• Title/Summary/Keyword: Anti-pollution facilities

Search Result 9, Processing Time 0.024 seconds

A Study on the Administration for the Han River Water Quality Control (漢江 水質保全 行政에 관한 硏究)

  • Kim, Kwang Hyop
    • Journal of Environmental Health Sciences
    • /
    • v.10 no.2
    • /
    • pp.9-40
    • /
    • 1984
  • This thesis purports to overview the diverse administrative and organizational factors and plannings developed by the government organizations, municipal or otherwise, to tackle the Han River water pollution issues in the past years. This thesis also looks into the ever-worsening Han River water pollution problems, in particular, in terms of the various government plans ostensibly designed to reduce the pollution level but with little success. Also dealt with are the efficiencies with which the laws and decrees on water pollution the administrative organizations put to use in the prosecution of the diverse antiwater pollution projects involving the Han River basin. From the early 1960's up to the 1970's the government had concentrated on the growth-oriented economic policy with the result that little attention had been paid to the water pollution and other environmental issues that are bound to arise from the massive economic growth. Belatedly, the five-year Hah River Development Project was initiated in 1982 with emphasis on reducing the water pollution level at Hah River to the minimum. The following are the gists of the thesis and recommendations for the future antiwater pollution plans by the administrative organizations: 1. Documents to date indicate that the irrigation projects along the Han River area had been the main focus of attention during the Yi Dynasty and under the Japanese rule of the country. 2. Despite that the water pollution issue became the subject of many debates among the academic and research institutions in the 1960's and in the 1970's, the administrative organizations in charge of the Han River water quality control failed to come up with a concrete plan for the river's water quality control. 3. Nevertheless, the water pollution of the Han River area in fact began in the 1950's, with the unprecedented concentration into Seoul of population and the industrial facilities on a larger scale, in particular, enforced by the government's strong growthoriented policy in its Economic Development plans in the 1960's. 4. Starting in the 1960's, the Han River water pollution level dramatically increased, but the government was reluctant to promulgate or put into effect strong measures to curb the many factors contributing to the river water pollution, thus worsening the environmental issues along the Han River basin. 5. The environmental protection law and other laws and decrees relating to the antiwater and air pollution issues that were subsequently put into effect underwent so many changes that efficient anti-water pollution policies could not be effected for the Han River basin. The frequent organizational reshuffle within the administrative units concerned with environmental problems has resulted in the undue waste in personnel management and finance. 6. The administration on the environmental protection could not be efficiently carried out due to the organizational overlapping. Under the existing law, frequent organizational frictions and inefficiency are bound to occur among the central government offices themselves, as well as between the central government and the Seoul city administration, and among the city's administrative offices over the conservation of the Han River basin and over the river's anti-water pollution issue. 7. In the planning and prosecution of the Han River project, political influences from the president down to the lower-level politicious appear to have been involved. These political influences in the past had certainly had negative influence on the project, nevertheless, it appears that in the recent years, these political influences are not all that negative in view of the fact that they serve as a positive contributing factor in developing a better water quality control project along the Han River basin. The following are a few recommendations based on the data from the thesis: First, officials in charge of the Han River water quality control should pay attention to a careful screening of the opinions and recommendations from the academic circles and from the public should be made so that the government could better grasp the core issues in the environmental problems that require preventive and other necessary measures. Second, vigorous redistribution policies of population and industrial facilities away from the Seoul area should be pursued. Third, the government should refrain from revising or revamping too frequently the laws and decrees on the anti-water pollution, which is feared to cause undue inconveniences in the environmental administration. Fourth, a large-scale streamlining should be made to the existing administrative organization in an effort to do away with the inter- and intra-organizational friction. It is recommended that a secretariat for the Hah River basis conservation be established. Fifth, High-level administrative officials, with a thorough knowledge and vision on the Han River water quality control, should be prepared to better deal with the budgeting and personnel management for the Han River water pollution control not only at the control government, but also at the Seoul city municipal government levels. Environmental issues should be kept distinct from political issues. Environmental issues should not serve as a window-dressing for sheer political purposes. Sixth, the Hah River proiect should also include, along with the main Han River basin, those areas covering North Han River, South Han River, and the tributaries to the main river basin. The 'Han River Basin Water Quality Control Board' should be established immediately as a means of strengthening the current Han River basin water quality control policy. Seventh, in drawing up the Han River proiect, the administrative officials should be aware that Han River basin is a life line for those people in the region, providing them with not only a sheer physical space, but with a psychological living space for their everyday life.

  • PDF

Proper Estimating Method for Environmental Preservation Cost in Road Projects (도로공사 환경보전비의 적정 산출 방안)

  • Park, Ji-Sun;Lee, Sea-Hyun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.13 no.2
    • /
    • pp.3-10
    • /
    • 2012
  • The current enforcement regulation of "Construction Technology Management Act" prescribes calculation standard of environmental preservation cost in construction site. According to this standard, environmental preservation cost is calculated by using the quantity-per-unit costing method or applied fixed rate on direct cost. However, when calculated by using the quantity-per-unit costing method it is few items to put in the budget according to standard of construction estimate and in the case of using the fixed rate on direct cost it is not considering various characteristics of the construction site. Therefore, it is needed a improvement plan of estimating method and management system for environmental preservation cost. In this study, it surveyed the actual state of the environmental preservation cost according to magnitude of project, site location, anti-pollution facilities and etc. over 38 road projects. The research reported in this paper environmental preservation cost was variously distributed over construction sites. Thus it needs to estimating method and management system to consider characteristics of construction site for environmental preservation cost.

A Study on the Legal Nature of the Duty to Arrange Spill Clean-up Equipment and the Issue on the Justification of Its Privatization (방제선 등 배치의무의 법적 성질 및 민간개방의 정당성에 관한 연구)

  • Lee, Jung Won
    • Ocean policy research
    • /
    • v.33 no.2
    • /
    • pp.83-119
    • /
    • 2018
  • Under the Korean Marine Environment Management Act (hereunder, the KMEMA), the duty to arrange spill clean-up equipments, including spill clean-up vessels, required by the article 67 of the KMEMA is in essence the provision of public goods since it is a precautionary or preventive measure for the efficient performance of oil spill cleaning up. Also the obligation to control marine pollution and the duty to arrange of anti-pollution measures imposed on polluters is the obligation imposed by the public law in accordance with "the Polluter-Pays Principle". Therefore, the execution of such obligations shall be accompanied by the minimum legal and institutional arrangements. On the other hand, judging whether to form the roles of the public and private sectors in providing public goods is basically a matter of policy decision. However, even if the private sector is allowed to participate in the provision of public goods, it is imperative that a minimum requirement be provided to secure the public interest. Although major countries allows polluters to conclude a preliminary contract with a civil anti-pollution management company, these civilian institutions are in principle constituted by the owners of oil storage facilities. Additionally it is worth noting that it operates as a non-profit organization. In particular, if the practitioner performs pollution control for commercial purposes, their profitability may depend on the size of the pollution, the period spent on pollution control, the size of the equipment and manpower mobilized in the pollution control, and so on. Considering the above problems, caution should be taken to allow marine environmental management companies to be un-limitedly entrusted with the responsibility of arranging measures such as pollution control. In order to allow the marine environmental management contractor to be entrusted for the assignment of duty to protect the marine environment, the marine environment management business should be expanded so that the marine pollutant management capacity satisfies the statutory control capacity. For this purpose, it is necessary to manage and supervise the maintenance and improvement of the control capability of the marine environment management business. It is also necessary to discuss the introduction of the grading system for the control ability of the civil control companies alike in major countries.

A Study on the Consciousness of University-Students Concerning the Environmental Protection (環境保全에 관한 대학생의 認識調査 연구)

  • Son, Bu Soon
    • Journal of Environmental Health Sciences
    • /
    • v.12 no.1
    • /
    • pp.79-89
    • /
    • 1986
  • The purpose of this study is to provide the basic data in solving the environmental problem and in environmental education to University-students by searching the consciousness of Universitystudents' attitude toward and general views on the environmental protection. Out of total of 34 universities located in Seoul I randomly selected 11 universities and I again selected 700 university-students to answer my questionnaires. After that the questionnaires were added up by using computer. The major findings of this study are as follows 1. Regarding the overall conditions of the environmental pollution in our country, 91.1% of respondents marked "serious". 2. In suffering from Air pollution, 38.9% of respondents frequently suffered and 36.1% of them always suffered. Only 25.0% of total respondents represented their dislike about so-called "pollution-giving industries", which they do not wish to introduce for the sake of environmental protection. 3. In the source of information concerning the environment, 48.3% of them from the Television, 34.9% them from the newspaper. 4. In the attitude toward the participation for environmental protection, 28.0% of respondents expressed spontaneous attitude. 79.1% of total respondents have the basic desire to establish anti-pollution facilities and only 9.1% of total respondents have replied the ultimate responsibilities of enviironmental pollution. 5. Finally, only 13.3% of total respondents expressed their opinion that hte government officials willingly comply with students' request for better environmental protection and reflect them on their basic policies, and 32.1% of them said that the concerned government officials' attitude were positove and friendly toward the civilians, and 30.6% of them expressed their opinion that those concerned government officals ate holding professional and technicals know-which are necessaty and enough to the concerned field.

  • PDF

The Fact-finding and Analysis of the Environmental Management Cost in Construction Projects (건설공사의 환경관리비용 계상 및 운용 실태 분석)

  • Choi, Min-Soo;Kang, Woon-San
    • Korean Journal of Construction Engineering and Management
    • /
    • v.6 no.5 s.27
    • /
    • pp.186-192
    • /
    • 2005
  • The purpose of this study is to find the reality of environmental management cost in construction projects and to suggest some policies in order that owners appropriate the environmental management cost reasonably in the construction budget for reducing the environmental pollution at job sites. We surveyed the actual state of appropriating and expending the environmental management cost over 122 construction sites. According to the results of the survey, while the appropriated rate of the environmental management cost was 0.59% of the total construction cost. the expended rate reached at 0.94%. When examining the antipollution facilities which were operated in job sites, the investment for equipment against air-pollution such as tire washer, dust-proof device was relatively higher than other antipollution equipment. As the method appropriating the environmental management cost, we concluded that a quantity-per-unit costing method is more reasonable than appropriating at a fixed rate of total construction cost considering that there is little correlation between total construction cost and the environmental management cost. To do so, antipollution facilities that must be examined at a design or estimation stage of a construction project should be prescribed by the law. Moreover, referenced cost data for the quantity-per-unit costing should be prepared and officially published.

A General Study on Bareboat Charter Register in opening Ship's Registration of Shipping Countries (선적개방에 따른 나용선등록제도에 관한 고찰)

  • 강동수
    • Journal of the Korean Institute of Navigation
    • /
    • v.18 no.1
    • /
    • pp.63-84
    • /
    • 1994
  • Bareboat Charter Register or Dual Registration under a Demise Charter scheme, does not in fact sanc-tion the alternative use of flags of different states, but rather it authorises the use of the flag of the coun-try where the ship is temporarily flagged only. Bareboat Charter Register is not intended to miselead third party states or persons dealing with the ship in respect of its nationality. Bareboat Charter Register gives a shipwner a more flexible and attractive package, for example mortga-ging facilities might be more attractive in one state because of its stronger laws relating to recovery of liens, whereas the manning requirements might be attractive in another state. By using Bareboat Charter Register, a shipwner/manager can avail himself of both advantage instead of settling for a compro-mise. Ships on a Bareboat charter Register would be subject to the safety, manning and anti-pollution require-ments of the second flag state and would carry that state's right to fly a flag of the original state be withd-rawn and the effect is to suspend the registration during the period of demise charter except in so far as relates to Title transactions.

  • PDF

Evaluation of Ozone Resistance and Anti-Corrosion Performance of Water Treatment Concrete according to Types of Metal Spray Coating (수처리시설용 콘크리트의 금속용사 피막 종류에 따른 내오존성 및 전기화학적 방식 성능 평가)

  • Park, Jin-Ho;Choi, Hyun-Jun;Lee, Han-Seung;Kim, Sang-yeol;Jang, Hyun-O
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.4
    • /
    • pp.61-68
    • /
    • 2019
  • As the pollution of water resources deteriorates due to industrialization and urbanization, it is difficult to supply clean water through a water treatment method using chlorine. Therefore, the introduction of advanced water treatment facilities using ozone is on the increase. However, epoxy which is used as waterproofing and anticorrosives and stainless steel used in conventional waterproofing and anti-corrosive methods have deteriorated because of the strong oxidizing power of ozone, causing problems such as leaking. Moreover, it even causes the durability degradation of a concrete. Therefore, in this study, metal spraying system was used as the means of constructing a metal panel with excellent ozone resistance and chemical resistance which is an easier method than an existing construction method. Ozone resistance was evaluated in accordance with the type of metal sprayed coatings to develop a finishing method which can prevent the concrete structure of water treatment facilities from deterioration. Furthermore, electrochemical stability in actual sewage treatment plant environment was evaluated. Experimental results showed that Ti has superior ozone resistance after spraying and the electrochemical stability in the sewage treatment plant environment showed that Ti has the highest polarization resistance of $403.83k{\cdot}{\Omega}{\cdot}cm^2$, which ensures high levels of durability.

The Present State of Domestic Acceptance of Various International Conventions for the Prevention of Marine Pollution (해양오염방지를 위한 각종 국제협약의 국내 수용 현황)

  • Kim, Kwang-Soo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.12 no.4 s.27
    • /
    • pp.293-300
    • /
    • 2006
  • Domestic laws such as Korea Marine Pollution Prevention Law (KMPPL) which has been mae and amended according to the conclusions and amendments of various international conventions for the prevention a marine pollution such as MARPOL 73/78 were reviewed and compared with the major contents of the relevant international conventions. Alternative measures for legislating new laws or amending existing laws such as KMPPL for the acceptance of major contents of existing international conventions were proposed. Annex VI of MARPOL 73/78 into which the regulations for the prevention of air pollution from ship have been adopted has been recently accepted in KMPPL which should be applied to ships which are the moving sources of air pollution at sea rather tlnn in Korea Air Environment Conservation Law which should be applied to automobiles and industrial installations in land. The major contents of LC 72/95 have been accepted in KMPPL However, a few of substances requiring special care in Annex II of 72LC, a few of items in characteristics and composition for the matter in relation to criteria governing the issue of permits for the dumping of matter at sea in Annex III of 72LC, and a few of items in wastes or other matter that may be considered for dumping in Annex I of 96 Protocol have not been accepted in KMPPL yet. The major contents of OPRC 90 have been accepted in KMPPL. However, oil pollution emergency plans for sea ports and oil handling facilities, and national contingency plan for preparedness and response have not been accepted in KMPPL yet. The waste oil related articles if Basel Convention, which shall regulate and prohibit transboundary movement of hazardous waste, should be accepted in KMPPL in order to prevent the transfer if scrap-purpose tanker ships containing oil/water mixtures and chemicals remained on beard from advanced countries to developing and/or underdeveloped countries. International Convention for the Control if Harmful Anti-Fouling Systems on the Ships should be accepted in KMPPL rather tlnn in Korea Noxious Chemicals Management Law. International Convention for Ship's Ballast Water/Sediment Management should be accepted in KMPPL or by a new law in order to prevent domestic marine ecosystem and costal environment from the invasion of harmful exotic species through the discharge of ship's ballast water.

  • PDF

Reduction of VOCs and the Antibacterial Effect of a Visible-Light Responsive Polydopamine (PDA) Layer-TiO2 on Glass Fiber Fabric (Polydopamine (PDA)-TiO2 코팅 유리섬유 직물을 이용한 VOCs의 저감 성능 및 항균성 연구)

  • Park, Seo-Hyun;Choi, Yein;Lee, Hong Joo;Park, Chan-gyu
    • Journal of Environmental Health Sciences
    • /
    • v.47 no.6
    • /
    • pp.540-547
    • /
    • 2021
  • Background: Indoor air pollutants are caused by a number of factors, such as coming in from the outside or being generated by internal activities. Typical indoor air pollutants include nitrogen dioxide and carbon monoxide from household items such as heating appliances and volatile organic compounds from building materials. In addition there is carbon dioxide from human breathing and bacteria from speaking, coughing, and sneezing. Objectives: According to recent research results, most indoor air pollution is known to be greatly affected by internal factors such as burning (biomass for cooking) and various pollutants. These pollutants can have a fatal effect on the human body due to a lack of ventilation facilities. Methods: We fabricated a polydopamine (PDA) layer with Ti substrates as a coating on supported glass fiber fabric to enhance its photo-activity. The PDA layer with TiO2 was covalently attached to glass fiber fabric using the drop-casting method. The roughness and functional groups of the surface of the Ti substrate/PDA coated glass fiber fabric were verified through infrared imaging microscopy and field emission scanning electron microscopy (FE-SEM). The obtained hybrid Ti substrate/PDA coated glass fiber fabric was investigated for photocatalytic activity by the removal of ammonia and an epidermal Staphylococcus aureus reduction test with lamp (250 nm, 405 nm wavelength) at 24℃. Results: Antibacterial properties were found to reduce epidermal staphylococcus aureus in the Ti substrate/PDA coated glass fiber fabric under 405 nm after three hours. In addition, the Ti substrate/PDA coated glass fiber fabric of VOC reduction rate for ammonia was 50% under 405 nm after 30 min. Conclusions: An electron-hole pair due to photoexcitation is generated in the PDA layer and transferred to the conduction band of TiO2. This generates a superoxide radical that degrades ammonia and removes epidermal Staphylococcus aureus.