site in an easy way compared with a annealing treatment process which is generally difficult. The anti-pollution properties, contact angle, transmittance, hardness, and adhesion of films on glass substrate were measured under 9 conditions of combination of coating methods and annealing treatment conditions. It was confirmed that as the number of annealing treatment increases, the anti-pollution property of the film synthesized on glass substrate becomes better.

Preparation of graphene oxide incorporated polyamide thin-film composite membranes for PPCPs removal

  • Wang, Xiaoping;Li, Nana;Zhao, Yu;Xia, Shengji
    • Membrane and Water Treatment
    • /
    • v.9 no.4
    • /
    • pp.211-220
    • /
    • 2018
  • Incorporating nano-materials in thin-film composite (TFC) membranes has been considered to be an approach to achieve higher membrane performance in various water treatment processes. This study investigated the rejection efficiency of three target compounds, i.e., reserpine, norfloxacin and tetracycline hydrochloride, by TFC membranes with different graphene oxide proportions. Graphene oxide (GO) was incorporated into the polyamide active layer of a TFC membrane via an interfacial polymerization (IP) reaction. The TFC membranes were characterized with FTIR, FE-SEM, AFM; in addition, the water contact angle measurements as well as the permeation and separation performance were evaluated. The prepared GO-TFC membranes exhibited a much higher flux ($3.11{\pm}0.04L/m2{\cdot}h{\cdot}bar$) than the pristine TFC membranes ($2.12{\pm}0.05L/m2{\cdot}h{\cdot}bar$) without sacrificing their foulant rejection abilities. At the same time, the GO-modified membrane appeared to be less sensitive to pH changes than the pure TFC membrane. A significant improvement in the anti-fouling property of the membrane was observed, which was ascribed to the favorable change in the membrane's hydrophilicity, surface morphology and surface charge through the addition of an appropriate amount of GO. This study predominantly improved the understanding of the different PA/GO membranes and outlined improved industrial applications of such membranes in the future.

Evaluation of Corrosion Resistance of Anti-Corrosive Paint by Investigation of Diffusion Limiting Current Density (확산한계전류밀도 고찰에 의한 방청도료의 내식성평가)

  • Moon, Kyung-Man;Kim, Yun-Hae;Lee, Myung-Hoon;Lee, In-Won;Park, Hyun;Chun, Ho-Hwan
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.64-68
    • /
    • 2009
  • It has been observed that coated steel structures deteriorate more rapidly than the designed lifetime due to acid rain caused by air pollution, etc. Therefore, improving the corrosion resistance of anti-corrosive paint is very important in terms of safety and the economic point of view. In this study, the corrosion resistance of five kinds of anti-corrosive paints, including the Acryl, Fluorine, and Epoxy resin series, were investigated with electrochemical methods, such as corrosion potential measurements, polarization curves, diffusion limiting current density, etc. As a result, the corrosion resistance of the F101 specimen with the fluorine resin series was found to be superior to the other specimens, while E100 with the epoxy resin series also showed a somewhat good corrosion resistance. Furthermore, it was observed that the amount of water and oxygen entering the inner side of a painted film increased with an increase in immersion time, irrespective of the kind of resin series. However, the oxygen diffusion limiting current density of a specimen with good corrosion resistance was relatively decreased compared to other specimens, because of the difficulty of oxygen diffusion penetrating to the inner side of the film. Consequently it is suggested that we can qualitatively evaluate the corrosion resistance of an anti-corrosive paint by measuring the diffusion limiting current density as an electrochemical method.

Characteristic Analysis of Functional Nano-coating Films Synthesized according to the Annealing Ambient and Fabrication of Anti-pollution PV Module (기능성 나노코팅 박막의 열처리 분위기에 따른 특성분석 및 오염방지 태양광 모듈제작)

  • Kang, Hyunil;Shin, Seung Kwon;Kim, Hyungchul;Lim, Yonnsik;Yoo, Youngsik;Joung, Yeun-Ho;Kim, Junghyun;Choi, Won Seok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.3
    • /
    • pp.182-186
    • /
    • 2015
  • We investigated that effects of annealing ambient on the characteristics of functional nano thin film synthesized on glass substrate. The functional nano thin films were annealed by using rapid thermal annealing (RTA) equipment in vacuum, oxygen and nitrogen ambient, respectively. The hardness of the functional nano thin films were measured by a standard hardness testing method (ASTM D3363) such as a H-9H, F, HB and B-6B pencil (Mitsubishi, Japan). Also, the adhesion of the functional nano thin films were measured by a standard adhesion testing method (ASTM D3359) using scotch tape (3M, Korea). The contact angle of the functional nano thin films was measured by a contact angle analyzer (Phoenix 300 Touch, S.E.O.). The optical property of functional nano thin films was measured via UV-visible spectroscopy (S-3100, Scinco).

Constructability of a Waterproofing Sheet Joint Combining an Aluminum Thin-film and Viscosity Layer Using a High-frequency Inductive Heating Apparatus (고주파 유도가열 장치를 이용한 알루미늄 박판 점착 복합방수시트 조인트부의 시공성)

  • Chang, Sang Mook;Kim, Yun Ho;Choi, Sung Min
    • Journal of the Korea Institute of Building Construction
    • /
    • v.14 no.2
    • /
    • pp.163-169
    • /
    • 2014
  • Engineers in the construction field have been using bonded waterproofing sheets in an attempt to resolve the imbalance in the quality, the risk of fire, safety of workers, and environmental pollution, as well as to eliminate separate use of organic adhesives on the surface of concrete. Recently, self-laminated waterproofing sheets have been developed. The purpose of this research is to find an appropriate processing speed according to the changes in physical properties, and visual observation of the waterproofing sheets laminated by the aluminum thin-film and viscosity layer that can be attached through self-adhesiveness on the surface of concrete and waterproofing sheets. Therefore, this research is conducted using a physical performance test. Based on the result of the test, when the high-frequency inductive heating apparatus was used, an improved adhesion and bonding stability effect were confirmed after the anti-hydrostatic pressure and bond strength in the temperature condition, and the surface observation in the processing speed condition.